Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Similar documents
FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Important Notice. QuietRock by PABCO Gypsum Cherry Street Newark, CA

Evaluation VerteTek Coat of Silence

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: PAC INTERNATIONAL, LLC

CONDUCTED: 26 November 2013 Page 1 of 6

CONDUCTED: 26 November 2013 Page 1 of 6

RIVERBANK ACOUSTICAL LABORATORIES

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: THERMA-TRU DOORS. SERIES/MODEL: Slimline. TYPE: 8/0 Sliding Patio Door

H R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to AMORIM CORK COMPOSITES

This page was. intentionally. left blank

BENEFITS OF GREEN GLUE IN STANDARD WALL CONSTRUCTION

QuietRock 530 RF Application Notes

KINETICS NOISE CONTROL TEST REPORT #AT001067

RESILIENT SOUND ISOLATION CLIPS

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: THERMA-TRU CORPORATION

REPORT HOLDER: KINETICS NOISE CONTROL 6300 IRELAN PLACE DUBLIN, OHIO EVALUATION SUBJECT: KINETICS NOISE CONTROL WAVE HANGER

-Letter - Tables 1 and 2 - Figure 1 - Exhibits 1 through 6

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Acoustic Testing of CLT and Glulam Floor Assemblies Nordic Engineered Wood Report No. A August 2016 CONSTRUCTION

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

SECTION SOUND ISOLATION

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 492 AND ASTM E Rendered to REGUPOL AMERICA

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

Installation Guide and Safety Manual

KINETICS NOISE CONTROL TEST REPORT #AT001035

Optimizing Ceiling Systems and Lightweight Plenum Barriers

RSIC-1 ACOUSTIC ASSEMBLY

research report Fire Resistance Ratings of Load Bearing Steel Stud Walls With Gypsum Wallboard Protection RESEARCH REPORT RP REVISION 2007

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

Presented By: Jim O Neill. Acoustics

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

WHY I SHOULD SPECIFY AND USE FAS TRACK 1000?

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Soundproofing Home Theaters & Media Rooms

Analysis 4 Acoustical Analysis of Interior Partitions- Breadth

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

Product Selection Guide and Architectural Assemblies

Shaftwall and Area Separation Wall Systems.

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

JUST THE FACTS! EcoTouch PINK FIBERGLAS Insulation The best choice for home energy savings

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

Guide for Sound Insulation in Wood Frame Construction

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

BXUV.U465. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

138 H-STUD AREA SEPARATION WALL SYSTEM

The GlasRoc Shaftliner Type X advantage...

Technical Report. Calculated R-Values for Hybrid Insulation Assemblies that Contain Hy-Fi Reflective Insulation

Product Test Summaries

Appendix D. -Weyerhaeuser Fire Rated Assembly Listings-

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

2013 COMMERCIAL PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: CITADEL ARCHITECTURAL PRODUCTS, INC.

Noise Control Of Building

PinkWood Ltd. Revised September 29, 2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: STO CORP.

RSIC-1. RSIC-1, the Low Cost, High Performance, Noise control Solution. RSIC-1 specifications:

SOUND INSULATION TESTING IN DWELLINGS

TEST REPORT. Report No.: B Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

Noise-Foil Acoustic Metal Panels Sound Absorption Systems for Industry & Commerce

Quantity take-off details

Section Sound Control

Design No. U465 BXUV.U465 Fire Resistance Ratings - ANSI/UL 263. Design No. U465

Technical Features Sound Construction Design Aid For Office Acoustics

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Floors Walls Ceilings

RSIC-1 SOUND ISOLATION SYSTEMS RSIC-1 INSTALLATION GUIDE

Drywall and Plastering

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Corporate Environments

SECTION GYPSUM WALLBOARD. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Thermal Performance of Nvelope NV1 Clip System

GypLyner UNIVERSAL Metal framed wall lining system

WoodWorks. Learning Objective. Presentation Overview. Fire Protection II Requirements for rated assemblies and common detailing

Gold Bond BRAND Gypsum Sheathing

June Residential Refurbishment Separating walls

GIB Quiet Clip GIB CBI March Features and Benefits

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

July 23, 2010 PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

THERMAL DESIGN GUIDE FOR EXTERIOR WALLS PUBLICATION RG-9405 JANUARY 1995

NOISE CONTROL OF BUILDINGS

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

ROCKMAX MAG CEMENT BOARD

Nu-Wool U382 2 Hour Firewall Guide Please note that this firewall can only be installed by approved Nu-Wool U382 installers

Transcription:

Important Notice In August 1, 2013, PABCO Gypsum, a division of PABCO building products, LLC acquired the QuietRock business and operations from Serious Energy, Inc. Serious Energy, Inc. corporate structure and legal name changed through the years from Quiet Solution, Inc. to Serious Materials, Inc to Serious Energy, Inc. The acquisition of the QuietRock business by PABCO Gypsum includes the products, technical data, test reports and other intellectual property. For the avoidance of confusion, references to Quiet Solution, Serious Materials, or Serious Energy used within test reports, in general, should be understood as references to PABCO Gypsum as of August 1, 2013. QuietRock by PABCO Gypsum 37851 Cherry Street Newark, CA 94560 1.800.797.8159 www.quietrock.com

FOR: Quiet Solution, LLC Sound Transmission Loss Test Sunnyvale, CA ON: ID 03: QuietRock 510 + 5/8" Type X Gypsum, 24" on Center Steel Stud Wall with R-13 Fiberglass and 5/8" Type X Gypsum Page 1 of 4 CONDUCTED: 25 January 2007 TEST METHOD Unless otherwise designated, the measurements reported below were made with all facilities and procedures in explicit conformity with the ASTM Designations E90-04 and E413-04, as well as other pertinent standards. Riverbank Acoustical Laboratories has been accredited by the U.S. Department of Commerce, National Institute of Standards and Technology (NIST) under the National Voluntary Laboratory Accreditation Program (NVLAP) for this test procedure (NVLAP Lab Code: 100227-0). A description of the measuring technique is available separately. DESCRIPTION OF THE SPECIMEN The test specimen was designated by the client as ID 03: QuietRock 510 + 5/8" Type X gypsum, 24" on center steel stud wall with R-13 fiberglass and 5/8" Type X gypsum. The overall dimensions of the specimen as measured were nominally 2.46 m (97 in.) wide by 2.74 m (108 in.) high and 137 mm (5.375 in.) thick. The specimen was installed by the client directly into the laboratory's 2.74 m (9 ft) by 4.27 m (14 ft) wood-lined steel frame. A substantial filler wall was used in the remaining open area. Both the filler wall and test specimen were sealed on the periphery (both sides) with dense mastic. The description of the specimen was as follows: The wall consisted of 25 gauge steel framing with R-13 fiberglass batt insulation. Both sides of the wall had a layer of 5/8 inch Type X gypsum board. One side was finished with a layer of QuietRock 510 (QR 510). A more detailed description of the wall assembly appears in the sections below. Track, Studs and Insulation: Two 92 mm (3.625 in.) wide 25 gauge 2.74 m (108 in.) long steel runners were attached to the floor and ceiling with 32 mm (1.25 in.) Type S screws 610 mm (24 in.) on centers. Five (5) 92 mm (3.625 in.) wide 25 gauge 2.73 m (107.5 in.) long steel studs were spaced on 610 mm (24 in.) centers. The end studs were attached to the frame with 32 mm (1.25 in.) long screws spaced on 610 mm (24 in.) centers. All cavities formed by the track and studs were filled with faced R-13 fiberglass insulation measuring 89 mm (3.5 in.) thick. The total weight of the insulation was 9.3 kg (20.5 lbs).

Quiet Solution, LLC 25 January 2007 Page 2 of 4 Gypsum Wallboard: On both sides, a layer of 16 mm (0.625 in.) thick Type X gypsum board was applied vertically to the studs. The boards were attached to the studs with #6, 41 mm (1.625 in.) long bugle head drywall screws at 406 mm (16 in.) on centers. On one side, a layer of 13 mm (0.5 in.) thick QR 510 board was applied vertically to the studs. The boards were attached to the studs with #8, 64 mm (2.5 in.) long bugle head drywall screws at 406 mm (16 in.) on centers. Total weight of the gypsum board as measured was 138.8 kg (306 lbs.). Total weight of the QR 510 board as measured was 66.7 kg (147 lbs.). All joints and seams were staggered for each board layer application. Joints were sealed with QuietSeal 350 (QS 350) acoustical caulk and metal taped. Screw heads remained exposed. The weight of the specimen as measured was 224 kg (495 lbs.), an average of 33.2 kg/m 2 (6.8 lbs/ft 2 ). The transmission area used in the calculations was 6.7 m 2 (72.5 ft 2 ). The source and receiving room temperatures at the time of the test were 19±2ºC (67±2ºF) and 48±2% relative humidity. The source and receive reverberation room volumes were 178 m 3 (6,298 ft 3 ) and 177 m 3 (6,255 ft 3 ), respectively.

Quiet Solution, LLC 25 January 2007 Page 3 of 4 TEST RESULTS Sound transmission loss values are tabulated at the eighteen standard frequencies. A graphic presentation of the data and additional information appear on the following pages. The precision of the TL test data is within the limits set by the ASTM Standard E90-04. FREQ. T.L. C.L. DEF. FREQ. T.L. C.L. DEF. 100 19 1.18 800 57 0.16 125 34 0.70 4 1000 57 0.17 160 39 0.79 2 1250 58 0.15 200 41 0.63 3 1600 58 0.11 250 46 0.47 1 2000 54 0.09 4 315 49 0.30 1 2500 53 0.09 5 400 51 0.28 2 3150 57 0.08 1 500 53 0.19 1 4000 59 0.07 630 55 0.22 5000 62 0.05 ABBREVIATION INDEX STC=54 FREQ. = FREQUENCY, HERTZ, (cps) T.L. = TRANSMISSION LOSS, db C.L. = UNCERTAINTY IN db, FOR A 95% CONFIDENCE LIMIT DEF. = DEFICIENCIES, db<stc CONTOUR (SUM OF DEF = 24) STC = SOUND TRANSMISSION CLASS Tested by Approved by Dean Victor David L. Moyer Senior Experimentalist Laboratory Manager

SOUND TRANSMISSION REPORT RAL - TL07-030 Page 4 of 4 STC= 54 TRANSMISSION LOSS SOUND TRANSMISSION LOSS CONTOUR