Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

Similar documents
Optical Emission Spectrometers

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Analysis of Cast Iron Using Shimadzu PDA-7000

Combustion Master CS Carbon and Sulphur Analyser

Surface chemical analysis Analysis of zinc- and/or aluminium-based metallic coatings by glow-discharge optical-emission spectrometry

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

Korkealämpötilaprosessit

SPECTRO XRF Report. SPECTRO xsortxhh03. Analysis of Solid Metal Samples. Summary

Using Guard Bands to Accommodate Uncertainty in the Spark AES Analysis of Aluminum or Aluminum Alloys When Determining Compliance with Specified

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

ANALYTICAL PERFORMANCE OF A HANDHELD EDXRF SPECTROMETER WITH MINIATURE X-RAY TUBE EXCITATION

GB Translated English of Chinese Standard: GB

Carbon / Sulfur Analyzers

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

Technical specifications

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

INDEX DETAILED. STP292-EB/Jan. 1962

Low Energy Consumption, High-Speed Productivity LCG 3015 AJ. Fiber Laser Cutting System

SPECTRO ARCOS. ICP-OES analyzers. When results matter

SPECTRO ARCOS ICP-OES ANALYZERS. When results matter

DRPK-005

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Quantification of Phosphorus Content in Electroless Nickel Immersion Gold Deposits

National Food Safety Standard

ProFoss for in-line process analysis of WPC MPC

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of

Saving Energy For The World High Quality LED Lights Energy Saving Revolution Long Lifespan Eco-friendly

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Argon Plasma Sustained in Different Discharge Configurations

Spectro-photometric determinations of Mn, Fe and Cu in aluminum master alloys

Heat Value Gas Chromatograph ISO standard version

X-MET8000. Trust but verify: Ensure product quality with Oxford Instruments latest handheld XRF analyser

Experimental study on laser marking of alumina

ProFoss for in-line process analysis of dairy powder

Fpollutant-free zero air for analytical

Review on Agriculture and Rural Development vol. 2. (1) ISSN

Metal Powder - the Raw Material of Future Production

Beechcraft Corporation Special Processes Index Special Processes that Require Approval to Perform

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

GEOLOGY 333 LAB 14. Lab Final Exam See information sheet for details

Certificate of Analysis

TITLE: Surface Decontamination of Zinc Compounds (Elemental Zinc Powder (Zn), Zinc Oxide (ZnO), and Zinc Acetate (Zn(O 2 CCH 3 ) 2 ) by DeconGel TM

Chemistry and Chemical Sampling Updated 2012

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Avio 200 ICP-OES Flat Plate

ISO INTERNATIONAL STANDARD

Magnetic De-burring & Polishing Machine

Advantages of Photodiode Array

Protection classification IP 23

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)


Resource Guide. Section 4: Ni-Resist

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

PMI-MASTER Compact. Cost-effective, rugged and precise mobile metal analyser. Routine analysis at entry level. Easy and fast testing

Issue February 2017 Valid to December ISO 9001 Registered Quality Management

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Understanding Coating Thickness Measurement Helmut Fischer

Sustainability Report 2014

Vickers Hardness Tester (Automatic Turret)

25%Cr SUPERDUPLEX

Leadership in Soft Magnetic Alloys

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

EQUIPMENT AND SYSTEM FOR VACUUM COATING METALLIZING, SPUTTERING, PLASMA and PECVD. Hybrid system KOLZER DGK 36

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

Effect of Precipitation Hardening on Microstructural Characteristics of 15-5 Ph Steel

Product Catalog. Spectrochemical Reference Materials. Quality Accreditations. Certified Reference Materials for Metals Analysis

OUTOTEC TOMRA SENSOR-BASED ORE SORTING SOLUTIONS BENEFITS

Vacuum Cap Furnace. New vacuum degassing and controlled atmosphere melting technology from Consarc.

Pelletizing technologies for iron ore

Bars. Nickel, Nickel-based and Copper-Nickel Alloys

WM2008 Conference, February 24-28, 2008, Phoenix, AZ Abstract #8216. Thermal Pretreatment For TRU Waste Sorting

Discover the variety of Metal Powders

Certificate of Analysis

FrelTec GmbH. SMD Shielded Power Inductors

ICP Expert software. Technical Overview. Introduction

Brinell Rockwell Vickers. Hardness Tester (Manual)

Trust but verify: Ensure product quality at all stages of production

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Using a standard Penning Gauge as a powerful means of monitoring and feedback control

Red Eye Multiphase Water-Cut Meter

TECHNICAL DATA SHEET

Electron Beam Melted (EBM) Co-Cr-Mo Alloy for Orthopaedic Implant Applications Abstract Introduction The Electron Beam Melting Process

SEMASPEC Test Method for Metallurgical Analysis for Gas Distribution System Components

Remote Sensing of CO from AIRS AIRS typically sees 82% of the globe each day

ARL Fire Assay Analyzer Optical Emission Spectrometer. Fast analysis of fire assay lead buttons with ultimate performance

1-Materials Science & Materials Engineering

Powder Plasma welding system consisting of Controller, power source, colulmn and boom, oscillator, welding positioner, water chiller

Allegheny Ludlum, LLC d/b/a ATI Flat Rolled Products. Materials Testing

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

MEDIUM-FREQUENCY CORELESS INDUCTION FURNACES

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Sensortherm. Digital Pyrometer. Temperature Measurement and Control. com

ENERGY HARVESTING APPLICATION FOR INDUSTRY 4.0. Dr. CARLES FERRER CTO AEInnova

Transcription:

fast and accurate metal analysis

Application fields Elemental analysis plays a crusial role in the quality control of the metal smelting, casting and processing industry. Skyray Instruments s are widely used for elemental analysis of ferrous and non-ferrous metals. and OES 8000 can simultaneously analyze dozens of elements with excellent precision and fast performance, greatly benefitting operators in metal industries. OES6000 is the instrument of choice for companies in the metal production and processing industry, who need a cost-effective and compact optical emission spectrometer. 1

Performance Advantages Based on the Multi-CCD detector and total spectrum technology, Optical Emission Spectrometer is able to detect all the spectral lines within the wavelength range. Optical Emission Spectrometer features a new design which eliminates the need of a vacuum pump and vacuum sealed chamber for accurate analysis. Thanks to its compact size, is a convenient instrument for the analysis of ferrous and non ferrous metals Fast analysis: 35 seconds testing Excellent reliability and repeatability: 24/7 operation Polychromator operates without the need of a vacuum pump Total spectrum technology simplifies installation of new matrix or channel Simplified calibration procedure with the standard samples Safe and eco-friendly analysis without chemical reagents 2

CARL ZEISS Grating and Optical lens Toshiba CCD Detector & Agilent Optical Fiber Technical Specifications Requirements Ambient temperature: 15-30 C Atmospheric humidity: <70% Power: Voltage 220V ± 5V 50Hz: single phase with protective ground Environment free from vibration, dust, strong electromagnetic interference, strong airflow or corrosive gases Auxiliary equipment Argon - The purity is above 99.999% AC parameter - 1 KVA stabilized power supply Grinding machine - for high hardness metal samples similar to: Steel, Nickel alloy, etc Lathe - for low hardness metal samples similar to: Aluminum, Copper, Zinc, Magnesium, etc Control Circuit Specifications Spectrometer design Paschen-Runge polychromator Temperature controlled at 34 ± 0.5 C Special casting materials reduce chamber deformation Other Specifications Spark Source Digital plasma generator High energy pre-spark (HEPS) Frequency: 100-1000Hz Current: 1-80A Grating Holographic concave grating; 3600 l/mm Dispersion of the first order spectrum: 1.2nm/mm Effective wavelength range: 200-500 nm Spark Stand 4mm analytical gap Jet stream technology No Argon consumption in standby mode Detector High-performance linear array CCD Analysis Time Depend on material-typical test 35 seconds Dimension and Weight Dimensions LxWxH: 45cm x 50cm x 30cm Weight: 30 kg Electrical Power Operation: max 700VA Standby mode: 40VA 3

Testing Procedure Reference The following reference standards should be used when testing with OES8000 ISO 14284 Steel and Iron-Sampling and Preparation of Samples for the Determination of Chemical Composition ASTM E 1806 Standard Practice for Sampling Steel and Iron for Determination of Chemical Composition ASTM E 716 Standard Practices for Sampling and Sample Preparation of Aluminum and Aluminum Alloys for Determination of Chemical Composition by Spectrochemical Analysis Preparation High hardness metal samples require grinding the surface. Typical samples include steel, Nickel, Cobalt alloy and others Low hardness metal samples require turning the surface with the lathe. Typical samples include Aluminum, Copper, Zinc, Magnesium alloys and others Analysis Place the sample on the spark stand and start the analysis with the software. The test is complete in less than 40 seconds and all the results of the customized elements are displayed.the results of the analysis can be stored in the software database or printed directly. 4

Test Example 5

Skyray Instruments USA, Inc 1717 N. Akard Street, Ste 2520 Dallas, Texas, 75201 USA +1 972 638 9035 sales@skyrayinstruments.com Skyray Instruments specializes in the R&D, manufacturing and sales of analytical and measuring instruments in Spectroscopy, Chromatography and Mass Spectroscopy fields. Our Products include X-ray Fluorescence Spectrometry, Atomic Absorption Spectrometry, Gas Chromatography, Inductively Coupled Plasma Spectrometry, Mass Spectrometry and many others Skyray has been providing customers around the world with reliable and affordable Scientific Instruments for more than 20 years Product description and specifications in this document are subject to change without notice. Copying, distributing or any use of material contained in this document for any commercial purpose without permission from Skyray Instruments USA, Inc is prohibited. Printed in USA