ASCE 7-16: Changes to Wind Calculations for Rooftop Solar

Similar documents
Solar Standards Development

Wind Loads on Rooftop Solar Panel Systems: A Contribution to NBCC 2015

WITH THE TITLE 24. replacement. story. stories, etc. R disconnects. to, PV. unit and any. supporting frame. conditions. greater than the main

Name: McNaughton - McKay Elec. Designed by JMadrid. Address: None RM-BALLASTED FLAT ROOF. City, State: Unknown, Watt Panels

APPENDIX. WOOD JOIST/RAFTER MAXIMUM SPANS ( for 16 o.c. spacing) WITH SINGLE ROW OF PV PANELS AT MIDSPAN (ft.) AND PANEL SUPPORT AT 32 o.c.

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

Snow load design using the 2003 International Building Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

The requirements set forth in this Section shall govern the construction and/or installation of all Renewable Energy Systems:

PR-L274 Nordic Structures Revised April 16, 2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

LATERAL LOADS ON BRICK VENEER RESIDENTIAL STRUCTURES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

Wind loads at solar and photovoltaic modules for large plants

2012 Wood Frame Construction Manual: Wind Speed and Design Pressure Determination According to ASCE 7 10

DESIGN & ENGINEERING GUIDE

6KW Grid Interactive Photovoltaic System

Florida Structural Engineers

National Capital Region Recommendations for Residential Solar PV Systems

ADM4-16,Pt I Page 19 ADM4-16,Pt II Pg 21 ADM4-16,Pt III Pg 23 ADM9-16,Pt I Page 25 ADM49-16 Page 28 ADM10-16,Pt II Pg 30. Summary

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

OVERVIEW OF SERVICES WIND ENGINEERING AND AIR QUALITY CONSULTANTS

Live Load Considerations for Truss Bottom Chords

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

Wind Tunnel Applications for Buildings

Vulnerability modelling of metal-clad industrial buildings to extreme wind loading

VMA C (Revision 2)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Evaluation of Wind Loads on Solar Panels

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

ESR-3284 Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

Home PV System Design

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

WIND LOADS ON BALUSTRADES. Antonios W. Rofail a, Christian Mans a

June 1, 2012 PARTIES INTERESTED IN COLD-FORMED STEEL FRAMING MEMBERS

February 1, SUBJECT: Proposed Revisions to the Acceptance Criteria for Staples, Subject AC R1 (EL/JF)

Market Requirements Document

Re-Roof Permit Checklist

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Originally Issued: 03/13/2015 Revised: 03/10/2017 Valid Through: 03/31/ Description

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

USING WOOD STRUCTURAL PANELS FOR SHEAR AND WIND UPLIFT APPLICATIONS

Special Inspections for Wood Construction BCD710 Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Building Codes in Effect: 2010 California Building, Residential, Fire, Energy and Electrical Codes, including Article 690.

ALTERNATIVE ENERGY RESOURCES ORDINANCE

AC R1 # Triangle Parkway Suite 100 Norcross, Ga Phone: Fax: AC R1. September 11, 2012

ATI Evaluation Service A Division of Architectural Testing Certification Services

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

Understanding IBC Wind Load Requirements for Generating Systems

Shear Wall Design Examples per 2015 WFCM and 2015 SDPWS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

ASCE 7-10 Significant Changes to the Wind Load Provisions

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

AC R2 8. ECO-Block, LLC. May 23, ICC Evaluation Service, Inc Workman Mill Road Whittier, California 90601

Common Errors in Truss Design

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: LOUISIANA PACIFIC CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

December 3, 2012 PARTIES INTERESTED IN INTUMESCENT FIRE-RESISTANT COATINGS FIELD-APPLIED TO PREFABRICATED WOOD I-JOISTS

High Performance and Durability of Commercial Construction

KEEPING UP WITH I-CODES

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

Installation Guide EcoFoot5D High Density 5-Degree Ballasted Racking System Document No. ES10560

The provisions of this document apply to Residential projects, as well as Commercial and Multifamily projects not exceeding a height of 75 feet.

Joint Evaluation Report ICC-ES (800) (562)

Case Study: Failure at an Abutting Lower Roof due to Snowdrift

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

Solar Cell Optimization: Cutting Costs and Driving Performance

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

LP SmartSide Strand Substrate Treated-Engineered-Wood Lap & Panel Siding Louisiana-Pacific Corporation Revised December 2, 2016

ATI Evaluation Service A Division of Architectural Testing Certification Services

Click to edit Master title style. Entergy New Orleans 5 MW DG Scale Aggregated Solar PV Project

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

LP OSB Sheathing & Structural 1 Sheathing

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

APVI Solar Potential Tool Data and Calculations

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

Solar Ready Homes/Solar Oriented Developments Residential Stakeholder Meeting

December 20, 2006 PARTIES INTERESTED IN EVALUATION REPORTS ON PATIO COVERS

ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

PRODUCT OVERVIEW PV FLAT ROOF MOUNTING SYSTEMS

Tested Guardrail Post Connections for Residential Decks By Joseph Loferski, Dustin Albright, and Frank Woeste, Ph.D., P.E. Copyright.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

Originally Issued: 12/18/2015 Revised: 04/14/2017 Valid Through: 12/31/2017

TECHNICAL INFORMATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Transcription:

ASCE 7-16: Changes to Wind Calculations for Rooftop Solar Joe Cain, P.E. Chair, SEIA Codes & Standards Working Group David Banks, PhD, P.Eng Principal Cermak Peterka Petersen (CPP)

ASCE 7-16: Changes to Wind Calculations Agenda Market Trends Current Practice General changes to ASCE 7-16 Solar-specific changes to ASCE Mitigations in SEAOC PV2 update 2016 Solar Energy Industries Association 2

Residential Market Trends 2010 to 2016 July 11, 2017 2016 Solar Energy Industries Association 3

Calculation of Wind Pressure: ASCE 7-10 and ICC-ES AC 428 Determine design wind speed and calculate design wind pressures using ASCE 7-10 ICC Evaluation Services Acceptance Criteria AC 428: Acceptance Criteria for Modular Framing Systems Used To Support Photovoltaic (PV) Panels AC 428 is required to obtain an ICC-ES Evaluation Report; it is also useful as voluntary guidance AC 428 allows internal pressure set equal to zero (within constraints) in Components & Cladding method In future ASCE 7-16, there will be a calculation method specific to flush mounted PV systems on sloping pitched roofs 2016 Solar Energy Industries Association 4

ICC Acceptance Criteria AC 428 Components & Cladding method Internal pressure shall be set equal to zero Physical constraints are needed for method to be valid Pressure equalization is dependent on gaps between modules 2016 Solar Energy Industries Association 5

ASCE 7-10 with ICC-ES AC 428 Criteria Physical constraints of AC 428 wind method: Required 10 inch minimum distance from roof edge or ridge Height above roof between 2 inches and 10 inches Minimum gap of 0.25 inch between adjacent rows of panels In earlier version of AC 428, minimum gap was 0.75 inch 2016 Solar Energy Industries Association 6 Don t forget to consider: Roof edge zones, which are changing in ASCE 7-16 Fire setbacks, which are changing (for the better) in 2018 IFC & IRC

ASCE 7-16 Wind Speed Maps Revised (again) Risk Category II Mean Recurrence Interval (MRI) 700 years) ASCE 7-16 wind speed maps show contour lines in Western states 2016 Solar Energy Industries Association 7

C&C Roof Zones: ASCE 7-10 to 7-16 ASCE 7-10 Figure 30.4-2C ASCE 7-16 Figure 30.43-2D 2016 Solar Energy Industries Association 8

Development of Corner & Edge Roof Zones ASCE 7-10 Roof Zones ASCE 7-16 Roof Zones 2016 Solar Energy Industries Association 9

Roof GC p Coefficients: ASCE 7-10 to 7-16 ASCE 7-16 Figure 30.43-2D ASCE 7-10 Figure 30.4-2C 2016 Solar Energy Industries Association 10

University of Western Ontario: Stenabaugh Experiments were conducted in UWO boundary layer wind tunnel Two primary areas of investigation Height of PV system above roof Pressure equalization from various gaps between PV panels 2016 Solar Energy Industries Association 11

University of Western Ontario - Stenabaugh 2016 Solar Energy Industries Association 12

ASCE 7-16 with Associated Criteria Physical constraints of ASCE 7-16 method: Required minimum distance from roof edge or ridge 2h 2 Height above roof between 2 inches and 10 inches Minimum gap of 0.25 inch between all panels 2016 Solar Energy Industries Association 13

DRAFT ASCE 7-16 Section 29.4.4 Basic form of Equation 29.4-7 is very familiar Velocity pressure q h times pressure coefficient GC p New coefficients g E and g a are solar-specific for flush mounts installed parallel to roof 2016 Solar Energy Industries Association 14

Zone 1: ASCE 7-16 GC p Pressure Coefficients 2016 Solar Energy Industries Association 15

Zone 1: Wind Pressure Equalization Factor 2016 Solar Energy Industries Association 16

Zone 1: Add ASCE 7-16 CA Wind Speeds 2016 Solar Energy Industries Association 17

Zone 1: Closer to Roof, with PV2-2016 Equalization 2016 Solar Energy Industries Association 18

DRAFT Update to SEAOC PV2 Wind Paper Original SEAOC PV 2 wind paper was published in October 2012 Dr. David Banks of CPP Wind is primary author of PV2 update PV2 paper is updated to all requirements of ASCE 7-16 Updated PV2 is expected to be published by the end of 2016 ASCE 7-16 intended to be referenced in the 2018 IBC, and in effect by January 1, 2020 in most states 2016 Solar Energy Industries Association 19

ASCE 7-16: Exploring the Edge Factor, g E Edge Factor g E ( gamma E ) is a direct, linear multiplier to the wind pressure The value of g E is either 1.5 or 1.0 In ASCE 7-16, panels within 1.5 L p from end of row are exposed Result is three rows or fewer are 100% edge 2016 Solar Energy Industries Association 20

Mitigation for g E in (DRAFT) SEAOC PV2 Update Flush mount only Likely to be 2*h2 from array edge in final PV2-2016 2016 Solar Energy Industries Association 21

ASCE 7-16: PV Pressure Equalization Factor, g a Equalization Factor g a is a direct multiplier to wind pressure Wind pressure is reduced for gaps between panels John Wolfe public comment was disapproved by the ASCE Wind Subcommittee 2016 Solar Energy Industries Association 22

Mitigation for g a in DRAFT SEAOC PV2 Update SEAOC PV2 update will include more options for pressure equalization Options are height of PV system above roof and gaps between modules This alternative method rewards designs that consider optimization for wind Wind pressures can be reduced by 25 percent from worst-case basis of ASCE 7-16 2016 Solar Energy Industries Association 23

Questions? Contacts Codes & Standards: Joe Cain, P.E. Chair, SEIA Codes & Standards Working Group E-mail: JoeCainPE@gmail.com Phone: +1-408-605-3934 David Banks, PhD, P.Eng Principal, CPP Wind E-mail: dbanks@cppwind.com Phone: +1-970-498-2350 2016 Solar Energy Industries Association 24

Development of Corner & Edge Roof Zones 2016 Solar Energy Industries Association 25

Development of Corner & Edge Roof Zones 2016 Solar Energy Industries Association 26