Fine Dust Sensor FDS 15. OUT ma

Similar documents
FIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.

Biomass Boiler Emission Abatement Technologies. Simon Wakefield

Chemical composition and source apportionment of PM 1.0, PM 2.5 and PM in the roadside environment of Hong Kong

Greschbachstrasse 3b, Kahlsruhe Germany

Low-cost air pollution sensors for environmental and occupational health

HEAT RECUPERATION IN VENTILATION SYSTEM OF BASEMENT LABORATORY

GOTHENBURG ENERGY. Workshop London

Near reference sensors and their application. February 13 th, 2017 Hannamari Jaakkola, Vaisala Oyj

TECHNICAL DATA SHEET

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

ASD. Extraction and Filtration Technology for Dust and Smoke. Extraction. Filtration. Persistence.

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

Air Quality issues in Sri Lanka. R.N.R.Jayaratne Assistant Director Air, Noise, Vibration Monitoring Unit CENTRAL ENVIRONMENTAL AUTHORITY

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

Reducing diesel particulate emissions in highly-impacted locations

MEP Engineer's Letter of Assurance

Air quality in stations

UBA builds answers Positive energy building in Dessau

Indicator Fact Sheet Signals 2001 Air Pollution

GRIMM Aerosol Technik Grimm Instrumentation The future of particle measurement Ing. Wolfgang Brunnhuber Environmental Division Manager

LEZA Low Emission Zone in Amsterdam: Implementation and evaluation of effects on air quality by long-term monitoring

HAQT- Helsinki AQ Testbed Ari Karppinen; Athens 6/2017

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

STANDARDIZED FILTER TESTS OF METAL WORKING FLUID MIST SEPARATORS

Do European standards for indoor air quality take into account outdoor air quality? Professor Bjarne W. Olesen, PhD, Department of Civil Engineering

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

STANDARDIZED FILTER TESTS OF METAL WORKING FLUID MIST SEPARATORS

WBEA Standard Operating Procedure

49 instead of 9 Filter Classes The Air Filter Standard ISO in an Overview.

Altivar AC Drives. Advanced energy management and performance in motor control. altivardrives.com

Smarter Choices, Better Air.

B C Separator ad Bed E precipitator

Controlling Emissions and Saving Money with Highly Engineered Cartridge Filter Technology

Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Advanced Instrumentation for Improved Plant Operation

Air Quality Monitoring at Dublin Airport: Annual Report for HSSE Department

EUROVENT 4/11 ENERGY EFFICIENCY CLASSIFICATION OF AIR FILTERS FOR GENERAL VENTILATION PURPOSES

Wireless Outdoor Lighting Control System

Product and Service Catalog

A Home Use Study of Residential HVAC Filters

Indoor Air Quality Improvement in a School Building in Delhi

Preliminary Field Evaluation of EPA Method CTM-039 (PM2.5 Stack Sampling Method) Michael D. Buser and Derek P. Whitelock

JONIX MATE NON THERMAL PLASMA TECHNOLOGY

MEP's Letter of Assurance

2008 Beltwide Cotton Conferences, Nashville, Tennessee, January 8-11, 2008

Leadership in Filtration. ScandMist Industrial air cleaners

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

AIR HYGIENE TEST SUITABLE FOR ALLERGIC PEOPLE

THE COLLEGE OF WILLIAM & MARY MA STER PLA N

Rittal after sales service for industrial applications. A service tailored to your needs

AIR QUALITY MANAGEMENT at URBAN REGIONAL and GLOBAL SCALES 4 International and IUAPPA Regional Conference,10-13 September 2012 Istanbul-Turkey

OPTIMIZED DESIGN FOR HEAVY MOUND VENTURI

Application for Renewal Industrial Wastewater Discharge Permit

MEAN ANNUAL EXPOSURE OF CHILDREN AGED 0-4 YEARS TO ATMOSPHERIC PARTICULATE POLLUTION

MEP's Letter of Assurance

DISPLACEMENT VENTILATION

Compact flue gas analyser: testo 300 M-I

Initial Sand Mine and Processing Plant Particulate Levels. Crispin Pierce PhD University of Wisconsin-Eau Claire 20 January 2013

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Indoor Air Quality Plan

: Industrial Boiler MACT: CEM Requirements. Dan Kietzer: SICK Process Automation

Vetsmarttubes Cooling Tubes. Agricultural Product for Light and Air

Mon Tue Wed Thur Fri Sat

Fine particle measuring system

Apr 6 Thu 4:00 PM Deadline for submission of approved paper invoices and payment request forms to Payment Services.

EXPERIENCE OF SOURCE APPORTIONMENT STUDY IN INDIA

US Aero Services, Inc. Employment Application Form

REGULATION 6 PARTICULATE MATTER AND VISIBLE EMISSIONS RULE 3 WOOD-BURNING DEVICES INDEX

MD Accelerated Switching RM54

Some Engineering Countermeasures to Reduce Exposure to Welding Fumes and Gases Avoiding Occurrence of Blow Holes in Welded Material

Ambient Air Monitoring Systems

AIR FILTRATION in HVAC Systems

The Leader in Performance Indoor Air Quality Measurements

New Montgomery County Elementary School. Construction Indoor Air Quality Management Plan IEQc3.1 IAQ Plan During Construction

APPLICATION FOR EMPLOYMENT

Reflow Oven. USA HEADQUARTERS:

Using the PPM2 Portable Trace Moisture Transmitter

testo 340 Speed, power & precision in industrial combustion analysis.

Introduction Presentation Slide Notes

Dublin Airport Air Quality Monitoring Q1, Q2 2017

Optimisation of an HVAC system for energy saving and thermal comfort in a university classroom

Paper 4: Environmental Chemistry Paper 23: Air pollution controls, their chemistry and continuous monitoring instruments

Opening Roof Specialists. Builders Kit

LEED v4 Building Design and Construction Quiz #8 EQ

testo 330 Flue gas analysis with increased convenience and safety

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

How safe is Beijing s Air Quality for Human Health? Naresh Kumar Θ

On-Line Carbon in Ash System at PPL Montour for Increasing Ash Sales

Evaluating Environmental Monitoring Applications of Low-Cost Sensors for

Visibly clean, Elegantly designed, Convenient Reasonably priced, Air Purifier clair

2008 CAPTURE AND CONTROL OF PROCESS FUGITIVE AIR EMISSIONS IN A BUILDING

Product data sheet Palas Condensation particle counter UF-CPC 100

Application for Employment

Municipal Wastewater. Introduction: Sample Matrix: Wastewater; various locations along the sewage treatment process.

SOME ENERGY-EFFICIENT TECHNOLOGIES IN JAPAN

PM Compliance Options for MACT and MATS Rules. Ed McCall PCME

Construction Indoor Air Quality (IAQ) Management Plan

TABLE OF CONTENTS SELECTING AN ENCLOSURE COOLING SYSTEM MANUFACTURER. 3 7 QUALITIES TO LOOK FOR IN A MANUFACTURER Manufacturer Location..

6.1 INTRODUCTION 6.2 REGULATORY FRAMEWORK NATIONAL AMBIENT AIR QUALITY STANDARDS COMPLIANCE STATUS TRANSPORTATION CONFORMITY

Transcription:

Fine Dust Sensor FDS 15 PM 2.5 PM 10 IN OUT WLAN 4...20 ma out Modbus 24 h

One device, many application possibilities. The FDS 15 is characterized by its clear and simple design and by the precision of the fine dust measurement of PM2.5 or PM10. The fine dust instrument is a true multifunctional sensor for variety of applications in different industry segments. Air Management System automatic control for air supply and exhaust air in buildings Air Quality System for better indoor climate and for your health Ambient Monitoring focus on environmental protection and health care Workplace Monitoring for more efficiency and quality assurance in the workplace Filter Monitoring efficiency improvement of filters in ventilation system control Controlling Tool energy saving by identifying diffuse sources Benefit Kit optimal supplementation and networking with other environmental sensors or stations PM 2.5 PM 10

Dust content [µg/m³] 70 60 50 40 30 20 10 0 Fine dust measurement at workplace * 06:00 08:00 10:00 12:00 14:00 16:00 Time * Welding smoke measurement (PM2.5) in closed room

Monitoring the fine dust regardless of the weather. The FDS 15 sensor is ideally suited for indoor air monitoring as well as for the outdoor environmental parameter measurements. The fine dust is determined by optical scattered light measurement. Thereby the air is sucked in and depending on the ambient temperature it is automatically preheated to 50 C. In case of PM2.5 the conditioning is made by cyclone. The measuring cell is forced through an integrated fan. By means of the selected measuring gas velocity and the optical scattered light all the particles can be recorded representative. The automatic zero-point setting by an integrated electrostatic precipitator allows constant comparable results in the range of 2 to 2000 µg/m³ even in heavily polluted environments. This patented technology is almost maintenance-free. The compact aluminium housing and the safe power supply ensure that the measurements are possible to execute in any weather conditions. IN OUT

Stationary fine dust measurement 70 Dust content [µg/m³] 60 50 40 30 20 10 0 Mon Tue Wed Thu Day Fri Sat Sun Measuring values of FDS 15 (PM2.5) Measuring values of a public meas. station (PM2.5)

Area-wide measurement. The networking of several fine dust sensors creates a clear added value. The integrated WLAN module as well as the standard interfaces for data output make it possible. An urban fine dust measurement network is the modern answer to questions concerning the health hazards by real environmental impact of PM2.5 particulate matter pollutants. There are targeted and well-founded conclusions on weather phenomena and particulate matter pollutants. The installation is simple and the maintenance requirements minimal. WLAN 4...20 ma out Modbus

Continuous and future-oriented. The FDS 15 provides you security in compliance with globally applicable limits. Stable reliable measurements 0 53 µg 30 µg Markranstädt Mobile fine dust measurement 82 µg 126 µg 113 µg Start/Target: Dr. Födisch Umweltmesstechnik AG Permanent meas. station: FDS 15 (PM2.5) / public (PM10) Dust content [µg/m³]: 25 50 West South-West 0 Leipzig 3 km 75 100 125 125 1 Centre South 2 Fully equipped industrial instrument in low-cost price range Stationary or mobile fine dust measurement Data output as average in minutes / hours / days or weeks value, current and historical outputs Alveolar PM2.5 fractions of particulate matter determined by the integrated pre-separator PM10 particle measurement as a supplement to public measuring stations 24 h

Contact and additional information. We are pleased to answer your questions in person. In addition, you will find the technical details in the product data sheet and the practical examples in our reference brochure. You benefit from our many years of experience in process and environmental measurement technology our profound knowledge in the field of environmental legislation optimal and customer-oriented solutions Dr. Födisch Umweltmesstechnik AG Zwenkauer Strasse 159 04420 Markranstädt Germany Phone: +49 34205 755-0 Fax: +49 34205 755-40 E-mail: sales@foedisch.de www.foedisch.de