Engineered Systems & Designs TURBIDITY METER

Similar documents
OPERATING INSTRUCTIONS. Portable Turbidity Meter

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

HI Portable Logging Turbidity Meter with RS232. Instruction Manual MAN R1 08/05 HI LOG LOBAT DATE TIME CLR VIEW ON OFF STO

3. Add 0.4 ml of. 7. Use a TenSette

Bacterial Counts - Quantitative Analysis of Microbes

Global Water Instrumentation, Inc.

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit

Universal Tactical Light

Calcium and Magnesium; Chlorophosphonazo Rapid Liquid Method Method to 1000 µg/l Ca and Mg as CaCO 3 (ULR) Pour-Thru Cell

Owner s Manual & Safety Instructions

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

USEPA 1,2 Bicinchoninate Method 3 Method 8506 (CuVer 1) and Method 8026 (CuVer 2) 0.04 to 5.00 mg/l Cu Powder Pillows or AccuVac Ampuls

Instruction Manual HI Portable ph/ec/tds/ C Meters

8000 / 8100 ph Meters

64C Amplification Block. Instruction Manual

Oxygen Demand, Chemical

2020we/wi 1970-EPA 1970-ISO

Triton TR8 Turbidity Analyzer

Global Water Instrumentation, Inc.

Formazin 4000FTU / 1000EBC / 8200ppm

Opti-Check Handheld Fluorometer

Chem 2115 Experiment #9. Consumer Chemistry: Determining the Iron Content in Supplements

DJ Switch 10F V2 ORDERCODE 50365

Human Myostatin, ELISA Kit (MSTN)

USER'S GUIDE TO OPERATION

Human IL-1 alpha ELISA Kit

Forensics with TI-Nspire Technology

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015

HELIUM CADMIUM LASER INSTRUCTION MANUAL

Scope and application: For water, wastewater, seawater, brine solutions, produced waters and hydraulic fracturing waters.

Ti-Pure TITANIUM DIOXIDE. CONCENTRATED ACID SOLUBILITY OF TiO 2 METHOD: T WP

HYDRAULIC DOCK LEVELER OWNERS MANUAL

MEDIZINTECHNIK FÜR TIERÄRZTE

50 Watt LED Wall Pack Light - 500W Quartz Halogen Equivalent - (4) 12.5W High Output LEDs

Adjustable Fused Power Supply

Nitrogen, Simplified TKN (s-tkn ) DOC

Oxygen Demand, Chemical

7700 TEST KIT OPERATIONS MANUAL

TWO-DIMENSIONAL GEL ELECTROPHORESIS THE FIRST DIMENSION

Human IL-6 ELISA Set

COLORIMETRIC SANDWICH ELISA KIT INSTRUCTION MANUAL

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

BIOLOGY 163 LABORATORY. RESTRICTION MAPPING OF PLASMID DNA (Revised Fall 2017)

Please read and follow the instructions below carefully to ensure proper setup and avoid problems.

Global Water Instrumentation, Inc.

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters

DIGITAL PORTION SCALE PS-5 OWNER S Manual

3500 Series Yellow Jacket Mild Steel Floor Scale

Soil Volume Change Meter (PVC)

HY-ALERTA 500 Handheld Hydrogen Leak Detector

Using the PPM2 Portable Trace Moisture Transmitter

INTRODUCTION TO ELECTROCHEMISTRY: CURRENT, VOLTAGE, & BATTERIES. Introduction. Electrochemistry Revised 4/28/14

Global Water globalw.com

Magner /35-3 Series Currency Counter. Operator's Manual

Water-Water Titration for the MicroCal ITC200

LIFluor EnhanCE. for use with dsdna 1000 and dsdna 20,000 Kits

Instruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives.

AHP WELDS USER MANUAL

Human Angiotensin 2 (Ang2) ELISA

QA-ES Automation Bundle

P URE PRO DRINKING WATER SYSTEM USER'S MANUAL REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

The Biology CRO. Protein Staining System. For electric staining of proteins in mini polyacrylamide gels. Version 1.0 April 3, 2010.

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

ph AND REFERENCE ELECTRODE USER MANUAL

QuantiFluor ONE dsdna System

Wireless Freezer Manual Installation Guide

User s Manual. Chart Projector GCP-7000

Salinity in Seawater

Adam Equipment ADK SERIES

RJE INTERNATIONAL, INC. U LB-364EL R EV 3.2

WS 10 Weighing indicator USER MANUAL

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Owner s Manual & Safety Instructions

Navigating the Turbidity Units Standards Around Water Quality Monitoring

FILTRATION & UV SYSTEM

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

HCP-7000 Opreator s Manual 1. Operator s Manual.

Next Generation Science Standards NGSS Science and Engineering Practices: NGSS Cross-cutting Concepts: NGSS Disciplinary Core Ideas:

Global Water globalw.com

RJE INTERNATIONAL, INC.

Sby SR Instruments, Inc.

Module 2, Add on Lesson Turbidity Sensor. Student. 90 minutes

Agilent RNA 6000 Nano Kit Guide

Instructions for Use Reprocessed Balloon Inflation Devices

TSI Model 3063 Thermal Mass Flowmeter

Stopwatch Display Timer Owner s Manual

Human Amyloid Beta Peptide 1-42 (Aβ1-42) ELISA Kit

Principles of Gel Filtration Chromatography

Bovine IgG ELISA Kit

Canine Creatinine(Cr) ELISA kit. Catalog No. MBS (96T)

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Instruction Manual HI 2210 HI Microprocessor-based ph/mv/ C Bench Meters.

Model M120 Mini Temperature/Humidity Meter

Transcription:

Engineered Systems & Designs TURBIDITY METER Operator s Manual for Model 800 Turbidimeter Model 800 with Optional Battery Pack and Carrying Case INDEX Specifications for Turbidity.................. 1 Introduction.............. 1 Preparation of Turbidity-Free Water Reference Standard... 1-2 Preparation of Primary Standards... 2 General Operating Instructions... 3 Calibration Procedure Using Primary Standardized Solutions... 3 Calibration Procedure Using Secondary Standardized Solutions... 3 Battery Operation... 4 Maintenance... 4 Replacement Parts... 4 Service... 4 800 & 800P Instructions.cdr

Specifications for Turbidimeters Models 800 and 800-P and 0-200 NTU. These meters are designed to remain on permanently. However, during long periods of non-use, it Meter: is recommended the units be switched off to prolong lamp Range: 0-19.99 and 0-199.9 NTU life. If switched off, they will require approximately 30 Accuracy: +/- 2% or 0.05 NTU minutes for warm-up. Display: 0.5 LCD Handle the sample vials with extreme care. Discard any Photometric Data: vials with scratches. It is important that the vial, especially Photodetector: 2 photo voltaic cells, centered at 90 the bottom, be wiped clean with lint-free tissues before degrees to the incident light path, spectral peak inserting into the reading chamber. To avoid smudges, response between 400 and 600 nm. handle all vials by the top of the vial only. The vials measure 20 X 70 mm. Lamp: Tungsten, lens-end 3.5 volt, operating at a color temperature of 2230 degrees K. Distance On the side of each sample vial is a vertical white index traversed by incident light and scattered light within line. Make sure this index line faces the exact same the sample tube is 2.5 cm. position every time you insert the sample vial into the test chamber. If the index line is not in the same position, the Control Panel: reading on the meter will change; not because of the change Range Selector: 3 Positions: OFF/0-20 NTU/0-200 NTU in the test solution, but because of the varying optical Zero Control: For calibration to 0 NTU characteristics of the sample vial. You can verify this glassware effect by rotating the sample vial in the test Power Requirements: chamber. You will notice the meter readings change. Line Operated: 120 volts, 50/60 Hz Battery: 12-volt sealed battery with battery pack Caps for the sample vials are provided. These caps should be placed on the sample vials before the vials are put into Meter Housing: the reading chamber to prevent any accidental spilling of Material: Aluminum the contents into the chamber. The chamber should be kept Dimensions: 9.25L x 6.66W x 3.20 H dry and clean at all times to insure accurate readings. Weight: 3 lbs, Model 800; 9 lbs, Model 800-P Turbidity samples and standards should be thoroughly mixed before inserting either into the reading chamber. All bubbles should be removed, either by allowing the vial to Introduction stand for a few minutes or by gently tapping and swirling the contents. Models 800 and 800-P meet EPA specifications for measurement of turbidity in drinking water. Their driftcause considerable fluctuation in the meter s readings as the Particulate matter, such as dust or lint in the sample, will free, accurate readings make these instruments suitable for testing municipal water, food and beverage processing, and particles come into the path of the light beam. In most any aqueous solutions in which control of clarity is critical. cases, the meter s readings will waver between a steady reading and a higher reading. The reading will eventually Models 800 and 800-P are true nephelometers, measuring fluctuate back down to a lower reading as the particles the amount of light scattered at a right angle from a beam of settle. When this type of reading is evident, it is best to light passing through the test sample. Test results are read remove the light shield and examine the sample. directly in NTUs on a LCD digital readout. The turbidimeters are pre-calibrated and a simple zero adjustment is the only steps required prior to testing. Preparation of Turbidity-Free Water Reference Standards Cover the sample vial and chamber when a reading is taken. To prevent dust accumulation, leave the light shield in place The filter holder and syringe must be conditioned, by on the instrument when it is not in use. Do not store sample forcing at least two syringe loads of deionized water vials in the chamber. through the filtering mechanism to remove foreign matter from the filtering apparatus. The first and second rinses are A function control switch turns the instrument ON and also discarded. serves as the range selector for the two ranges: 0-20 1

Turbidity-free water, as prepared below, may be stored in the dark, at room temperature, in a clear glass bottle with a screw cap, or in a turbidity vial and used as required. The storage vessels should be rinsed thoroughly with filtereddeionized water. Periodically inspect the water for foreign matter in a bright light. Procedures for Making Triple Filtered Distilled Water 1. Remove the plunger from the syringe and attach the filter holder to the bottom of the syringe. The standard Amco Clear solution has a value of 400 NTU. This solution is used as the stock solution and is stable for one year. Dilutions of the stock solution are made with turbidityfree water as prepared in the instructions following. A working standard is prepared by pipetting exactly X ml of the stock solution into a clean, volumetric flask and diluting to 100 ml. The working standard has an NTU value of X NTU and is stable for one year. See table below. The following table gives the relationship between dilutions of the 400 NTU solution and the resulting values as NTU. When diluting the suspension, use only turbidity-free, triplefiltered, deionized water. 2. Pour approximately 50 ml of deionized water into the NTU ml of 400 NTU Solution (diluted to 100 ml with turbidity-free water) barrel of the syringe, replace the plunger into barrel and exert pressure on the plunger to slowly force the Stock DI Water water through the filter. Collect the water in a 400 ml ml suitably clean container. 200 50.0 50.0 50 12.5 87.5 3. Remove filter holder from syringe then remove 20 5.0 95.0 10 2.5 97.5 plunger from barrel of the syringe. This procedure is 1 0.25 99.75 required to prevent rupturing the membrane filter by the vacuum created as the plunger is removed from the barrel. Dilution of Sample 4. Replace filter holder and repeat Steps 3 and 4 until If the sample has a turbidity reading greater than 200 NTUs, it the desired amount of turbidity-free water is collected. is necessary to dilute the sample with turbidity-free, deionized Periodically examine the membrane filter to insure no water to bring the reading within range of the instrument. holes or cracks are evident. Turbidity-free, deionized water may be prepared as described above. The following calculation is required if the sample is 5. Repeat Steps 1 through 4 using the 1X filtered water diluted. obtained in Step 4. This will give you 2X filter water. 6. Repeat Steps 1 through 4 using the 2X filtered water of Step 5. This will give you 3X or triple-filtered water. 7. Depending up on the nature of the unfiltered water, it is possible to prepare a liter or more of turbidity-free water using a single filter. The membrane filter may be stored in the holder for an indefinite period of time and used as required. Preparation of Amco Clear Standards Calibration of the Models 800 and 800-P are based upon Amco Clear, a suspension which is more reproducible in its light-scattering properties than any other suspension. These meters have been calibrated to Amco Clear solutions by the factory and the calibration should not change with time. However, should the instruments indicate a need for calibration, it may be accomplished in the laboratory by using carefully prepared Amco Clear solution as noted: A x (B+C) = D C Where A = NTU found in diluted sample B = Volume of deionized water used, ml C = Sample volume taken for dilution, ml D = NTU of original, undiluted sample For example, if 10 ml of sample water is diluted with 90 ml of turbidity-free water to a total volume of 100 ml and the resulting solution measures 40 NTU, the turbidity of the original undiluted sample is: 40 (90 + 10) = 400 NTU 10 2

General Operating Instructions 1B. Set the panel Zero Control knob at mid-range, so the arrow on the knob points at the letter o on the word Control. Locate the coarse zero potentiom- eter. It can be found on the right side of the instrument and is marked 0. With a small screwdriver, set the coarse zero pot so that the meter reads as closely to zero (o) as possible. An exact zero can now be set with the Zero Control knob. 1. First, attach the AC wall adapter s 3.5 mm plug into the instrument s jack located on the rear panel of the instrument. The AC wall adapter converts 120 volts AC to 12 volts DC, 500 milliamps. Allow Model 800 or 800-P to warm-up for 30 minutes. 2. Insert a sample vial (20x70mm) containing a turbidity-free zero (0) reference of either triple filtered water or a 0 NTU primary standard into the chamber and replace the light shield. Ensure cap is on vial. Permanently sealed secondary standards of 0 NTU and 10 NTU values are available for purchase from the manufacturer. Please refer to the replacement parts section on the last page. 3. Rotate the range switch to the 20 position, and with the zero adjustment knob adjust meter to read 0.0. For multiple samples, it is not necessary to reset the zero for each sample. 4. Remove the zero standard from the chamber and insert the test sample. Ensure cap is on the vial. 5. Replace light shield. 6. Rotate switch until appropriate range is selected for reading the sample. If the meter shows a 1, it is over-ranged. Change the range switch to the 200 range. If the reading is greater than 200 NTU, dilute the sample by 1/2 to obtain reading and multiple results by 2, or see page 2 for dilution instructions. 7. Remove sample from chamber and replace light shield. Samples should never be allowed to remain in the chamber for extended periods of time. Calibration Procedure Using Primary Standardized Solutions Although each instrument is pre-calibrated before it leaves the factory, it may be necessary to check the calibration to determine if the instrument is responding according to the specifications. The instrument should be allowed to warm-up for 30 minutes. Please read the instructions thoroughly before starting. Procedure: 1A. Insert a sample vial with turbidity-free, triple filtered, deionized water standard in the chamber and cover. Set the range switch to 20 NTU. Set the Zero Control potentiometer on the instrument panel so that the meter reads 0.0. If the meter cannot be made to read zero (0), then go to Step 1B; if the meter does read zero, then go to Step 2. 2. Insert a 10 NTU primary standard solution into the chamber and cover. Set the range switch to 20. If the meter does not read 10.00, adjust the potentiometer marked 20, found on the right side of the instrument, with a screwdriver until the meter reads 10.00. The digit 1 will appear in the display when the instrument is over-range, that is over 19.99. 3. With the 10 NTU primary standard solution in the chamber and covered, set the range switch to 200. If the meter does not read 10.00, adjust the potentiometer marked 200, found on the right side of the instrument, with a screwdriver until the meter reads 10.00. The digit, 1 will appear in the display when the instrument is over-range, that is over 199.9. 4. Repeat Steps 1-4 if necessary. The instrument is now calibrated in both ranges. Secondary Standards Secondary standards are an easy way to calibrate your instrument on a daily basis. The secondary standards are sealed and permanent. The secondary standards need to be calibrated when first used and then every six months thereafter. Once the values of the sealed secondary standards have been determined, you use these values for six months. After six months, you must perform a primary calibration on the instrument using primary standards and then re-establish the secondary standard s value for the next six months. Procedure: 1. Calibrate the instrument using primary standards. 2. Do Not make any changes to the instrument. 3. Insert the 0 NTU secondary standard. It will not read 0.00. The value will be close to zero but most likely it will not read zero. For example, the 0 NTU could read as -0.1 or +0.2 NTU. WRITE DOWN the displayed value of the 0 NTU. This value will be what you calibrate the meter to for the next six months using the 0 NTU sealed secondary standard. 4. Insert the 10 NTU secondary standard. It will not read 10.00. The value will be close to ten but most likely it will not read ten. For example, the 10 NTU could read as 9.8 or 10.2 NTU. WRITE DOWN the displayed value of the 10 NTU. This value will be what you calibrate the meter to for the next six months using the 10 NTU sealed secondary standard. 3

Model 800-P Battery Operation CAUTION - CAUTION - CAUTION - CAUTION The enclosed battery pack stores a large amount of energy. Do not allow anything to short out the battery s plug. Treat this battery with the same respect and caution given to a car battery. Failure to do so may result in damage or injury to you or the instrument. Model 800-P turbidity meter has a battery pack. The battery pack is a sealed, gel-filled, 12-volt DC, 1.9 amp hour battery. The battery is permanently mounted in a luggage-type carrying case and is connected to the turbidity meter via a six-inch long double-ended plug. Either model can be used in the laboratory with the AC wall adapter supplied with the meter or in the field with the battery pack. 3 interfere with turbidity readings. If any solution is spilled into the chamber, remove the spilled fluid immediately with an absorbent towel. Wipe clean with a lint-free cloth or tissue. Replacement Parts The following is a list of replacement parts available for Models 800 and 800-P: 01-TUR-CAP...Turbidity cap (light shield) 01-TUR-FILTER......Filter, 0.2 micron disposable 01-TUR-400NTU... 400 NTU primary Amco standard 01-TUR-SYRINGE... 50cc syringe 01-TUR-VIAL......20x70 mm, flat bottom, with cap 01-TUR-0NTU...0 NTU secondary sealed Amco standard 01-TUR-10NTU... 10 NTU secondard sealed Amco standard 01-LMP-L1006......Lamp, 3.5 volt 01-ADAPTER-500 MA...AC Adapter 12 volts DC 500 ma 01-TUR-BATT...Rechargeable battery pack with carrying case and secondary standards : 0 & 10 NTU Service Battery Pack Operation: In the event you need factory service, please call for a To use the battery pack, insert the double-ended plug Return Goods Authorization number. Included with the between the battery jack and the 3.5 mm AC adapter jack returned items should be information concerning its serial found on the back of the meter. A fully-charged battery number, specific reason for return, name of a contact should provide 90 minutes of continuous operation or person, telephone number and return address (no P. O. Box approximately 180 random samples. To conserve battery numbers). Returns should be made to the following power, we recommend the meter be turned on for a test and address: then turned off immediately afterwards. Engineered Systems & Designs, Inc. Charging the Battery: 119 A Sandy Drive To charge the battery, take the plug of the AC wall adapter Newark, DE 19713-1148 U.S.A. and insert it into the battery jack. It will take 24 hours to phone: 302-456-0446 fully charge the battery. The battery is fully charged at the fax: 302-456-0441 factory before shipping. email: esd@esdinc.com web: www.esdinc.com Maintenance Any instrument requiring repair, within the warranty period, must be returned to Engineered Systems & Designs for appropriate inspection and necessary repair. Out-of- warranty repairs and non-warranty repairs will be invoiced based on cost of parts and labor. Replacing Light Bulb: Unplug instrument from receptacle. Remove the four screws from the bottom of the turbidity meter and one on the left and right side. Lift the instrument housing from the base. The top part of the instrument housing contains the light box from which the bulb and lead wires can be removed. Unscrew (conter-clockwise) the black barrel which holds the lamp. Carefully disconnect the wire leads going to the lamp from the printed circuit board by unscrewing the wire nuts. Attach the new bulb leads using the wire nuts, and place the bulb back into position in the light box. Place the instrument housing over the base and replace the six screws. Plug the instrument into a receptacle. The optical characteristics of each bulb are carefully controlled, but to insure accurate results it may be necessary to calibrate the instrument according to the instructions on page 3. Any instrument received for repair, with serial numbers indicating manufacture and sale outside the stated warranty periods, will be repaired at cost or returned as is. All products being returned shall be repaired at reasonable cost or replaced at the discretion of Engineered Systems & Designs and will not, under any terms, be accepted for credit. Allow a 5-7 day window for repairs. Our policy is to return warranty repairs via UPS Ground. If you need the instrument in a rush, you will have to agree to pay for the freight service you choose. Cleaning the Light Box: 4 Periodically clean the light box chamber with a lint-free cloth or tissue to remove foreign matter which may