Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

Similar documents
Agilent Sample Preparation Portfolio ACCURATE, REPRODUCIBLE RESULTS RIGHT FROM THE START

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Application Note: Multi-Residue Pesticides in Fruit and Vegetables (9/16/08)

Application Note. Abstract. Authors. Introduction. Environmental

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

Extraction and Analysis of Neonicotinoid Pesticides using QuEChERS Approach

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Method Translation in Liquid Chromatography

Tyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

On-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

B r i n g i n g e x p e r t s t o g e t h e r TELOS neo Polymeric Solid Phase Extraction Columns Simple and Effective SPE

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Development of Analysis Methods for Therapeutic Monoclonal Antibodies Using Innovative Superficially Porous Particle Biocolumns

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

MassPREP On-Line Desalting Cartridge

EtG / EtS Analysis UCT INNOVATION THROUGH CHEMISTRY FORENSICS

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

MultiQuant Software Version 3.0

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

ENHANCED MS WITH THE TURN OF A KEY

RAM Direct Injection. (Restricted Access Media) A Tool for the Separation of Small Molecules in the Presence of Large Biomolecules

Empore. Solid Phase Extraction Cartridges. Technical Information. Product Description. Product Characteristics. Sorbents Available

Agilent solutions for contract research and manufacturing organizations

Validation Report 19

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

BÜCHI Labortechnik AG

Agilent 6430 Triple Quadrupole LC/MS System

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Thermo Scientific TSQ Quantum Access MAX

Development of a Fast and Cost-Effective Multi-Residue Method to Determine Pesticides in Tobacco by LC/MS/MS

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Quantitation of cyanotoxins in drinking water according to EPA 544 guidelines

Converting a Liquid-Liquid Extraction Method for Vitamin D to a 96-Well Plate Supported Liquid Extraction Format

[ product solution ] Waters Oasis µ Elution PlateS. Patented Innovation. Elution volume as low as 25 μl. No evaporation and reconstitution

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

Application Note. Authors. Abstract

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

A Sub-picogram Quantification Method for Desmopressin in Plasma using the SCIEX Triple Quad 6500 System

Guide to Trap Cartridge Care and Use

CHROMATOGRAPHY/MASS SPECTROMETRY

- DisQuE Dispersive Sample Preparation

Accucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

The clearly better choice

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

Protein-Pak Hi Res HIC Column and HIC Protein Standard

AppNote 5/2006 ABSTRACT

Sample Prep - Solid Phase Extraction

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

Investigation of Solid Phase Microextraction as an Alternative to Dried Blood Spot

Genotoxicity is the property of a compound

Dynamic High Capacity Mustang Q Membrane Units for Scaleable Anion Exchange Chromatography Purification of Adenoviral Vectors

SFC Säulen für analytische und preparative Anwendungen

Peptide Mapping: A Quality by Design (QbD) Approach

Clarity BioSolutions For Synthetic DNA/RNA Advance Your. Oligonucleotide Work. From Sample Preparation to Analysis and Purification

Method Development Considerations for Reversed-Phase Protein Separations

mabs and ADCs analysis by RP

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Using HRAM Survey Analysis Combined with Rapid MS2 Data to Develop a Fragmentation Based Detection Workflow for Structure ID Acquisition

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

G Sep Size Exclusion Columns

New Contaminants Are Always Emerging. High-Throughput Methods for Testing Serum and Drinking Water

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

Zwitterion Chromatography ZIC

Fast Preparative Column Liquid Chromatography (PCLC)

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

New Core-Shell Technology

SMART Digest Kit User Manual. Version 2

Instructions for Capillary Electrophoresis Peptide Analysis Kit

Fundamentals and Techniques of Preparative HPLC. Parto Zist Behboud Tel: 42108

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

TurboMass GC/MS Software

Olga Shimelis, Katherine Stenerson, Michael Ye, Carmen T. Santasania, and Ed Mauney. Supelco, Div. of Sigma-Aldrich, Bellefonte, PA USA

HepG2 Labeling and Cell Growth Protocol for IROA Phenotypic Metabolic Profiling

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

Bivalirudin Purification:

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

Ion Exchange Chromatography. Learning Objectives:

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

Sepax Technologies, Inc.

Combining High Temperature and Small Particles: The Advantages of Zirconia

Preparative HPLC is still the

Transcription:

Puzzled About LCMS? Sensitivity in Mass Spec Analysis Sample Prep Adapting LC-UV Optimizing and Maintaining Your Mass Spec To LCMS Paul Altiero Alex Ucci Applications Phone Support Chemistry and Supplies Division November 2017

Sensitivity in Mass Spec Analysis Signal to Noise Signal to Noise Solvent Composition and Drying Effects analytical sensitivity. The concentration at which the mean response is statistically beyond the noise limits of the signal at zero concentration. Analytical sensitivity is the ability of a test to detect a target analyte - medical-dictionary.thefreedictionary.com/analytical+sensitivity 2 Confidentiality Label October 30, 2017

Sensitivity in Mass Spec Analysis 2 Analytes at the Same Concentration 3 Confidentiality Label October 30, 2017

Sensitivity in Mass Spec Analysis Does the higher response mean better sensitivity? S/N >21,000 S/N < 7600 4 Confidentiality Label October 30, 2017

Sensitivity in Mass Spec Analysis Solvent Composition and Drying Effects Signal to Noise Ion Evaporation Model Solvent Composition and Drying Effects Evaporation Rayleigh Limit Coulomb Explosion Analyte Ion Is ejected from the surface of the droplet due to field strength at the surface 5 Confidentiality Label October 30, 2017

Sensitivity in Mass Spec Analysis Solvent Composition and Drying Effects Signal to Noise Solvent Composition and Drying Effects 6 Confidentiality Label October 30, 2017

Sensitivity in Mass Spec Analysis Solvent Composition and Drying Effects Signal to Noise Solvent Composition and Drying Effects 7 Confidentiality Label October 30, 2017

Sensitivity in Mass Spec Analysis Solvent Composition and Drying Effects Signal to Noise Solvent Composition and Drying Effects Agilent ZORBAX RRHD Eclipse Plus C18 2.1 x 100 mm, 1.8 µm Mobile phase: 10% B Pressure: 480 bar S/N M6G = 37.5 Agilent ZORBAX RRHD HILIC Plus 2.1 x 100 mm, 1.8 µm Mobile phase: 70% B S/N M6G = 143.9 Pressure: 350 bar 8 Confidentiality Label October 30, 2017

Why Perform Sample Clean-Up? To acquire desired sensitivity/selectivity To reduce contamination/carryover issues Use of sensitive and expensive instruments: Protect your investment!!! Pesticides in Avocado without SP Pesticides in Avocado with SP

Ion Suppression: What Can Dirty Samples Do? Interference type Typical Elution Conditions (C18 column) Short term effect (single injection) Long term effect (multiple injections) Likely long term causes Salt/Polar ionics Proteins/ Peptides Lyso-phosphatidylcholines At or near void with < 20% 10 s of column volumes 10 s of column volumes at 70% - organic at 40% - 70% organic 90% organic Significant ion-suppression Significant ion- Significant ion-suppression suppression Unknown Unknown Decreased sensitivity, Increased variability Ion source contamination Ion source contamination Ion source contamination, Some column build-up Lipids and other hydrophobics 10 s to 100 s of column volumes at > 90% organic Some ion suppression, however, usually retained on LC column) Decreased sensitivity, Increased variability Ion source contamination, Column build-up Need to remove salts, proteins/peptides, and lipids!

Tandem Mass Spectrometry and The Case of the Disappearing Matrix Selected ion monitoring looking at 100 fg HCB in matrix MRM s better selectivity makes the matrix disappear

Instrument Contamination Salt build-up in LC-MS ion source from unextracted salts ESI Ion Source contamination after 3000x Urine Dilute/Shoot Injections Curtain plate after injection of 25 samples with extractions from raisins without cleanup 12

Sample Preparation Techniques for Today s Discussion Solid Phase Extraction (SPE) Multi-step approach for highest level of sample cleanup QuEChERS (dspe) Sample cleanup by extraction of bulk interferences Captiva EMR-Lipids (PPT and lipid removal) Removes precipitated proteins by in-well protein precipitation and also removes lipids Cleanliness Selectivity Complexity Cost Filtration Simple and fast removal of particulates

Functionalized Filtration: Captiva EMR-Lipid Captiva EMR-Lipid: effective lipid and protein removal 99% lipid removal Available in 96-well plate, 1 ml, 3 and 6 ml cartridge formats Pass-through/clean-up format Solvent retention frit in 96-well plate and 1mL cartridge formats allows for in-well or in-cartridge protein precipitation 3 and 6mL cartridge formats do not contain solvent retention frit, which allows for gravity elution High analyte recovery One step sample addition and activation (20% water is needed to achieve optimum lipid removal) 20% water provided in 3:1-5:1 crash solution for protein precipitation workflow Key Application Notes 5991-8006EN 5991-8007EN Efficiency of Biological Fluid Matrix Removal using Agilent Captiva EMR-Lipid Cleanup 5991-8006EN Quantitative LC/MS/MS Analysis of Drugs in Human Serum with Agilent Captiva EMR-Lipid Cleanup 5991-7956EN Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR-Lipid 5991-7956EN

Enhanced Matrix Removal: EMR-Lipid When activated by water - The materials selective hydrophobic interactions increase. - Suspension of particles with high surface area. - Rapidly interacts with straight chain, lipid-like functional groups. - Does not retain analytes Triglycerides Free Fatty Acids Phospholipids EMR-Lipid Mechanism Combined size exclusion and hydrophobic interaction.

QuEChERS Screening of pesticide residues in fruit and vegetables Developed to make sample cleanup of food faster, simpler, less expensive, and greener Now used with other matrices and compound classes as well QuEChERS: Quick Easy Cheap Effective Rugged Safe Commercially available kits allow for ease of use and convenience leading to increased throughput Consists of two steps, and thus 2 kits: Step 1: Liquid Extraction Step 2: Dispersive SPE / Interference Removal

Agilent Dispersive Kits Dispersive kit contains: Centrifuge tubes containing pre-weighed SPE sorbents such as: C18: removes residual proteins and lipids PSA: primary/secondary amine for removal of organic acids and sugars GCB: graphitized carbon black, removes pigments EMR-Lipid: selectively removes fats/lipids Kits available for different food types For both AOAC (US) method and EN (Europe) QUECHERS is a non-selective technique, does not remove ALL the matrix, but just enough SPE sorbent also available as bulk material

AFTER Clean-up BEFORE Clean-Up Used All Food Types clean-up kit for red chili powder 5982-0029 400 mg PSA 400 mg C18 45 mg GCB Determination of Multi-Pesticide Residues in Red Chili Powder using QUECHERS and the Agilent 7000 Series Triple Quadrupole GC/MS System (5991-4193EN) http://www.agilent.com/cs/library/applications/5991-4193en.pdf

What is Solid Phase Extraction? Interference 1 Uses a plastic disposable cartridge packed with varying amounts of sorbent between two frits Sorbent can be silica/polymeric based and involve a variety of phases chosen based on the chemistry of the analyte of interest and interferences Uses of SPE: removal of interferences, concentration/enrichment, desalting, solvent exchange Typical SPE Sequence Frits Interference 2 Analyte SPE Sorbent Step 1: Condition the cartridge Step 2: Apply sample Step 3: First wash of the cartridge (interference removal) Step 4: Apply solvent to elute

Why Choose SPE? Flexible - match a broad spectrum of sample and target compound types to different sorbents and forms Wide array of formats and sorbents for lower detection limits and longer instrument uptime from cleaner extracts Agilent has over 40 sorbent materials/phases available! Increase sample throughput with automation-friendly formats Easy adoption of methods due to high number of publications and applications Get the right answer the first time with highest accuracy and confidence Best balance of sample cleanliness, accuracy of results, and costper-sample

Processing 96-Well Plates and Cartridges Positive Pressure Manifolds

Productivity Benefits with Sample Preparation More Matrix Removal = Less Matrix Entering System = Time and Cost Savings! Less matrix build-up Less interferences Improved S/N Better reproducibility Better chromatography Less time spent on data analysis/manual integration Less time spent on re-runs/recalibrations Less maintenance Less instrument down-time Saves $$ on consumables/services Less troubleshooting Is it my column or my MS? Less instrument down-time

Optimizing and Maintaining Your Mass Spec Matrix, Modifiers and Suppression Matrix, Modifiers and Suppression Instrument settings and data collection 25 Interference type Salt/Polar ionics Proteins/ Peptides Lyso-phosphatidylcholines Lipids and other Confidentiality Label October 30, 2017

Optimizing and Maintaining Your Mass Spec x102 Matrix, Modifiers and Suppression Instrument settings and data collection A: Acid in H 2 O B: CH 3 CN 0.729 ml/min Time 0.00 1.43 2.86 %B 10 15 27 40 o C Agilent Poroshell 120 SB-C18, 2.1 x 100 mm, 2.7 µm Source: 350 o C, 10 L/min, 50 psi, -3500 V Acquisition: SIM Neg (169, 305, 193**, 289, 457, 441), **caffeine is not detected in Neg mode 0.75 0.5 0.25 0 Matrix, Modifiers and Suppression 1 1 1 x102 1 1 1 0.75 0.5 0.25 0 x102 1 1 1 0.75 0.5 0.25 0 x102 1 1 1 0.75 0.5 0.25 0 0.2% Acetic Acid 0.2% Formic Acid 0.02% Trifluoroacetic Acid 10mM Ammonium Acetate ph 3.6 S/N GCG = 686 S/N GCG = 636 S/N GCG = 344 S/N GCG = 80 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 3.3 3.4 3.5 Counts (%) vs. Acquisition Time (min) 26 Confidentiality Label October 30, 2017

Optimizing and Maintaining Your Mass Spec Data Collection Matrix, Modifiers and Suppression Instrument settings and data collection 6 x10 6 x10 x10 6 6 x10 6 x10 1 ms MS SIM Dwell Time 1 1 1 10 ms MS SIM Dwell Time 1 1 1 25 ms MS SIM Dwell Time 1 1 1 50 ms MS SIM Dwell Time 1 1 1 75 ms MS SIM Dwell Time 1 1 1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 S/N GCG = 571 n C = 47 S/N GCG = 678 n C = 45 S/N GCG = 2562 n C = 38 S/N GCG = 807 n C = 28 S/N GCG = 642 n C = 21 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 27 Confidentiality Label October 30, 2017

Optimizing and Maintaining Your LCMS Checking instrument settings and performance Matrix, Modifiers and Suppression Instrument settings and data collection Inject a known standard and check response ideally v. SQC chart Run a blank zero volume injection Run check tune and compare to previous tunes 28 Confidentiality Label October 30, 2017

Adapting LC-UV To LCMS Changing column size Injection Volumes Flowrates Trading chromatographic resolution for speed Changing Column Size Smaller columns reduce solvent Require smaller injection volumes Keep linear velocity constant by reducing flowrate Column ID Column Volume Typical Injection Typical Inj Range Typical Flowrate 4.6 mm 1500μl 15μl 5-50μl 1 ml/min 3.0 mm 600μl 5μl 3-30μl 400 μl/min 2.1 mm 300μl 2μl 0.5-10μl 200 μl/min 1.0 mm 70μl 0.5μl 0.1-2.5μl 50 μl/min 29 Confidentiality Label October 30, 2017

Adapting LC-UV To LCMS Changing Column Size Keep injection volumes small and organic composition of sample at or below starting gradient conditions Changing column size Injection Volumes Flowrates Trading chromatographic resolution for speed Sample in Mobile Phase Sample in Stronger Solvent 30 Confidentiality Label October 30, 2017

Adapting LC-UV To LCMS Trading Chromatographic Resolution for Speed Changing column size Injection Volumes Flowrates Trading chromatographic resolution for speed 31 Confidentiality Label October 30, 2017

Adapting LC-UV To LCMS Trading Chromatographic Resolution for Speed Changing column size Injection Volumes Flowrates Trading chromatographic resolution for speed 32 Confidentiality Label October 30, 2017

Piecing it all together Sensitivity in Mass Spec Analysis Sample Prep Optimizing and Maintaining Your Mass Spec Adapting LC-UV To LCMS

Contact Agilent Chemistries and Supplies Technical Support 1-800-227-9770 Option 3, Option 3: Option 1 for GC/GCMS Columns and Supplies Option 2 for LC/LCMS Columns and Supplies Option 3 for Sample Preparation, Filtration and QuEChERS Option 4 for Spectroscopy Supplies Available in the USA & Canada 8-5 all time zones gc-column-support@agilent.com lc-column-support@agilent.com spp-support@agilent.com spectro-supplies-support@agilent.com

Questions? 35 Confidentiality Label October 30, 2017