Certificate of Analysis

Similar documents
Sorting and Drying Code Price Unit. Sorting and Boxing of Samples, received as pulps SORTBOX 0.00 Sample

XRF DRIFT MONITORS DATA CALIBRATION MATERIAL

High Purity Acids Trace Elemental Analysis. Detect as low as 1 to 100 ppt

Where do we start? ocreate the Universe oform the Earth and elements omove the elements into their correct positions obuild the atmosphere and oceans

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

Families on the Periodic Table

AMIS0283. Certified Reference Material. Multi element-pgm ore Sudbury Basin, Canada. Certificate of Analysis

Part 1. Preparation and Color of Solutions. Experiment 1 (2 session lab) Electrons and Solution Color. Pre-lab Report, page 29

UK Baseline Geochemistry: A Key Environmental Yardstick

Lower Cost Higher Performance Graphite for LIBs. Prepared by: Dr. Edward R. Buiel President and CEO Coulometrics, LLC. Date: March 23, 2017

Evidence of Performance regarding the requirements for float glass according to EN 572

STANDARD DI VETRI E MATERIALI CERAMICI

This resource contains three different versions of the periodic table, including a blank one for colouring!

SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000

Groups of Elements 3B 5B 6B 7B 2 C. 10 Na. 36 Rb. 54 Cs. 86 Fr. 57 Ac. 71 Th. Nitrogen group. Alkali metals. Alkaline earth metals.

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of

Certificate of Analysis

Issue February 2017 Valid to December ISO 9001 Registered Quality Management

Effects of soil composition and mineralogy on the bioaccessibility of arsenic. from tailings and soil in gold mine districts of Nova Scotia

Dr Nick Voulvoulis. Presentation at the Industrial Waste & Wastewater Treatment & Valorisation conference May 2015, Athens, Greece

Accredited Laboratory

Summary of Geochemical Atlas Information

ANALYTICAL REFERENCE MATERIALS INTERNATIONAL Part of LGC Standards 3 Perimeter Road, Unit 9 Manchester, NH USA

High-Purity Acids & Reagents

Elements. The periodic table organizes elements by their chemical properties. Main Idea. Key Terms group period nonmetal family metal metalloid

Market Update for Rare Earths USGS Congressional Briefing Series December 13, 2013

Strong Acid Leachable Metals (SALM) in Soil - Prescriptive

Core Analysis with the Tracer

Table of Contents. Quality Management LIMS System... Customer Services...

E2S Denver Convention Center Denver, Colorado

CERTIFICATE OF ANALYSIS REVISED REPORT

Chapter 1.6. Polished Single-Crystal Silicon, Prime Wafers (all numbers nominal) Wafer Specification Table. Diameter 100 mm 4-inch 150 mm 6-inch

Corrosion Studies on GeoBrom HG520

Certified Reference Materials. Minerals Industrial XRF Drift Monitors Coal ROHS/Plastics

New GCSE 4462/02 SCIENCE A HIGHER TIER CHEMISTRY 1

Certificate of Analysis

Corrosion Studies on GeoBrom HG520

AMIS0402. Certified Reference Material. Certificate of Analysis

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CARBOWAX SENTRY Polyethylene Glycol (PEG) and Methoxypolyethylene Glycol (MPEG) Products

RWTH Aachen workshop on green resources & processing concepts for rare earth metals

Thermodynamic and Mobility Databases Overview

The Helmholtz Institute Freiberg Resource Technology Made in Germany

SPECTRAL INTERFERENCE IN X-RAY FLUORESCENCE ANALYSIS OF COMMON MATERIALS

The image part with relationship ID rid4 was not found in the file. Welcome

CERTIFICATE OF ANALYSIS

Corrosion Studies on GeoBrom HG520

Database. Sept , 2014, Aachen, Germany. Thermo-Calc Anwendertreffen

AIM: SWBAT determine the location of metals, nonmetals and metalloids on the periodic table. What is another name for a column in the periodic table?

EFFECT OF LEAD NITRATE ON CYANIDATION OF ANTIMONIAL REFRACTORY GOLD AND SILVER ORES

CERTIFICATE OF ANALYSIS

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

Soil quality and links to health

XRF S ROLE IN THE PRODUCTION OF MAGNESIUM METAL BY THE MAGNETHERMIC METHOD

Metals enable a sustainable society (Cu) Product & mineral centric systems. System integration & Design for Recycling

Technological Aspects of Metal Nanopowders

Introduction Materials scarcity in general, exponential growth

S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar

AAS - Atomic Absorption Mono Element ppm Standard Solutions (Spectro ECON)

Chemical quality of household water in Bangladesh

TOP INORGANIC STANDARDS

WG 5: Radionuclide Transfer to wildlife

SPECTRO XRF Report. SPECTRO xsortxhh03. Analysis of Solid Metal Samples. Summary

Chem. 451 (Spring, 2005) Final Exam (100 pts)

BRAMMER STANDARD GEOLOGICAL MATERIALS CATALOG HEXAVALENT CHROMIUM 84 HORNBLENDITE 31

Application of the Concepts of Exclusion, Exemption and Clearance

New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

BLACK STURGEON LAKES WATER QUALITY MONITORING

9 Toxins / 11 Essential Minerals

Preliminary Report on the International Energy Agency Mode of Occurrence Inter-laboratory Comparison: Phase I; USGS Results

9 Mineral particles, mainly windblown dust from local soil: Li, A1, Sc, (V), Cr, Fe, (Co), Ga, Y, La, Sm, Th, U;

AMIS0222. Certified Reference Material. Gold and copper ore, greenstone Bulyanhulu Mine, Tanzania. Certificate of Analysis

METALLIC MATERIALS SPECIFICATION HANDBOOK

WHERE SHOULD ALUMINUM GO IN THE PERIODIC TABLE?.pdf

Elemental Impurities Regulations View from a CRO

Analytical Services Division

Thin film deposition for next generation DRAM structures

MBH. Introduction. Element & Symbol Pack Sizes. Catalogue No. 26 X 1-Ag 26 X 10-Ag. Concentrations Available. Suppliers. France U.K.

Rare Earth Element Production from Coal

PROFICIENCY TESTING PROGRAMS SOILS & INPUTS

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

S-65 BERYLLIUM GRADE. Effective: April 11, SCOPE

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

Locked Cycle Leaching Test and Yellowcake Precipitation

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

2013 PROJECT REPORT FOR METALLURGICAL TESTING ON THE SAN ALBINO PROJECT

Our Profile. LPPM/ Pt & Pd Certified Reference Materials (CRM) Project Update

Certificate of Analysis

Metals from Coal Fly Ash. Recovering Rare Earth. Department of Civil & Environmental Engineering. Ross Taggart

AM metal powders from LPW. Comprehensive range of metal powders optimised for use on all AM machines. 24 hours from order to dispatch

Bertil Norén. Processing Manager, Björkdalsgruvan. Euromine Expo, Skellefteå June 15, 2016

Hydrochemical Routes to Recycle NiMH Batteries and Fluorescent Lamps

INORGANIC CHEMISTRY LANTHANIDES

Recovery of Rare Earth Elements from Solid Residue of El-Sela Ore, South Eastern Desert, Egypt

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

IMS INSTITUTE PROVIDER PROGRAMME FOR 2018

Critical Raw Materials for alternative energies: new end uses

SCOPE OF ACCREDITATION

Transcription:

Certificate of Analysis First issued: September 2010 Version: September 2010 GTS-2a Certified Reference Material for a Gold Ore Mill Tailings Table 1 GTS-2a Certified Values Within-lab Between-labs 95% Confidence Interval of Mean Al (no AD2) a % 6.96 0.11 0.22 0.12 As µg/g 124 4 11 5 Au (FA) b µg/g 0.272 0.009 0.011 0.005 Ba (no AD2) a µg/g 186 8 14 7 C % 2.011 0.021 0.063 0.041 Ca % 4.01 0.09 0.14 0.06 Co µg/g 22.1 0.8 1.7 0.7 Cu µg/g 88.6 2.9 6.1 2.5 Fe % 7.56 0.13 0.26 0.11 K (no AD2) a % 2.021 0.036 0.064 0.035 Mg (no AD2) a % 2.412 0.038 0.075 0.038 Mn µg/g 1510 30 120 50 Na (no AD2) a % 0.617 0.016 0.063 0.033 Ni µg/g 77.1 2.9 9.1 3.7 P % 0.0892 0.0030 0.0084 0.0036 S % 0.348 0.009 0.028 0.014 Si % 23.65 0.14 0.21 0.16 Sr (no AD2) a µg/g 92.8 2.2 6.0 3.2 Th (no AD2) a µg/g 1.244 0.125 0.090 0.076 Zn µg/g 208 7 21 9 a sets with digestions by two acids, usually hydrochloric and nitric acids, were excluded as method outliers based on statistical tests b fire assay techniques only i.e. sets by digestion excluded as statistical outliers

Table 2 GTS-2a Provisional Values Analyte Units Mean Within-lab Between-labs 95% Confidence Interval of Mean Al (AD2) a,b % 1.80 0.07 0.12 0.13 Be (no AD2) a,c µg/g 0.882 0.049 0.044 0.052 Cd e µg/g 0.58 0.10 0.21 0.12 Ce (no AD2) c µg/g 24.35 0.86 0.50 0.49 Ga (no AD2) c µg/g 21.1 0.7 3.6 2.6 Hg µg/g 0.220 0.028 0.047 0.036 La (no AD2) µg/g 9.44 0.31 0.62 0.49 LOI f % 9.87 0.04 0.25 0.19 Mg (AD2) a,b % 2.173 0.048 0.095 0.102 Mo µg/g 3.84 0.27 0.21 0.21 Nd (no AD2) a,c µg/g 16.57 0.56 0.71 0.79 Pb µg/g 17.9 1.4 5.7 2.6 Pr a µg/g 3.45 0.12 0.18 0.20 Rb (no AD2) c µg/g 57.7 1.5 2.3 2.0 Sb (no AD2) c µg/g 1.33 0.13 0.13 0.11 Sc (no AD2) c µg/g 29.3 0.7 3.0 2.0 Sm µg/g 4.58 0.11 0.44 0.37 Sr (AD2) a,b µg/g 63.2 1.5 1.8 2.0 Te µg/g 1.64 0.30 0.46 0.30 Ti (FUS) d µg/g 0.500 0.006 0.013 0.010 V (no AD2) c µg/g 166 6 30 17 Yb (T) a,g µg/g 4.41 0.12 0.21 0.23 W (no AD2) c µg/g 25.8 1.2 6.7 4.5 Zr (no AD2) c µg/g 114 6 26 15 a statistical analysis of the data warrants classification as provisional despite only 6 sets of data b includes digestion by two acids only, usually hydrochloric and nitric c sets by digestion by two acids, usually hydrochloric and nitric acids, excluded as method outliers based on statistical tests d includes fusions only e data fulfilled the conditions for certification, but the element was re-classified as provisional since much of the data had one significant figure f loss on ignition for a sample of 1-2 g for 0.25-3 hour at a temperature of 900 to 1050 C g includes only total recovery (T) methods such as digestion by four acids in a closed beaker, various fusions and instrumental neutron activation analyses; the exclusion of sets by acid digestions in an open beaker as method outliers was based on statistical tests GTS-2a September 2010 Page 2 of 5

Table 3 GTS-2a Informational Values No. No. accepted accepted laboratories laboratories / values / values Ag µg/g 0.64 11 / 51 Na (AD2) b % 0.015 5 / 26 Au (AD2,4) a µg/g 0.25 3 / 14 Nb (no AD2) d µg/g 4 7 / 34 Bi µg/g 0.3 7 / 34 Pd µg/g 0.002 3 / 15 Cr (AD2) b µg/g 140 7 / 37 Sn µg/g 1 7 / 34 Cr (T) c µg/g 270 5 / 25 Ta µg/g 0.3 3 / 15 Cs (no AD2) d µg/g 1.7 5 / 24 Tb (T) c µg/g 1.1 5 / 25 Dy (T) c µg/g 7 4 / 20 Ti (AD3,4) % 0.3 7 / 34 Er (T) c µg/g 4.4 4 / 20 Tl (AD4) µg/g 0.40 5 / 24 Eu (T) c µg/g 1.5 5 / 25 Tm (T) c µg/g 0.66 4 / 20 Gd (T) c µg/g 6.3 4 / 20 U µg/g 0.4 3 / 15 Hf (T) c µg/g 3.5 6 / 30 V (AD2) b µg/g 50 4 / 20 Ho (T) c µg/g 1.5 4 / 20 W (AD2) b µg/g 12 4 / 20 Li µg/g 27 7 / 34 Y (T) c µg/g 38 6 / 30 Lu (T) c µg/g 0.7 6 / 30 Zr (AD2) b µg/g 5 4 / 20 a includes digestion by two acids, usually hydrochloric and nitric acids, and four acids only b includes digestion by two acids, usually hydrochloric and nitric acids c includes only total recovery (T) methods such as digestion by four acids in a closed vessel, various fusions and instrumental neutron activation analyses; the exclusion of sets by acid digestions in an open beaker as method outliers was based on statistical tests d digestion by two acids, usually hydrochloric and nitric acids, was excluded as a method outlier based on statistical tests SOURCE GTS-2a is a gold ore mill tailings obtained from a tailings dam at the Porcupine gold mine in Timmins, Ontario, Canada. The raw material was donated by Goldcorp Canada Limited, Porcupine Gold Mine. The raw material for GTS-2a was obtained from the same source as its predecessor, GTS-2. DESCRIPTION The mineral species include: quartz (33.5%); clinochlore (14.0%); K-feldspar (13.5%); ankerite (13.5%); muscovite (11.4%); albite (4.3%); calcite (2.1%); siderite (1.7%); biotite (1.2%); rutile and magnetite (both at 0.7%); pyrite and anorthite (both at 0.6%); various other trace minerals including several silicates, rare earths, arsenopyrite, sphalerite, chalcopyrite, melonite, altaite, graphite and gold (for a total of 0.6%); apatite (0.5%); pyrrhotite and Mg-ferrite (0.3%); talc, ilmenite and gypsum (all at 0.1%); and epidote (0.01%). INTENDED USE GTS-2a is suitable for the analysis of various elements at major, minor and trace levels in tailings. Examples of intended use include quality control and method development. GTS-2a September 2010 Page 3 of 5

INSTRUCTIONS FOR USE GTS-2a should be used as is, without drying. The contents of the bottle should be thoroughly mixed before taking samples. The values herein pertain to the material when produced. CANMET-MMSL is not responsible for changes occurring after shipment. HANDLING INSTRUCTIONS Normal safety precautions for handling fine particulate matter are suggested, such as the use of safety glasses, breathing protection, gloves and a laboratory coat. METHOD OF PREPARATION The raw material was dried at 32 C, crushed, sieved to remove the plus 75 µm fraction. The recovery of the minus 75 µm fraction was 78%. The product was blended, and then bottled in 350-gram units. HOMOGENEITY The homogeneity of the stock was investigated using fifteen bottles chosen according to a stratified random sampling scheme. Three subsamples were analyzed from each bottle. The gold in 30-g subsamples was concentrated using lead fire assay and analyzed using inductively coupled plasma mass spectrometry. Each bottle in a second set of 15 randomly chosen bottles was subsamples into 8 subsamples and three subsamples were analyzed. Subsamples of 0.25g grams were digested using four acids, hydrofluoric, hydrochloric, nitric and perchloric acids, and analyzed for copper and nickel by inductively coupled plasma atomic emission spectrometry and for lead by inductively coupled plasma mass spectrometry. Subsamples of 0.15 grams from each of the 3 subsamples per bottle were analyzed for sulphur using a combustion apparatus with infrared detection. Use of a smaller subsample than specified above will invalidate the use of the certified values and associated parameters. A one way analysis of variance technique (ANOVA) 1 was used to assess the homogeneity of these elements. No significant between-bottle variation was observed for copper, gold, nickel, lead and sulphur. CERTIFIED VALUES Twenty-six industrial, commercial and government laboratories participated in an interlaboratory measurement program using methods of their own choosing. Methods for the analysis of gold included pre-concentration by lead fire assay, digestion by two and four acids followed by determination using flame atomic absorption spectrometry, inductively coupled plasma optical emission spectroscopy, inductively coupled plasma mass spectrometry, gravimetric analysis and instrumental neutron activation analysis. The methods used for various other elements included multi-acid digestions in open or closed vessel, microwave digestion, various types of fusions, and followed by determination by flame atomic absorption spectroscopy, inductively coupled plasma optical emission spectroscopy, inductively coupled plasma mass spectrometry. Various types of fusions followed by X-ray fluorescence, as well as instrumental neutron activation analysis were used to determine several elements. Hydride generation atomic absorption spectrometry was used for the determination of arsenic and tellurium. Loss on ignition was determined using sample weights of 1-2 grams for 0.25-3 hour at a temperature of 900 to 1050 C. Sulphur was determined by various acid digestions followed by inductively coupled plasma optical emission spectrometry or gravimetric finish; preparation of a fused pellet followed by X-ray fluorescence; as well as combustion with infrared spectrometry. Silicon was determined by various fusions or acids digestions followed by inductively coupled plasma optical emission spectroscopy, gravimetric analysis, or fusion followed by X-ray fluorescence. ANOVA was used to calculate the consensus values and other statistical parameters from the interlaboratory measurement program. Values are deemed to be certified if derived from 10 or more sets of data that meet CCRMP statistical criterion regarding the agreement of the results. Twenty elements GTS-2a September 2010 Page 4 of 5

were certified (see Table 1). Many certified elements exclude digestion by two acids based on statistical tests. Full details of all work, including the statistical analyses, the methods and the names of the participating laboratories are contained in the Certification Report. For more details on how to use reference material data to assess laboratory results, users are directed to ISO Guide 33:2000, pages 14-17, and the publication, Assessment of laboratory proficiency using CCRMP reference materials, at www.ccrmp.ca. UNCERTIFIED VALUES Twenty-four provisional values (Table 2) were derived from 8 or 9 sets of data that fulfill the CCRMP statistical criterion regarding agreement; or 10 or more sets of data, that do not fulfill the CCRMP statistical criteria required for certification; or 6 sets of data for which the statistical analysis of the data warranted provisional status. This latter group includes (i) aluminum, magnesium and strontium by digestion with two acids, (ii) beryllium and neodymium by all methods except digestion with two acids, (iii) ytterbium by total recovery methods and (iv) praseodymium by all methods. Informational values for 28 elements, shown in Table 3, were derived from the means of a minimum of 3 sets of data. TRACEABILITY The values quoted herein are based on the consensus values derived from the statistical analysis of the data from the interlaboratory measurement program, and the standards used by the individual laboratories. The report gives the available details. CERTIFICATION HISTORY GTS-2a is a new material. PERIOD OF VALIDITY The certified values are valid until September 30, 2032. The stability of the material will be monitored every two years for the duration of the inventory. Updates will be published on the CCRMP web site. LEGAL NOTICE CANMET-MMSL has prepared this reference material and statistically evaluated the analytical data of the interlaboratory measurement program to the best of its ability. The purchaser, by receipt hereof, releases and indemnifies CANMET-MMSL from and against all liability and costs arising out of the use of this material and information. CERTIFYING OFFICERS Maureen E. Leaver CCRMP Coordinator Joseph Salley Data Processor FOR FURTHER INFORMATION The Certification Report is available free of charge upon request to: CCRMP Telephone: (613) 995-4738 CANMET-MMSL (NRCan) Facsimile: (613) 943-0573 555 Booth Street, room 433 E-mail: ccrmp@nrcan.gc.ca Ottawa, Ontario, Canada K1A 0G1 REFERENCES 1. Brownlee, K.A., Statistical Theory and Methodology in Science and Engineering; John-Wiley and Sons, Inc.; New York; 1960. GTS-2a September 2010 Page 5 of 5