Fragment-based screening of enzyme drug targets: Microfluidic mobility shift assay improves confidence in candidate selection

Similar documents
Comparison of LANCE Ultra TR-FRET to PerkinElmer s Classical LANCE TR-FRET Platform for Kinase Applications

QS S Assist KINASE_MSA Kit

BoTest A/E Botulinum Neurotoxin Detection Kit- Detailed Description

Tyrosine Kinase Assay Kit, Red*

Synergy NEO HTS Multi-Mode Microplate Reader and Life Technologies Reagents

LabChip 90 System with DataViewer Software

Z -LYTE KINASE ASSAY KIT SER/THR 9 PEPTIDE PROTOCOL

Universal Kinase Assay Kit (Fluorometric) For monitoring ADP formation, which is directly proportional to enzyme phosphotransferase activity

Assessment of HDAC1 Inhibition Using an Automated, Bioluminescent Histone Deacetylase I/II Assay

Part. no. PV4319.pps Rev. date 29 June 2006

PI3 Kinase Assay Kit. Catalog Number KA assays Version: 05. Intended for research use only.

The World Leader in SPR Technology. Jimmy Page, PhD, Biacore, Inc.

QS S Assist STK_FP Kit

Label-Enhanced SPR Improves the Detectability of Label-Free Surface Plasmon Resonance Analysis 100x

Dr. Jeffrey P. Thompson bio350

Case Studies ZoBio

LabChip GXII: Antibody Analysis

SURFACE PLASMON RESONANCE-BASED SYSTEMS

Characterization of Aptamer Binding using SensíQ SPR Platforms

Sensitive protein:ligand biochemical assays using Corning Epic label-free technology on the EnSpire Multimode Plate Reader

Explore the future. Automotive Test Systems Process & Environmental Medical Semiconductor Scientific

HTRF KinEASE STK discovery kit

ab SIRT1 Activity Assay Kit (Fluorometric)

HIGH-THROUGHPUT SCREENING (HTS), a major component of

Innovative Pharmaceutical Solutions for Discovery Chemistry, Biology and cgmp Manufacturing

Kinetics Review. Tonight at 7 PM Phys 204 We will do two problems on the board (additional ones than in the problem sets)

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

ab Factor Xa Inhibitor Screening Assay Kit (Fluorometric)

High Throughput Quantitation of Cytokine Biomarkers using LANCE Ultra TR-FRET Assays

Automated, High Throughput, HTRF -Based Detection of Histone Methyltransferase and Demethylase Enzyme Activity

Optimization of a LanthaScreen Kinase assay for BRAF V599E

Label-free interaction analysis in realtime using surface plasmon resonance

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

HTRF KinEASE-STK S3 kit

CyBi -HummingWell. Compound Transfer Directly from Stock!

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

HTRF (Cisbio) Human Interleukin beta (IL1β) assay Tecan Infinite F500, TR-FRET (HTRF )

FlashPlate File #15. High Throughput Screening. J. Watson SmithKline Beecham Pharmaceuticals, UK.

5.36 Biochemistry Laboratory Spring 2009

EPIGENTEK. EpiQuik Histone Demethylase LSD1 Activity/Inhibition Assay Kit. Base Catalog # P-3076 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

Peptide libraries: applications, design options and considerations. Laura Geuss, PhD May 5, 2015, 2:00-3:00 pm EST

Quantitative analysis of PCR fragments with the Agilent 2100 Bioanalyzer. Application Note. Odilo Mueller. Abstract

Ultra High Throughput Drug Discovery Screening by MALDI-TOF Mass Spectrometry powered by Simultaneous 1536 well Pipetting

Corning Epic System. Applications. Therapeutic Application

Paul Bowyer. (Baker Lab, London School of Hygiene and Tropical Medicine)

ab MDR Assay Kit (Fluorometric)

Announcements. Next week s discussion will have a quiz on Chapter 3fg and Chapter 11ab Computer Lab (Chapter 11ab): 10/17 10/22

Roche Molecular Biochemicals Technical Note No. LC 10/2000

Solvent Correction versus In-line Reference Measurement

Shuo Wang, Manoj Munde, Siming Wang, W. David Wilson

Masayoshi Honda, Jeehae Park, Robert A. Pugh, Taekjip Ha, and Maria Spies

ab Plasmin Inhibitor Screening Assay Kit (Fluorometric)

Biacore System description. GE Healthcare. Biacore label-free interaction analysis. Optional software packages

HDAC-Glo I/II Assay and Screening System

ab Plasmin Activity Assay Kit (Fluorometric)

Data Sheet. PD-1[Biotinylated]:PD-L2 Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Calcium Assay Kit. Technical Data Sheet. Product Information. Description. Storage. Materials not included

ab Methylated DNA Quantification Kit (Colorimetric)

Applied Protein Services

Development of FRET-based Ion Channel, GPCR, and Kinase Assays on the GENios Pro Multifunctional Reader from Tecan

Biacore 8K. One solution for small molecule and biotherapeutic screening/characterization. GE Healthcare. Label-free interaction analysis

Kinase Activity: a total solution

Nanobiotechnology. Place: IOP 1 st Meeting Room Time: 9:30-12:00. Reference: Review Papers. Grade: 50% midterm, 50% final.

Purification: Step 1. Lecture 11 Protein and Peptide Chemistry. Cells: Break them open! Crude Extract

Purification: Step 1. Protein and Peptide Chemistry. Lecture 11. Big Problem: Crude extract is not the natural environment. Cells: Break them open!

protein interaction analysis

Call for Pilot Project Applications Chemical Biology for Infectious Diseases NIH Center of Biomedical Research Excellence University of Kansas

#FD µl (for 200 rxns) Expiry Date: Description. 1 ml of 10X FastDigest Green Buffer. Store at -20 C

Biacore The high performance research system. Work with high sensitivity

Notes to accompany the slidecast on theory of SDS PAGE and Western blotting

Profiling Ligands Of GPCR Targets Using An Optical Biosensor With Dynamic Mass Redistribution Technology

Accurate and Automated cell confluence assessment in microplates

ab GFP ELISA Kit Instructions for Use For the quantitative measurement of GFP protein expression

Fully-Automated Workstation for Direct camp Enzyme Immunoassay Kit

2014 MS Thesis topics HES-SO Valais Wallis, Biotechnology Unit Prof. Simon Crelier

FlexStation 3 microplate reader

UV Fluorescence Polarization as a Means to Investigate Protein Conformational and Mass Change

Label-free, real-time live-cell assays for spheroids: IncuCyte bright-field analysis

The Viability of Cancerous vs. Non-cancerous Cells

FACS Blue LacZ beta Galactosidase detection kit

ab Adenosylhomocysteinase (AHCY) Inhibitor Screening Assay Kit (Fluorometric)

Histone Analysis. Histone Analysis

Data Sheet. PD-1:PD-L1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

ab Ubiquitylation Assay Kit

protein interaction analysis tech note 5367

Developing a Time-Resolved Fluorescence Resonance Energy Transfer (TR-FRET) Assay

O-GlcNAcase Activity Assay

ab83355 ATP Assay Kit (Colorimetric/ Fluorometric)

Tag-lite Tachykinin NK1 labeled Cells, ready-to-use (transformed & labeled), 200 tests* (Part# C1TT1NK1)

MMLV Reverse Transcriptase 1st-Strand cdna Synthesis Kit

Comparing the Agilent 2100 Bioanalyzer Performance to Traditional DNA Analysis Techniques

ab Fluo-8 No Wash Calcium Assay Kit

MicroRNA profiling directly from low amounts of plasma or serum using the Multiplex Circulating mirna Assay with Firefly particle technology

Microarray Industry Products

Protein Stability Analysis Using the Optim Patrick Celie NKI Protein Facility, Amsterdam

Surface Plasmon Resonance Systems

nanodsf 2bind: Your service provider for biophysical characterization of proteins Precisely revealing protein folding and stability

alamarblue Technical Datasheet

Biochemical Binding ADCC Assays Utilizing AlphaLISA Toolbox Reagents for the Characterization of higgs and FcγR1A

Transcription:

Fragment-based screening of enzyme drug targets: Microfluidic mobility shift assay improves confidence in candidate selection Introduction Fragment-based lead discovery is establishing itself as valuable approach for the discovery of novel small molecule leads. It relies on establishing a better understanding of the binding mechanism of a ligand for its binding partner by probing for hot spots on the protein target with small molecule fragments (typically <300 Daltons). Its simplicity is in the principle of building a pharmacophore from the ground up. Successful selection requires data on binding affinity as well as extensive SAR information provided by a variety of techniques including NMR, X-ray crystallography, SPR as well as other biophysical techniques. This information will ultimately yield valuable insights into the molecular recognition process that aid in the design of more selective and potent drugs with fewer off target effects. Fragment-based screening is not without its challenges, for example NMR is a gold standard technique but is often used for detailed follow-up of initial hits selected in biochemical assays, due to its low throughput and high protein consumption. On the other hand biochemical assays can provide important initial insights into the binding affinities, but these small chemical fragments typically have binding affinities in the 50 µm to low millimolar range. Therefore, they must be screened at much higher concentrations to detect these weak binding interactions. This results in solubility problems as well as high false positive and negative rates due to compound interference when using fluorescence-based biochemical assays. In addition most biochemical assays provide limited information on the differences in the binding mechanisms of fragments. This white paper describes the use of the microfluidic mobility shift assay as an alternative to traditional biochemical assays for fragment-based screening. In addition it has the capability to provide structural insights that compliment techniques like NMR. Introduction to the Microfluidic Mobility Shift Assay Caliper s Microfluidic Mobility Shift Assay (MMSA) technology is designed for in vitro enzyme assays. It combines the advantages of capillary electrophoresis and microfluidics providing direct measurement of substrate and product, rapid assay development and real time kinetic reads. The assay measures the changes in mobility of molecules that have been biochemically modified for example by phosphorylation, and deacytlation electrophoretically. As the reaction mixture that is sipped from a microplate well travels through the microfluidic channel containing an acrylamide gel the substrate and product are separated in a time resolved fashion. At the end of the channel an LED (470 nm) excites the fluorescent labeled molecules as they travel by the detection window and the amount of separated reaction components are measured (figure 1). 1

Figure 1. Schematic of mobility shift assay The MMSA has several advantages for fragment-based screening of enzyme drug targets: Fewer false positives Improved assay reproducibility Direct measurement of enzyme activity Identification of novel fragment binding mechanisms The technique has been utilized on a number of enzyme drug targets including protein kinases, lipid kinases, protein phosphatases, proteases, histone deacetylaes, and sirtuins. Direct Measurement of Enzyme Regulation The MMSA provides a direct readout of the product conversion and substrate remaining, a direct measure of enzyme inhibition (or activation). There is no need for coupling reagents (antibodies) or secondary enzymes; this dramatically reduces the likely hood of loosing valuable time and data due to assay artifacts. Since the technique is a separation based approach all the reaction components are identified (figure 2), unlike homogenous assays where the entire contents of the reaction are read simultaneously. This reduces the chances of false positives due to autofluorescence of the compound being screened, especially important when working at high concentrations typical of fragments. Figure 2. This trace of actual data readout from work done at EMD Serono shows 2 wells sipped from EZ Reader Screen. The Y-axis represents relative fluorescence intensity units and the X-axis represents time in seconds. The 2 peaks on the left show 20% conversion of substrate (458s) to product (476s) and the peak on the right (510s) shows 100% inhibition. 2

During assay validation scientists from EMD Serono intentionally selected compounds that exhibited a high degree of autofluorescence to see how they would affect the MMSA assay performance, they discovered that of 321 compounds with known interference problems in biochemical assays only 21 were detected in the MMSA and of those none affected the assay results 1. They also observed that a further advantage of the MMSA is the techniques ability to normalize the data for well to well substrate dispensing variations. This is done by reporting the data as a product/substrate ration and not as absolute peak heights. This eliminates errors due to dispensing variations. In addition the calculated peak sum (sum of substrate and product peak heights) provides a QC tool for monitoring substrate dispensing precision 2. In another study done by scientists at Novartis Institute for Biomedical Research in Basel, Switzerland several different biochemical assay platforms were assessed for their robustness to artifacts from fluorescence interference of fragments especially at high concentrations. It was determined that the MMSA was the most robust with respect to artifacts from autofluorescent and fluorescence quenching of fragments 3, (figure 3). MMSA technology appears to be immune to fluorescence interference EMD Serono 2 MSA should be the most robust method with respect to artifacts stemming from autofluorescent and fluorescence quenching fragments Novartis 3 Figure 3. Percent false positives and negatives from a trypsin study using NMR as a basis of comparison to fluorescence lifetime (FLT), fluorescence intensity (FI), mobility shift assay (MSA), surface plasmon resonance (SPR) including (gold bars) and excluding (blue bars) weakly soluble fragments. Mode of Action One of the most import advantages of the MMSA is that it can give insights into mechanistic differences of inhibition of fragments on enzymes and cofactors. This is important because it may reveal unique features that can result in the discovery of novel compound scaffolds. The assay technique is not sensitive to ATP concentrations so for ATP dependent enzymes such as kinases it is possible to screen using a range of ATP concentrations and identify ATP competitive, non-competitive, and uncompetitive inhibition. In addition when used for IC 50 s and in real time kinetic mode experiments can provide information that could normally remain unnoticed. This would include the effects of cofactors, covalent complex formation, slow on rates, and fragment insolubility. Scientists at the Tokyo University of Agriculture and Technology used the MMSA to assess inhibitors of WNK1 kinase. Comparison of dose-dependent inhibition at different ATP concentrations indicated that inhibitors were ATP competitive 4. In addition they discovered compound precipitation from 60 to 100 µm, (figure 4). 3

Figure 4. IC 50 curves for Tyrphostin 47 show no inhibition at higher ATP concentrations indicating that the compound might be ATP competitive. In addition the compound exhibited only 60% inhibition at the maximum dose due to compound insolubility at concentrations greater than 60 µm. Enzyme progress curves provide important information on the mechanism of inhibition which can lead to identification of novel inhibitors. Progress curves are easy to perform using the MMSA in the kinetics mode and consume less than.2 µl of reaction mixture for each time point. Work done at the Broad Institute with the modulation of histone deacetylase activity has lead to the discovery of both classical and slow-binding inhibitors for HDAC3 and HDAC6. This may explain the differences in HDAC inhibition observed in cell based assays 5, (figure 5). Figure 5. Classical vs Time-dependent Inhibition Scientists at Pfizer were using fragment based screening to identify small molecule modulators of PDK1 kinase 6. They were looking for both ATP competitive and allosteric inhibitors, specifically ligands for the PIF pocket which is a binding pocket which recognizes non-catalytic motifs. It had been demonstrated that small molecules could modulate activity. The MMSA was employed for the purposes of screening fragment activity along with a Kinase-Glo assay. Results measuring fragments that modulate activity through the PIF site using the MMSA were in agreement with the NMR competition assay; however the Kinase-Glo assay was not able to detect these compounds due to that fact that the PIF pocket was blocked by the PDKtide substrate. Caliper assay data and 19 F NMR assay data on the PIF pocket fragments and structurally related compounds identified them as potentially allosteric activators of PDK1 function Pfizer 6 4

The ability to make real time observations provides benefits in assay development as well. For example work done at EMD Serono on developing a protein tyrosine kinase assay indicated that there was an increase in the initial rate of enzyme activity when a cofactor was added 5 minutes prior to the initiation of the reaction, as compared to when the cofactor was added at the initiation 2, (figure 6). Figure 6. Increase in initial reaction rate (blue) with addition of cofactor 5 minutes ahead of time as compared to when cofactor was added at initiation (red) Summary LabChip EZ Reader The LabChip EZ Reader is a breakthrough benchtop instrument which facilitates kinase testing and other enzyme screening and profiling. When combined with ProfilerPro kits, a low cost, turn-key solution of lab-bench kinase panel profiling is provided. LabChip assays are separations-based, so the quality of results exceeds what is achievable in homogenous, wellbased assays. The LabChip EZ Reader runs kinase and enzymatic assays with a 4-Sipper microfluidics chip. Utilizing Caliper s widely adopted mobility shift microfluidics assay technology, the LabChip EZ Reader analyzes kinase activity by sipping stopped reactions from 96 or 384 well microtitre plates. Caliper s Mobility Shift Assay technology is designed for in vitro enzyme assays aimed at the drug discovery process. It combines the advantages of capillary electrophoresis and microfluidics providing direct measurement of substrate and product, rapid assay development and real time kinetic reads. The EZ Reader is the perfect platform for running kinase profiling with the Caliper ProfilerPro Kits. ProfilerPro Kinase Profiling kits consist of matched pairs of 384 well kinase assay and plates complete with substrates. The assay plates each contain 24 different kinases, pre-dispensed and frozen. The substrate plates contain the appropriate fluorescent labeled peptides and ATP. Using LabChip EZ Reader researchers can monitor enzyme reactions and kinase inhibitors over time, resulting in more detailed data resulting in using fewer reagents. The advantages of microfluidics technology with real time kinetic analysis include: simplified and accelerated assay development and optimization, calculation of K m and K i values from initial rates, and determination of enzyme linearity. 5

Reference: 1) Perrin D, Martin T, Cambet Y, et al. Overcomming the hurdle of fluorescent compounds in kinase screening: a case study. Assay Drug Development Technology (2004) 4:185-96 2) Perrin D, Fremaux C, Shutes A. Capillary microfluidic electrophoretic mobility shift assays: Application to enzymatic assays in drug discovery. Expert Opin. Drug Discovery (2009) 5(1): 1-3 3) Boettcher A, Ruedisser S, Erbel P, et al. Fragment-Based Screening by Biochemical Assays; Systematic Feasibility Studies with Trypsin and MMP12. Journal of Biomolecular Screening. Published online (20September 2010) 4) Yagi Y, Abe K, Ikebukuro K, et al. Kinetic Mechanism and Inhibition Characterization of WNK1 Kinase. Biochemistry (2009) 48; 10255-10266 5) Provencher L, Gale J, Cohen S, Palmer M, et al. Microfluidic Mobility-Shift Assays for Mechanistic Studies with HDAC Inhibitors. Poster Presented at Drug Discovery on Target, Boston, 2010. 6) Stockman B, Kothe M, Kohls D, et al. Identification of Allosteric PIF-Pocket Ligands for PDK1 using NMR-Based Fragment Screening and 1 H- 15 N Trosy Experiments. Chem Bio Drug Des (2009) 73: 179-188 Caliper Life Sciences Hopkinton, MA 01748-1668 TEL: (508) 435-9500 FAX: (508) 435-3439 Web: www.caliperls.com 6 2010 Caliper Life Sciences Corporation. All rights reserved. Caliper, the Caliper logo, EZReader, ProfilerPro and LabChip are registered trademarks of Caliper Life Sciences Corporation. All other trademarks contained herein are the property of their respective owners. EZ-MS-01 Dec 10