ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

Similar documents
ESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

EDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)

ESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

ESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

SED-501. Sightproof Louver Drainable Blade. Application and Design

EDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

EAD-635. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost)

ESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-130S. Thin-line Louver Frameless. Application and Design. Standard Construction. Options (at additional cost)

ESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)

Stationary Louvers. Product Type Model Description EDD-401, 601 ESD-202, 403, 435, 603, 635 EDJ-202, 401, 430, 601 EDK-402, 430, 602 ESID-430

ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing

Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.

EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER

Wall Louvers (10200)

SPECIFICATION SECTION PART 1 GENERAL

SECTION ALUMINUM WINDOWS

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

Severe Duty Louvered Products. Miami-Dade County Qualified, Florida Product Approved, Wind-Driven Rain, FEMA 361 and Sand Louver

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

Brise Soleil Fixed Sunshades

SPECIFICATIONS: Architectural Aluminum Railings

Louvers, Screens & Grilles /RUS BuyLine 3966

TMS 152 / 152T / 152XT TECHNICAL MANUAL

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

TMS 114 XT TECHNICAL MANUAL

SECTION EXTERIOR GRILLS AND SCREENS

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

SECTION ALUMINUM STORM WINDOWS

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION EXPANSION CONTROL

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Ultra Aluminum Fence, Rail & Gate Specifications

ALL-ALUMINUM DOOR & WINDOW FRAMING

SECTION DIRECTORIES

SECTION SECTIONAL OVERHEAD DOORS

where high efficiency is the standard

SECTION IMPACT RESISTANT WALL PROTECTION

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Architectural Coatings. to HVAC and Life Safety. A Balanced Approach

SECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.


A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

SECTION DECORATIVE METAL AND GLASS RAILING

A. Access doors and frames are part of an access door and frame allowance.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SWING DOOR SPECIFICATION

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

Corium Brick Rainscreen System Specifications

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

Code Compliance Research Report CCRR-0194

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

SECTION COLUMN COVERS

Aluminum Component Pipe Railings

Specifications for FL-100 Soffit Panel

Product Evaluation Report of. JELD-WEN, inc. Energy Saver/Contour Wood Edge Opaque Steel Outswing Door w/ or w/o Sidelites

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

TRIAD CORRUGATED METAL, INC.

TRANSPORT II " 10.5" MOUNTING POSTS FENCE LINE POST. Classic gate shown GATE OPENING CANTILEVER GATE SAFETY WARNING

Comparison letter for MegaMet s MegaStorm Door against door construction details in FEMA 361 section 7.4.1

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

Oshkosh CorGuard FRP Doors and Frames.

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

AQUARIUS CONDOMINIUM 40 YEAR RESTORATION PROJECT & RELATED WORK. Wind Pressure Drawings: Openings, Specs, NOA s / Product Approvals

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

CENTRIA FORMABOND II Metal Composite Wall System

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SL150 Guide Specification

Embry-Riddle Aeronautical University Signage Specifications 03/25/2008

SECTION TURBINE VENTILATORS

ATI Evaluation Service A Division of Architectural Testing Certification Services

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

Blast Curtain Wall Installation Analysis

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

ATI Evaluation Service A Division of Architectural Testing Certification Services

Transcription:

Application and Design Florida Product Approved Drainable Blade Louver is a Florida Product Approved stationary drainable blade extruded aluminum louver designed to protect air intake and exhaust openings in building exterior walls. is tested in accordance with AMCA 500-L Air Performance and Water Penetration. is tested in accordance with AMCA 540 Test Method for Louvers Impacted by Wind Borne Debris (Basic Protection, Missile Level D). is licensed to bear the AMCA seal allowing design professionals to select and apply with confidence. is tested and qualified per the following Florida test protocols: TAS 201 (Large Missile Impact), TAS 202 (Uniform Static Air Pressure) and TAS 203 (Cyclic Wind Loading). is approved by Florida for use in Florida s High Velocity Hurricane Zone. is qualified for wind loads up to 200 PSF (size and configuration dependent, refer to the UL published certification for size and design load rating restrictions). Standard Construction Frame........Heavy gauge extruded 6063-T5 aluminum, 4 in. x 0.081 in. nominal wall thickness Blades........Horizontal rain resistant style, heavy gauge extruded 6063-T5 aluminum, 0.081 in. nominal wall thickness, positioned at 37.5º angles on approximately 3¼ centers Construction... Mechanically fastened Birdscreen.....3/4 in. x 0.051 in. flattened expanded aluminum removable frame, inside mount (rear) Finish.........Mill Angles........ Continuous, Ship Loose (mill finish) Minimum Size..12 in. W x 9 in. H Maximum Single Section Size... 84 in. W x 144 in. H. or 120 in. W x 84 in. H. *Width and height dimensions furnished approximately ¼ inch under size. Qualified Shapes Options (at additional cost) A variety of bird and insect screens Blank-off panel Extended sill Filter rack Flanged frame Security bars Welded construction (Large Missile Impact Qualified) 0.125 in. nominal wall thickness Qualified shapes (only rectangular shapes maintain AMCA licensed performance data) A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel paint Kynar paint Anchor points

PERFORMANCE DATA Free Area Chart (Sq. ft.) Louver Height Inches Louver Width in Inches 12 18 24 36 42 48 60 66 72 84 90 96 108 114 120 9 0.15 0.24 0.34 0.53 0.63 0.73 0.90 0.99 1.09 1.28 1.38 1.47 1.64 1.74 1.84 12 0.29 0.48 0.66 1.04 1.23 1.41 1.74 1.93 2.12 2.49 2.68 2.87 3.20 3.38 3.57 24 0.79 1.31 1.82 2.85 3.36 3.87 4.77 5.29 5.80 6.83 7.34 7.86 8.75 9.27 9.78 30 1.05 1.72 2.40 3.76 4.44 5.12 6.30 6.98 7.66 9.02 9.70 10.38 11.56 12.24 12.92 42 1.56 2.57 3.58 5.60 6.61 7.62 9.39 10.40 11.42 13.44 14.45 15.46 17.23 18.24 19.25 48 1.84 3.03 4.22 6.60 7.79 8.98 11.06 12.25 13.44 15.82 17.01 18.20 20.29 21.48 22.67 60 2.35 3.88 5.40 8.46 9.98 11.51 14.18 15.71 17.23 20.28 21.81 23.34 26.01 27.53 29.06 66 2.61 4.29 5.98 9.36 11.05 12.74 15.70 17.39 19.08 22.46 24.15 25.84 28.80 30.49 32.18 78 3.12 5.14 7.16 11.20 13.22 15.25 18.78 20.81 22.83 26.87 28.89 30.91 34.45 36.47 38.50 84 3.38 5.57 7.77 12.15 14.35 16.54 20.38 22.57 24.76 29.15 31.34 33.54 37.38 39.57 41.76 96 3.91 6.45 8.99 14.07 16.61 19.14 23.59 26.13 28.66 33.74 36.28 38.82 43.26 45.80 48.34 102 4.17 6.87 9.57 14.97 17.67 20.38 25.10 27.81 30.51 35.91 38.61 41.31 46.04 48.74 51.45 114 4.68 7.71 10.74 16.81 19.84 22.88 28.19 31.22 34.25 40.32 43.36 46.39 51.70 54.73 57.77 120 4.93 8.13 11.33 17.73 20.93 24.13 29.72 32.92 36.12 42.52 45.72 48.92 54.52 57.72 60.91 132 5.39 8.89 12.38 19.37 22.87 26.37 32.49 35.98 39.48 46.47 49.97 53.46 59.58 63.08 66.57 138 5.64 9.29 12.95 20.26 23.92 27.57 33.97 37.63 41.28 48.59 52.25 55.91 62.30 65.96 69.62 144 5.88 9.70 13.52 21.15 24.97 28.78 35.46 39.28 43.10 50.73 54.55 58.36 65.04 68.86 72.68 Greenheck Fan Corporation certifies that the ESD- 435X louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance and water penetration ratings. Greenheck Fan Corporation certifies that the louvers shown herein are approved to bear the AMCA Listing Label. The Ratings shown are based on tests and procedures performaned in accordance with AMCA Publications and comply with the requirements of the AMCA Listing Label Program. The AMCA Listing Label applies to Wind Borne Debris Impact Resistant Louvers. Airflow Resistance (Standard Air -.075 lb/ft 3 ) Water Penetration (Standard Air -.075 lb/ft 3 ) Pa in. wg 1 ml/m2 oz/ft2 0.9 200 0.8 Test Size 48 in. x 48 in. 0.30 0.7 Standard Air -.075 lb/ft 3 Test Size 48 in. x 48 in. 0.6 Test Period 15 minutes 0.5 80 0.25 Standard Air -.075 lb/ft 3 Static Pressure Drop 100 90 80 70 60 50 40 30 20 0.4 0.3 0.2 0.1 0.09 0.08 0.07 0.06 Intake Exhaust Water Penetration per Unit Free Area 60 40 20 0.20 0.15 0.10 0.05 0.05 10 9 8 7 6 5 0.04 0.03 0.02 ft/min m/s 200 300 400 500 600 700 800 900 1000 2000 3000 2 3 4 5 6 7 8 9 10 Free Air Velocity Model resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. See louver selection information. (Test Figure 5.5-6.5) 0 0.00 ft/min: 1000 1050 1100 1150 1200 1250 1300 m/s: 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6.0 6.1 6.2 6.3 6.4 6.5 6.6 Free Area Velocity The AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through.01 oz. of water (penetration) per sq. ft. of louver free area. * The beginning point of water penetration for Model is 1151 fpm free area velocity. These perfor mance ratings do not guarantee a louver to be weather proof or stormproof and should be used in combination with other factors including good engineering judgement in selecting louvers.

INSTALLATION DETAILS Maximum Size and Installation Information Model is a Florida Product Approved louver and must be installed in accordance with the installation instructions shown herein. Model is qualified for installation within masonry, steel stud, structural steel or wood framed building conditions. Model is structurally calculated to withstand positive and negative wind-loads up to 200 PSF. The louver section size will determine the actual maximum wind-load that the louver sections will withstand. The maximum single section size can be either 84 in. W x 144 in. H or 120 in. W x 84 in. H. The maximum opening width may be unlimited as multiple sections may be installed side by side in accordance with installation instructions. Wood Opening Minimum Single Section Size 12 in. W x 9 in. H Maximum Single Section Size 84 in. W x 144 in. H. or 120 in. W x 84 in. H. Masonry Opening

INSTALLATION DETAILS Steel Stud Opening Structural Steel Opening FASTENER SCHEDULE (FIELD INSTALLED - NOT BY GREENHECK) MOUNTING SUBSTRATE FASTENER TYPE DESCRIPTION ANCHOR CLIP LOCATION QUANTITY MIN. EMBED. MIN. EDGE DIST. MIN. SPACING WOOD A 1/2" DIA. LAG SCREW JAMB VARIES 3" 2 1/2" 6.5" WOOD B 1/4" DIA. LAG SCREW VERT. MULLION (HEAD/SILL) 12 PER CLIP 3" 1/2" 2" CONCRETE C1 1/4" DIA. TAPCON ANCH. JAMB VARIES 1.25" 1" 3.25" CONCRETE C2 1/4" DIA. TAPCON ANCH. VERT. MULLION (HEAD/SILL) 7 PER CLIP 1.75" 2.5" 2" MASONRY BLOCK C1 1/4" DIA. TAPCON ANCH. JAMB VARIES 1.25" 1" 3.25" MASONRY BLOCK C2 1/4" DIA. TAPCON ANCH. VERT. MULLION (HEAD/SILL) 7 PER CLIP 1.75" 2.5" 2" STEEL STUD D & E 1/4" DIA. BOLT & NUT JAMB VARIES THRU BOLT 1/2" 6.5" STEEL STUD (3/16" STEEL REINFORCED) F 1/4" DIA. DRILL FLEX JAMB VARIES FULL 1/2" 6.5" STEEL STUD G 1/4" DIA. DRILL FLEX VERT. MULLION (HEAD/SILL) 12 PER CLIP FULL 1/2" 2" STRUCTURAL STEEL D & E 1/4" DIA. BOLT & NUT JAMB VARIES THRU BOLT 1/2" 6.5" STRUCTURAL STEEL D 1/4" DIA. BOLT JAMB (FIELD DRILL & TAP HOLE) VARIES FULL 1/2" 6.5" STRUCTURAL STEEL F 1/4" DIA. DRILL FLEX JAMB VARIES FULL 1/2" 6.5" STRUCTURAL STEEL D & E 1/4" DIA. BOLT & NUT VERT. MULLION (HEAD/SILL) 4 PER CLIP THRU BOLT 1/2" 6.5" STRUCTURAL STEEL D 1/4" DIA. BOLT VERT. MULLION (HEAD/SILL) FIELD DRILL & TAP HOLE 4 PER CLIP FULL 1/2" 6.5" STRUCTURAL STEEL F 1/4" DIA. DRILL FLEX JAMB VARIES FULL 1/2" 6.5" GENERAL NOTES: 1. IT SHALL BE THE RESPONSIBILITY OF THE PERMIT HOLDER TO VERIFY THE STRUCTURAL INTEGRITY OF THE EXISTING STRUCTURE TO SUPPORT THE LOADS SUPERIMPOSED BY THE LOUVERS. 2. INSTALLER TO PROVIDE SEPARATION OF DISSIMILAR MATERIALS AS REQUIRED. 3. WOOD SUBSTRATE TO BE MINIMUM G = 0.42 DENSITY. 4A. CONCRETE SUBSTRATE TO BE MINIMUM 3,192 PSI CONCRETE OR 3,192 PSI GROUT FILLED ASTM C-90 HOLLOW BLOCK AT HEAD/SILL MULLION ANCHORS. 4B. CONCRETE SUBSTRATE TO BE MINIMUM 3,192 PSI CONCRETE OR ASTM C-90 HOLLOW BLOCK AT JAMB ANCHORS. 5. STEEL STUD OPENINGS (16 GA. MINIMUM THICKNESS) TO BE MINIMUM Fy = 33 ksi. 6. STRUCTURAL STEEL OPENINGS (1/4" MINIMUM THICKNESS) TO BE MINIMUM Fy = 36 ksi.

PRODUCT DETAILS

OPTION DRAWINGS FINISHES Finish Type Description/Application Color Selection Standard Warranty (Aluminum) 2-coat 70% Kynar 500 /Hylar 5000 AAMA 2605 Dry film thickness 1.2 mil. (AKA: Duranar, Fluoropon, Trinar, Flouropolymer, Polyvinylidene Fluoride, PVDF2) Best. The premier finish for extruded aluminum. Tough, long-lasting coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% Kynar 500 /Hylar 5000 or Baked Enamel. 10 Years (Consult Greenheck for availability of extended warranty) 2-coat 50% Kynar 500 /Hylar 5000 AAMA 2604 Dry film thickness 1.2 mil. (AKA: Acroflur, Acrynar ) Baked Enamel AAMA 2603 Dry film thickness 0.8 mil. (AKA: Acrabond Plus, Duracron ) Better. Tough, long-lasting coating has excellent color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Good. Provides good adhesion and resistance to weathering, corrosion and chemical stain. 2-Coat Mica: Greenheck offers 9 standard 2- coat Mica colors. Other colors are available. Consult Greenheck for possible extra cost when selecting non-standard colors or special finishes. 5 Years 1 Year Integral Color Anodize AA-M10C22A42 (>0.7 mil) Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil) Clear Anodize 204 R-1 AA-M10C22A31 (0.4-0.7 mil) Industrial coatings Mill Two-step anodizing is produced by following the normal anodizing step with a second, colorfast process. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Light, Medium or Dark Bronze; Champagne; Black Clear Clear Greenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector. Consult a Greenheck Product Specialist for complete color and application information. Materials may be supplied in natural aluminum or galvanized steel finish when normal weathering is acceptable and there is no concern for color or color change. 5 years 5 years 1 Year Consult Greenheck Finishes meet or exceed AAMA 2605, AAMA 2604, and AAMA 2603 requirements. Please consult www.greenheck.com for complete information on standard and extended paint warranties. Paint finish warranties are not applicable to steel products. n/a September 2012 Rev. 1 Copyright 2012 Greenheck Fan Corporation Greenheck Fan Corporation reserves the right to make product changes without notice.