CHANGES TO THE US ENERGY CODES COMMERCIAL & RESIDENTIAL

Similar documents
Code Compliance with Insulated Concrete Form Foundations

Slab edge insulation is one of

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.

Module number 6 provides an on-line, self-paced training seminar on energy efficiency and energy conservation for residential buildings.

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

MID-RISE DESIGN & CONSTRUCTION

Recommended Amendments to the 2012 International Residential Code (IRC)

BUILDING IN A WARM CLIMATE? CHILL. With Logix XtraComfort, It s All Safe and Sound. Your home, your family and all your prized possessions

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

2

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

2012 IECC Residential with State Adopted Changes

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

California Building Envelope Solutions

Use of Structural Insulated Panels (SIPs) in Seismic Design Categories

Michigan Energy Code Training and Implementation Program

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

R-Value. Effective. Energy efficiency of masonry s thermal mass is recognized by code 9" 2" R21 + R18 THERMAL MASS +13 R13 R18

Boulder City NV Prepared by (Print Name) Signature Date

Michigan Energy Code Training and Implementation Program

Energy Efficiency, Continuous Insulation and Outsulation Systems

NFPA 285 Compliant Wall Systems and Assemblies

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

En e r g y Ef f i c i e n c y, Co n t i n u o u s In s u l at i o n a n d Ou t s u l at i o n Sy s t e m s

ICFs. Insulating Concrete Forms. Shorten Construction Schedule Enhance Comfort and Safety Reduce Energy Costs

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Ontario s Building Code

Code Requirements For Residential Windows & Doors

1. When using the REScheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Inspection of New One- and Two- Family Dwellings

Continuous Insulation Systems for Exterior Walls

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

How to Meet Code and Manage Moisture in an Environment of Increasing Air Tightness Requirements. Ted Winslow

Armourwall Stucco Systems

Airspace R-Values. Educational Overview. Revised 12/6/2016

Insulating Basements: Part 1 Fundamentals

November 10, 2015 Baltimore, MD. presented by

Hurricane- Resistance. designations: WHY FORTIFIED? DESIGNATION PROCESS

REPORT HOLDER: JOHNS MANVILLE TH STREET DENVER, COLORADO EVALUATION SUBJECT:

Thermal Bridging in Residential Construction

Want to build a more energy-efficient home?

2013 COMMERCIAL PRODUCTS

Residential Design with Structural Insulated Panels

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

Fiscal Note for 2018 NC Energy Conservation Code and Energy Provisions of 2018 NC Residential Code

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Advantage ICF System Product Information Bulletin

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

Single Family Residence Building Permits

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 6

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

Beginning of the Course

2012 IECC Cost Effectiveness Analysis

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

Code Compliance with Insulated Concrete Form Foundations

Perhaps you ve never worried about what s underneath your shingles and siding.

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

SPECIFICATION GUIDE. thin glazed brick

Oregon High Performance Home Requirements

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: AMVIC INCORPORATED

Closed-Cell Spray Foam Insulation. Performance in Residential and Commercial Buildings During Adverse Weather

Hardin County Planning and Development Commission

Montana Homebuilder Brief: Residential Energy Code 1

Wood-Frame wall Assemblies

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

Integrated Air & Water Barrier Systems

HPW Protocol Reference Manual

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

Sealing the Envelope with SPF Insulation

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

CommercialComplete WALL SYSTEMS. Visit Division7.owensCorning.com to view our new Division 7 thermal & moisture protection ebook!

Background Basement Thermal Behavior

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

2015 IECC Whole Building Air Leakage Compliance

Energy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES

Transcription:

Many changes have been made to the new energy code requirements. Among them the demand for better building envelope designs that require more airtight structures with a continuous air barrier, and greater thermal insulation values. The new energy code prescriptive requirements are a natural fit for buildings constructed with LOGIX. However, other wall systems, such as CMU and framed walls, are looking at more labor and material costs, to meet the new air leakage and greater insulation requirements. This document summarizes the new energy code requirements related to wall systems, in particular thermal insulation and air leakage requirements in Chapter 11 and 13 of the 2012 International Residential Code (IRC) and International Building Code (IBC), respectively. 2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) Chapter 4 in the Commercial and Residential Provisions of the 2012 IECC form the basis for the energy efficiency requirements found in the 2012 IBC and IRC, respectively. Recently released in mid-2011, the major changes in the 2012 IECC centers on creating buildings that use 30% less energy than that required by the 2006 IECC edition. 1 of 6

CHANGES TO ENERGY EFFICIENCY REQUIREMENTS - RESIDENTIAL (Chapter 11, 2012 IRC) The energy efficiency requirements for residential buildings are covered under Chapter 11 of the 2012 IRC. Higher Insulation Values The following table lists the prescriptive minimum insulation values from Chapter 11 for mass walls, wood-framed, and basement walls 1. The insulation requirements have increased from previous editions, in particular for framed walls. Climate Zones Mass Walls Above-grade, *, ** (ICFs) Wood-framed Walls Above-grade, **, *** Basements & Crawl Spaces, **, *** 1 3/4 13cav 0 2 4/6 3 8/13 20cav OR 13cav + 5ci 4 Except Marine 5ci OR 13cav 10ci OR 13cav 5 & Marine 4 13/17 15ci OR 19cav 6 15/20 20cav + 5ci OR 13cav + 10ci 7 & 8 19/21 * The second insulation value is required when more than half the insulation is located in the interior side of the wall. ** s are for the insulation material only. *** cav = cavitiy insulation, ci = continuous insulation. The EPS form panels of LOGIX PRO forms provide an insulation value of R-23 2, which exceeds the requirements in all Climate Zones in both above-grade and basement walls. Framed walls in Climate Zones 3 to 8, however, will require either more cavity insulation, or a combination of cavity and continuous insulation, for both above-grade and basement walls. The amount of additional insulation could be as much as adding 1 to 3 inches of rigid foam sheathing. 2 of 6

In the warmer Climate Zones the amount of required insulation may not be significant. However, designers, home owners and builders, should consider the strength and durability that LOGIX provides for buildings in Climate Zones 1 and 2. Climate Zones 1 and 2 are in areas where hurricanes typically occur. LOGIX can provide structures built to with stand extreme wind conditions, and wind-borne debris, more efficiently than masonry and framed construction. For more information see Technical Bulletin 31, Disaster Resistance: LOGIX in Hurricane & Tornado Prone Regions. This technical bulletin also offers high wind load reinforcement tables and a complete drawing set for the construction of FEMA approved Safe Rooms. ACH (air changes per hour) is a measure of the volume of air that is replaced every hour in a defined space at a given air pressure. The lower the ACH the more airtight the building. Air Leakage Requirements Blower Door tests are required to determine air leakage rates. The new air leakage rates are noted below 3. Zones 1 & 2 <= 5 ACH at 50 kpa Zones 3 to 8 <= 3 ACH at 50 kpa Typically testing at less than 1 ACH at 50 kpa, buildings constructed with LOGIX for the exterior walls will have no trouble meeting the air leakage requirements. However, framed walls will require more sealing measures to meet the air leakage requirements in Climate Zones 3 to 8. 3 of 6

CHANGES TO ENERGY EFFICIENCY REQUIREMENTS - COMMERCIAL (Chapter 13, 2012 IBC) The energy efficiency requirements for commercial buildings are covered under Chapter 13 of the 2012 IBC, which refers to the Commercial Provisions of the 2012 IECC. Higher Insulation Values Above-grade The following table lists the prescriptive minimum insulation values for above-grade walls from the Commercial Provisions of the 2012 IECC 4. The insulation requirements have increased from previous editions, in particular for metal and wood framed walls. Climate Zones Mass Walls Abovegrade *, **, (ICFs) Metal Framed Abovegrade *, **, Metal Building Abovegrade *, **, Wood Framed & Other *, **, 1 5.7ci 13cav + 5ci 13cav + 6.5ci 13cav + 3.8ci OR 20cav 2 7.6ci 13cav + 7.5ci 3 9.5ci 4 Except Marine 5 & Marine 4 11.4ci 13.3ci 6 15.2ci 7 13cav + 15.6ci 8 25ci 13cav + 19.5ci 13cav + 13ci 13cav + 19.5ci * s are for the insulation material only. ** cav = cavitiy insulation, ci = continuous insulation. 13cav + 7.5ci OR 20cav + 3.8ci 13cav + 15.6ci OR 20cav + 10ci 4 of 6

To compare the prescriptive requirements against LOGIX s, a table showing the s of vairous LOGIX wall assemblies have been prepared. The table can be found on page 6 of Technical Bulletin 30, Total of LOGIX Wall Assemblies. The EPS form panels of LOGIX PRO forms provides an insulation value of R-23 2, which exceeds the requirements in Climate Zones 1 to 7. For Climate Zone 8 LOGIX Platinum form panels, which provides R-26 5, exceeds the minimum R-25 insulation requirement. Metal and wood framed walls, however, will require either more cavity insulation, or a combination of cavity and continuous insulation, to meet the minimum insulation values in all Climate Zones. Higher Insulation Values Below-grade For below-grade, greater insulation values are required compared to previous editions of the energy code for commercial buildings 4. Climate Zones Below-grade Walls 1 NR * 2 NR * 3 NR * 4 to 6 7.5ci 7 10ci 8 12.5ci *NR = Not required LOGIX PRO forms can easily meet the requirements for belowgrade walls in all Climate Zones. Metal and wood framed walls will require an additional layer of continuous insulation ranging from R-7.5 to R-12.5 depending on the Climate Zone. 5 of 6

A complete list of total s for LOGIX form products is available in Section 8.5 of the LOGIX Design Manual. Air Leakage Requirements Unlike the air leakage requirements for residential buildings, Blower Door tests are not required for cast-in-place concrete walls since they are considered air barriers. Therefore, LOGIX, which acts as a continuous air barrier, is exempt from Blower Door test requirements. However, framed walls will require the Blower Door test. Walls built with masonry will have to be fully grouted or painted in order to be considered an air barrier, and exempt from the Blower Door test. Creating more energy efficient buildings is the primary focus of new building and energy codes. As a result, proper design of the exterior walls of a building play an important role in complying with the new energy requirements. By providing airtight structures with a continuous air barrier, and continuous insulation with high s, LOGIX already meets the anticipated new energy requirements. On-theother-hand, framed structures will become more expensive to build with, requiring more labor and material costs, in order to meet the new energy requirements. For further information contact your local LOGIX representative or e-mail info@logixicf.com. Related Articles: 1. Technical Bulletin 23, Thermal Performance: The ICF Effect 2. Technical Bulletin 27, Changes to the Canadian Building Codes 3. Technical Bulletin 28, Changes to the US Building Codes 2012 4. Technical Bulletin 30, Total of LOGIX Wall Assemblies 5. Technical Bulletin 32, Changes to Canadian Energy Codes 2012 - Commercial & Residential 1. See 2012 IRC, Table 1102.1.1 6. Technical Bulletin 34, Ontario Energy Codes 2012 - Commercial & 2. Intertek Test Report 3048347 3. See 2012 IRC, N1102.4.1.2 Residential 4. See 2012 IECC, Table C402.2 5. Intertek Test Report, Thermal Resistance of LOGIX ICF Wall System Project #100050754COQ-001. 6 of 6