TYPICAL BEARING WALL FRAMING

Similar documents
GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

2003 International Residential Building Code

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

One and Two Family Additions

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Administrative Changes

Building Guide. Colorado Chapter of the International Code Council

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

R Code and Commentary for 2012 NC Residential Code final 03/06/13

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Formulating a Korea Industrial Standard for light-frame wood construction

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

POST FRAME BUILDING STANDARDS

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

14' x 24' Garage Plan

Applying for Permits to build a new house in Linn County

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

GETTING STARTED... 2 YOUR LIST OF PRODUCTS... 2 WHAT THAT LIST BECOMES... 2 PRODUCTS CREATED AS ENVISIONEER ELEMENTS... 3

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient,

Introducing TJ Insulated Structural Framing Components

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

LUMBER: USE IN CONSTRUCTION

LVL Product Guide 2.0E LVL 1.5E LVL

COVERED AND SCREENED PORCHES: WHAT YOU NEED TO KNOW

Wood Frame Construction Manual for One- and Two-Family Dwellings 2015 EDITION WORKBOOK

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Existing Hangar. Existing Hangar 3'-7" New Stairs. Handrail. Close in Opening Frame with 2x4's 25'-7" NEW OFFICE 1 19'-8" Field Verify All Dimensions

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

RESIDENTIAL DETACHED GARAGE HANDOUT

FACT SHEET #2 DECK INFORMATION

Residential Detached Garage Handout

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

Residential Inspector s Guide: Building and Energy based on the 2009 International Residential Code Chapters 1-11

4 EXTREME FOUNDATION PANELS

CH. 9 WOOD CONSTRUCTION

Residential Decks 1 & 2 Family Dwellings and Townhouses City of Owatonna BUILDING DEPARTMENT

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

GARAGE MAIN FLOOR PLAN SDSCAD Specialized Design Systems

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

PRESENTATION OUTLINE MUBEC & IRC APPLICABILITY & ADMIN. 6/17/2015 RESIDENTIAL STRUCTURAL SYSTEMS. Carmen B. Bombeke, P.E.

Temporary Construction Loads Over I-Joist Roofs And Floors

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

Each proposed project will be reviewed for compliance with the following codes as applicable.

LPI 56 Technical Guide

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems

Modular Wood Framing Goes Vertical

RESIDENTIAL BUILDING PLAN REQUIREMENTS

PinkWood Ltd. Revised September 29, 2017

SECTION PLATE CONNECTED WOOD TRUSSES

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

Requirements for Additions/Enclosed Deck/Finished Bonus Room/Dormer

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

Installation Guide and Safety Manual

ILLUSTRATED GUIDE. For Seismic Design of Houses. Lateral Bracing Requirements Part 9 BC Building Code 2012

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

TRAINING. To access the Truss Store go to any of the computers at the building materials desk and click on Vendor Catalogs = > Truss Store.

KS SERIES - VERTICAL INSTALLATION

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

Fairfax County, Virginia

Phase IIIA Education Building

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

Thermal Bridging in Residential Construction

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

Inspection of New One- and Two- Family Dwellings

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

Prescriptive Residential Wood Deck Construction Guide Based on the 2012 International Residential Code

This tip sheet may be used as a guide for single-family residential uncovered deck permits.

Residential Accessory Structures & Room Additions

Gold Bond BRAND Gypsum Sheathing

MAX-CORE I-JOIST DESIGN MANUAL-US

CHAPTER 23 WOOD SECTION BC 2301 CONVENTIONAL LIGHT-FRAME WOOD CON- GENERAL STRUCTION.

Report on Structural Stability of Engineered Lumber in Fire Conditions

The System Slotted Deflection Track (pat# 5,913,788)

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

The better way to build TM

Joint Systems. System No. FF-D-0044

RESILIENT SOUND ISOLATION CLIPS

Technical Data for. Headers. and Beams

Department of Building and Zoning Deck Handout for ONE AND TWO FAMILY CONSTRUCTION

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

Transcription:

BASIC WOOD FRAMING City of Grand Rapids Building Safety Division 218-326-7601 www.grandrapidsmn.org This handout is intended only as a guide and is based in part on the 2007 Minnesota State Building Code, Grand Rapids City ordinances, and good building practice. While every attempt has been made to insure the correctness of this handout, no guarantees are made to its accuracy or completeness. Responsibility for compliance with applicable codes and ordinances falls on the owner or contractor. For specific questions regarding code requirements, refer to the applicable codes or contact your local Building Safety Division. 2X Double top plate TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min. 2X studs 16 or 24 O.C. Header made of two pieces of 2X material on edge Jack studs to support header (ea. end) 2X Bottom plate 1

STUD SIZE MAXIMUM HEIGHT SIZE, HEIGHT AND SPACING OF WOOD STUDS TABLE R602.3(5) MAXIMUM SPACING ROOF AND CEILING ONLY BEARING WALLS MAXIMUM MAXIMUM SPACING SPACING ONE FLOOR, TWO FLOORS, ROOF, AND ROOF AND CEILING CEILING MAXIMUM SPACING ONE FLOOR ONLY NONBEARING WALLS MAXIMUM MAXIMUM HEIGHT SPACING 2X4 10 24 16-24 14 24 2X6 10 24 24 16 24 20 24 TYPICAL FRAMING FOR NON-BEARING WALLS OR BASEMENT WALLS 3-inch-by-6-inch by a 0.036-inch-thick galvanized steel plate nailed to each segment by six 8d nails on each side or secure to framing above. 24 Max. 2X studs 16 or 24 O.C. Header may be 2X4 laid flat with no jack studs for openings up to 8 wide if distance from header to plate above is not more than 24. No blocking required above header. Plates on concrete floors must be treated unless there is a vapor barrier under the slab. 2

LAYING OUT WALLS 16 AND 24 ON CENTER 16 O.C. 16 O.C. 16 O.C. Starting 2 nd stud at 16 or 24 to center results in wall finishes breaking on the center of studs to reduce waste. Two different methods of framing corners that result in backing for drywall 24 O.C. FRAMING OPENINGS IN BEARING WALLS Header sized per header table Single or double jack studs per header table 3

GIRDER AND HEADER SPANS FOR INTERIOR BEARING WALLS (IN FT/IN) TABLE R502.5(2) (#2Hem Fir or SPF) HEADERS AND GIRDERS One floor only Two floors SIZE BUILDING WIDTH (FT) 20 24 28 32 SPAN (JACK SPAN (JACK SPAN (JACK SPAN (JACK 2-2X4 3-1 (1) 2-11 (1) 2-8 (1) 2-7 (1) 2-2X6 4-6 (1) 4-3 (1) 3-11 (1) 3-9 (1) 2-2X8 9-1 (1) 5-4 (1) 5-0 (2) 4-9 (2) 2-2X10 7-0 (2) 6-7 (2) 6-1 (2) 5-9 (2) 2-2X12 8-1 (2) 7-7 (2) 7-0 (2) 6-7 (2) 3-2X8 7-2 (1) 6-9 (1) 6-3 (1) 5-11 (2) 3-2X10 8-9 (1) 8-2 (1) 7-7 (2) 7-2 (2) 3-2X12 10-2 (2) 9-6 (2) 8-10 (2) 8-3 (2) 4-2X8 9-0 (1) 8-3 (1) 7-8 (1) 7-3 (1) 4-2X10 10-1 (1) 9-5 (1) 9-0 (1) 8-4 (2) 4-2X12 11-9 (1) 10-11 (2) 10-2 (2) 9-8 (2) 2-2X4 2-2 (1) 2-0 (1) 1-10 (1) 1-9 (1) 2-2X6 3-2 (2) 3-0 (2) 2-9 (2) 2-7 (2) 2-2X8 4-1 (2) 3-10 (2) 3-6 (2) 3-4 (2) 2-2X10 4-11 (2) 4-7 (2) 4-3 (2) 4-1 (3) 2-2X12 5-9 (2) 5-5 (3) 5-0 (3) 4-9 (3) 3-2X8 5-1 (2) 4-9 (2) 4-5 (2) 4-2 (2) 3-2X10 6-2 (2) 5-9 (2) 5-4 (2) 5-1 (2) 3-2X12 7-2 (2) 6-9 (2) 6-3 (2) 5-11 (3) 4-2X8 6-1 (1) 5-8 (2) 5-3 (2) 5-0 (2) 4-2X10 7-2 (2) 6-8 (2) 6-2 (2) 5-10 (2) 4-2X12 8-4 (2) 7-9 (2) 7-2 (2) 6-10 (2) Rim or band joist TYPICAL FLOOR FRAMING Tail joists must be supported by hangers at the header if the span exceeds 12 Lap joists 3 min Header and trimmer joists double if header more than 4 span Use hangers if header spans more than 6 Joists 16, 19.2 or 24 o.c. 4

CRAWL SPACES Treated plate Treated joists if less than 18 to ground Treated beam if less than 12 to ground Treated column FLOOR JOIST SPANS #2 SPF TABLE R502.3.1(2) Joist spacing 2X6 2X8 2X10 2X12 16 O.C. 9-4 12-3 15-5 17-10 19.2 O.C. 8-9 11-6 14-1 16-3 24 O.C. 8-1 10-3 12-7 14-7 GIRDERS AND HEADERS Roof and ceiling Roof, ceiling and one center-bearing floor GIRDER SPANS AND HEADER SPANS FOR EXTERIOR BEARING WALLS - #2 HEM FIR OR SPF TABLE R502.5(1) 20 28 36 SIZE Span NJ Span NJ Span NJ 2-2 4 2-10 1 2-6 1 2-3 1 2-2 6 4-2 1 3-8 2 3-3 2 2-2 8 5-4 2 4-7 2 4-1 2 2-2 10 6-6 2 5-7 2 5-0 2 2-2 12 7-6 2 6-6 2 5-10 3 3-2 8 6-8 1 5-9 2 5-2 2 3-2 10 8-2 2 7-0 2 6-4 2 3-2 12 9-5 2 8-2 2 7-4 2 4-2 8 7-8 1 6-8 1 5-11 2 4-2 10 9-5 2 8-2 2 7-3 2 4-2 12 10-11 2 9-5 2 8-5 2 2-2 4 2-7 1 2-3 1 2-0 1 2-2 6 3-9 2 3-3 2 2-11 2 2-2 8 4-9 2 4-2 2 3-9 2 2-2 10 5-9 2 5-1 2 4-7 3 2-2 12 6-8 2 5-10 3 5-3 3 3-2 8 5-11 2 5-2 2 4-8 2 3-2 10 7-3 2 6-4 2 5-8 2 5

Roof, ceiling and one clear span floor Roof, ceiling and two centerbearing floors Roof, ceiling, and two clear span floors 3-2 12 8-5 2 7-4 2 6-7 2 4-2 8 6-10 1 6-0 2 5-5 2 4-2 10 8-4 2 7-4 2 6-7 2 4-2 12 9-8 2 8-6 2 7-7 2 2-2 4 2-5 1 2-1 1 1-10 1 2-2 6 3-6 2 3-1 2 2-9 2 2-2 8 4-6 2 3-11 2 3-6 2 2-2 10 5-6 2 4-9 2 4-3 2 2-2 12 6-4 2 5-6 3 5-0 3 3-2 8 5-7 2 4-11 2 4-5 3 3-2 10 6-10 2 6-0 2 5-4 2 3-2 12 7-11 2 6-11 2 6-3 2 4-2 8 6-6 1 5-8 2 5-1 2 4-2 10 7-11 2 6-11 2 6-2 2 4-2 12 9-2 2 8-0 2 7-2 2 2-2 4 2-4 1 2-0 1 1-9 1 2-2 6 3-5 2 3-0 2 2-8 2 2-2 8 4-4 2 3-9 2 3-5 2 2-2 10 5-3 2 4-7 3 4-2 3 2-2 12 6-1 2 5-4 3 4-10 3 3-2 8 5-5 2 4-9 2 4-3 2 3-2 10 6-7 2 5-9 2 5-3 2 3-2 12 7-8 2 6-9 2 6-1 3 4-2 8 6-3 2 5-6 2 4-11 2 4-2 10 7-7 2 6-8 2 6-0 2 4-2 12 8-10 2 7-9 2 7-0 2 2-2 4 2-0 1 1-8 1 1-5 2 2-2 6 2-11 2 2-7 2 2-3 2 2-2 8 3-9 2 3-3 2 2-11 3 2-2 10 4-7 3 4-0 3 3-6 3 2-2 12 5-4 3 4-7 3 4-1 4 3-2 8 4-8 2 4-1 2 3-8 2 3-2 10 5-9 2 4-11 2 4-5 3 3-2 12 6-8 2 5-9 2 5-2 3 4-2 8 5-5 2 4-8 2 4-2 3 4-2 10 6-7 2 5-9 2 5-1 2 4-2 12 7-8 2 6-8 2 6-5 3 FURRING VS. FRAMING Wood framing supporting gypsum board must be 2 X2 or larger 1 X Furring strips may only be used over solid backing or framing spaced not more than 24 o.c. Furring strips placed against a concrete or masonry wall must be treated unless a vapor retarder is placed between the wall and furring strips 6

CEILING JOIST SPANS FOR #2 HEM FIR AND SPF NO STORAGE IN ATTIC 2 x 4 2 x 6 2 x 8 2 x 10 12 Hem Fir 11-7 18-2 24-0 26+ o.c. SPF 11-10 18-8 24-7 26+ 16 Hem Fir 10-6 16-6 21-9 26+ o.c. SPF 10-9 16-11 22-4 26+ 24 Hem Fir 9-2 14-5 18-6 22-7 o.c. SPF 9-5 14-9 18-9 22-11 Ridge board 1X min At least as deep as rafter cut ROOF FRAMING Rafters Collar ties 1X4 min spaced 48 o.c. max. Ceiling joists ENGINEERED LUMBER This handout does not cover engineered lumber such as floor or roof trusses, I joists, glue-laminated members, structural composite lumber, and similar products. Refer to the manufacturer s installation instructions for further information. RAFTER SPANS FOR #2 HEM FIR AND SPF 2 x 4 2 x 6 2 x 8 2 x 10 12 Hem Fir 6-7 9-7 12-2 14-10 o.c. SPF 6-8 9-9 12-4 15-1 16 Hem Fir 5-8 8-4 10-6 12-10 o.c. SPF 5-9 8-5 10-8 13-1 24 Hem Fir 4-8 6-9 8-7 10-6 o.c. SPF 4-8 6-11 8-9 10-8 OTHER FRAMING HANDOUTS Other handouts are available on cutting, boring and notching framing, fireblocking, gypsum wall board, fasteners, and a host of other code requirements pertaining to wood framing. 7