Safety Signal Models SS0550 thru SS0554

Similar documents
Aero Tec Models 700 & 750 (115 vac)

Field Economy Unit Instruction Manual

Wash Down Duty Non-Contact Sensor

Lithonia Lighting Terms and Conditions of Sale

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

ON-FLOOR WIREWAY INSTALLATION GUIDE

FTW 175 Wireless Monitoring System Reference Manual Part Number

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Thermoelectric Cooler


VI PARTS LIST. , ELECTRIC FRYER PARTS LIST ITEM DESCRIPTION MODELS PART # 10x x24

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

TAYLOR FORGE STAINLESS

TERMS AND CONDITIONS OF SALE

Installation and Operation Manual

RHE3 Dock Leveler Installation Manual

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

OPERATION AND INSTALLATION MANUAL

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS

Drag Chain Conveyor Installation and Operation Manual

USER'S GUIDE TO OPERATION

ViZion Wireless Monitoring System Instructions

Global Water Instrumentation, Inc.

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

Model # 922-S4. 12/18/2013 Page 1 of 8

Model # 338S-OP. 9/30/2011 Page 1 of 13

Protective Capony RTC-16

Wireless Freezer Manual Installation Guide

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

INSTALLATION PROCEDURE

TERMS AND CONDITIONS: (Stated in U.S. Dollars):

CDM Network Programmer for CCT100x

Model # 358-R48. 7/7/2011 Page 1 of 11

Wine Storage Models 427G and 427RG Design Guide

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

Precision Automatic Vacuum Control (PAVC+)

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

10810 W. LITTLE YORK RD. #130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Sby SR Instruments, Inc.

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

FPF-P 2045 FLAT TOP CHAIN CONVEYOR

OPO-SHORT Installation Instructions Manual Version

Model # 158-P4. 12/12/2013 Page 1 of 11

Model # 238HS-P8. 4/27/2011 Page 1 of 11

INSTALLATION MANUAL Accordion Gangplank Model No. FBL-1000

WLC60 Heavy Duty LED Light

Model # 358H-PR. 4/8/2011 Page 1 of 12

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

PRODUCT MANUAL. Descender Ceiling Lift

FLEX SHOWER DOOR INSTALLATION INSTRUCTIONS. For more information on DreamLine TM Shower Doors please visit

CMT MANUAL 1.2 TERMS AND CONDITIONS

PVC WATER FITTINGS List Price Sheet

Model # BARK-358-RDP

JOINT RESTRAINT PRODUCTS & ACCESSORIES

INSTALLATION PROCEDURE

2.7 IN-CARPET WIREWAY

FLEX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Efficient-Tec International LLC

RollE & RollE4-32 (Prior to May 2013)

Carbon Forged Steel Fittings

DRYWALL DOLLY 900 LB. CAPACITY

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

SELF-REGULATING ROOF HEAT CABLE. Installation Guide WS-SRIM V2.0

Daniel TM Ultrasonic Flow Meters

Owner s Manual & Safety Instructions

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

QUATRA SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Bed Docker. Installation Manual. Model BD 600/601

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

Pneumatic PalletPal Level Loader

PalletPal Pallet Inverter / Rotator

Miniature Proportional Valves Precision Fluidics

ALLIED ELECTRONICS, INC STATION SITE CONTROLLER (SSC) Installation and Start Up Guide. ARCO / ANDI to Wayne PIB

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

PEN SEAL. Pipe Penetration Seals

Sageon Site Monitor (SSM) Application Note

Bottom Hinged Flood Barrier Operation & Maintenance Manual

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

BIN LINER INSTALLATION MANUAL IMPORTANT!

LOAD RAMP 1000 LB. CAPACITY

Installation. Basic Rack Power Distribution Units AP9560 AP9561

Lighting Services Inc. QuickShipExpress 5-10 Day Service

VISE MOUNTED. Model 97359

Contents CONTACT INFORMATION... 2

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

PROPOSAL FOR MODEL: HP 2100X

Please read and follow the instructions below carefully to ensure proper setup and avoid problems.

WP200e Wallbox to CD Changer Adapter

MODEL BRT GAS-FIRED TUBULAR UNIT HEATERS

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09008

NVD-40 NEAR VERTICAL DRUM LIFTER INSTRUCTION MANUAL

Global Water Instrumentation, Inc.

SECTION COOLING TOWER

FOUR FOLD DOORS-WITH SINGLE OVERHEAD MTD OPERATOR

AQUA UNO T UB DOOR AND T UB DOOR GLASS PANEL INSTALLATION INSTRUCTIONS

Transcription:

Safety Signal Installation Guide Safety Signal Models SS0550 thru SS055 A Product of 0 Gateway Park Drive North Syracuse, NY Phone: 5-6-78 Toll Free: 866-5-768 Fax: 5-6-8559 Email: sales@dlmanufacturing.com www.dlmanufacturing.com 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page INTRODUCTION This manual is used for all Safety Signal model types. The control board is programmed for each model s function. The description explains the differenced between model types. Model # Part # Description 550 SS0550 55 SS055 55 SS055 55-0 SS055-0 55 SS055 55 SS055 55-0 SS055-0 Standard Safety Signal No options: No outlets or interlocks Powers & controls one outlet for dock light Dock light turns off when door is closed Powers & controls two outlets Dock light & fan turn off when door is closed No Inside Red & Green Light Powers & controls two outlets Dock light & fan turn off when door is closed Powers & controls two outlets & interlocks Electric/Hydraulic leveler Dock light and fan turn off when door is closed Leveler will not run when door is closed Powers & controls two outlets & interlocks Pneumatic leveler Dock light and fan turn off when door is closed Leveler will not run when door is closed Fan turns off when leveler runs No Inside Red & Green Light Powers & controls two outlets & interlocks Pneumatic leveler Dock light and fan turn off when door is closed Leveler will not run when door is closed Fan turns off when leveler runs ELECTRICAL RATINGS: INPUT VOLTAGE INPUT FREQUENCY MAXIMUM INPUT CURRENT 0 VAC 60 HZ A INPUT CURRENT WITH NO OUTLET(S) OR LEVELER LOAD <.5 A (MODEL 550) MAXIMUM OUTLET(S) CURRENT A MAXIMUM LEVELER LOAD CURRENT (J7 OR J8) A OUTSIDE LIGHT BOX VOLTAGE VDC MAXIMUM OUTSIDE LIGHT BOX LOAD CURRENT.5 A ( V POWER SUPPLY CURRENT LIMIT) SENSOR VOLTAGE (J, J & J) VDC MAXIMUM SENSOR CURRENT (J, J & J). A (J, J & J PROTECTED BY PTC THERMISTOR) 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page Safety Signal ---Sequence of Operations--- Testing Door Opens Outside light turns red Inside light turns green Interlock items now function Dock light Fan Leveler & OPT Contacts close Door Closes Outside light turns green Inside light turns red Interlock items turn off Dock light Fan Leveler & OPT Contacts open Please Note: When dock door is closed, the light will switch to red inside and green outside after a 0 second delay. 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page WARNING!!!! Do not use in hazardous or corrosive environments! REQUIRED TOOLS Drill bits, masonry bit for tap-con / wood bits /6 for pilot hole in dock seal Tape measure Wire strippers Hammer Felt tip marker Hammer Drill Drill screw gun Precision flat blade screwdriver /8 wide Wire labels INDEX Description Page COVER - INTRODUCTION / ELECTRICAL RATINGS SEQUENCE OF OPERATIONS GENERAL INFO / INDEX / REQUIRED TOOLS INSTALLER SUPPLIED HARDWARE & FASTENERS INSIDE LIGHT BOX MOUNTING 5 INSIDE LIGHT BOX MOUNTING CONTINUED 6 PHOTO EYE INSTALL TYPICAL & MxV DOOR 7 PHOTO EYE INSTALL ROLLING STEEL DOOR 8 EXTERNAL BOX INSTALLATION 9 CONTROL BOARD WIRING OVERVIEW / INDEX 0 WIRING DIAGRAM J & J WIRING DIAGRAM J6, J7 & J8 INSIDE TO OUTSIDE BOX WIRING DIAGRAM J5 DOCK SEAL BRACKET (OPTIONAL) YEARLY MAINTENANCE. Inspect inside connections for any damage. Inspect mounting bolts for tightness. Clean unit with compressed air. Clean Photo Sensor Lenses BOLLARD MOUNTING BRACKET (OPTIONAL) 5 MODEL 550 SYSTEM WIRING DIAGRAM 6 MODEL 55 SYSTEM WIRING DIAGRAM 7 MODEL 55 SYSTEM WIRING DIAGRAM 8 MODEL 55 SYSTEM WIRING DIAGRAM 9 MODEL 55 SYSTEM WIRING DIAGRAM 0 DL MANUFACTURING TERMS/CONDITIONS/WARRANTY 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page Installer-supplied hardware & fasteners Mounting Surface Inside Light Box Outside Light Box Cement Block () ¼ x ¼ Tapcon () #0 x Tapcon Tip up concrete panel () ¼ x ¼ Tapcon () #0 x Tapcon Sheet Metal Steel Bollard Dock Seal Sheet metal walls are not thick enough to hold inside box () ¼ x ¾ self-drilling screws Use DL Manufacturing supplied fasteners Sheet metal walls are not thick enough to hold outside box () ¼ x ¾ self-drilling screws Use -/ x ¼ lag screws to attach dock seal bracket to dock seal. Also needed: Wiring the inside and outside box together conductor 8 gauge wire ½ flexible conduit with connector for 7/8 knockout Field Notes: FOR SERVICE ASSISTANCE CALL DL MANUFACTURING TOLL FREE 866-5-768 Safety Signal Model #: Safety Signal Serial #: (LOCATED LOWER PORTION OF CONTROL BOARD) Door Location: Customer: 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page 5 INSIDE LIGHT BOX MOUNTING 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page 6 SEE PAGE FOR FASTENER USAGE INSIDE LIGHT BOX MOUNTING CON T. 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page 7 PHOTO EYE MOUNTING KIT (FOR TYPICAL LOCATIONS & MxV DOOR) SEE PAGE 8 FOR MOUNTING BRACKET LOCATION ON A ROLLING STEEL DOOR STEP MEASURE 8 ABOVE THE DOOR (START AT THE TOP OF DOOR JAMB) TO INSTALL PHOTO SENSOR STEP DRILL HOLES IN ROLLER TRACK. USE 7/6 DRILL BIT REFER TO PAGE FOR WIRING INSTRUCTIONS NOTE: PHOTO SENSOR HAS A RANGE OF / TO -/. TO IS RECOMMENDED. ITEM # QTY. PART# CP506 CP68 DESCRIPTION MOUNTING BRACKET KIT PHOTO SENSOR NUT KIT DETAIL A SCALE : 0 PHOTO EYE INSTALL TYPICAL & MxV DOORS 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page 8 PHOTO EYE MOUNTING KIT (FOR ROLLING STEEL DOOR) SEE PAGE 7 FOR MOUNTING BRACKET LOCATION ON A SECTIONAL DOOR STEP TO LOCATE THE MOUNTING BRACKET POSITION, OPEN THE DOOR ALL THE WAY. STEP POSITION THE TOP OF THE BRACKET SO THAT IT LINES UP JUST BELOW THE BOTTOM SECTION OF THE DOOR AND MARK HOLES. STEP DRILL HOLES IN ROLLER TRACK. USE 7/6 DRILL BIT. STEP LOCATE THE PHOTO SENSOR OPERATING ADJUSTMENT (SEE FIGURE BELOW). SET THE PHOTO SENSOR FOR LIGHT OPERATE. STEP 5 ATTACH THE PHOTO SENSOR TO THE MOUNTING BRACKET USING THE NUTS AND WASHERS SUPPLIED WITH SENSOR. BOTTOM OF DOOR WHEN FULLY OPEN STEP 6 ATTACH THE MOUNTING BRACKET TO THE TRACK RAIL USING HARDWARE SUPPLIED WITH MOUNTING KIT. REFER TO PAGE FOR WIRING INSTRUCTIONS PHOTO EYE INSTALL ROLLING STEEL DOORS 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page 9 SAFETY SIGNAL TM INSTALLATION WALL MOUNTED STYLE EXTERIOR (BLACK BOX) STEP INSTALL EXTERNAL SAFETY SIGNAL MEASURING 90 [,86mm] FROM THE GROUND TO THE CENTER OF THE BLACK BOX AND FROM THE DOCK SEAL OR SHELTER, OR 8 FROM INSIDE WALL EDGE. SEE PAGE FOR MOUNTING HARDWARE. SEE PAGE WHEN USING DOCK SEAL BRACKET. DOCK SEAL STEP REFER TO PAGE FOR WIRING INSTRUCTIONS. USE KNOCKOUT LOCATED ON THE BACK OR BOTTOM. NOTE: LEVELER 90" [.86 mm]. RED LIGHT MUST BE ON TOP. SEE PAGE FOR ALTERNATE MOUNTING WHEN BOX CAN T BE MOUNTED TO WALL. MOUNT BOX PARALLEL TO WALL. CONSULT DL MANUFACTURING IF DRIVEWAY IS SLOPED.8 [.90] DETAIL A SCALE : GROUND LEVEL 6.90 [75.0].50 [7.50] EXTERNAL BOX INSTALLATION 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page 0 REMOVE POWER BEFORE SERVICING. MUST BE INSTALLED BY QUALIFIED ELECTRICIAN MODEL 55 LEVELER BUTTON SEE PAGE FOR CONNECTIONS DO NOT APPLY VOLTAGE TO J6 TERMINALS, FOR SWITCH ONLY J6-, 8. VDC, ma MAX J6-, COMMON GND RED LED STRIP CP8006 NO RED OR GREEN LED STRIPS INSTALLED IN MODELS 55-0 & 55-0 GRN LED STRIP CP8005 J5 NOT USED OPTIONAL TERMINAL BLOCK JUMPERS FOR OPT & OPT SEE PAGE 6 FOR JUMPER SETTINGS J- OR J-, COMMON GND J- OR J-, INPUT SIGNAL J- OR J-, + VDC,.A MAX OPTIONAL SENSOR SEE INSTRUCTIONS THAT OPTIONAL SENSOR COMES WITH J-, COMMON GND J-, SENSOR SIGNAL J-, + VDC,.A MAX DockLogic OPTION RS85 CONNECTION 5 VDC, 60 ma MAX 900 bps OUTSIDE LIGHT BOX SEE PAGE FOR CONNECTIONS J0-, COMMON GND J0-, CHANNEL A J0-, CHANNEL B J5-, + VDC,.5 A MAX J5-, RED LIGHT J5-, NO CONNECTION J5-, GREEN LIGHT AMP SLO-BLO 50V FUSE UNDER FUSE COVER J6 (CHOCK) NOT USED ON SAFETY SIGNAL PHOTO SENSOR SEE PAGE FOR CONNECTIONS J-, COMMON GND J-, SENSOR SIGNAL J-, + VDC,.A MAX REPLACE WITH ONLY SAME TYPE AND RATING FOR BEST RESULTS WHEN REPLACING FUSE, PLACE FUSE IN COVER, THEN PLACE COVER OVER CLIPS AND THEN SNAP FUSE INTO CLIPS J7 NOT USED Switching Relays for J7, J8, Versa Light Outlet and Fan Outlet are Rated 0-0 VAC, A.75 Power Factor. ASSEMBLY NUMBER & REV. LABEL AMP BREAKER FOR SWITCHED VERSA LIGHT AND FAN OUTLETS ONLY 0 VAC INPUT 0 VAC, A MAX 60 HZ SEE PAGE FOR CONNECTIONS J-, 0 VAC LINE J-, 0 VAC NEUTRAL J-, GROUND MODEL 55 & 55 GRND MODEL 65 & 65 LEVELER INTERLOCK 0 VAC, A MAX 60 HZ J7- & CONNECTED TO K ISOLATED RELAY CONTACTS REFER TO PAGE MODEL 55 & 55 OPTIONAL ALTERNATE CONTACTS 0 VAC, A MAX 60 HZ J8- & CONNECTED TO K ISOLATED RELAY CONTACTS REFER TO PAGE WIRING OVERVIEW / INDEX 7/9/0 SS9556 REV A

DOOR Safety Signal Installation Guide Page SAFETY SIGNAL TM FIELD WIRING DIAGRAM INCOMING POWER INTERNAL (YELLOW BOX) J BLACK (0 VAC, A MAX, 60Hz) WHITE (0 VAC NEUTRAL) GREEN (GND) - ALL MODELS EXCEPT 55 & 55 GND WIRE FROM CHASSIS GND IS PRE-INSTALLED ON MODELS 55 & 55 GREEN (GND) - MODELS 55 & 55 ONLY ON MODELS 55 & 55 USE CHASSIS GND CONNECTION (NOT USED ON OTHER MODELS) MUST BE INSTALLED BY QUALIFIED ELECTRICIAN J DOOR PHOTO SENSOR PHOTO SENSOR IS VDC. DO NOT RUN IN SAME CONDUIT WITH 0 AND HIGHER VOLTAGE. TRANSIENTS CAN DAMAGE CONTROL BOARD BLUE -COM BLACK BROWN + VDC,.A MAX SENSING REVERSAL ROTATE ADJUSTMENT / TURN TO CHANGE OPERATION FROM (N/O TO N/C OR N/C TO N/O) NORMALLY SET FOR DARK OPERATE OR N/C WHEN LOCATED ABOVE PANELED DOOR OPENING LED Dark Op Light Op WIRING DIAGRAM J & J 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page SAFETY SIGNAL TM FIELD WIRING DIAGRAM MODEL 55 LEVELER CONTROL SIGNAL FX LEVELER BUTTON J6-, 8. VDC, ma MAX J6-, COMMON GND DO NOT APPLY ANY EXTERNAL VOLTAGE TO J6 TERMINALS NOTE: WHEN LEVELER SWITCH IS ACTIVATED, THE CONTROL SIGNAL WILL LET THE MICRO PROCESSOR KNOW TO SHUT THE FAN OFF. IT WILL THEN TURN ON THE LEVELER (J7) AND OPT (J8) AFTER A SECOND DELAY. FAN WILL TURN ON WHEN LEVELER STOPS. MODEL 55 LEVELER INTERLOCK / OPT J8 (OPT) CONTACTS CLOSE WHEN J7 (LEVELER) CLOSE. CONTACTS CONNECTED TO J7 & J8 ARE RATED 0 VAC A,.75 POWER FACTOR. CONTACTS CONNECTED TO J7 & J8 ARE DRY CONTACTS (ISOLATED FROM INTERNAL CONTROL BOARD CIRCUITRY). 0-0 VAC LINE, A MAX, 50 / 60 HZ TO LEVELER MOTOR MODEL 55 LEVELER INTERLOCK / OPT J8 (OPT) CONTACTS CLOSE WHEN J7 (LEVELER) CLOSE. CONTACTS CONNECTED TO J7 & J8 ARE RATED 0 VAC A,.75 POWER FACTOR. () CONNECT LEVELER INTERLOCK FROM LEVELER CONTROL BOX TO J7- AND J7-. 0 VAC, A MAX, 50 / 60 HZ CONTACTS CONNECTED TO J7 & J8 ARE DRY CONTACTS (ISOLATED FROM INTERNAL CONTROL BOARD CIRCUITRY). () SEE MANUFACTURERS DOCK LEVELER INSTRUCTIONS FOR INTERLOCK CONNECTIONS WIRING DIAGRAM J6, J7 & J8 7/9/0 SS9556 REV A

OUTSIDE LIGHTS Safety Signal Installation Guide Page SAFETY SIGNAL TM FIELD WIRING DIAGRAM OUTSIDE LIGHTS EXTERNAL (BLACK) BOX FROM CONTROL BOARD INTERNAL (YELLOW) BOX + VDC,.5A MAX TO RED LIGHT NOT USED TO GREEN LIGHT J5 TO OUTSIDE R&G LED EXTERNAL (BLACK) BOX J + VDC,.5A MAX FOR RED LIGHT FOR GREEN LIGHT WIRING DIAGRAM INSIDE TO OUTSIDE BOX 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page OPTIONAL DOCK SEAL BRACKET SIGN GOES ABOVE LIGHT BOX SIGN & LIGHT BOX MOUNT ON BRACKET (SS509). (6) #0 SELF TAPPING SCREWS (INCLUDED) INSTALL DOCK SEAL BRACKET AT MOUNTING HEIGHT OF 0. IF BRACKET IS NOT USED, REFER TO PAGE 9 FOR CORRECT MOUNTING HEIGHT 0" [590.8mm] (CM) /" LONG TECH SCREWS ( PLACES) (NOT INCLUDED) WALL DOCK SEAL FRAME BUMPER DOCK SEAL FRAME GROUND LEVEL DETAIL A ALTERNATE OUTSIDE LIGHT BOX MOUNTING DOCK SEAL FRAME SEE DETAIL A WALL BUMPER DOCK SEAL SAFETY SIGNAL TM DOCK SEAL BRACKET PART # SS509 Surface must be Parallel to wall. OPTIONAL DOCK SEAL BRACKET 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page 5 OPTIONAL BOLLARD BRACKET 7/9/0 SS9556 REV A

5 5 Safety Signal Installation Guide Page 6 PHOTOSEN E R BRN BLU BLK J7 J GROUND NEUTRAL LINE P J7 J8 J P FAN LEVELER OPT AC INPUT VERSALITE K K K BRKR K A IR OPTION NOT USED J8 F A OUTSIDE LIGHTS J5 POWER SUPPLY J6 CHOCK Inside Red LEDs Inside Green LEDs LEV CNTRL J6 RS85 J0 DOOR J OPT J OPT CONTROL BOARD E7 EMULATOR J5 J9 & J0 RS-/85 COM PORT J9 RS OUTSIDE LIGHT BOX RED J J J J + RED GRN GRN PC ASM SS80 J0- RS85 CHANNEL B J0- RS85 CHANNEL A J0- SIGNAL GROUND J9- RS RXD (DB9-, RED) J9- RS TXD (DB9-, BRN) J9- SIGNAL GROUND (DB9-5, YEL) MODEL 550 WIRING DIAGRAM 7/9/0 SS9556 REV A

5 5 Safety Signal Installation Guide Page 7 PHOTOSEN E R BRN BLU BLK J7 J P J7 FAN K LEVELER K IR OPTION NOT USED DOOR J OPT J OPT GROUND NEUTRAL LINE LIGHT J8 J P OPT K AC INPUT BRKR A VERSALITE K F J5 J8 A OUTSIDE LIGHTS POWER SUPPLY J6 CHOCK Inside Red LEDs Inside Green LEDs LEV CNTRL J6 RS85 J0 CONTROL BOARD E7 EMULATOR J5 J9 & J0 RS-/85 COM PORT J9 RS RED J J J J + RED GRN GRN PC ASM SS80 J0- RS85 CHANNEL B J0- RS85 CHANNEL A J0- SIGNAL GROUND J9- RS RXD (DB9-, RED) J9- RS TXD (DB9-, BRN) J9- SIGNAL GROUND (DB9-5, YEL) MODEL 55 WIRING DIAGRAM 7/9/0 SS9556 REV A

5 5 Safety Signal Installation Guide Page 8 PHOTOSEN E R BRN BLU BLK GROUND NEUTRAL LINE FAN LIGHT P J7 J8 J P FAN LEVELER OPT AC INPUT VERSALITE K K K BRKR K A J7 IR OPTION NOT USED J8 F A OUTSIDE LIGHTS J5 POWER SUPPLY J6 CHOCK Inside Red LEDs Inside Green LEDs LEV CNTRL J6 RS85 J0 J DOOR J OPT J6 OPT CONTROL BOARD E7 EMULATOR J5 J9 & J0 RS-/85 COM PORT J9 RS RED J J J J + RED GRN GRN PC ASM SS80 J0- RS85 CHANNEL B J0- RS85 CHANNEL A J0- SIGNAL GROUND J9- RS RXD (DB9-, RED) J9- RS TXD (DB9-, BRN) J9- SIGNAL GROUND (DB9-5, YEL) MODEL 55 WIRING DIAGRAM 7/9/0 SS9556 REV A

5 5 T T T GRND Safety Signal Installation Guide Page 9 80 PH LEV MOTOR CIR BRKR 80/0 PH MOT CONTACTOR TYPICAL HYDRAULIC LEVELER WIRING DIAGRAM PHOTOSEN BRN E R BLU O/L BLK MOT CONTACTOR COIL LEVELER BUTTON FAN P J7 FAN K LEVELER K J7 IR OPTION NOT USED J DOOR J OPT J OPT GROUND NEUTRAL LINE LIGHT J8 J P OPT K AC INPUT BRKR A VERSALITE K F J5 J8 A OUTSIDE LIGHTS POWER SUPPLY J6 CHOCK Inside Red LEDs Inside Green LEDs J6 LEV CNTRL RS85 J0 CONTROL BOARD E7 EMULATOR J5 J9 & J0 RS-/85 COM PORT J9 RS RED J J J J + RED GRN GRN PC ASM SS80 J0- RS85 CHANNEL B J0- RS85 CHANNEL A J0- SIGNAL GROUND J9- RS RXD (DB9-, RED) J9- RS TXD (DB9-, BRN) J9- SIGNAL GROUND (DB9-5, YEL) MODEL 55 WIRING DIAGRAM 7/9/0 SS9556 REV A

5 5 Safety Signal Installation Guide Page 0 PHOTOSEN E R BRN BLU TYPICAL PNEUMATIC LEVELER WIRING DIAGRAM BLK M LEVELER MOTOR FAN P J7 FAN K LEVELER K J7 IR OPTION NOT USED J DOOR J OPT J OPT INCOMING 0V POWER GROUND NEUTRAL LINE GRND LIGHT J8 J P OPT K AC INPUT BRKR A VERSALITE K F J5 J8 A OUTSIDE LIGHTS POWER SUPPLY J6 CHOCK Inside Red LEDs LEV CNTRL J6 Inside Green LEDs RS85 J0 CONTROL BOARD E7 EMULATOR J5 J9 & J0 RS-/85 COM PORT J9 RS RED J J J J + RED GRN GRN PC ASM SS80 LEVELER BUTTON COM PORT CONNECTIONS: J0- RS85 CHANNEL B J0- RS85 CHANNEL A J0- SIGNAL GROUND J9- RS RXD (DB9-, RED) J9- RS TXD (DB9-, BRN) J9- SIGNAL GROUND (DB9-5, YEL) MODEL 55 WIRING DIAGRAM 7/9/0 SS9556 REV A

Safety Signal Installation Guide Page Shipping Times DL Manufacturing Terms / Conditions/ Warranty ~ Orders for stock items received by :00pm EST will be processed for shipment the next day. Orders requesting nd Day Air or Overnight Air received by :00pm will be processed for same day shipment. Shipments / Freight Returns ~ All DL Manufacturing orders will ship directly from our facility in North Syracuse, NY. ~ All parts will be shipped via UPS Ground unless you authorize a different service. UPS shipments are prepaid and the charges are added to your invoices. ~ For orders shipping by common carrier, the freight will be FOB, North Syracuse, NY. When best way is the preferred shipping method on your order, DL Manufacturing will choose the carrier, unless otherwise stated, for the orders shipping from this facility. No adjustments will be made after the order has shipped. ~ DL Manufacturing will issue a Returned Material Authorization (RMA) number for any product, parts and accessories. Products should not be returned without an RMA number. ~ Replacement parts will be invoiced at the time of shipping. Invoices will be credited upon receipt and inspection of Returned Material Authorization (RMA). ~ Freight for returns is paid for by the shipper unless otherwise specified by DL Manufacturing. ~ A restocking fee of 5% of net price or a minimum $0.00 is charged for returns. ~ All replacement parts are warranted for a period of 90 days from shipment. Cancellation Fees ~ Cancellation charges may be incurred on orders cancelled with DL Manufacturing. Please contact DL Manufacturing to discuss each situation. Warranty Policy ~ All Products (excluding bulbs) manufactured by DL Manufacturing are warranted to be free from defects for a period of months from the date of shipment, excluding doors, which have a warranty period of months from date of installation or 8 months from shipment, whenever occurs first. This warranty does not cover unreasonable/improper use or use beyond rated conditions, improper storage, negligence or accident; damage because of incorporated use of equipment with Goods, after Customer has or reasonably should have, knowledge of any defect; or improperly installed by any other Person that is unauthorized by DL Manufacturing. This warranty is subject to customer covenants to inform all subsequent buyers of the Goods of the limitation on and exclusive of warranties provided for herein. Customer hereby indemnifies and agrees to hold DL Manufacturing harmless from and against all losses, costs and expenses, including reasonable attorney s fees incurred by DL Manufacturing as a result of any third party claim relating to the purchase, sale or use of, or otherwise relating to, the Goods covered by this Agreement. In no event shall DL Manufacturing be required to repair, replace or reimburse Customer for more than the part or material that is found to be defective and DL Manufacturing s liability shall in such event be no greater than the invoiced price of the item and shall not include labor, shipping or other costs incurred in connection with the reshipment of defective Goods to DL Manufacturing or the reinstallation of such Goods after any repair or replacement. The remedy set forth in this paragraph is expressly agreed to be the sole and exclusive remedy for any breach of warranty. This warranty is exclusive and in lieu of all other warranties expressed or implied, including but not limited to any warranty of merchantability or of fitness for a particular purpose. Limitation of Liability - In no event as a result of breach of contract, warranty or negligence shall DL Manufacturing be liable for special, or consequential damages including but not limited to loss of profits or revenues, loss of any equipment, cost of capital, cost of substitute equipment, facilities or services, downtime costs or claims of purchasers of the Customer for such damages. Additionally, DL Manufacturing will not be liable for any delay in the performance of contracts and orders, or in the shipment and delivery of goods, or for any damage suffered by the Customer by reason of delay, when such delay is, directly or indirectly, caused by force majeure, including war, Government interference, strikes, embargoes, shortage of labor, fuel, fires, floods, or any other cause or cause whether or not similar in nature to any of those herein before specified beyond DL Manufacturing s control. 7/9/0 SS9556 REV A