TECHNICAL DATA SHEET SYSTEXX Premium

Similar documents
Approx. Weight in g/m²

Data Sheet 1806 Englisch

Plastering. Holiday Inn - Sultanate of Oman

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD

SECTION RESILIENT SHEET FLOORING

Capaver AkkordVlies G130/190VB

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

Technical Data Sheet Sto-Acoustic Spray Plaster

Capaver ElementEffects

MAWI - The Anti-shock-material in panel form

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

Eco Deco Building System

Container Installation Guide

Tufted and Woven Goods Direct Glue-Down

HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD

Technical Data Sheet

1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.

SECTION CERAMIC TILE

Caparol System PRO Data sheet

Installation & Maintenance Guide

TECHNICAL DATA SHEET

INSTRUCTIONAL BOOKLET

Magnetic Dry Erase Chalk Image Projection Paintable Custom

ROCKMAX MAG CEMENT BOARD

SECTION IMPACT RESISTANT WALL PROTECTION

Crystoflex Max comprising of a liquid component of selected polymers and a powder component of selected cements, fillers and aggregates.

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

DULUX INTERIOR LUXURIOUS SILK TECHNICAL DATA SHEET Version SEPTEMBER THIS ISSUE SUPERSEDES ALL PREVIOUS PUBLICATIONS

BOLON BY YOU INSTALLATION INSTRUCTIONS ROLLS

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:

Stop and Read Before Installing Material

Film Installation Tools

ITEM 458 WATERPROOFING FOR STRUCTURES

RADIANT PANEL SYSTEM PLANNING & INSTALLATION. Roth Radiant Heating Systems

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

RAUPEX SPEED SYSTEM Installation Guide

F.S.P.M.A. PAINT SPECIFICATION DIVISION 9 FINISHES SECTION INTERIOR MP-47.2 MOLD AND MILDEW PROOF ACRYLIC PAINT

Construction. 2-part epoxy impregnation resin. 1 Sikadur /6

MDF WALL PANELS INSTALLATION INSTRUCTIONS

1. Division 09 Section "Rough Carpentry."

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Two component solvent-free epoxy system for creation of self-levelling floors. Gloss <4% <70% IR4

Data Sheet 3631 Englisch

Tidy tiles Walls, floors, stairs and tiles on tiles Building materials of brand-name quality for your home Nur im

SHEETROCK PLASTERBOARD FINISHING SYSTEMS GUIDE.

Container Installation Guide

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

Soft Grip. WATERBASED Anti-Slip Coatings

Installation & Maintenance Guide

Application of DI-NOC Films

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

Division 11 - Equipment Section 11401

Commercial Resilient Sheet Flooring

REBOUND ACE AIR CUSHION

SECTION SPRAY APPLIED WALL COVERING ADHESIVE

Application of 3M DI-NOC Films A Guide for Indoor and Outdoor Dry Applications

Drywall and Plastering

For detailed product information, visit our DeckOver, Textured DeckOver or Extra Textured Deckover product pages.

PPC Cement TUTORIAL. how to screed a floor

PRODUCT DATA SHEET Sikafloor -161

IVC US Residential Installation Guide - Sheet Vinyl. Leading the Way

Sikafloor -161 is an economic, two part, solvent free, low viscosity epoxy resin, suitable for use under hot climate condition.

Ready-to-use structural plaster for interior use

ENGINEERED WATERPROOF FLOORING GENERAL INSTALLATION INSTRUCTIONS FOR VÄLINGE 2G LOCKING FLOORING

FlexLok Adhesive Tabs for Carpet Tile

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

1-part polyurethane pourable self levelling floor joint sealant

PITTSBURGH CORNING ASSEMBLY INSTRUCTIONS. KWiK N EZ Rigid Track Silicone System for Thinline Series Glass Block

FLUID APPLIED WATERPROOFING

For sheet metal tiles

HOW TO TILE HOW TO TILE

INSTALLATION INSTRUCTIONS FOR WICANDERS HYDROCORK

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

ITALIAN CREATIVITY IN THE SERVICE OF DESIGN. Ginevra

Offering the best price-performance in the industry. 1 (800) Presto Tape is a proud USA Manufacturer.

HYDRAULIC GATE SEALS. Industrial Rubber Supply (1995) Ltd.

CARPET CARPET

VESDURA VINYL PLANKS 7.5MM WPC CLICK LOCK - AMERICANA COLLECTION

PRODUCT SELECTION GUIDE

SYNTHETIC GRASS INDOOR SURFACE SPECIFICATIONS: K9GRASS LITE

1-part elastic joint sealant and multipurpose adhesive

Water-Activated Tape Product Guide

GLUE-DOWN INSTALLATION VIRTUO 30 / 55

m2 Anti-Slip Tape Daylight Fluorescent R13

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

The CLAYTEC clayboard is a dry lining board for internal use made of reed-reinforced

INSTALLATION GUIDANCE. Easy to Install, Clean and Maintain NO GROUT! Perfect for Showers!

Signature Sports Flooring Installation Instructions. For SignaDeck Premium Rubber Tiles

Section SoundPly LR M25 Acoustic Ceiling Panels

Amtico QuickStix LVF Installation

PVC Project Assembly Guide a FORMUFIT field manual

BTM BT2K 600. Areas of Use

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

TILING SPECIFICATIONS

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

OTTOSEAL S100 OTTOSEAL S105

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE

LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR LOCKING FLOORING

Transcription:

TECHNICAL DATA SHEET SYSTEXX Premium Innovative glass fabrics for walls and ceilings Properties / Typical application The SYSTEXX Premium wall coverings are woven from glass yarns. The water activatable adhesive coating applied to the back gives them outstanding technical and ecological properties. All the SYSTEXX wall coverings have brand certification in accordance with DIN EN 13501-1:2010, and meet Class B-s1, d0. Thanks to its high quality, SYSTEXX Premium satisfies Oeko-Tex Class 1. Due to the variety of designs and the possibility of combinations with highly varied coating systems, SYSTEXX offers a large number of surface finishes. The technical and aesthetic properties make SYSTEXX wallcoverings ideal for the interiors of commercial and private buildings. Individual designs can be created by using suitable creative techniques. FIREPROOF Class B-s1, d0 WALL REINFORCING AND CRACK BRIDGING Crack bridging in accordance with class A5 crosswise (A4 lengthwise): 1.4 3 mm in plaster and drywall. Breaking load reinforcement at least 40% lengthwise (20% cross-wise) RESISTANT TO IMPACT AND PERFORATION At multiple impact to 20kN; maximum force of min. 200N in perforation test ABRASION AND SCOUR PROOF* Minimum 4.000 scrubbing cycles, in the abrasion test RESISTANT TO DISINFECTION AGENTS AND CLEANING** In accordance with the recommendations published by the Robert Koch Institute WATER VAPORPERMEABLE sd-value 0,14 m APPROVED AS SAFE UNDER HARMFUL SUBSTANCE AND FOOD LAWS SUITABLE FOR ALLERGY SUFFERERS NOT HARMFUL TO HEALTH * Depending on coating (at least wet abrasion resistance class 3, DIN EN 13 300). ** Depending on interior wall paints suited for this (see data sheets of paint manufacturers). SYSTEXX PRODUCED 30-YEAR PREMIUM IS ACCORDING TO WARRANTY Last update: 01/02/2017 Page 1 of 7

SYSTEXX PREMIUM EXCLUSIVE Technical Parameters / Roll Style Product SAP designation Weight in g/m² Width in cm Lengths in m Pattern Repeat cm SYSTEXX Premium 004 GG 904 RW AQ 25m 320 100 25 - O free match SYSTEXX Premium 006 GG 906 RW AQ 25m 320 100 25 - O free match SYSTEXX Premium 013 GG 913 RW AQ 25m 320 100 25 - - straight match 20 SYSTEXX Premium 025 GG 925 RW AQ 25m 320 100 25 - O free match SYSTEXX Premium 046 GG 946 RW AQ 25m 225 100 25 - - straight match 19 SYSTEXX Premium 047 GG 947 RW AQ 25m 225 100 25 - - straight match 16 SYSTEXX Premium 049 GG 949 RW AQ 25m 225 100 25 - - straight match 32 SYSTEXX Premium 050 GG 950 RW AQ 25m 225 100 25 - - straight match 32 SYSTEXX Premium 051 GG 951 RW AQ 25m 225 100 25 - - straight match 64 SYSTEXX Premium 052 GG 952 RW AQ 25m 225 100 25 - - straight match 64 SYSTEXX Premium 053 GG 953 RW AQ 25m 225 100 25 - - straight match 32 SYSTEXX Premium 060 GG 960 RW AQ 25m 225 100 25 - O free match SYSTEXX PREMIUM TEHERANI Technical Parameters / Roll Style Product SAP designation Weight in g/m² Width in cm Lengths in m Pattern Repeat cm SYSTEXX Premium 071 GG 971 RW AQ 25m 225 100 25 - - straight match 22 SYSTEXX Premium 072 GG 972 RW AQ 25m 225 100 25 - - straight match 25 SYSTEXX Premium 073 GG 973 RW AQ 25m 225 100 25 - - straight match 100 SYSTEXX Premium 074 GG 974 RW AQ 25m 225 100 25 - - straight match 25 SYSTEXX Premium 075 GG 975 RW AQ 25m 225 100 25 - - straight match 19 SYSTEXX Premium 077 GG 977 RW AQ 25m 225 100 25 - O free match Substrate preparation The substrate must be dry, clean, smooth and stable. Remove old wall coverings and unstable coatings. Smooth any stable substrates that are rough or uneven; fill any holes with filler. Ideally the substrate should be prepared in such a way that any imperfections such as extra graininess or small uneven locations can largely be avoided. marks left by preparation work should be 1mm. To achieve this, treat the surface with a smoothing plaster or smoothing pass over a large area. Porous substrates should first be treated with a suitable primer. Remove any mould or fungus, and treat as required by relevant guidelines (Substrate preparation is described in more detail in the Substrate / Preparation table). Last update: 01/02/2017 Page 2 of 7

Application Important for all products Do not apply when the temperature of the room or wall is less than + 8 C. Only use products with the same serial number on adjacent surfaces (printed on the outside of the box). Sheet length = all / ceiling measurement plus 5 10 cm. Cut off the excess cleanly. 1. Using the Aqua Quick pasting machine Pull the roll through the Aqua Quick pasting machine and fold loosely. Allow 1 minute for the integrated adhesive to activate, or 2 to 3 minutes when applying to ceilings. For more information, please refer to the Aqua Quick manual. Allow 7 12 hours drying time at normal room temperature (18 C). The fabric remains workable for up to 30 minutes after activating the adhesive. Working life may vary significantly when applying under extreme climatic conditions (high air humidity, high temperatures). The sheet of fabric can be repositioned up to 20 minutes after applying. Please note that this timeframe depends largely on the substrate and the ambient temperature. Do not leave the immersed in the water bath for more than 5 minutes as this may cause the adhesive to swell and liquefy. If the fabric is left in the water bath for a longer period, we cannot guarantee that the right amount of adhesive with the correct consistency will remain on the fabric. Tip: To avoid waste when a break between cutting one length and the next is necessary/desirable: draw a length 50 cm shorter than required through the Aqua Quick machine, then cut the drop to the correct length along the back edge of the bath. (Example: for a room height of 2.50 m: measure a 2 m drop, then cut on the back edge of the bath to give a total length of 2.50 m). 2. Avoid differences in texture Never paste the product upside down or inside out. The marking on the back provides orientation. When glued, the distance between the marking on the back is m from one sheet to the next. 3. Paste with butt-join The sheets must have very good contact near the seams. Any adhesive left on the front of the fabric should be removed immediately with a damp clean cloth. 4. Press on and cut off Apply enough pressure with a wallpapering squeegee over the whole area to remove bubbles. Press the excess carefully into the corners and trim it off along the edge of the wallpapering squeegee or cutting ruler using a sharp-bladed cutter. Applying to outer corners: use a fine grade of wet abrasive paper ( P 240) to lightly sand off the product around the edges (without sanding through), press around the edges and press out the bubbles. Last update: 01/02/2017 Page 3 of 7

5. Coating We recommend using high-quality dispersion paint. Apply two coats, wait until the first coat has completely dried before applying the second coat. Any level of gloss can be used. 1st coat: 2nd coat: apply the paint evenly after the product has fully dried. Follow the paint manufacturer s application instructions. only do this after the 1st coat of paint has fully dried. Paint consumption: 300 400 g/m 2 for 2 coats The quantity required depends on the fabric structure and on the substrate. You will need to determine accurate values to allocate applications to the building. Similarly, please also see the technical data sheets for those products that will also be used. Coating according to degree of gloss Desired topcoat Required basecoat Matt ------ Semi-gloss - Eggshell - Satin Gloss - High gloss Semi-gloss - Eggshell - Satin Gloss - Satin - High gloss Last update: 01/02/2017 Page 4 of 7

Substrate Exposed concrete Porous concrete, Filigran concrete Sandy plaster Course textured plaster Absorbent plaster (e. g. stucco) Normal plaster Peelable / Stripable wallpaper Scrap wallpaper (e.g. woodchip) Peeling / Flaking paint coating Distemper coatings (e.g. cellulose) Glossy paint coatings Glass fabric Preparation 1. De-burr roughly 1. Clean (abrade and smooth down) 1. Sand down (remove loose sand corn) 2. Stabilize substrate with a suitable primer 3. Fill holes and cracks, smooth and level substrate with a suitable filling 1. De-burr roughly 1. Apply a suitable primer 1. Fill holes and cracks, smooth and level substrate with a suitable filling 2. Sand and prime 1. Remove wallpaper entirely 1. Remove all loose flakes 2. Sand and prime the area 3. Fill holes and cracks, smooth and level substrate with a suitable filling 1. Remove completely by scraping/washing off 2. Prime with suitable keying primer 3. Fill holes and cracks, smooth and level substrate with a suitable filling 1. Sand until there is a matt finish 2. If necessary, apply a keying primer 1. Smoothen and level out fabric structure with a suitable filling (prevents the formation of stripes in the texture) 2. Sand and prime Last update: 01/02/2017 Page 5 of 7

Plasterboard panels OSB panels, wood, Hardboard Ceramic tiles Rusty steel surfaces Bleeding surfaces (e.g. waterstains) Nicotine and soot deposits 1. Fill joints and screw holes in accordance with current plasterboard specifications 2. Sand and prime 1. Insulate / seal surface with suitable primer 2. Fill joints and screw holes with suitable filling 1. Clean and degrease the tiles 2. Apply bonding agent (undercoat/primer for ceramic and glass) 3. Fill and level whole surface with a suitable filling 1. Remove rust as per DIN 55928 PST 2-3 or ST 2-3 2. Apply a suitable anti-corrosive primer 1. Insulate bleeding areas with a suitable primer 1. Treat with an insulating protective layer Last update: 01/02/2017 Page 6 of 7

Guarantee SYSTEXX Premium and SYSTEXX Active Reno glass fabrics have been tested according to the TÜV guidelines and comply with the above mentioned properties. SYSTEXX Premium and SYSTEXX Active Reno wall coverings are covered by a lifetime warranty of 30 years. You can learn more about this warranty at www.systexx.com. Important In spite of strict quality controls, the nature of production means that small faults can occur. These are marked at the edge of the, and compensated for by an additional 0.5 meter length. Complaints made after more than 10 sheets have been laid cannot be accepted. Storage Store the rolls in a dry, clean place. General information 1.) Certain sensitive individuals may find that handling glass fiber irritates their skin. SYSTEXX is tested to Öko-Tex standards to ensure that it is free from allergenic and harmful substances. 2.) The glass staple fiber yarns / Sliver is manufactured in such a way that irregularities are clearly visible in the surface pattern of fabrics made from it. This visual effect is deliberate and does not constitute grounds for complaint. 3.) This information sheet does not claim to address every problem that may occur in practice. Therefore no obligation or liability may be derived from it. Users are obliged to use their professional judgment to assess the application based on the product's suitability and the substrate. Please comply with the relevant national building regulations. In case of doubt, please contact the technical advisory service at Vitrulan Textile Glass GmbH. Last update: 01/02/2017 Page 7 of 7