Kingspan Day-Lite Kapture Data Sheet

Similar documents
Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Upstand KS1000 DLU

Fabrications, Safety & Lighting Solutions. Product Data Sheet. Kingspan Day-Lite Trapezoidal Plus KS1000 DLTR PLUS 1.3 & 0.8

Insulated Roof & Wall Panels. Product Data Sheet. Lo-Pitch Insulated Roof Panel KS1000 LP

Insulated Roof & Wall Panels. Product Data Sheet. Curved Roof Insulated Panel KS1000 CR

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panel KS1000 RW

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal Insulated Wall Panel KS1000 RW

Domes Pyramids Opening Rooflights Flatglass Rooflights

QuadCore Controlled Environment Series Food Processing Datasheet

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Topdek Single Ply Insulated Roof Deck KS1000 TD

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)*

Product Data Sheet. UltraTemp Insulated Panels for Chilled Storage Applications with a Temperature Range of 0 C to +5 C KS1100 CS

Core. Thickness. Biological

KS1000TS Trapezoidal EcoSafe Insulated Tile Support Roof Panel

Kingspan Day-Lite Klick

ACM. Product Data Sheet

Product Data Sheet. QuadCore Karrier. Applications

VAULT ROOFLIGHT SYSTEM

ZINC. Product Data Sheet

Fabrications, Safety & Lighting Solutions

RS24-10 Single-Section Skylight System

How do you install yours?

BENCHMARK KREATE FAÇADE & ROOF SYSTEMS

Product Data Sheet. Product: Benchmark Wall Liner System

Cleanroom Systems UltraTech

RS32 Multi-Section Skylight System under/over seam clip double diverter

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

Flat Roofing. Brochure

Insulated Panel System. QuadCore IND. Superior FIRE Protection. Unrivalled THERMAL Efficiency. ENHANCED Environmental Credentials

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Page 1 of 5

Sound-absorbing and sound-insulating barriers

COMPOSITE PANEL ROOFLIGHTS - FAIRS

WESTECK WINDOWS and DOORS

Commercial Dynamic Dome Unit Skylight - Guide Specification

Insulated Panel Systems. 1, d0 IND E N 1350

Custom Daylighting Structures

VELUX America Inc. SPECIFICATION FOR MODEL FS NO LEAK FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

AKRAPLAST Sistemi S.p.A. - I Novate Milanese (Mi) - via Cascina del Sole, 70 Tel: (+39) Fax: (+39)

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

PRODUCT BROCHURE ARCHITECTURAL FABRICATIONS

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

PVC-U: Innovations and product ranges

KINGSPAN THERMAROOF TR21

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

BS 6206 KM BS EN KM 51961

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Controlled Environments. KS1100 CS Data Sheet. Controlled Environment Panels. Insulated Panels

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Cold Rooms Kide

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Roof System KS1000 X-dek. Product Data. Application. Dimensions & Weight. Product Tolerances. Available Lengths

SECTION METAL ROOF PANELS

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

upvc ENERGY EFFICIENT WINDOWS AND DOORS

A Guide To: Weatherseal selection & specification in Europe. Ensuring Superior performance

Insulating systems used in agricultural and industrial buildings

AIRCOOL VENTILATORS FURTHER INFORMATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

CI/Sf/B. (31) Ro5 (M5) April The width of single glazing. The warmth of double glazing. Pilkington Spacia Revolutionary vacuum glazing.

Roofgard Paving Support System

TUNNELS III.

1.1.2 All window frames will be Kite marked to indicate compliance with these standards.

FLAT ROOF SYSTEM PRODUCTS

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

MANUFACTURING TOLERANCES FOR PROFILED METAL ROOF AND WALL CLADDING

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

CHAPTER 3: Modern Methods of Construction (MMC)

External Coating Chart

CI/SfB (57.9) Xh4 Uniclass L7535 May VENTILATION LOUVRES ...

Model # 238HS-P8. 4/27/2011 Page 1 of 11

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

SECTION EXTERIOR GRILLS AND SCREENS

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!

CI/SfB (57.9) Xh4 Uniclass Pr_30_59_48 July 2017 VENTILATION LOUVRES...

Insulated Panels. CI/SfB. January CurveWall & Louvre. Architectural Wall Panel Systems. Approved to LPS 1181 Certificate No.

MGM Industries SIMULATION PERFORMANCE & SOLAR HEAT GAIN REPORT. Series 8010 Picture Window NCTL

HIGH-PERFORMANCE PRISMATIC DAYLIGHTING

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

KS SERIES - VERTICAL INSTALLATION

Brick Veneer Walls. Insulation

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

Corium Brick Rainscreen System Specifications

Vengen 28. There s a much bigger picture to be found at Ruskin Air Management. Double Glazed Thermal Break Louvre Window. naco.

Steelwork and Security Kiosks

VELUX America Inc. SPECIFICATION FOR MODEL VS and VSE NO LEAK VENTILATING SKYLIGHT SECTION UNIT SKYLIGHTS

Lexan* Thermopanel Sheet LTP30B4RS36. Property Profile Value Test Method. Lexan*

Double Brick Cavity Walls

Versatile & High Performance LED

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

DAYLIGHT PANELS A WIND AND WATERPROOF SYNTHETIC GLAZING SYSTEM

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

YES SSG TU Vent Window System

MODULAR ACOUSTIC FENCING INSTALLATION GUIDE

Transcription:

Light + Air UK & Republic of Ireland Kingspan Day-Lite Data Sheet KS700DLK, KS1400DLK, KS0DLK

2 Kingspan Day-Lite KS700DLK, KS1400DLK, KS0DLK Application KS700DLK, KS1400DLK, KS0DLK & KS2750DLK rooflights are suitable for use with all Kingspan insulated roof panels as well as other roof systems. Please refer to sales for further information. Frames include an integral condensation and drainage gutter which drain interior moisture to the outside 100% UV resistant 100% Diffusion The rooflight is triple-glazed using specially designed polycarbonate layers to maximize both light transmission and diffusion. The shape of the rooflight unit has been specially designed to capture the maximum level of light, even at low angles, so is ideal for use in geographical areas such as Northern Europe. The rooflight units are pre-glazed ready for installation in to the prefabricated kerbs. The U-value of the polycarbonate glazing is 2.2 W/m 2 K. The rooflight frames are fabricated from aluminium and have a natural mill finish. The corners of the frame and cap are mitred and welded. The safety security fabricated wire mesh has been tested to withstand the impact of a 50kg weight (400mm in diameter) dropped from a height of 2400mm (BS EN 1873:2014 Class SB1200*)and is Class B non-fragile to ACR[M]001. Through the utilization of nano-prismatic technology, Skylights offer exceptional levels of light transmission, coupled with 100% diffusion. Additionally, nano-prismatic technology eliminates glare and therefore hot spots, reducing heat gains in buildings. More light is directed to the work plane, providing the light levels required in any building for more hours than any other rooflight. With these features, Skylights will help comply with daylighting requirements, new European Daylighting Guidelines and BREEAM H01 Visual comfort requirements. * BS EN 1873:2014 Class SB900 for the security mesh for KS700DLK Dimensions and Weights Product Reference KERB O.D External Dimensions Daylight Opening Dimensions Skylight Area (m 2 ) Weight (kg) KS700DLK 780 780 810 810 692 692 0.4 12 KS1400DLK 780 1560 810 1590 692 1472 1.0 24 KS0DLK 1630 1560 1660 1590 1542 1472 2.2 44 KS2750DLK 2845 1560 2875 1590 2758 1472 4.0 62 Kerb Height Kerb Weight (kg) 19.2 27.8 29.0 41.7 39.5 57.0 54.5 78.7 Mesh Weight (kg) 0.9 1.9 4.2 7.6 Product Reference Diffusion SHGC (g-value) Light Transmittance (%)** Standard 100% 0.70 83 Climate Control 100% 0.45 81 Note: **Light transmission according to EN 410 is as measured on 600mm x 600mm samples

KS700DLK, KS1400DLK, KS0DLK Kingspan Day-Lite 3 Technical Specifications Kingspan Day-Lite Triple skin prismatic polycarbonate lens assembly Thermally broken aluminium Frame & aluminium cap Factory applied tape for sealing to kerb Low profile stainless fixing Factory applied weather sweep flipper gasket White polyester powder coated mesh Mesh clips to top of perimeter upstand Low profile stainless fixing to kerb through pre drilled hole in frame Kingspan Day-Lite Internal and external measurements. KS0DLK External 1660mm Daylight Opening 1542mm KS700DLK External 810mm Daylight Opening 692mm External 1590mm Daylight Opening 1472mm 1654x1584 External 810mm Daylight Opening 692mm 854x804

4 Kingspan Day-Lite KS700DLK, KS1400DLK, KS0DLK Installation Instructions Kingspan Day-Lite Internal and external measurements. KS2750DLK External 2875mm Daylight Opening 2758mm External 1590mm Daylight Opening 1472mm KS1400DLK External 1590mm Daylight Opening 1472mm 2870x804 External 810mm Daylight Opening 692mm Outer Dimension Daylight Opening

KS700DLK, KS1400DLK, KS0DLK Kingspan Day-Lite 5 H&S Classification Non-Fragility to ACR [M]001: 2014 Class B, when installed as per Kingspan details Non-Fragility to BS EN 1873:2014 Class SB1200 when installed as per Kingspan details The security mesh fixed to the kerb achieves Non-Fragility to ACR [M]001: 2014 Class B, when installed as per Kingspan details Non-Fragility to BS EN 1873:2014 Class SB1200 when installed as per Kingspan details** **Non-fragility to BS EN 1873:2014 Class SB900 for KS700DLK security mesh Fire Performance The Day-Lite polycarbonate achieves European class B-s1-d0 to EN13501, which can be regarded as an AA (National class) designation or BROOF(t4) (European class) in accordance with UK building regs. Properties Building air leakage: Less than 3m 3 /m 2 /hr at 50Pa for complete envelope*. Materials The Factory Assembled Skylight; Triple Layer Polycarbonate Aluminium Frame The Site Assembled kerb and safety screen (optional, but recommended); White Powder coated security safety screen manufactured from welded steel mesh White Powder coated galvanized kerb Product Tolerances Squareness +/-5mm +/-5mm +/-5mm Quality & Durability The Kingspan Day-Lite range is manufactured from the highest quality materials, using state-of-the-art production equipment to rigorous quality control standards; ensuring long term reliability and service life. All Kingspan Day-Lite products are fully compliant with ISO 9001, ISO 14001 and OHSAS/ISO 18001. Guarantee Kingspan Guarantee covering the structural and thermal performance for a period of up to 25 years. Safe Storage To ensure the Kingspan Day-Lite system remain in prime condition while stored on site, the following precautions should be taken. At ground level: Allocate a safe, trade-free area; Prevent personnel from walking over packs; and store all components of the Kingspan Day-Lite system in packaging and on a slight slope ensuring any penetrating rainwater drains off. At roof level: Prior to and during installation, securely tie Kingspan Day-Lite packs to the roof structure to prevent movement; and keep Kingspan Day-Lite skylights covered to prevent penetration from rainwater. Kingspan Day-Lite skylights must be kept out of direct sunlight at all times prior to installation (at both ground and roof level). It is recommended to cover Kingspan Day-Lite packs with a non-transparent waterproof sheet. Sea Freight Fully timber-crated packs are available on projects requiring delivery by sea freight shipping, at additional cost. Alternatively, steel containers can be used. Special loading charges apply. Delivery All deliveries (unless indicated otherwise) are by road transport to project site. Off-loading is the responsibility of the client. Fixing Details Please refer to the standard details for fixing arrangements. For further information, please contact Kingspan Technical Service. Packing Kingspan Day-Lite rooflights are stacked weather side up (to minimize pack height). The top, bottom, sides and ends are protected with foam and timber packing and the entire pack is wrapped in plastic.

UK Kingspan Light + Air Greenfield Business Park No.2 Holywell, Flintshire, CH8 7GJ T: +44 (0) 1352 716100 F: +44 (0) 1352 710161 E: info@kingspanlightandair.com www.kingspanlightandair.co.uk Ireland Kingspan Light + Air Carrickmacross Road, Kingscourt, Co. Cavan T: +353 (0) 420969 8500 F: +353 (0) 420969 8572 E: info@kingspanlightandair.com www.kingspanlightandair.ie For the product offering in other markets please contact your local sales representative or visit www.kingspanlightandair.com Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or description of, the end use or application of products or methods of working are for information only and Kingspan Limited and its subsidiaries accept no liability in respect thereof. Kingspan_Day-Lite Datasheet_UK_EN