Liquid-Flooded Ericsson Power Cycle

Similar documents
Performance Benefits for Organic Rankine Cycles with Flooded Expansion

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

Thermodynamic Comparison of Organic Rankine Cycles Employing Liquid-Flooded Expansion or a Solution Circuit

Fundamental Investigation Of Whole-Life Power Plant Performance For Enhanced Geothermal Systems

Chapter 8. Vapor Power Systems

a. The power required to drive the compressor; b. The inlet and output pipe cross-sectional area. [Ans: kw, m 2 ] [3.34, R. K.

Multi-Variable Optimisation Of Wet Vapour Organic Rankine Cycles With Twin-Screw Expanders

ME ENGINEERING THERMODYNAMICS UNIT III QUESTION BANK SVCET

Feedwater Heaters (FWH)

Lecture No.3. The Ideal Reheat Rankine Cycle


LECTURE-15. Ideal Reverse Brayton Cycle. Figure (6) Schematic of a closed reverse Brayton cycle

Chapter 6 THE SECOND LAW OF THERMODYNAMICS

Chapter Two. The Rankine cycle. Prepared by Dr. Shatha Ammourah

K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar , India

Consider a simple ideal Rankine cycle with fixed turbine inlet conditions. What is the effect of lowering the condenser pressure on

Available online at ScienceDirect. Energy Procedia 49 (2014 ) SolarPACES 2013

A Simplified Thermal Model for a CO2 Compressor

A Trans-critical CO2 Heat Pump System for Waste Heat Utilization in Warm Weather Condition Applied to a Milk Refrigeration Plant

Investigation of Separator Parameters in Kalina Cycle Systems

Conception of a Pulverized Coal Fired Power Plant with Carbon Capture around a Supercritical Carbon Dioxide Brayton Cycle

Performance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

OUTCOME 2 TUTORIAL 2 STEADY FLOW PLANT

High-Efficiency Thermodynamic Power Cycles for Concentrated Solar Power Systems

Application of an Integrally Geared Compander to an sco 2 Recompression Brayton Cycle

Pinch Analysis for Power Plant: A Novel Approach for Increase in Efficiency

Comparison of micro gas turbine heat recovery systems using ORC and trans-critical CO 2 cycle focusing on off-design performance

Efficiency improvement of steam power plants in Kuwait

Guidance page for practical work 15: modeling of the secondary circuit of a PWR

Revue des Energies Renouvelables Spécial ICT3-MENA Bou Ismail (2015) Numerical study of a single effect ejector-absorption cooling system

Exergy analysis of transcritical carbon dioxide refrigeration cycle with an expander

Modelling of CO 2 capture using Aspen Plus for EDF power plant, Krakow, Poland

Thermodynamic analysis on post combustion CO 2 capture of natural gas fired power plant

MULTI-OBJECTIVE OPTIMIZATION ON SUPERCRITICAL CO 2 RECOMPRESSION BRAYTON CYCLE USING KRIGING SURROGATE MODEL

UNCERTAINTY ON PERFORMANCE MEASUREMENT OF S-CO 2 COMPRESSOR OPERATING NEAR THE CRITICAL POINT

Energy. Transcritical or supercritical CO 2 cycles using both low- and high-temperature. heat sources. Y.M. Kim a, *, C.G. Kim a,d.favrat b.

Comparison of combined heat and power systems using an organic Rankine cycle and a low-temperature heat source

PERFORMANCE STUDY OF SOLAR THERMAL BINARY POWER CYCLES

Using Carbon Dioxide in a Transcritical Vapor Compression Refrigeration Cycle

ANALYSIS OF REFRIGERATION CYCLE PERFORMANCE WITH AN EJECTOR

CHAPTER 2 POWER PLANT THERMODYNAMICS

Kalex Kalina Cycle Power Systems For Use as a Bottoming Cycle for Combined Cycle Applications

Brayton Cycle. Introduction. Definitions. Reading Problems , 9-105, 9-131

B.Tech. Civil (Construction Management) / B.Tech. Civil (Water Resources Engineering) B.Tech. (Aerospace Engineering) Term-End Examination

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM IV (ME-41, 42,43 & 44)] QUIZ TEST-1 (Session: )

Supercritical Fluid Parameters in Organic Rankine Cycle Applications

Hydrogen oxygen steam generator integrating with renewable energy resource for electricity generation

Research on Ground Source Heat Pump Design

High-efficiency low LCOE combined cycles for sour gas oxy-combustion with CO[subscript 2] capture

Thermodynamic analysis of a regenerative gas turbine cogeneration plant

Energy Balances and Numerical Methods Design Project. Production of Methyl Tertiary-Butyl Ether

The Reduced Pumping Power Requirements from Increasing the Injection Well Fluid Density

CO 2. transcritical refrigeration cycles: potential for exploiting waste heat recovery with variable operating conditions

Michigan State University DEPARTMENT OF CHEMICAL ENGINEERING AND MATERIALS SCIENCE. ChE 321: Thermodynamics Spring 2017

Principles of Engineering Thermodynamics. 8th Edition SI Version

Modeling, Simulation and Optimization of Energy Systems using Aspen Plus. Giovanni Manente University of Padova

ORGANIC RANKINE CYCLE AS EFFICIENT ALTERNATIVE TO STEAM CYCLE FOR SMALL SCALE POWER GENERATION

Thermodynamics and Efficiency Analysis Toolbox 6 Sustainable Energy

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

Energy And Exergy Analysis Of Fully Condensing Steam Turbine At Various Steam Load Condition

Refrigeration Kylteknik

Investigations of N 2 O Transcritical Refrigeration Cycle Using Dedicated Mechanical Subcooling. Sanjeev Kumar 1 and Dr. D.K.

Power cycles. Principles of combustion cycles and efficient concepts

Review Questions for the FE Examination

Performance of a Combined Organic Rankine Cycle and Vapor Compression Cycle for Heat Activated Cooling

Technical and economical feasibility of the Rankine compression gas turbine (RCG)

Organic Rankine Cycle Configurations

Modified Reverse-Brayton Cycles for Efficient Liquefaction of Natural Gas

ABSTRACT. Christopher Somers, Masters of Science, Dr. Reinhard Radermacher, Mechanical Engineering

Fluid Mechanics, Heat Transfer, Fluid Mechanics Design Project. Production of Ethanol

CO2 Stirling Heat Pump for Residential Use

Analysis of Low Temperature Organic Rankine Cycles for Solar Applications

MCG THERMODYNAMICS II. 22 April 2008 Page 1 of 7 Prof. W. Hallett

Design and Optimization of Kalina Cycle for Geothermal Energy in Kenya

Secondary Loop System for Automotiv HVAC Units Under Different Climatic Conditions

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 08 Aug p-issn:

EFFECT OF AMBIENT TEMPERATURE, GAS TURBINE INLET TEMPERATURE AND COMPRESSOR PRESSURE RATIO ON PERFORMANCE OF COMBINED CYCLE POWER PLANT

Steady State And Transient Validation Of Heat Pumps Using Alternative Lower-GWP Refrigerants

Secondary Systems: Steam System

AN EXERGY COST ANALYSIS OF A COGENERATION PLANT

Installation of the Supercritical CO 2 Compressor Performance Test Loop as a First Phase of the SCIEL facility

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

MODELLING AND OPTIMIZATION OF POSSIBLE BOTTOMING UNITS FOR GENERAL SINGLE FLASH GEOTHERMAL POWER PLANTS

ENERGY RECOVERY IMPROVEMENT USING ORGANIC RANKINE CYCLE AT COVANTA S HAVERHILL FACILITY

THE CHOICE OF WORKING FLUID: (AND AN EFFICIENT TURBINE) Ennio Macchi Department of Energy - Politecnico di Milano

Refrigeration Cycle. Definitions , , 11-46, 11-49,

PERFORMANCE ANALYSIS OF ORGANIC RANKINE CYCLES USING DIFFERENT WORKING FLUIDS

AN ABSTRACT OF THE THESIS OF

AC : ENGINEERING THERMODYNAMICS - A GRAPHICAL APPROACH

Cool Producing Systems Based on Burning and Gasification of Biomass

Refrigeration Cycle With Two-Phase Condensing Ejector

Design of a Solar-Driven Ejector Cooling System

Fluid Mechanics, Heat Transfer, Thermodynamics Design Project. Production of Styrene

ISOBUTANE GEOTHERMAL BINARY CYCLE SENSITIVITY ANALYSIS

3. PROPOSALS OF SMALL SCALE BINARY GEOTHERMAL POWER PLANT WORKING IN THE POLISH LOWLAND CONDITIONS

Exergy Analysis of Absorption Power Cycle Depending on Source Temperatures

Performance of a Gas Turbine Power Plant

Combined cycle with detailed calculation of Cp in the HRSG

DEVELOPMENT OF TWIN PISTON EXPANDER WITH SOLENOID VALVE FOR ORGANIC RANKINE CYCLE

Transcription:

Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2014 Liquid-Flooded Ericsson Power Cycle Nelson A. James Purdue University, United States of America, najames@purdue.edu James E. Braun Purdue University, United States of America, jbraun@purdue.edu Eckhard A. Groll Purdue University, United States of America, groll@purdue.edu W. Travis Horton Purdue University, United States of America, wthorton@purdue.edu Follow this and additional works at: http://docs.lib.purdue.edu/icec James, Nelson A.; Braun, James E.; Groll, Eckhard A.; and Horton, W. Travis, "Liquid-Flooded Ericsson Power Cycle" (2014). International Compressor Engineering Conference. Paper 2296. http://docs.lib.purdue.edu/icec/2296 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

1272, Page 1 Liquid-Flooded Ericsson Power Cycle Nelson A. JAMES 1 *, James E. BRAUN 1, Eckhard A. Groll 1, and W. Travis HORTON 1 1 Purdue University, School of Mechanical Engineering, Ray W. Herrick Laboratories West Lafayette, IN, USA najames@purdue.edu, jbraun@purdue.edu, groll@purdue.edu, wthorton@purdue.edu * Corresponding Author ABSTRACT In this paper, the use of liquid flooding is examined to create a high efficiency Ericsson Power Cycle. The introduction of significant amounts of liquid into the compression and expansion processes of a gas leads to quasiisothermal behavior approximating that of an Ericsson cycle. A thermodynamic model is presented and various working fluid pairs are examined under operating conditions suitable for solar thermal power generation. The Liquid-Flooded Ericsson Cycle (LFEC) can be manufactured with fixed volume ratio machinery currently mass produced for the refrigeration industry. In this manner low cost, distributed solar thermal generation can be promoted. The thermodynamic performance of the LFEC is compared to that of other power cycles proposed for solar thermal systems. It is shown that for sufficiently high component efficiencies the Liquid-Flooded Ericsson Cycle provides higher thermal efficiencies than any other power cycle currently under consideration. 1. INTRODUCTION The Liquid-Flooded Ericsson Cycle (LFEC), as presented by Hugenroth (2006), is a practical implementation of an Ericsson cycle which can serve as a high efficiency power block for concentrated solar power (CSP) applications. The U.S. Department of Energy (2012) has identified the increase of conversion efficiencies in the power block of CSP plants as one of the many ways to drive down the cost of these renewable energy systems. The Ericsson Cycle is a gas cycle theoretically capable of achieving Carnot efficiencies. It consists of isothermal compression and expansion with isobaric regeneration. The LFEC utilizes liquid-flooding; which is the introduction of large quantities of liquid into the gaseous working fluid. The liquid serves as a thermal reservoir absorbing heat during compression and releasing heat during expansion. In this manner near isothermal behavior can be achieved. Typical turbo-machinery is susceptible to damage when liquid is entrained in the gas stream. Fortunately equipment utilized in the air conditioning and refrigeration industry has proven reliable when operating with liquid entrainment. Fixed volume machines, such as scroll and screw compressors, represent readily available devices that can be adapted for use in the LFEC. Through proper design they can be tailored for efficient operation with flooding (Bell et al. 2012). Results of thermodynamic modelling of the LFEC under conditions of interest to solar thermal power generation are presented in this paper. Models of competing power cycles are developed and their thermal efficiency compared to that of the LFEC. 2. CYCLE DESCRIPTION A schematic of the LFEC is shown in Figure 1. After mixing, cool liquid and gas are simultaneously compressed from state (1) to (2). During this process the liquid is slightly warmed due to absorbing the heat of compression. The gas and liquid are then separated with the gas heading to the regenerator at point (3) and the liquid heading to the cooler at point (9) to reject the heat of compression. The regenerator allows for thermal exchange between the high and low temperature sides of the cycle. The gas passing from points (3) to (4) is warmed as it absorbs heat from the

1272, Page 2 counterflowing stream returning to the cool side of the cycle from points (7) to (8). After passing through the regenerator the gas is then mixed with hot liquid and sent to the expander at state (5). During the expansion process the liquid slightly cools supplying heat to the gas, maintaining near isothermal conditions. After expansion the gas and liquid are separated, with the gas heading back to the regenerator at state (7) and the liquid heading to be pumped up to high pressure and reheated at state (12). A solar field can serve in the role of the heater and the high temperature separator can be enlarged for thermal storage allowing for natural integration of the LFEC into CSP systems. The LFEC can operate at relatively low pressures. Due to this the liquid which absorbs the heat of compression in the compressor can be easily pumped directly to a load to provide heating. In this manner the LFEC can readily function as a combined heating and power (CHP) system. Figure 1: Liquid-Flooded Ericsson Cycle schematic 3. CYCLE MODELLING A component based model of the LFEC was developed in order to better understand the performance of the cycle under conditions of interest to solar thermal power generation. The following assumptions were made in generating the model: Pressure drops in lines and heat exchangers are neglected Heat loss in lines are neglected Gas is non-condensable in liquid and separation is complete When mixed, liquid and gas are in thermo-mechanical equilibrium All rotating components are adiabatic Mixing and separation are adiabatic Thermodynamic properties at each point in the cycle were calculated utilizing a combination of equations of state included in Engineering Equation Solver (EES) (Klein 2012) and thermophysical property data. By specifying two independent properties each state could be defined. In sections of the cycle where liquid and gas are mixed, thermodynamic properties were determined using a mass weighting of both the liquid and gas properties each evaluated at the same temperature and pressure. Equation (1) is an example evaluation of the mixture enthalpy.

1272, Page 3 ( ( )) ( ( )) (1) 3.1 Component Models The heat transferred in the heater and cooler was determined by evaluating the enthalpy change across each component with the outlet fixed at the source or sink temperature. The regenerator was modelled using an effectiveness method. By specifying an effectiveness, Equation (2) was used to determine the heat transferred in the regenerator. ( ( ) ( )) ( ( ) ( )) (2) ( ) The work produced or consumed by rotating components was determined by defining an isentropic efficiency to determine the enthalpy change across each device relative to an isentropic process. This procedure is straightforward for single-phase devices, such as the pump and motor. For the flooded compressor and expander numerical iteration as shown in Hugenroth (2006) was used to determine the isentropic outlet state. 3.2 Fluid Selection A wide variety of gases could be chosen as the working fluid. The primary restriction on the choice of a gas was its ability to safely operate at elevated temperatures and not auto ignite. Similarly the liquid selection was also limited by high temperature compatibility. Of primary concern was the substance s ability to remain in the liquid state at elevated temperatures. To some degree this could be influenced by raising the system pressure above the liquid s vapor pressure. However, various liquids undergo thermal breakdown after prolonged exposure to high temperatures imposing a cap on feasible operation temperatures. Another concern when choosing a liquid is its ability to operate over the entire temperature range of the cycle. This means that in addition to not boiling at high temperatures, it must resist solidification at low temperatures. In theory, it would be possible to use two separate liquids in the LFEC, one suited for high temperatures on the expansion side and another capable of low temperature operation on the compression side. In practice, some fluid carryover may occur through the regenerator and solidify, leading to potential damage in the compressor and blockage of the heat exchangers. For this reason, it would be preferable to use a single liquid for both high and low temperature flooding. Table 1 shows a few potential flooding liquids and their applicable operation ranges. Table 1: Potential flooding liquid properties Liquid T min ( O C) T max ( O C) Vapor Pressure* (kpa) Therminol VP1 A 12 400 1320 B Na 22 K 78-2 785 0.13 Therminol 66 C 0 370 130 *evaluated at elevated temperatures A: Solutia Technical Bulletin 7239115C B: BASF C: Solutia Technical Bulletin 7239146D 4. LFEC MODEL RESULTS Utilizing the aforementioned model, performance trends for the LFEC were generated. Unless otherwise stated, the following operating parameters were imposed on the model. Heat rejection temperature of 43 O C 1 Low side pressure of 130 kpa 2 Regenerator effectiveness of 95% Component adiabatic efficiencies of 90%

1272, Page 4 Nitrogen as gaseous working fluid Therminol-66 as flooding liquid 1 chosen to allow for dry cooling in arid regions (U.S. Department of Energy 2011) 2 chosen to prevent boiling of flooding agent (Solutia Technical Bulletin 7239146D) Optimization routines available in EES were employed to maximize the cycle thermal efficiency at each operating condition. Three parameters were varied to perform the optimization. These were the compressor mass flow ratio y c, the expander mass flow ratio y e, and the system pressure ratio. The mass flow ratio was defined as the mass flow of liquid divided by the mass flow of gas for each side of the system. The pressure ratio was defined as the high side system pressure divided by the low side pressure. Nitrogen was chosen as the working fluid due to its being non-toxic, abundant, and environmentally benign. Figure 2 highlights the effect of working gas selection on the performance of the LFEC. For comparison, the plot on the left shows the efficiency of each gas in a Brayton cycle; which is essentially an LFEC without flooding. The plot on the right presents the thermal efficiency of the LFEC with optimized flooding ratios. Together these plots depict the relative improvements to cycle performance through introducing flooding. The degree of this improvement varies with source temperature going from around a 2% increase in thermal efficiency at 150 O C to a 7% increase at 350 O C. There is very little difference in the thermal efficiency of the LFEC when operating with Nitrogen, Helium, or Carbon Dioxide. However, the use of the refrigerant R134a results in a significant drop in the efficiency of the LFEC. When choosing a working gas, other criteria such as compatibility with the flooding liquid and equipment should be considered in addition to cycle efficiency. Figure 2: (Left) Thermal efficiency of regenerative Brayton cycle vs source temperature for various working fluids. (Right) Thermal efficiency of LFEC utilizing Therminol-66 vs source temperature for various working fluids. Therminol-66 was chosen as the flooding liquid due to the widespread use of similar thermal oils in CSP plants. In addition liquid flooding has been successfully demonstrated using oil in fixed volume machines (Hugenroth 2006). The effect of the flooding liquid selection on thermal efficiency is shown in Figure 3. From the plot it can be seen that Therminol-66 provides better conversion efficiencies than molten NaK salt and Therminol-VP1 at source temperatures below 350 O C. Greater efficiencies can be achieved by operating the LFEC at higher temperatures with liquids such as molten NaK salt, as shown in section 4. The analysis below was limited to 350 O C in order to investigate other properties, excluding operating temperature, which make for an ideal flooding agent. Figure 3 also shows the ratio of the pumping work divided by the expansion work as a function of temperature for each liquid. This value represents the relative losses associated with pumping the flooding liquid. One of the reasons for the superiority of Therminol-66 is that it has fewer losses associated with pumping. This is due in part to Therminol-66 having a larger heat capacitance than NaK as well as a lower vapor pressure than Therminol-VP1. A fluid with a larger specific heat will be able to absorb or release a greater amount of heat per unit mass. In this manner less fluid is required to be pumped in order to achieve the same isothermal effect. Hence less pumping work is required. In regards to the advantage over Therminol-VP1, the vapor pressure sets the minimum low side pressure in the system. Equation (3) depicts the pumping work for an incompressible liquid from pressure P 1 to P 2. By substituting the Pressure Ratio P r into the equation, it becomes evident that for a given pressure ratio the pumping work increases linearly with the low side pressure P 1.

1272, Page 5 Figure 3: LFEC thermal efficiency (left) and relative pumping losses (right) for various flooding liquids ( ) ( ) (3) ( ) The low side pressure has a detrimental influence on the thermal efficiency of the LFEC. However increases in system pressure can improve the power density of the system. The mass flow rate through fixed volume machines can be characterized by a suction volume, the fluid density and operation frequency of the device. This mass flow correlates to the work consumed or produced by the component as shown in equation (4) (4) For a fixed volume machine operating at a set speed, an increase in the system density will correspond to an increase in work consumed or produced. With density being proportional to pressure, this means an increase in system pressure leads to an increase in work. For a fixed volume expander and compressor of equal size, the expander will impose the limit on the power output of the LFEC. Due to lower densities at higher temperatures, a lower mass flow rate will pass through the expander than the compressor per revolution. With this in mind, Figure 4 depicts the net power output of the LFEC, as a function of expander suction volume operating at 60 Hz for multiple low side pressures. When designing a LFEC system for an application, a tradeoff must be made between higher conversion efficiencies and increased power density. Figure 4: The work output of the LFEC using Therminol-66 for various expander suction volumes and multiple low side pressures. The expander is operating at a speed of 60 Hz. In Figure 5, the thermal efficiency of the LFEC is plotted against the source temperature for various component efficiencies. The LFEC is extremely sensitive to the efficiency of the rotating components. This is due to the large back-work ratio typical of most gas power cycles. Great effort should be put into designing high efficiency devices compatible with flooding.

1272, Page 6 Figure 5: Thermal efficiency versus source temperature for multiple component efficiencies 4. COMPARISON TO ALTERNATIVE CYCLES 4.1 Alternative Cycles Descriptions Most CSP plants today utilize Rankine cycles for power blocks. Modelling of these cycles was performed in order to understand how the LFEC compares to the status quo. In addition modelling of supercritical CO 2 Brayton cycles was performed. These cycles have been identified as one of the most likely choices to replace Rankine cycles as the power block for CSP plants (U.S. Department of Energy 2012). As such a comparison of the LFEC to supercritical CO 2 cycles was necessary. The Rankine cycle is a vapor power cycle in which sub-cooled liquid is pressurized by a pump and sent to a boiler to be evaporated. The fluid is then sent through a turbine where work is extracted before being condensed and recycled. Some of the ways to improve the efficiency of these cycles is to utilize reheating and feed-water heating (Cengel and Boles 2008). Reheating is a where the expansion process first begins in a high pressure turbine and is interrupted. The fluid is reheated before continuing to be expanded in a low pressure turbine. Feed-water heating involves diverting some of the high temperature gas from the turbine to preheat the sub-cooled liquid being pumped. A diagram of a Rankine cycle with 1-stage reheat and feed-water heating is shown in figure 6.

1272, Page 7 Figure 6: A Rankine cycle with 1 stage reheat and an open feedwater heater. The ideal Brayton cycle is a gas cycles where gas is isentropically compressed and heated before isentropically expanding. Regeneration can be added between compression and expansion to improve cycle efficiency. The supercritical Brayton cycle differs from conventional Brayton cycles in that it operates in the working fluid s supercritical region. According to Dostál (2009), fluid property changes in the supercritical region reduce the compression work required, which allows for greater net-work output and higher thermal efficiencies. Challenges arise when performing regeneration in the supercritical region. Large changes in fluid properties can lead to pinching within the regenerator. Alternative system arrangements have been explored to overcome this shortcoming. One of the most promising arrangements is the recompression cycle depicted in Figure 7. In this configuration part of the flow is diverted and recompressed without cooling. The diverted flow is then inserted between two regeneration stages. Figure 7: Recompression Brayton cycle. Two regenerators and a recompression stage are used to improve overall regenerator effectiveness and cycle thermal efficiency. 4.2 Model Comparisons Component based models were developed for the Recompression Supercritical CO 2 Brayton Cycle and the Rankine cycle with reheat and feed-water heating. General parameters used in each model are shown in Table 2. Similar to the LFEC model, EES was used to optimize each system s thermal efficiency at each operating point. The parameters used in the optimization of the Rankine cycle included the overall pressure ratio, the intermediate pressure ratio where reheating and feed-water heating took place, as well as the mass fraction diverted to feed-water heating. For the S-CO2 cycle, the optimization was carried out by varying the system pressure ratio, high side pressure, and mass fraction split for recompression. The regenerator effectiveness was varied in order to maintain a pinch point of 5 O C or greater. Table 2: Model parameters for Recompression Brayton and Rankine Reheat with Feed-water heating models Parameter Rankine Brayton Working Fluid Water Carbon Dioxide Component efficiency 90% 90% Heat rejection Temperature 43 O C 43 O C Sub-cooling 5 O C -- Minimum Regenerator Pinch -- 5 O C Max System Pressure 300 Bar 300 Bar A comparison of the performance of LFEC to competing CSP cycles is shown in Figure 8. In this analysis NaK was utilized as the flooding liquid in the LFEC to allow for comparison at temperatures exceeding the range of most thermal oils. At source temperatures above 500 O C the LFEC provides greater overall cycle efficiencies than both the Rankine cycle with reheat and feedwater heating and the recompression supercritical CO 2 cycle.

1272, Page 8 Figure 8: Comparison of LFEC to other cycles of interest to CSP systems 4.3 Integration into CSP Systems The LFEC possesses other advantages over Rankine and supercritical CO 2 cycles in addition to improved thermal efficiency. One advantage is system simplicity. By directly utilizing the heat transfer fluid (HTF) heated by the solar radiation the LFEC removes the need for an intermediate heat exchanger between the power block and the HTF. The LFEC s high temperature separator can also be utilized for thermal storage. Another advantage of the LFEC is reduced system pressures. Though dependent on the flooding liquid selection and desired power density, the LFEC could feasibly operate below 10 bars. High efficiency Rankine and supercritical Brayton cycles can require pressures in excess of 200 bars. Lower pressures allow for thinner walled surfaces in the LFEC which should lead to increased heat transfer performance with the solar field. These lower pressures also allow the compressor flooding liquid to be pumped directly to a load making the LFEC readily suitable for CHP applications. The use of fixed volume machines opens up new possibilities for CSP plants utilizing the LFEC. These devices are currently mass produced for the air conditioning and refrigeration industries. By using these devices, high efficiency low cost packaged units can be developed, and a more distributed generation approach to CSP can be pursued. High temperature flooded operation is necessary for improved conversion efficiency of the LFEC. Screw machines have been tested under two phase conditions for geothermal energy recovery (Steidel et al. 1982). In addition scroll machines have been utilized in an Organic Rankine Cycle with liquid flooding (Woodland 2012). Though the temperatures in these applications fall short of those needed for CSP, they give credence to liquid flooding at elevated temperatures. 6. CONCLUSIONS The Liquid-Flooded Ericsson Cycle has been presented as a high efficiency power cycle for solar thermal power generation. The LFEC can provide competitive conversion efficiencies at a smaller scale than alternative cycles proposed for CSP applications. The thermal efficiency of the LFEC is extremely sensitive to the efficiency of the rotating equipment. Further work must be done to improve the performance of fixed volume machines under flooded conditions. Of particular interest is high temperature operation. Various demonstrations of flooded expansion have been performed; however they operate at temperatures below that needed for CSP applications. The development of devices able to efficiently perform flooded expansion at higher temperatures would make the LFEC an increasingly attractive alternative for CSP and intermediate temperature applications.

1272, Page 9 NOMENCLATURE h specific enthalpy (kj/kg) H enthalpy (kj) ṁ mass flow rate (kg/s) m mass (kg) heat flow rate (kw) ε effectiveness (-) W work (kw) P pressure (kpa) T Temperature ( O C) V Volume (m 3 ) ω frequency (Hz) v specific volume (m 3 /kg) ρ density (kg/m 3 ) Subscripts cool hot r regen min max gas fluid liquid cool stream hot stream ratio regenerator minimum maximum gaseous working flooding liquid REFERENCES BASF The Chemical Company, Product Safety Summary, Sodium Potassium Alloy, January 2011. Bell, I.H., Groll, E.A, Braun, J.E., King, G.B, Horton, W.T., 2012, Optimization of a Scroll Compressor for Liquid Flooding, International Journal of Refrigeration, 35:1901-1913 Cengel, Y., Boles, M., 2008, Thermodynamics: An Engineering Approach, McGraw Hill, New York, NY. Dostál, V., Kulhánek, M., 2009, Supercritical Carbon Dioxide Cycles Thermodynamic Analysis and Comparison, Student s Conference, Czech Technical University Hugenroth, J., 2006 Liquid Flooded Ericsson Cycle. Doctoral thesis, Purdue University. Klein, S, 2012, Engineering Equation Solver, F-Chart Software. Solutia, Therminol VP 1 Heat Transfer Fluid by Solutia, Technical Bulletin 7239115C Solutia, Therminol 66 Heat Transfer Fluid by Solutia, Technical Bulletin 7239146D Steidel, R.F., Weiss, H., Flower, J.E., 1982, Performance Characteristics of the Lysholm Engine as Tested for Geothermal Power Applications in the Imperial Valley, Journal of Engineering for Power, Vol.104: 231-240 U.S. Department of Energy, 2011, SunShot Concentrating Solar Power (CSP) R&D Funding Opportunity Announcement Number: DE-FOA-0000595 U.S. Department of Energy, 2012, Sunshot Vision Study Woodland, B., Groll, E.A, Braun, J.E., King, G.B, Horton, W.T., 2012, Performance Benefits of Organic Rankine Cycles with Liquid Flooded Expansion, International Refrigeration and Air Conditioning Conference, Purdue University ACKNOWLEDGEMENT The authors would like to acknowledge Brandon Woodland and Abhinav Krishna for their preliminary work on the investigation of the Liquid-flooded Ericsson Power Cycle.