MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

Similar documents
DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

SECTION ALUMINUM WINDOWS

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

HURON PUBLIC WORKS BUILDING HURON, SOUTH DAKOTA BID NO R

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Aluminum-Framed Entrances and Storefronts

STATE OF NEW HAMPSHIRE DEPARTMENT OF NATURAL AND CULTURAL RESOURCES DIVISION OF PARKS AND RECREATION SKI PATROL HUT PROJECT #: CAP 1804

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

TMS 114 XT TECHNICAL MANUAL

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

KNIGHT WALL SYSTEMS GUIDE DETAILS:

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

SWING DOOR SPECIFICATION

1.1.2 All window frames will be Kite marked to indicate compliance with these standards.

SECTION SECTIONAL OVERHEAD DOORS

TEST REPORT. Rendered to: ALL WEATHER ARCHITECTURAL ALUMINUM Vacaville, California. SERIES/MODEL: 6000 PRODUCT TYPE: Aluminum Awning Window

SECTION ALUMINUM STORM WINDOWS

SECTION HVAC GRAVITY VENTILATORS

SECTION LOUVERS AND VENTS

Division 08 OPENINGS TABLE OF CONTENTS

BEARING METAL STUD FRAMING

Stiles doors save lives. Stiles is a national leader in fire ratings and maintains a vast portfolio of options to the architect and builder.

KNIGHT WALL SYSTEMS GUIDE DETAILS:

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

CENTRIA FORMABOND II Metal Composite Wall System

JEFFERSON PARISH SHERIF S OFFICE

TMS 152 / 152T / 152XT TECHNICAL MANUAL

SECTION ALTERNATES

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

Senturion TM III Wall System

One and Two Family Additions

SPECIFICATION GUIDELINE

March 6, Subject: Addendum No. 2 Invitation for Bid No Toyota Park Transit Center Phase II. Ladies and Gentlemen:

Administrative Changes

SECTION UNIT MASONRY SYSTEM

DIVISION 8 DOORS & WINDOWS

C S I S E C T I O N STAINLESS STEEL DOORS AND FRAMES SPECIFICATIONS

Finestone Stucco System

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Specifications for FL-100 Soffit Panel

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

LEVEL TWO NUMBERS AND TITLES. Introductory Information. Bidding Requirements. Contracting Requirements. Facilities and Spaces. Systems and Assemblies

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

ALL-ALUMINUM DOOR & WINDOW FRAMING

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Designation: TTU NWI DIF Air Bladder Standard Scope

MID-RISE DESIGN & CONSTRUCTION

SECTION MASONRY ACCESSORIES

Finestone Stucco Ultra Wall System

Series 510-I Thermal Heavy Commercial Projected Window

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Inspection of New One- and Two- Family Dwellings

TEST REPORT. Report No.: B Rendered to: TREMCO, INCORPORATED Beachwood, Ohio

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Corium Brick Rainscreen System Specifications

NFPA 285 Compliant Wall Systems and Assemblies

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

SECTION ALUMINUM-FRAMED STOREFRONTS

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

City of Richmond Zoning Ordinance Page 12-1

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Riverbend Water Resources District Pump Station and Ground Storage Tanks Project Addendum No. 1 June 6, 2017


SECTION A. AAMA/NWWDA Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors.

Additions and Renovations to Saint Robert Bellarmine Parish Center and Narthex 9/16/14 Outline Design Development Specification

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

SECTION TURBINE VENTILATORS

SOLAR SHADING SYSTEMS - Manual Solar Shade SECTION ROLLER WINDOW SHADES

Series - 1

SECTION SPLIT FACE CONCRETE MASONRY UNITS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS

STUCCO FAILURES and REMEDIATION Roger G. Morse AIA

ELEVATION FOR DETAIL REFERENCE ONLY

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

Series Heavy Commercial Projected Window

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

Chapter 2 Understanding The Problem

16 Passaic Avenue, Unit 9 Fairfield, NJ Phone: (973) Fax: (973)

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

Comparison letter for MegaMet s MegaStorm Door against door construction details in FEMA 361 section 7.4.1

University Apartments on Brooklyn PROJECT MANUAL

ELEVATION FOR DETAIL REFERENCE ONLY

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

STRUCTURAL ABBREVIATIONS S-001 GENERAL NOTES CONCRETE MASONRY NOTES DESIGN NOTES SOF NSWG-10 UAS SUPPORT FACILITY FY 2016 MILCON P-225

Transcription:

ADDENDUM NUMBER FROM: MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 0 / 533 WEST MAIN STREET TUPELO, MS 3880 / 3880 FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON PHONE: -8-00 PROJECT: ACADEMIC STUDENT SERVICES BUILDING PROJECT #: GS #0-050/ ARCHITECT S #00 ADDENDUM DATE: MAY, 0 PLEASE BIND THIS ADDENDUM WITH YOUR SPECIFICATIONS ARCHITECTURAL ITEM NUMBER A REFERENCE: SPECIFICATION SECTION 083 HOLLOW METAL DOORS AND FRAMES ADD THE FOLLOWING AT PARAGRAPH..C. C. Severe Storm Shelter Openings: Provide complete door systems for hurricane or tornado storm shelters, and other areas of refuge, complying and tested according to FEMA 3, Third Edition (05), Design and Construction Guidance for Community Safe Rooms; and ICC 500 (008), ICC/NSSA Standard for the Design and Construction of Storm Shelters.. Each unit to bear third party permanent label indicating compliance with the referenced testing standards. ADD THE FOLLOWING AT PARAGRAPH.. HOLLOW METAL DOORS FOR SEVERE STORM SHELTERS C. General: Provide complete tornado or hurricane resistant door and frame shelter assemblies constructed to resist the design wind pressures for components and cladding and missile impact loads as described in ICC 500-008, ICC/NSSA Standard for the Design and Construction of Storm Shelters. Only single opening and paired opening doors and their frames constructed to resist calculated design wind pressures and laboratory tested missile impacts are acceptable.

ADDENDUM NUMBER. ICC ACADEMIC STUDENT SERVICES BUILDING GS #0-050 / ARCHITECT S #00 PAGE. Door systems, both single doors and paired openings, tested and complying with ICC 500 and FEMA 3 (008), Design and Construction Guidance for Community Safe Rooms and supported by third party test results.. Sheets fabricated on exterior openings from commercial quality hot dipped zinc coated steel complying with ASTM A A0. Gauges to be in accordance with manufacturers tested assemblies. 3. Vertical Edges: Vertical edges to have the face sheets joined by a continuous weld extending the full height of the door. Welds are to be ground, filled and dressed smooth. Beveled Lock Edge, /8 inch in inches.. Top Edge: Reinforce top of doors with a continuous steel channel extending the full width of the door and welded to the face sheet. Doors with an inverted top channel to include a steel closure channel, screw attached and welded in place with the web of the channel flush with the face sheets of the door. Plastic or composite channel fillers are not acceptable. 5. Hinge Reinforcement: Minimum gauge (3/") plate -/" x ". D. Manufacturers Basis of Design:. CECO Door Products StormPro Series.. Curries Company StormPro Series. ADD THE FOLLOWING AT PARAGRAPH..0 FRAMES FOR SEVERE STORM SHELTERS C. General: Subject to the same compliance standards and requirements as standard hollow metal frames, provide complete tornado or hurricane resistant door and frame assemblies, for both single doors and paired openings, tested and labeled as complying with ICC 500 and FEMA 3 and supported by third party test results.. Fabricate exterior frames from gauge hot dipped zinc coated steel that complying with ASTM designations A A0.. Manufacturers Basis of Design: a. CECO Door Products - StormPro Series. b. Curries Company - StormPro Series. ITEM NUMBER A REFERENCE: SPECIFICATION SECTION 083 ALUMINUM-FRAMED ENTRANCES AND STOREFRONT OMIT PARAGRAPHS.,., AND.3. ALUMINUM FRAMING IS EITHER CURTAINWALL AS DESCRIBED IN SECTION 083 OR

ADDENDUM NUMBER. ICC ACADEMIC STUDENT SERVICES BUILDING GS #0-050 / ARCHITECT S #00 PAGE 3 INTERIOR ALUMINUM FRAMING SYSTEM AS DESCRIBED IN PARAGRAPH. OF THIS SECTION. ITEM NUMBER A3 REFERENCE: SPECIFICATION SECTION 0800 DOOR HARDWARE A HARDWARE SCHEDULE, HARDWARE SET FOR DOOR 0C TO BE SET.0 IN LIEU OF SET.0. AT HARDWARE SCHEDULE, DOOR 3d, PREVIOUSLY NOT LISTED, TO HAVE HARDWARE SET 3.0. ITEM NUMBER A REFERENCE: SPECIFICATION SECTION 05 GROUND-SET FLAGPOLES REVISE PARAGRAPH..B. TO READ AS FOLLOWS:. Halyards and Cleats: One () each for each pole. ITEM NUMBER A5 REFERENCE: DRAWING SHEETS A00 THROUGH DOOR AND WINDOW DETAILS ALL EXTERIOR, VESTIBULE AND SAFE ROOM ALUMINUM FRAMING IS SHOWN AS ½ WIDE AND IS TO MEET REQUIREMENTS OF SPECIFICATION SECTION 083 GLAZED ALUMINUM CURTAIN WALL. ALL INTERIOR ALUMINUM FRAMING (EXCEPT AT VESTIBULES AND SAFE ROOM) IS SHOWN AS WIDE AND IS TO MEET REQUIREMENTS OF SPECIFICATION SECTION 083 ALUMINUM- FRAMED ENTRANCES AND STOREFRONT. ITEM NUMBER A REFERENCE: DRAWING SHEET A00 REVISED NAME OF FRAME TYPES - TO INTERIOR ALUMINUM FRAMING SYSTEM. ITEM NUMBER A REFERENCE: DRAWING SHEET REVISED WINDOW TYPE J TO -/ X -/ ALUMINUM FRAMING.

ADDENDUM NUMBER. ICC ACADEMIC STUDENT SERVICES BUILDING GS #0-050 / ARCHITECT S #00 PAGE ITEM NUMBER A8 REFERENCE: DRAWING SHEET ADDED NEW DETAIL 0 INTERIOR WINDOW HEAD. ITEM NUMBER A REFERENCE: DRAWING SHEET ADDED NEW DETAIL INTERIOR WINDOW JAMB ; REVISED DETAIL TO SHOW -/ X -/ ALUMINUM FRAMING. END OF ADDENDUM

MATERIAL KEYING DOOR SEE SCHED. 5 DOOR SEE SCHED. " OPENING SEE SCHED. OPENING - SEE SCHEDULE ' - " ' - 8" " " ' - 8" ' - 5" 8' - " ' - 5" MAILING ADDRESS: P.O. BOX 0 TUPELO, MS 3880 OFFICE ADDRESS: 533 WEST MAIN STREET TUPELO, MS 3880 PHONE: () 8-00 FAX: () 8-0500 3 5 FRAME: HOLLOW METAL RABETTED FRAME: HOLLOW METAL RABETTED FRAME: HOLLOW METAL NON-RABETTED FRAME: INTERIOR ALUMINUM FRAMING SYSTEM GLAZING TYPE = NOTE: DOOR MARK 3 DOES NOT HAVE SIDELITE FRAME: INTERIOR ALUMINUM FRAMING SYSTEM GLAZING TYPE = 3' - " 3' - " ' - " 3' - " ' - 0" 3' - 5 /8" 3' - 8 /8" ' - ' - / 5' - " ' - / ' - GL- CLEAR OPEN FOR STRUCTURAL PENETRATION ' - " / ' - 0" ' - " ' - 0" ' - 0" FRAME: INTERIOR ALUMINUM FRAMING SYSTEM GLAZING TYPE = ' - 8" FRAME: EXTERIOR ALUMINUM CURTAINWALL SYSTEM GLAZING TYPE = 5 ' - " / ' - 8 /" ' - " ' - / ' - 5 / " ' - 8" ' - " ' - / ' - / ' - 0" GL- FRAME: INTERIOR ALUMINUM FRAMING SYSTEM GLAZING TYPE = 3' - 0 /" 3' - 0 /" ' - " ' - / ' - / 3' - 0 /" " ' - 8" ' - 8" 3' - " 5' - 0 8 FRAME: EXTERIOR ALUMINUM STOREFRONT GLAZING TYPE = 8 FRAME: EXTERIOR ALUMINUM CURTAINWALL SYSTEM GLAZING TYPE = 5 3' - 0 /" 3' - 0 /" 8" CLEAR OPEN FOR STRUCTURAL PENETRATION 8" ' - / ' - " ' - " 3' - 0 /" ' - 8 /" ' - 8" ' - " ' - / ' - 5 / ' - 0" (EAST) ' - ' - " ' - " ' - / ' - 5 / ' - " ' - " ' - / ' - 5 / 3' - 0 3/8" FRAME: EXTERIOR ALUMINUM CURTAINWALL SYSTEM GLAZING TYPE = 5 3' - " ' - 3' - " FRAME: EXTERIOR ALUMINUM CURTAINWALL SYSTEM GLAZING TYPE = 5 (WEST) 3' - 0 3/8" ' - (WEST) (EAST) GL- GL-.. ADD ALTERNATES ADD ALTERNATE #: PROVIDE AND INSTALL NEW FOOD SERVICE EQUIPMENT AT GRILL 3 PER SPECIFICATION 000 (FOODSERVICE EQUIPMENT) AND EQUIPMENT LIST ON DRAWINGS. ALL ROUGH-INS AND RELOCATION AND INSTALLATION OF EXISTING FOOD SERVICE EQUIPMENT IS INCLUDED IN BASE BID. APPLIANCES OUTSIDE OF GRILL 3 ARE IN BASE BID. ADD ALTERNATE #: PROVIDE AND INSTALL CANOPY STRUCTURE AT SIDEWALKS AND TWO ENTRY PORCHES AT STUDENT SUPPORT BUILDING NORTH OF NEW BUILDING ON SITE PER DRAWINGS. COLUMNS AND ROOF AT TWO ENTRY PORCHES ARE INCLUDED IN THIS ALTERNATE. ALSO INCLUDED IN THIS ALTERNATE ARE LIGHT FIXTURES AND ASSOCIATED ELECTRICAL MATERIAL AT THESE CANOPIES PER ELECTRICAL SITE LIGHTING PLAN. SIDEWALK PAVING, STEPS, RAMPS, PORCH PAVING AND RAILING ARE IN BASE BID. ADD ALTERNATE #3: PROVIDE AND INSTALL STANDING-SEAM METAL ROOFING AND NON- VENTED NAILBASE INSULATION IN LIEU OF BASE BID ASPHALT SHINGLES AND VENTED NAILBASE INSULATION. ADD ALTERNATE #: ADD TWENTY-TWO () SPACE PARKING LOT WEST OF BUILDING SITE AND ASSOCIATED DRAINAGE AND LIGHTING AS SHOWN ON CIVIL AND ELECTRICAL DRAWINGS. ALSO INCLUDED IN THIS ALTERNATE IS MILLING, OVERLAY AND RESTRIPING OF EXISTING ASPHALT AS SHOWN CIVIL DRAWINGS. GENERAL NOTES ALL INTERIOR AND EXTERIOR DIMENSIONS ARE TO FACE OF STUD, CMU OR COLUMN CENTERLINE UNLESS NOTED OTHERWISE. PROVIDE COMPLETE FIRESTOP AT ALL STRUCTURAL, MECHANICAL AND ELECTRICAL PENETRATIONS THROUGH ALL FIRE RATED ASSEMBLIES. REFER TO SPECIFICATIONS FOR REQUIREMENTS. PROJECT TITLE ACADEMIC STUDENT SERVICES PROJECT NO: 000 DRAWN BY: BKS CHECKED BY: JPH DATE ISSUED: GS# 0-050 Itawamba C O M M U N I T Y C O L L E G E MARCH 0 REVISIONS & ADDENDUMS Addendum 05//0 3. INTERIOR DOOR FRAMES SHALL BE STANDARD WELDED HOLLOW METAL FRAMES UNLESS NOTED OTHERWISE.. ALL HOLLOW METAL DOOR FRAMES SHALL BE PAINTED. 5. PROVIDE SEALANT AT PERIMETER OF BOTH SIDES OF DOOR FRAME.. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.. 8. SEE ELECTRICAL DRAWINGS AND HARDWARE SCHEDULE FOR DOOR ACCESS CONTROL AND OPERATOR REQUIREMENTS. CONFIRM ALL WINDOW AND DOOR OPENING SIZES WITH MANUFACTURER. SHEET TITLE DOOR FRAME TYPES 5/5/0 3::58 PM /" = '-0" FRAME TYPES. CONTRACTOR TO ENSURE PROPER SEALING OF ALL PENETRATIONS MADE INTO OR THROUGH THE EXTERIOR CONTINUOUS BOARD INSULATION. ALL JOINTS OR PENETRATIONS MUST BE PROPERLY SEALED WITH JOINT SEAL FOAM TAPE OR COLD-FLUID APPLIED WATERPROOFING FLASHING. SHEET NUMBER A00 5 of Plot Date: BID DOCUMENTS - MARCH 0

MATERIAL KEYING 08 0 00.A0 STORMPROOF LOUVER W/INSECT SCREEN 3' - 8 /" 3' - 8 /" ' - 8 /" MAILING ADDRESS: P.O. BOX 0 TUPELO, MS 3880 OFFICE ADDRESS: 533 WEST MAIN STREET TUPELO, MS 3880 PHONE: () 8-00 FAX: () 8-0500 ' - 3/" ' - /" ' - / ' - " ' - " ' - / 3 ' - 8" ' - " ' - 8 /" ' - 8" ' - 8" ' - 8 /" ' - 8 /" 0' - 0" ' - 8 /" ' - 8 /" 3' - /" ' - 0" 3' - /" ' - 8 /" ' - 8 /" 3' - " ' - 0" 3' - " ' - 8" ' - 8" A B C D E F G ' - 3' - 3 /" 3' - 3 /" ' - 8 /" ' - 3/" ' - /" ' - / ' - 5 / /" = '-0" 5 H ' - 0" WINDOW TYPES ' - " ' - /" ' - / J 0 INTERIOR WINDOW GL-3 ' - /" " ' - 8" K INTERIOR WINDOW GL- " ' - 8" ' - 0" ' - 0" L INTERIOR WINDOW GL- 3' - " ' - 0" ' - 0" M INTERIOR TRANSACTION WINDOW GL- ' - ' - 8" ' - " N INTERIOR WINDOW GL- ADD ALTERNATES ADD ALTERNATE #: PROVIDE AND INSTALL NEW FOOD SERVICE EQUIPMENT AT GRILL 3 PER SPECIFICATION 000 (FOODSERVICE EQUIPMENT) AND EQUIPMENT LIST ON DRAWINGS. ALL ROUGH-INS AND RELOCATION AND INSTALLATION OF EXISTING FOOD SERVICE EQUIPMENT IS INCLUDED IN BASE BID. APPLIANCES OUTSIDE OF GRILL 3 ARE IN BASE BID. ADD ALTERNATE #: PROVIDE AND INSTALL CANOPY STRUCTURE AT SIDEWALKS AND TWO ENTRY PORCHES AT STUDENT SUPPORT BUILDING NORTH OF NEW BUILDING ON SITE PER DRAWINGS. COLUMNS AND ROOF AT TWO ENTRY PORCHES ARE INCLUDED IN THIS ALTERNATE. ALSO INCLUDED IN THIS ALTERNATE ARE LIGHT FIXTURES AND ASSOCIATED ELECTRICAL MATERIAL AT THESE CANOPIES PER ELECTRICAL SITE LIGHTING PLAN. SIDEWALK PAVING, STEPS, RAMPS, PORCH PAVING AND RAILING ARE IN BASE BID. ADD ALTERNATE #3: PROVIDE AND INSTALL STANDING-SEAM METAL ROOFING AND NON- VENTED NAILBASE INSULATION IN LIEU OF BASE BID ASPHALT SHINGLES AND VENTED NAILBASE INSULATION. ADD ALTERNATE #: ADD TWENTY-TWO () SPACE PARKING LOT WEST OF BUILDING SITE AND ASSOCIATED DRAINAGE AND LIGHTING AS SHOWN ON CIVIL AND ELECTRICAL DRAWINGS. ALSO INCLUDED IN THIS ALTERNATE IS MILLING, OVERLAY AND RESTRIPING OF EXISTING ASPHALT AS SHOWN CIVIL DRAWINGS. PROJECT TITLE ACADEMIC STUDENT SERVICES GS# 0-050 Itawamba C O M M U N I T Y C O L L E G E 0' - GENERAL NOTES PROJECT NO: 000 DRAWN BY: BKS ' - 0" 08 0 00.A0 " ' - 0 /8" 5' - /" 08 0 00.A0 " 08 0 00.A0 ' - 0" 08 0 00.A0 5' - 0".. 3.. 5.. ALL INTERIOR AND EXTERIOR DIMENSIONS ARE TO FACE OF STUD, CMU OR COLUMN CENTERLINE UNLESS NOTED OTHERWISE. PROVIDE COMPLETE FIRESTOP AT ALL STRUCTURAL, MECHANICAL AND ELECTRICAL PENETRATIONS THROUGH ALL FIRE RATED ASSEMBLIES. REFER TO SPECIFICATIONS FOR REQUIREMENTS. INTERIOR DOOR FRAMES SHALL BE STANDARD WELDED HOLLOW METAL FRAMES UNLESS NOTED OTHERWISE. ALL HOLLOW METAL DOOR FRAMES SHALL BE PAINTED. PROVIDE SEALANT AT PERIMETER OF BOTH SIDES OF DOOR FRAME. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED. CHECKED BY: JPH DATE ISSUED: MARCH 0 REVISIONS & ADDENDUMS Addendum 05//0 5/5/0 3:50:00 PM /" = '-0" LOUVER TYPES ' - /" NOTE: VERIFY ROUGH OPENINGS IN FIELD. COORDINATE WITH STEEL FRAMING AT OPENING AND WITH MECHANICAL PLENUM BEHIND LOUVER. ' - 0 3/8" 0' - 5" L- L- L-3 L-. 8.. SEE ELECTRICAL DRAWINGS AND HARDWARE SCHEDULE FOR DOOR ACCESS CONTROL AND OPERATOR REQUIREMENTS. CONFIRM ALL WINDOW AND DOOR OPENING SIZES WITH MANUFACTURER. CONTRACTOR TO ENSURE PROPER SEALING OF ALL PENETRATIONS MADE INTO OR THROUGH THE EXTERIOR CONTINUOUS BOARD INSULATION. ALL JOINTS OR PENETRATIONS MUST BE PROPERLY SEALED WITH JOINT SEAL FOAM TAPE OR COLD-FLUID APPLIED WATERPROOFING FLASHING. SHEET TITLE WINDOW TYPES & LOUVER TYPES SHEET NUMBER 5 5 of Plot Date: BID DOCUMENTS - MARCH 0

0 00.B0 R- BATT INSULATION 05 00.A0 0 00.F0 " BOARD INSULATION 0 0 00.M 0 00.C0 5/8" " " " 5 5/8" 3 / / 5/8" 3 5/8" 0 3.H0 0 00.P0 CAST STONE LINTEL 0.A0 05 50 00.B0 0 3.L0 MEMBRANE FLASHING W/ TERMINATION BAR 0 3.K0 WEEP 0 3.L05 STAINLESS STEEL DRIP (HEMMED) 0 00.D0 05 00.A0 0 00.F0 " BOARD INSULATION 0 00.B0 R- BATT INSULATION 0 0 00.M 0 00.C0 5/8" " " 3/8" 3 5/8" 3 / / 5/8" 0 3.H0 0 3.L0 MEMBRANE FLASHING W/ TERMINATION BAR 0.A0 0 3.A0 0 3.K0 WEEP 0 3.L05 STAINLESS STEEL DRIP 05 50 00.B0 0 00.D0 08 80 00.B0 (HEMMED) 0 00.F0 " BOARD INSULATION 0 00.B0 R- BATT INSULATION 0 0 00.M 05 00.A0 0 00.C0 5/8" " " 3/8" 3 5/8" " 5/8" 3 / / 5/8" 5/8" 0 3.A0 0 3.H0 0 3.L0 MEMBRANE FLASHING W/ TERMINATION BAR 0.A0 0 00.P0 CAST STONE LINTEL 0 3.L05 STAINLESS STEEL DRIP 05 50 00.B0 0 00.D0 08 80 00.B0 (HEMMED) MATERIAL KEYING 03 30 00.A03 CONCRETE SLAB SEE STRUCTURAL 03 30 00.A0 FOUNDATION SEE STRUCTURAL 0 3.A0 0 3.H0 0 3.K0 WEEP 0 3.L05 STAINLESS STEEL DRIP 0 3.L0 MEMBRANE FLASHING W/ TERMINATION BAR 0 00.A0 8" CONCRETE BLOCK SEE STRUCTURAL 0 00.P0 CAST STONE LINTEL 0 00.P03 CAST STONE SILL 05 00.A0 05 50 00.B0 0 0 00.M 0 0 00.M5 X 0.G0 SOLID POLYMER SURFACING WINDOW STOOL 0.A0 FLUID-APPLIED MEMBRANE FLASHING 0 00.B0 R- BATT INSULATION 0 00.F0 " BOARD INSULATION 0 00.C0 0 00.D0 08 3.C0 ALUMINUM SUBSILL 08 3.D0 ALUMINUM THRESHOLD SET IN SEALANT 08 3.E0 ALUMINUM SUBSILL FLASHING 08 80 00.B0 0.C0 METAL STUDS @ " O.C. 3 3.A0 CONCRETE PAVING - SEE CIVIL 3 3.J08 / PRE-MOLDED E.J. FILLER & SEALANT MAILING ADDRESS: P.O. BOX 0 TUPELO, MS 3880 OFFICE ADDRESS: 533 WEST MAIN STREET TUPELO, MS 3880 PHONE: () 8-00 FAX: () 8-0500 STOREFRONT HEAD WITH CAST STONE BAND STOREFRONT HEAD WITH BRICK 3 STOREFRONT HEAD WITH LINTEL 3 / / 5/8" 5/8" 5/8" 5/8" 3 / / 5/8" 0 00.F0 " BOARD INSULATION 05 00.A0 0 00.B0 R- BATT INSULATION 0 0 00.M 0 00.C0 5/8" " " 3/8" 3 5/8" 3 / / 5/8" 0 3.A0 0 3.H0 0 00.D0 08 80 00.B0 0 00.A0 0.C0 METAL STUDS @ " O.C. EQ / EQ /" FACE OF WALL BEYOND 08 80 00.B0 0 00.D0 08 3.E0 ALUMINUM SUBSILL FLASHING 3 3.J08 / PRE-MOLDED E.J. FILLER & SEALANT 03 30 00.A0 FOUNDATION SEE STRUCTURAL 3 3.A0 CONCRETE PAVING - SEE CIVIL 0.G0 SOLID POLYMER SURFACING WINDOW STOOL 0 0 00.M 0 00.B0 R- BATT INSULATION 05 00.A0 0 00.F0 " BOARD INSULATION 5/8" " " 3/8" 3 5/8" 5/8" 0 3.H0 0 3.A0 08 80 00.B0 08 3.C0 ALUMINUM SUBSILL 0 00.D0 0 00.P03 CAST STONE SILL 0.A0 ADD ALTERNATES ADD ALTERNATE #: PROVIDE AND INSTALL NEW FOOD SERVICE EQUIPMENT AT GRILL 3 PER SPECIFICATION 000 (FOODSERVICE EQUIPMENT) AND EQUIPMENT LIST ON DRAWINGS. ALL ROUGH-INS AND RELOCATION AND INSTALLATION OF EXISTING FOOD SERVICE EQUIPMENT IS INCLUDED IN BASE BID. APPLIANCES OUTSIDE OF GRILL 3 ARE IN BASE BID. ADD ALTERNATE #: PROVIDE AND INSTALL CANOPY STRUCTURE AT SIDEWALKS AND TWO ENTRY PORCHES AT STUDENT SUPPORT BUILDING NORTH OF NEW BUILDING ON SITE PER DRAWINGS. COLUMNS AND ROOF AT TWO ENTRY PORCHES ARE INCLUDED IN THIS ALTERNATE. ALSO INCLUDED IN THIS ALTERNATE ARE LIGHT FIXTURES AND ASSOCIATED ELECTRICAL MATERIAL AT THESE CANOPIES PER ELECTRICAL SITE LIGHTING PLAN. SIDEWALK PAVING, STEPS, RAMPS, PORCH PAVING AND RAILING ARE IN BASE BID. ADD ALTERNATE #3: PROVIDE AND INSTALL STANDING-SEAM METAL ROOFING AND NON- VENTED NAILBASE INSULATION IN LIEU OF BASE BID ASPHALT SHINGLES AND VENTED NAILBASE INSULATION. PROJECT TITLE ACADEMIC STUDENT SERVICES GS# 0-050 5//0 :0:53 AM STOREFRONT JAMB AT FIRST FLOOR 03 30 00.A03 CONCRETE SLAB SEE STRUCTURAL 05 00.A0 0 00.B0 R- BATT INSULATION 3 /8" 3/8" 5/8" 5/8" " " 3/8" 3 5/8" " STOREFRONT SILL AT CAST STONE BAND B 08 80 00.B0 0 00.D0 08 3.C0 ALUMINUM SUBSILL 0 00.D0 SECOND FLOOR FFE ' - 0" 0 0 00.M5 X 0 00.P03 CAST STONE SILL 0.A0 0 3.H0 0 00.F0 " BOARD INSULATION 0 INTERIOR WINDOW HEAD FLOOR FINISH AS SPECIFIED 3 / / 5/8" /" 8 ALUMINUM DOOR SILL AT FINISH FLOOR 5 STOREFRONT SILL AT FINISH FLOOR 08 3.D0 ALUMINUM THRESHOLD SET IN SEALANT 3 3.J08 / PRE-MOLDED E.J. FILLER & SEALANT 3 3.A0 CONCRETE PAVING - SEE CIVIL 03 30 00.A0 FOUNDATION SEE STRUCTURAL 3 3/8" / CAST STONE BASE BELOW 0 00.B0 R- BATT INSULATION 0 00.F0 " BOARD INSULATION 05 00.A0 0 3.A0 0.A0 0 00.D0 0 0 00.M5 X 0 00.C0 STOREFRONT SILL WITH CAST STONE 3/8" " EXTERIOR DOOR JAMB " 5/8" " 0" " " 3/8" 3 5/8" ADD ALTERNATE #: ADD TWENTY-TWO () SPACE PARKING LOT WEST OF BUILDING SITE AND ASSOCIATED DRAINAGE AND LIGHTING AS SHOWN ON CIVIL AND ELECTRICAL DRAWINGS. ALSO INCLUDED IN THIS ALTERNATE IS MILLING, OVERLAY AND RESTRIPING OF EXISTING ASPHALT AS SHOWN CIVIL DRAWINGS... 3.. 5... 8.. GENERAL NOTES ALL INTERIOR AND EXTERIOR DIMENSIONS ARE TO FACE OF STUD, CMU OR COLUMN CENTERLINE UNLESS NOTED OTHERWISE. PROVIDE COMPLETE FIRESTOP AT ALL STRUCTURAL, MECHANICAL AND ELECTRICAL PENETRATIONS THROUGH ALL FIRE RATED ASSEMBLIES. REFER TO SPECIFICATIONS FOR REQUIREMENTS. INTERIOR DOOR FRAMES SHALL BE STANDARD WELDED HOLLOW METAL FRAMES UNLESS NOTED OTHERWISE. ALL HOLLOW METAL DOOR FRAMES SHALL BE PAINTED. PROVIDE SEALANT AT PERIMETER OF BOTH SIDES OF DOOR FRAME. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED. SEE ELECTRICAL DRAWINGS AND HARDWARE SCHEDULE FOR DOOR ACCESS CONTROL AND OPERATOR REQUIREMENTS. CONFIRM ALL WINDOW AND DOOR OPENING SIZES WITH MANUFACTURER. CONTRACTOR TO ENSURE PROPER SEALING OF ALL PENETRATIONS MADE INTO OR THROUGH THE EXTERIOR CONTINUOUS BOARD INSULATION. ALL JOINTS OR PENETRATIONS MUST BE PROPERLY SEALED WITH JOINT SEAL FOAM TAPE OR COLD-FLUID APPLIED WATERPROOFING FLASHING. PROJECT NO: 000 DRAWN BY: BKS CHECKED BY: JPH DATE ISSUED: SHEET TITLE Itawamba C O M M U N I T Y C O L L E G E MARCH 0 REVISIONS & ADDENDUMS Addendum 05//0 DOOR & WINDOW DETAILS SHEET NUMBER 5 of Plot Date: BID DOCUMENTS - MARCH 0

0 00.F0 " BOARD INSULATION 0 00.A0 0 0 00.M 0 00.C0 5/8" 5/8" " 3/8" 3 5/8" " 5/8" 5/8" / 5/8" 5/8" 0 3.A0 0 3.H0 0 3.L0 MEMBRANE FLASHING W/ TERMINATION BAR 0.A0 0 00.P0 CAST STONE LINTEL 0 3.K0 WEEP 0 3.L05 STAINLESS STEEL DRIP (HEMMED) 05 50 00.B0 0 00.D0 08 80 00.B0 0 00.A0 0.C0 METAL STUDS @ " O.C. 5/8" 5/8" 5/8" EQ / EQ 0 00.A0 0.C0 METAL STUDS @ " O.C. 08 3.A0 HOLLOW METAL DOOR AND FRAME 0 3.Q03 FILL CAVITY W/500 PSI COARSE GROUT " 5/8" 5/8" 5/8" 8 3/" 0 00.C0 0 00.A0 0.C0 METAL STUDS @ " O.C. 5/8" 5/8" 5/8" 8 3/" 0 00.C0 08 3.A0 HOLLOW METAL DOOR AND FRAME 0 3.Q03 FILL CAVITY W/500 PSI COARSE GROUT MATERIAL KEYING 0 3.A0 0 3.H0 0 3.K0 WEEP 0 3.L05 STAINLESS STEEL DRIP 0 3.L0 MEMBRANE FLASHING W/ TERMINATION BAR 0 3.Q03 FILL CAVITY W/500 PSI COARSE GROUT 0 00.A0 8" CONCRETE BLOCK SEE STRUCTURAL 0 00.P0 CAST STONE LINTEL 05 00.A0 05 50 00.B0 0 0 00.M 0.G0 SOLID POLYMER SURFACING WINDOW STOOL 0.A0 FLUID-APPLIED MEMBRANE FLASHING 0 00.B0 R- BATT INSULATION 0 00.F0 " BOARD INSULATION 0 0.A0 EXTRUDED ALUMINUM PANEL 0 00.C0 0 00.D0 08 3.A0 HOLLOW METAL FRAME 08 3.A0 HOLLOW METAL DOOR AND FRAME 08.A0 SOLID CORE WOOD DOOR 08 3.B0 ALUMINUM DOOR 08 3.E0 ALUMINUM SUBSILL FLASHING 08 80 00.B0 08 0 00.A0 STORMPROOF LOUVER W/INSECT SCREEN 0.A0 METAL STUD FRAMING 0.C0 METAL STUDS @ " O.C. MAILING ADDRESS: P.O. BOX 0 TUPELO, MS 3880 OFFICE ADDRESS: 533 WEST MAIN STREET TUPELO, MS 3880 PHONE: () 8-00 FAX: () 8-0500 STOREFRONT HEAD WITH LINTEL INTERIOR WINDOW JAMB 3 INTERIOR DOOR HEAD 8 INTERIOR DOOR JAMB /8" /8" 0.A0 METAL STUD FRAMING /8" 0.A0 METAL STUD FRAMING /8" 0 00.F0 " BOARD INSULATION 0 00.B0 R- BATT INSULATION 0 0 00.M 05 00.A0 5 /8" 5/8" " " 3 / / 0.A0 METAL STUD FRAMING 08 3.A0 HOLLOW METAL FRAME INTERIOR CASED OPENING HEAD STOREFRONT HEAD / 5" 0.A0 0 0.A0 EXTRUDED ALUMINUM PANEL 3 5/8" 0 00.D0 05 00.A0 0 00.B0 R- BATT INSULATION 0 0 00.M 5 /8" 5 INTERIOR DOOR HEAD 5/8" " " 3/8" 3 5/8" 0 00.C0 08 0 00.A0 5" " 0 LOUVER HEAD WITH BRICK 08 3.A0 HOLLOW METAL FRAME 08.A0 SOLID CORE WOOD DOOR 0 3.H0 0 3.L0 MEMBRANE FLASHING W/ TERMINATION BAR 0.A0 0 3.A0 0 3.K0 WEEP 0 3.L05 STAINLESS STEEL DRIP (HEMMED) 05 50 00.B0 0 00.D0 0 00.F0 " BOARD INSULATION 0 00.B0 R- BATT INSULATION 0 0 00.M 05 00.A0 5 /8" INTERIOR DOOR JAMB 5/8" " " 3/8" 3 5/8" 0 00.C0 5" " LOUVER JAMB 08 3.A0 HOLLOW METAL FRAME 08.A0 SOLID CORE WOOD DOOR 0 3.A0 0 3.H0 0.A0 0 00.D0 08 0 00.A0 0 0 00.M 0 00.B0 R- BATT INSULATION 0 00.F0 " BOARD INSULATION 0.G0 SOLID POLYMER SURFACING WINDOW STOOL 05 00.A0 5 /8" 5" " 5/8" " " 3/8" 3 5/8" 5/8" 8 5/8" 3/8" 3 5/8" 0.A0 METAL STUD FRAMING 08 3.A0 HOLLOW METAL FRAME INTERIOR CASED OPENING JAMB LOUVER SILL 08 0 00.A0 0 00.D0 08 3.E0 ALUMINUM SUBSILL FLASHING 0.A0 0 3.A0 0 3.H0 ADD ALTERNATE #: PROVIDE AND INSTALL NEW FOOD SERVICE EQUIPMENT AT GRILL 3 PER SPECIFICATION 000 (FOODSERVICE EQUIPMENT) AND EQUIPMENT LIST ON DRAWINGS. ALL ROUGH-INS AND RELOCATION AND INSTALLATION OF EXISTING FOOD SERVICE EQUIPMENT IS INCLUDED IN BASE BID. APPLIANCES OUTSIDE OF GRILL 3 ARE IN BASE BID. ADD ALTERNATE #: PROVIDE AND INSTALL CANOPY STRUCTURE AT SIDEWALKS AND TWO ENTRY PORCHES AT STUDENT SUPPORT BUILDING NORTH OF NEW BUILDING ON SITE PER DRAWINGS. COLUMNS AND ROOF AT TWO ENTRY PORCHES ARE INCLUDED IN THIS ALTERNATE. ALSO INCLUDED IN THIS ALTERNATE ARE LIGHT FIXTURES AND ASSOCIATED ELECTRICAL MATERIAL AT THESE CANOPIES PER ELECTRICAL SITE LIGHTING PLAN. SIDEWALK PAVING, STEPS, RAMPS, PORCH PAVING AND RAILING ARE IN BASE BID. ADD ALTERNATE #3: PROVIDE AND INSTALL STANDING-SEAM METAL ROOFING AND NON- VENTED NAILBASE INSULATION IN LIEU OF BASE BID ASPHALT SHINGLES AND VENTED NAILBASE INSULATION. ADD ALTERNATE #: ADD TWENTY-TWO () SPACE PARKING LOT WEST OF BUILDING SITE AND ASSOCIATED DRAINAGE AND LIGHTING AS SHOWN ON CIVIL AND ELECTRICAL DRAWINGS. ALSO INCLUDED IN THIS ALTERNATE IS MILLING, OVERLAY AND RESTRIPING OF EXISTING ASPHALT AS SHOWN CIVIL DRAWINGS... ADD ALTERNATES GENERAL NOTES ALL INTERIOR AND EXTERIOR DIMENSIONS ARE TO FACE OF STUD, CMU OR COLUMN CENTERLINE UNLESS NOTED OTHERWISE. PROVIDE COMPLETE FIRESTOP AT ALL STRUCTURAL, MECHANICAL AND ELECTRICAL PENETRATIONS THROUGH ALL FIRE RATED ASSEMBLIES. REFER TO SPECIFICATIONS FOR REQUIREMENTS. PROJECT TITLE ACADEMIC STUDENT SERVICES PROJECT NO: 000 DRAWN BY: BKS CHECKED BY: JPH DATE ISSUED: GS# 0-050 Itawamba C O M M U N I T Y C O L L E G E MARCH 0 REVISIONS & ADDENDUMS Addendum 05//0 5//0 :0:53 AM 08 80 00.B0 08 3.B0 ALUMINUM DOOR 3 ALUMINUM DOOR HEAD WITH TRANSOM / STOREFRONT VERTICAL MULLION 08 80 00.B0 / 08 80 00.B0 5 STOREFRONT JAMB @ MULLION 0 00.A0 0 00.F0 " BOARD INSULATION 0 0 00.M 0.C0 METAL STUDS @ " O.C. 0 00.C0 5/8" / 5/8" STOREFRONT JAMB AT FIRST FLOOR 0 3.A0 0 3.H0 0.A0 0 00.D0 3.. 5... 8.. INTERIOR DOOR FRAMES SHALL BE STANDARD WELDED HOLLOW METAL FRAMES UNLESS NOTED OTHERWISE. ALL HOLLOW METAL DOOR FRAMES SHALL BE PAINTED. PROVIDE SEALANT AT PERIMETER OF BOTH SIDES OF DOOR FRAME. ALL WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED. SEE ELECTRICAL DRAWINGS AND HARDWARE SCHEDULE FOR DOOR ACCESS CONTROL AND OPERATOR REQUIREMENTS. CONFIRM ALL WINDOW AND DOOR OPENING SIZES WITH MANUFACTURER. CONTRACTOR TO ENSURE PROPER SEALING OF ALL PENETRATIONS MADE INTO OR THROUGH THE EXTERIOR CONTINUOUS BOARD INSULATION. ALL JOINTS OR PENETRATIONS MUST BE PROPERLY SEALED WITH JOINT SEAL FOAM TAPE OR COLD-FLUID APPLIED WATERPROOFING FLASHING. SHEET TITLE DOOR & WINDOW DETAILS SHEET NUMBER 5 of Plot Date: BID DOCUMENTS - MARCH 0