REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

Similar documents
REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: GRABBER NAILS FOR GYPSUM WALLBOARD INSTALLATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC.

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: STO CORP.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: TENDON SYSTEMS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS DIVISION: SIDING REPORT HOLDER: VM ZINC

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

REPORT HOLDER: STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) 35 EAST WACKER DRIVE, SUITE 850 CHICAGO, ILLINOIS EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: AMERICAN EAGLE MATERIALS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: BONSAL AMERICAN, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

REPORT HOLDER: WARE INDUSTRIES, INC. (DBA Marino\WARE) 400 METUCHEN ROAD SOUTH PLAINFIELD, NEW JERSEY EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING SECTION: FACED PANELS REPORT HOLDER:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Trusted ICC ES MILAN ITALY SYSTEMS. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE (WAVE)

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: ULTRAKOTE PRODUCTS, LLC

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PJ S REBAR INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

Transcription:

0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 689 Reissued 07/206 This report is subject to renewal 07/208. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 24 00 EXTERIOR INSULATION AND FINISH SYSTEMS SECTION: 07 24 9 WATER DRAINAGE EXTERIOR INSULATION AND FINISH SYSTEM REPORT HOLDER: PAREX USA, INC. 425 EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA 92807 EVALUATION SUBJECT: PAREX USA WATERMASTER LCR SYSTEM, LAHABRA WATERMASTER LCR AND EL REY WATERMASTER LCR SYSTEMS 204 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 208 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-689 Reissued July 206 Revised April 208 This report is subject to renewal July 208. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 24 00 Exterior Insulation and Finish Systems Section: 07 24 9 Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: PAREX USA, INC. 425 EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA 92807 (74) 778-2266 www.parexusa.com EVALUATION SUBJECT: PAREX USA WATERMASTER LCR SYSTEM, LAHABRA WATERMASTER LCR AND EL REY WATERMASTER LCR SYSTEMS.0 EVALUATION SCOPE Compliance with the following codes: 205, 202 and 2009 International Building Code (IBC) 205, 202 and 2009 International Residential Code (IRC) Properties evaluated: PROPERTY IBC CHAPTER IRC CHAPTER Weather resistance 4 R7 Structural transverse wind load 6 R6 resistance Fire-resistance-rated construction 7 R3 Exterior insulation and finish systems (EIFS) 4 R7 Surface burning characteristics 26 R3 2.0 USES The Parex USA WaterMaster LCR system, LaHabra WaterMaster LCR system and El Rey WaterMaster LCR system are exterior insulation and finish systems (EIFS) complying with IBC Section 408 and IRC Section R703.9. The systems comply as an EIFS with drainage in accordance with IBC Section 408.4. and IRC Section R703.9. The systems may be used in fire-resistance-rated, Type V construction when installed in accordance with Section 4.5 of this report. 3.0 DESCRIPTION 3. System Components: See Table. 3.2 Insulation Board: Insulation boards must be one of the following: a. Parex WaterMaster Insulation Board, LaHabra WaterMaster Insulation Board and El Rey WaterMaster Insulation Board, which are expanded polystyrene (EPS) complying with ASTM C578, Type I, and ASTM E2430. The boards are produced by a molder who participates in an approved third-party quality assurance program, and are labeled in accordance with Section 7.0 of this report. The boards include / 4 -inch-deep-by- / 2 inch-wide (3.2 mm by 38 mm) corrugations across their width. b. Flat EPS insulation board from a molder with a current evaluation report showing conformance to ASTM E2430. The board must be labeled in accordance with the applicable report. c. Flat EPS insulation board that complies with ASTM C578, Type I, and ASTM E2430. The board is produced by a molder who participates in an approved third-party quality assurance program, and is labeled in accordance with the applicable code. 3.3 Substrates: Gypsum sheathing complying with ASTM C396 or ASTM C77 Fiber cement panels complying with ASTM C86 and with the ICC-ES Acceptance Criteria for Fiber Cement Siding Used as Exterior Wall Siding (AC90) Fiber cement panels complying with ASTM C325 and with the ICC-ES Acceptance Criteria for Reinforced Cementitious Sheets Used as Wall and Ceiling Sheathing and Floor Underlayment (AC376) Concrete-masonry complying with the code Concrete complying with the code Exposure wood structural panels complying with DOC PS- or PS-2 Brick masonry complying with the code 3.4 Water-resistive Barrier: The barrier must be one of the following: 3.4. Parex, El Rey and LaHabra WaterMaster House Wrap 366: A kraft building paper that conforms to the ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 208 ICC Evaluation Service, LLC. All rights reserved. Page of 5

ESR-689 Most Widely Accepted and Trusted Page 2 of 5 Grade D requirements of AC38 and has a 60-minute water-resistance rating. 3.4.2 Building Paper: Building paper must comply with ASTM D226, Type I asphalt-saturated felt. 3.4.3 Tyvek StuccoWrap: Tyvek StuccoWrap as described in ICC-ES report ESR-2375. 3.5 Sealants: Sealants must comply with ASTM C902, Type S or M, minimum Grade NS, minimum Class 25 and Use O. 4.0 DESIGN AND INSTALLATION 4. General: Parex USA Systems must be installed in accordance with the manufacturer s installation instructions, specifications and details. These are available at www.parex.com. 4.2 Drainage Options: Parex WaterMaster Insulation Board, LaHabra WaterMaster Insulation Board and El Rey WaterMaster Insulation Board, installed over a water-resistive barrier as described in either Section 3.4. or 3.4.2 Flat Insulation Board or WaterMaster Insulation Board, LaHabra WaterMaster Insulation Board and El Rey WaterMaster Insulation Board, installed over Tyvek StuccoWrap described in Section 3.4.3 4.3 Wind Design (See Table 2): Table 2 presents specific assemblies for which test data has been submitted. Other assemblies may be considered for approval by code officials based on testing and/or calculations by a qualified design professional. 4.4 Weather Protection: The Parex USA WaterMaster LCR system, LaHabra WaterMaster LCR system and El Rey WaterMaster LCR system comply with IBC Section 403.2 and IRC Section R703... 4.5 Fire-resistance-rated Construction: In Type V construction, the Parex USA WaterMaster LCR system, LaHabra WaterMaster LCR system and El Rey WaterMaster LCR system may be attached to the surface of combustible exterior fire-resistance-rated assemblies described in 205 and 202 IBC Table 72.(2) [2009 IBC Table 720.(2)] without changing the assigned hourly rating of the assembly. The exterior wall must have a minimum 0-foot (3048 mm) separation distance from adjacent construction. 5.0 CONDITIONS OF USE The Parex USA WaterMaster LCR system, LaHabra WaterMaster LCR system and El Rey WaterMaster LCR system described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section.0 of this report, subject to the following conditions: 5. Installation must comply with this report, the manufacturer s published installation instructions and the applicable code. In the event of a conflict between the manufacturer s instructions and this report, this report governs. 5.2 The insulation board must be separated from the building interior by a thermal barrier complying with the applicable code. 5.3 Installation must be by applicators acceptable to Parex USA, Inc. 5.4 Termination of the systems must not be less than 6 inches (52 mm) above finished grade, in accordance with 205 and 2009 IBC Section 2603.8 (202 IBC Section 2603.9) and IRC Section R38.4. 5.5 Adequacy of fasteners for concrete, masonry, brick or portland cement plaster substrates must be demonstrated to the satisfaction of the code official by a proof-load test program consisting of fastener withdrawal from the wall. The average withdrawal strength, in pounds, must be six times the required fastener load. 6.0 EVIDENCE SUBMITTED 6. Reports of tests in accordance with ASTM E2568 and ASTM E2273. 6.2 Data in accordance with the ICC-ES Acceptance Criteria for EIFS Clad Drainage Wall Assemblies (AC 235), dated January 205. 6.3 Data in accordance with the ICC-ES Acceptance Criteria for Foam Plastic Insulation (AC2), dated June 205. 6.4 Data in accordance with the ICC-ES Acceptance Criteria for Water-resistive Barriers (AC38), dated January 205. 7.0 IDENTIFICATION Each container or package of coating or reinforcing mesh used as part of the Parex USA WaterMaster LCR system, LaHabra WaterMaster LCR system and El Rey WaterMaster LCR system must be labeled with the Parex USA, Inc., name and address; the product name; lot or batch number; quantity of material; storage instructions; pot life; expiration date; and the evaluation report number (ESR-689). Parex WaterMaster Insulation Boards, LaHabra WaterMaster Insulation Board and El Rey WaterMaster Insulation Board must be labeled on the edge of each board with the Parex USA, Inc., name, the plant identification number, and the evaluation report number (ESR-689). Other foam plastic insulation must be labeled in accordance with the current ICC-ES evaluation report in which it is recognized, or must be labeled as noted in Section 3.2.

ESR-689 Most Widely Accepted and Trusted Page 3 of 5 TABLE SYSTEM COMPONENTS SYSTEM Parex WaterMaster LCR El Rey WaterMaster LCR or LaHabra WaterMaster LCR WATER-RESISTIVE BARRIER Described in Section 3.4. or 3.4.2 Described in Section 3.4.3 Described in Section 3.4. Described in Section 3.4.3 INSULATION BOARD WaterMaster Insulation Board Flat Insulation Board WaterMaster Insulation Board Flat Insulation Board BASE COATS Parex 2, or Parex 30 Insul-Bond REINFORCING MESH Standard Reinforcing Mesh, 4.5 oz/yd 2, minimum Standard Reinforcing Mesh, 4.5 oz/yd 2, minimum FINISH DPR Acrylic Finish 300 Series, or DPR Acrylic Finish 500 Series, or DPR Optimum Finish LaHabra Perma-Finish 300, El-Rey Perma-Flex DPR Type 2x4 Wood No. 8 gagesteel 2x4 Wood 3 5 / 8 -inch-by- No. 8 gagesteel N/A TABLE 2 WIND LOAD DESIGN FRAMING 4 SUBSTRATE EPS Spacing (inch) 6 6 N/A 2x4 Wood 6 Any sheathing described in Section 3.3, attached per code Min. 7 / 6 -inch wood structural panel, attached per code Concrete, concretemasonry, or brick masonry 7 / 6 -inch wood structural panel, attached per code 2x4 Wood 7 / 6 6 -inch wood structural panel, attached per code For SI: inch = 25.4 mm; psf = 0.0479 kpa. Minimum Thickness (inch) / 2 / 4 Attachment 2-inch-diameter Wind Devil Plates; Wind Lock WTI, No. 6 bugle head screws to framing; must penetrate -inch into wood framing or through steel framing; Pattern B Allowable Wind Load 2,3 (psf) 2-inch-diameter Wind Devil Plates; No. 8 Type W bugle head screws; must penetrate 8 / 2 -inch through sheathing; Pattern A 5 Wind Lock MT Screws; 2-inch-diameter Wind Devil 2 Plates; must penetrate substrate -inch; Pattern B 29 29 W-3 Wind Devil screws and plates; must penetrate / 2 -inch through sheathing; Pattern A 5 29 2 3 / 4 -inch Type W screws and Wind Devil II plates; Pattern A 5 3 Minimum 2x4 wood framing, minimum specific gravity 0.42 2 Maximum positive pressure is limited to the capacity of the framing and structural sheathing, or concrete, brick, masonry or Portland cement plaster substrate, determined in accordance with the applicable code. 3 Maximum positive pressure is limited to 55 psf (2.63 kpa) for gypsum sheathing complying with ASTM C396, and is limited to 4 psf (.96 kpa) for gypsum sheathing complying with ASTM C77, or to the capacity of the framing, whichever is lower. 4 The framing members must be designed to resist all positive and negative transverse design loads with a maximum allowable deflection of / 240 of the span. 5 Penetration into studs is not required for Pattern A.

ESR-689 Most Widely Accepted and Trusted Page 4 of 5 FIGURE FASTENING PATTERNS

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-689 FBC Supplement Reissued July 206 Revised April 208 This report is subject to renewal July 208. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 24 00 Exterior Insulation and Finish Systems Section: 07 24 9 Water-Drainage Exterior Insulation and Finish System REPORT HOLDER: PAREX USA, INC. 425 EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA 92807 (74) 778-2266 www.parexusa.com EVALUATION SUBJECT: PAREX USA WATERMASTER LCR SYSTEM, LAHABRA WATERMASTER LCR AND EL REY WATERMASTER LCR SYSTEMS.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Parex USA WaterMaster LCR system, LaHabra WaterMaster LCR system and El Rey WaterMaster LCR system, recognized in ICC-ES master report ESR-689, have also been evaluated for compliance with the codes noted below. Applicable code editions: 207 Florida Building Code Building 207 Florida Building Code Residential 2.0 CONCLUSIONS The Parex USA WaterMaster LCR system, Parex Standard WaterMaster system, LaHabra WaterMaster LCR system and El Rey WaterMaster LCR system, described in Sections 2.0 through 7.0 of the master evaluation report ESR-689, comply with the Florida Building Code Building and the Florida Building Code Residential, provided the design and installation are in accordance with the 205 International Building Code provisions noted in the master report and the following condition apply:. Design wind loads must be based on Section 609 of the Florida Building Code Building or Section R30.2. of the Florida Building Code Residential, as applicable. 2. Installation must meet the requirements of Section 403.8 of the Florida Building Code Building or Section R38.7 of Florida Building Code Residential, as applicable. Use of the Parex USA WaterMaster LCR system, LaHabra WaterMaster LCR system and El Rey WaterMaster LCR system for compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code Building and the Florida Building Code Residential has not been evaluated, and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder s quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued July 206 and revised April 208. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 208 ICC Evaluation Service, LLC. All rights reserved. Page 5 of 5