EACC-601. Combination Louver/Damper Concealed Actuator. Application and Design. Standard Construction

Similar documents
EAD-635. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost)

ESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

EDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)

SED-501. Sightproof Louver Drainable Blade. Application and Design

ESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

ESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

EDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

ESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-130S. Thin-line Louver Frameless. Application and Design. Standard Construction. Options (at additional cost)

ESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

Stationary Louvers. Product Type Model Description EDD-401, 601 ESD-202, 403, 435, 603, 635 EDJ-202, 401, 430, 601 EDK-402, 430, 602 ESID-430

ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing

Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.

EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER

Wall Louvers (10200)

SECTION LOUVERS AND VENTS

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

SPECIFICATION SECTION PART 1 GENERAL

SP Standard Profile. Flanged to Duct Install Type THERMAL BREAKS OPPOSED ACTION PARALLEL ACTION. T.A. Morrison & Co. Inc.

TMS 152 / 152T / 152XT TECHNICAL MANUAL

TMS 114 XT TECHNICAL MANUAL

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

Louvers, Screens & Grilles /RUS BuyLine 3966

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Severe Duty Louvered Products. Miami-Dade County Qualified, Florida Product Approved, Wind-Driven Rain, FEMA 361 and Sand Louver

SECTION HVAC GRAVITY VENTILATORS

SPECIFICATIONS: Architectural Aluminum Railings

Brise Soleil Fixed Sunshades

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Fire Dampers. Required information:

Architectural Coatings. to HVAC and Life Safety. A Balanced Approach

SECTION ALUMINUM WINDOWS

ALUMINIUM SAND TRAP LOUVER : CONSTRUCTION

SECTION ALUMINUM STORM WINDOWS

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

SECTION SECTIONAL OVERHEAD DOORS

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

SECTION EXTERIOR GRILLS AND SCREENS

FIBERGLASS ROUND CONTROL DAMPERS. Model K-RD INTRODUCTION M.K. PLASTICS PROVIDES FOUR DAMPER MODELS K-RD SUGGESTED SPECIFICATION

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

CASEMENT PROJECT OUT SERIES 6400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4

ALL-ALUMINUM DOOR & WINDOW FRAMING

SECTION DIRECTORIES

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

SECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

SECTION IMPACT RESISTANT WALL PROTECTION

Series Heavy Commercial Projected Window

SECTION COLUMN COVERS

RPR Insul-Mate Sheet and Roll Jacketing

CASEMENT PROJECT OUT SERIES 4400 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 4

Place & Connect Pumping Stations

A. Access doors and frames are part of an access door and frame allowance.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

A. Air diffusers, grilles, and registers: Ratings certified by Air Diffusion Council.

Series 510-I Thermal Heavy Commercial Projected Window

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

HORIZONTAL SLIDER SERIES 600 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.

HORIZONTAL SLIDER SERIES 910 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

HORIZONTAL SLIDER SERIES 900 ANSI/AAMA/NWWDA 101/I.S Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.66. Main Frame Depth: 4

SECTION AIR FILTERS

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

Ultra Aluminum Fence, Rail & Gate Specifications

SWING DOOR SPECIFICATION

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

SL150 Guide Specification

DOUBLE HUNG SERIES 860 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F. 50. Thermal U Value:.61. Main Frame Depth: 4

VITRABOND Aluminum Composite Panel Façade System Specification Template

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SINGLE HUNG SERIES 810 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: C.R.F.: 50. Thermal U Value:.61. Main Frame Depth: 4

TC Series. Commercial Sectional TC Series

REIMAGINE METAL COLOR THAT TRANSFORMS

Sapphire Metal Tile Roofing System

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

Specifications for FL-100 Soffit Panel


MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Guide Specification SDP 200

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

University of Houston Master Construction Specifications Insert Project Name SECTION AIR DISTRIBUTION DEVICES PART 1 - GENERAL

where high efficiency is the standard

Architectural and Ornamental Metals

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ALUMINUM COMPOSITE WALL PANEL SYSTEM

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

Alply CLASSIC WALL Architectural Insulated Panel Wall System

SECTION DECORATIVE METAL AND GLASS RAILING

Custom fabrication in two weeks or less, guaranteed.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

Transcription:

Application and Design Concealed Actuator is a combination louver/damper designed to protect air intake and exhaust openings in building exterior walls that, at times, require tight air shut off. Design incorporates a drainable head member, drainable stationary blades, operable blades and a concealed actuator within the louver sill. When the operable blades are open, airflow is permitted through the louver, when the blades are closed, a tight seal is created to prevent the passage of air. Standard Construction Frame........Heavy gauge extruded 6063-T5 aluminum, 6 in. x 0.125 in. nominal wall thickness Blades........Stationary blade: drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. nominal wall thickness, positioned at 45º angles on approximately 6 in. centers Operable blade: heavy gauge extruded 6063-T5 aluminum, 0.081 nominal wall thickness Seals.........Dual-durometer extruded vinyl blade seals Compressible stainless steel jamb seals Temperature Restrictions....(-20º F) - (+180ºF) Linkage.......Side linkage out of airstream (concealed in frame) Bearings......Synthetic sleeve type Axles.........½ in. dia. zinc plated steel Actuator......Invensys MA series, 2 positioned spring return Construction... Mechanically fastened Birdscreen.....3/4 in. x 0.051 in. flattened expanded aluminum in removable frame, inside mount (rear) Finish.........Mill Minimum Size..18 in. W x 24 in. H Maximum Single Section Size... 60 in. W or 96 in. H Options (at additional cost) A variety of bird and insect screens Extended sill Filter rack Flanged frame Hinged frame Security bars A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel paint Kynar paint *Width and height dimensions furnished approximately ¼ inch under size.

PERFORMANCE DATA Free Area Chart (Sq. ft.) Louver Height Inches Louver Width Inches 18 21 23 26 29 32 35 38 41 44 48 51 54 57 60 24 9 7 0.52 0.60 0.67 0.75 0.83 0.90 0.98 1.06 1.16 1.24 1.31 1.39 1.47 28 0.82 0.98 1.08 1.24 1.40 1.56 1.73 1.89 2.05 2.21 2.42 2.58 2.74 2.90 3.06 32 0.82 0.98 1.08 1.24 1.40 1.56 1.73 1.89 2.05 2.21 2.42 2.58 2.74 2.90 3.06 36 1.24 1.48 1.65 1.89 2.14 2.38 2.62 2.87 3.11 3.36 3.68 3.92 4.17 4.41 4.66 40 1.61 1.93 2.14 2.46 2.77 3.09 3.41 3.72 4.04 4.36 4.78 5.10 5.42 5.73 6.05 44 1.66 1.99 2.21 2.54 2.87 3.19 3.52 3.85 4.18 4.50 4.94 5.27 5.60 5.92 6.25 kpa 75 5 25 Air Leakage (with damper section closed) Test size 48 in. x 48 in. in. wg 2 1 0.9 0.8 48 2.09 2.50 2.77 3.19 3.60 4.01 4.42 4.83 5.24 5.65 6.20 6.61 7.02 7.43 7.84 75 0.7 52 2.09 2.50 2.77 3.19 3.60 4.01 4.42 4.83 5.24 5.65 6.20 6.61 7.02 7.43 7.84 56 2.51 3.01 3.34 3.83 4.33 4.82 5.32 5.81 6.31 6.80 7.46 7.95 8.45 8.94 9.44 60 2.94 3.52 3.90 4.48 5.06 5.64 6.21 6.79 7.37 7.95 8.72 9.30 9.88 15 11.03 Pressure 5 25 0.6 0.5 64 2.94 3.52 3.90 4.48 5.06 5.64 6.21 6.79 7.37 7.95 8.72 9.30 9.88 15 11.03 68 3.36 4.02 4.47 5.13 5.79 6.45 7.11 7.77 8.44 9.10 9.98 10.64 11.30 11.96 12.63 72 3.36 4.02 4.47 5.13 5.79 6.45 7.11 7.77 8.44 9.10 9.98 10.64 11.30 11.96 12.63 0.275 0.2 76 3.79 4.53 5.03 5.78 6.52 7.27 8.01 8.76 9.50 10.25 11.24 11.98 12.73 13.48 14.22 80 4.21 5.04 5.59 6.42 7.25 8.08 8.91 9.74 10.57 11.39 12.50 13.33 14.16 14.99 15.81 0.25 84 4.21 5.04 5.59 6.42 7.25 8.08 8.91 9.74 10.57 11.39 12.50 13.33 14.16 14.99 15.81 88 4.64 5.55 6.16 7.07 7.98 8.89 9.81 10.72 11.63 12.54 13.76 14.67 15.58 16.50 17.41 0.225 0.1 0.09 92 5.01 5.99 6.65 7.64 8.62 9.61 10.59 11.58 12.56 13.55 14.86 15.85 16.83 17.82 18.80 cfm/ft 2 1 2 3 4 5 6 7 8 9 10 96 5.06 6.06 6.72 7.72 8.71 9.71 10.70 11.70 12.70 13.69 15.02 16.02 17.01 18.01 19.00 cmh/m 2 20 30 40 50 60 70 80 90100 200 Leakage Airflow Resistance (Standard Air -.075 lb/ft 3 ) Water Penetration (Standard Air -.075 lb/ft 3 ) Static Pressure Drop Pa 200 100 90 80 70 60 50 40 30 20 10 9 8 7 6 5 in. wg 1 0.9 0.8 0.7 0.6 0.5 0.2 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 Test Size 48 in. x 48 in. Standard Air -.075 lb/ft 3 Exhaust ft/min: 200 300 400 500 600 700 800 900 1000 2000 3000 Model resistance to airflow (pressure drop) m/s: 2 3 4 5 6 7 8 9 10 varies depending on louver application (air intake or air exhaust). Free area velocities Free Air (shown) Velocityare higher than average velocity through the overall louver size. See louver selection information. Intake Test size 48 in. x 48 in. Test duration of 15 min. Water Penetration per Unit Free Area ml/m2 oz/ft2 0 80 60 40 20 0 0.25 0.20 0.15 0.10 0.05 0.00 Test Size 48 in. x 48 in. Test Period 15 minutes Standard Air -.075 lb/ft 3 ft/min: 900 950 1000 1050 1100 1150 1200 1250 1300 m/s: 4.5 5.5 6.0 Free Area Velocity The AMCA Water Penetration Test provides a method for comparing various louver models and designs as to their efficiency in resisting the penetration of rainfall under specific laboratory test conditions. The beginning point of water penetration is defined as that velocity where the water penetration curve projects through.01 oz. of water (penetration) per sq. ft. of louver free area. * The beginning point of water penetration for Model is 1020 fpm free area velocity. These perfor mance ratings do not guarantee a louver to be weather proof or stormproof and should be used in combination with other factors including good engineering judgement in selecting louvers.

INSTALLATION DETAILS Maximum Size and Installation Information The maximum single section size for the is 60 in. W or 96 in. H. Larger openings require field assembly of multiple louver panels to make up the overall opening size. Individual louver panels are designed to withstand a 25 PSF wind-load (please consult Greenheck if the louvers must withstand higher wind-loads). Structural reinforcing members may be required to adequately support and install multiple louver panels within a large opening. Structural reinforcing members along with any associated installation hardware is not provided by Greenheck unless indicated otherwise by Greenheck. Additional information on louver installation may be found in AMCA Publication #501, Louver Application Manual. Minimum Single Section Size 18 in. W x 21.25 in. H Maximum Single Section Size 60 in. W or 96 in. H

PRODUCT DETAILS

OPTION DRAWINGS FINISHES Finish Type Description/Application Color Selection Standard Warranty (Aluminum) 2-coat 70% Kynar 500 /Hylar 5000 AAMA 2605 Dry film thickness 1.2 mil. (AKA: Duranar, Fluoropon, Trinar, Flouropolymer, Polyvinylidene Fluoride, PVDF2) Best. The premier finish for extruded aluminum. Tough, long-lasting coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% Kynar 500 /Hylar 5000 or Baked Enamel. 10 Years (Consult Greenheck for availability of extended warranty) 2-coat 50% Kynar 500 /Hylar 5000 AAMA 2604 Dry film thickness 1.2 mil. (AKA: Acroflur, Acrynar ) Baked Enamel AAMA 2603 Dry film thickness 0.8 mil. (AKA: Acrabond Plus, Duracron ) Better. Tough, long-lasting coating has excellent color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Good. Provides good adhesion and resistance to weathering, corrosion and chemical stain. 2-Coat Mica: Greenheck offers 9 standard 2- coat Mica colors. Other colors are available. Consult Greenheck for possible extra cost when selecting non-standard colors or special finishes. 5 Years 1 Year Integral Color Anodize AA-M10C22A42 (>0.7 mil) Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil) Clear Anodize 204 R-1 AA-M10C22A31 (-0.7 mil) Industrial coatings Mill Two-step anodizing is produced by following the normal anodizing step with a second, colorfast process. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Light, Medium or Dark Bronze; Champagne; Black Clear Clear Greenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector. Consult a Greenheck Product Specialist for complete color and application information. Materials may be supplied in natural aluminum or galvanized steel finish when normal weathering is acceptable and there is no concern for color or color change. 5 years 5 years 1 Year Consult Greenheck Finishes meet or exceed AAMA 2605, AAMA 2604, and AAMA 2603 requirements. Please consult www.greenheck.com for complete information on standard and extended paint warranties. Paint finish warranties are not applicable to steel products. n/a March 2011 Rev. 3 Copyright 2011 Greenheck Fan Corporation Greenheck Fan Corporation reserves the right to make product changes without notice.