3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

Similar documents
3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

Instructions for. Pro AND. Pro. Indoor Air Quality Monitors. Cropped picture here

Online Gas Analyzer / Monitor

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

DR1000 Flying Laboratory, Drone Environmental Monitoring

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

Technical Note TN-114 rev 16 wy/wh.11-04

GAS 3050P NDIR FLUE GAS

RESTORE 1030TM Testing Protocol

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

Title: Standard Operating Procedure for the Collection of VOCs in Ambient Air Using Summa Canisters and Xontech Sampler

Instructions for Use: Temp-USB-TP and Temp-USB-TH

VOCs, CO 2, LEL, H 2 S, CO, O 2, SO 2, PH 3, NH 3, NO 2, HCN, Cl 2, ClO 2, O 3. Protect yourself. General Specifications

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Instruction Manual Dräger MSI EM200-s

Camera Eyepiece. User s Manual. KS035200G4-Ver1.0

Sensor Specifications and CroSS- Sensitivities

Sensor unit MC2 for toxic gases and oxygen with analog output

Coating Thickness Meter Data Sheet / Instructions

SCOTT PRO 2 CARTRIDGE FILTERS TECHNICAL DATA SHEET

The Leader in Performance Indoor Air Quality Measurements

WBEA Standard Operating Procedure

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

CONTENTS GENERAL Weighing Introduction

Online data sheet MCS100E HW-C CEMS SOLUTIONS

3SP_CO_1000 Package

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Fpollutant-free zero air for analytical

WELCOME. Standard Change Makers, Inc. Changer Maintenance Overview General Maintenance Guide for Standard Change-Makers Machines

Monitoring for Toxic VOCs in Oil Industry Applications

COp 28 CO2% 6.2. O2 CO Air Free. Eff X-Air. Temp. Fuel. Date Time C85 LONG LIFE EOS ANALYZER

Compact flue gas analyser: testo 300 M-I

an ISO9001 company TECHNICAL INFORMATION FOR TGS2600 Technical Information for Air Quality Control Sensors

Using the PPM2 Portable Trace Moisture Transmitter

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Please read these instructions before use and retain for future reference

! CAUTION: Read and follow these instructions.

Monitor your network and report service issues quickly

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

Precision Automatic Vacuum Control (PAVC+)

TVOC Heated FID VE 7

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

X30 System Components

Checklist of Common Critical Data Issues:

Combustion Control Ltd.

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Winzer Corporation 1 Revision: 4.0

Closed Dispense Systems

MERIGAUGE MODEL 3900 OPERATING INSTRUCTIONS

testo 340 Speed, power & precision in industrial combustion analysis.

First Data EFTPOS. User Guide. 8006L2-3CR Integrated PIN Pad

Testing Water Vapor Transmission Rates for Flexible Barrier Materials Including Metalized Structures

SpeedExtractor E-916 / E-914 Technical data sheet

Premium Water Filtration Systems

EXHAUST MANAGEMENT PRIMARILY ACID COMPOUNDS. MINIMAL VOLATILE ORGANIC COMPOUNDS (VOC). HMDS FROM PHOTO CAN BE EXHAUSTED (RATHER THAN TO VOC EXHAUST).

General Air Monitoring/ SCHMT Monitoring Equip. Working to meet established Hazmat Team Goals:

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)

???? Spot Check Measurement Simple, accurate, reliable

HY-ALERTA 500 Handheld Hydrogen Leak Detector

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

INSTRUCTION MANUAL. Voice Command Quadcopter with 2MP Camera

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

Performance Standards for Continuous Ambient Air Quality Monitoring Systems. Environment Agency Version 8 June 2012

Data Logging Solutions from Lascar Electronics

To whom it may concern, February 21, 2011

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

WS 10 Weighing indicator USER MANUAL

The Ton-Tel Weighbridge

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

Thank you for choosing bq. This manual will help you use your new 3D printer correctly. Welcome to the world of Witbox!

Proven. DryCal 800 User Manual

OPERATION MANUAL. Electronic Hanging Scale NINGBO AUDDA WEIGHING CO.,LTD

For highest levels of purity

SPIRIT. Water purifier. Complete User Manual

Testing of Carbon Filters in Australian

Gas concentrations in the air

Ultrasonic Load Monitoring

testo 350 M/XL Short Operation Instruction Manual Rev. 11/03 Instrument Software Version 1.30

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

F Series Flow Meter F300. User Manual

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

8 stream capability with dual mode (H 2 S & total Sulphur)

INDEX. 1 Introduction. 2 Software installation. 3 Open the program. 4 General parameters. 5 Tuning

User s Manual. esims Web. Synthes Information Management Suite.

CHAPTER 6 : GAS SAMPLING SYSTEMS

INSTRUCTION & OPERATIONS MANUAL. E8500 Plus PORTABLE INDUSTRIAL INTEGRATED EMISSIONS SYSTEM COMBUSTION GAS ANALYZER

MODELS PH PH PH

TSI Model 3063 Thermal Mass Flowmeter

Power Express Sample Processing System

PharmaClik POS Overview

Crowcon Technical Note

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

Transfield Services Limited

Scanning Devices Label Counting Table Operations Manual

Transcription:

3M Personal Safety Division 3M TM EVM Series Environmental Monitor EVM Series Quick Start Guide

EVM and User Interface Indicators Display Softkey menus Backlight Particulate pump Left arrow key Run/Stop key Up arrow key Altf key Enter key Right arrow key Down arrow key On/Off and Esc key Turning On/Off and Navigating 1. Press key power on. (Following a splash/welcome screen, the Start screen will appear.) 2. Navigating to measurement screens - press keys. Navigating to menu options - press keys. To open a selected menu or to save settings - press key. 3. In the powered on mode, press and hold key to power down the instrument. Start Screen and Measurement Views You will visit the start screen frequently to access measurements, setup, calibration, unit info, and file system screens. ;; Press keys to access the measurements screens. ;; To select a menu option, press keys.

Overview of running measurements Quick Help List: typical gas, particulates,or air quality measuring overview 1. Turn the EVM on and check the battery power. 2. Reset/Clear memory, if necessary (Start\File System menu). This will clear out data history before your logging begins to ensure you have sufficient memory space. 3. Set-up your session parameters either in 3M TM Detection Management Software (DMS) or via the instrument s Setup screen. 4. Verify the time and date is set correctly (Setup\Time-Date menu). 5. Calibrate each sensor/parameter via the Calibration screen. 6. Place the EVM in a specific location for area monitoring. 7. Press the key to Start logging. 8. When you are ready to end your logging, press key. 9. Review your results either on the instrument (via the File System screen) or download to DMS for further analysis (graphs/charts, saving and printing). Particulate Measurements Particulate setup 1. To change particulate settings select: Setup\Particulate. 2. Particulate screen appears and includes the following adjustable fields: Particulate field (enable/disable pump collection), Profile field (applying a correction factor), and Gravimetric mass/volume fields (displays accumulated mass and air volume. These fields are reset when performing gravimetric sampling.) Adjusting the Impactor To adjust the impactor, turn the turret until one of the following is selected: PM2.5, PM4, PM10, or PM (all dust ranging from 0 μm-100 μm). The example below illustrates the impactor set to PM 2.5. PM 2.5 Align to impactor arrow

Particulate Zero Calibration Prior to calibrating, ensure the impactors are well-greased with an applied thin-film of silicone grease. (Please see Impactor Care on page 10 or EVM series user manual.) 1. Attach the Zero/HEPA filter and tubing into the turret. Rotate the turret to PM. 2. Select Calibration from the Start screen and select PM (using up/down arrows). 3. Press Cal softkey and then press Start softkey. Once level is stabilized, press Set softkey. 4. Once level has been set, you can press Save or Cancel. (Please refer to Chapter 4 of EVM series manual for more information.) ;; NOTE: Once saved, the instrument will apply the zero calibration to all profiles. The zero calibration is stored in the History screen and a calibration. Verify can be performed (to ensure no drifting). Zero/HEPA filter example Used for particulate zero cal. Tubing and vent opening Insert tubing into the impactor of the labeled 2.5 vent opening Turret Turn the turret so PM appears on the display of the EVM. Particulate Advanced Calibration (Gravimetric) Gravimetric Calibration Overview (1)Reset the gravimetric and volume accumulators; (2) Insert a new (sealed) gravimetric cassette; (3) Measure in the specific location for approximately four to eight hours; (4) Record the value displayed in the gravimetric accumulator field displayed in the particulate screen. (This value is used in conjunction with the weight of the measured dust in the cassette.); (5) Remove the gravimetric cassette and weigh the filtered contents. (Typically, send to a lab for results.); (6) To determine the correction factor, calculate the ratio between the particulate mass value and the weight from the gravimetric filter lab analysis. (Ratio = true weight/evm gravimetric displayed value). (7) Enter user correction value (Setup\Particulate screen. Select profile field and then press Edit softkey. Add Factor using up/down arrows. Press On/OFF/Esc key twice to return to start screen.) Logging Particulates 1. Before logging particulates, ensure the impactors are clean and well-greased. 2. From the start screen or any measurement screen, press key. 3. Press key to end the logged session. (See Viewing logged results to access past sessions.)

Volatile Organic Compounds (VOCs) VOCs, air pollution with carbon-containing chemicals, are measured using a Photoionization detector 10.6eV. The EVM is equipped to notify you when maintenance and cleaning is required for the PID sensor. A PID sensor error will appear indicating: (1) if the sensor needs to be cleaned, or (2) the lamp needs replacing. PID Zero Calibration The PID ppm zero calibration preferred method is to flush with Zero Grade Air. Alternatively, Nitrogen may be used. For best response time, it is recommended to set the flow rate at 1 LPM. NOTE: Please refer to the EVM series manual for more information on the PID ppm/ ppb sensors. 1. Connect the Zero Grade Air, tubing, and cal. cup to the EVM. (Please skip this step if you are not applying a gas.) 2. Select Calibration from the Start screen and select PID (using up/down arrows). 3. Press Cal softkey and then press Zero softkey. Once level is stabilized, press Set softkey. (Typically takes 60 seconds to stabilize.) 4. Once level has been set, you can press Save or Cancel. (Disconnect components and return to the start screen via On/Off/Esc key.) PID Span Calibration Typically, Isobutylene is used when the VOCs are unknown. NOTE: in order to measure specific VOCs, you will want to use the relevant VOC for your calibrated gas source for a ppm/ppb sensors. (Please refer to the manual for PID correction factor table; Appendix C for details.) 1. Connect Isobutylene, regulator, tubing and cal cap to the EVM. 2. Follow steps 2-4 above (in PID Zero Cal. section) but select Span softkey instep 3. Logging VOCs 1. From the start screen or any measurement screen, press key. To view VOCs measurements, select either the Gas or Composite screen by pressing keys from the start screen. 2. Press key to stop logging. (See Viewing logged results to access past sessions.) Run icon PID sensor measurement Gas measurement screen

Toxic Gases The following toxic gases table displays a quick overview of the ranges and the gases needed to perform zero and span calibrations. Type of Gas Range Res. Zero cal gas Span cal gas Carbon Monoxide (CO) 0-1000 ppm 1 ppm nitrogen/pure air CO Chlorine (CL 2 ) 0.0-20 ppm 0.1 ppm nitrogen/pure air CL 2 Ethylene Oxide (EtO) 0.0-20 ppm 0.1 ppm nitrogen/pure air EtO Hydrogen Cyanide (HCN) 0.0-50 ppm 0.1 ppm nitrogen/pure air HCN Hydrogen Sulfide (H 2 S) 0-500 ppm 1 ppm nitrogen/pure air H 2 S Nitrogen Dioxide (NO 2 ) 0.0-50 ppm 0.1 ppm nitrogen/pure air NO 2 Nitric Oxide (NO) 0.0-100 ppm 0.1 ppm nitrogen/pure air NO Oxygen (O 2 ) 0.0-30% 0.1% nitrogen *1.0 L/min. flow rate Room air *span 20.9% Sulphur Dioxide (SO 2 ) 0.0-50 ppm 0.1 ppm nitrogen/pure air SO 2 Carbon Dioxide Gas Similar to toxic gases, the carbon dioxide sensor should be calibrated prior to logging. Toxic and Carbon Dioxide Zero Calibration Depending on the gas of interest, the toxic zero calibration is performed with the gas indicated in the table above. The CO 2 sensor requires a calibration gas, a regulator with at least 1.0 Liter/minute flow rate, and a hose/tubing. Nitrogen (N 2 ) is the recommended gas for a zero calibrating (If you are not applying a gas, start at step 2.) 1. Connect the appropriate gas/pure air, regulator, tubing, and cal. cup to the EVM. 2. Select Calibration from the Start screen and choose a specific toxic using keys. (i.e., CO). 3. Press Cal softkey and then press Zero softkey. Once level is stabilized, press Set softkey. (Allow at least 90 seconds to stabilize.) 4. Press Save or Cancel softkey to store the process. Disconnect components and return to the start screen via On/Off/Esc key. Cal. cup/adapter Tubing Regulator Cal. gas source

Toxic and Carbon Dioxide Span Calibration To perform a span calibration with a specific toxic gas, please reference the toxic gas table. For the CO 2 span calibration, the range (or span) should be a sizeable fraction of the selected full scale range of the gas. ;; NOTE: The range for the CO 2 sensor is 0 to 5,000 ppm. For a span calibration, it is recommended to span cal to the value you will be measuring (i.e., 2,000 ppm). 1. Connect the appropriate gas, regulator, tubing and cal cap to the EVM. 2. Follow steps 2-4 above (in Toxic Zero Calibration section) but select Span softkey in step 3. (NOTE: For Oxygen span calibration, the typical span is 20.9%.) Logging Toxic Gases or Carbon Dioxide 1. From the Start screen or any Measurement screen, press key. To view gas measurements, select either the Gas or Composite screens (by pressing from the start screen when Setup is selected.) 2. Press key to stop logging. (See Viewing logged results to access past sessions.) Run Icon CO 2 value Toxic (CO) value Composite Measurement screen Particulate advanced calibration (Gravimetric filtering) Gravimetric Calibration Overview (1)Reset the gravimetric and volume accumulators; (2) Insert a new (sealed) gravimetric cassette; (3) Measure in the specific location for approximately four to eight hours; (4) Notate the value displayed in the gravimetric accumulator field (displayed in the particulate screen. (This value is used in conjunction with the weight of the measured dust in the cassette.); (5) Remove the gravimetric cassette and weigh the filtered contents. (Typically, sent to a lab for results.); (6) To determine the correction factor, calculate the ratio between the particulate mass value and the weight from the gravimetric filter lab analysis. Measuring particulates 1. From the start screen or any measurement screen, press the key. (Prior to logging, a 5 second count-down appears.) 2. Press key to end the logged session. (See Viewing logged results to view past sessions.)

Temperature and Relative Humidity Logging/Viewing Temperature and/or Relative Humidity The Temperature and Relative Humidity readings are viewable in either the Temp-RH measurement screen or in the Composite screen. Temp/RH measurements Temp/RH measurement screen Particulate Air Flow Calibration For Airflow meter calibration, an accurate flow meter (such as a primary standard calibrator) and tubing is required. 1. Attach the primary standard calibrator tubing to the air flow outlet. 2. Navigate to the Setup\Calibration\Flow RT (rate) screen. 3. Press the Cal softkey and then press Start softkey. 4. Adjust the flow rate (using the up and down arrow keys) so the primary standard calibrator is 1.67 LPM and then confirm by pressing the Save softkey. ;; NOTE: It should be noted that in order for the impactors to work properly the flow rate must be adjusted to 1.67 LPM. AirProbe inlet with attachment Air Flow Outlet *To calibrate, connect primary standard calibrator with tubing

Air Velocity To view air velocity measurements, perform or verify the following: 1. The air velocity probe is enabled in Setup\AUX\Air Velocity screen. 2. Connect the air velocity probe and attachment to the EVM unit to the auxiliary Air probe inlet. (See Air Probe inlets diagram in previous section, Particulate Air Flow.) 3. Turn Air Velocity Probe switch On. 4. Navigate to the Air Velocity measurement screen using keys. Connect AirProbe to the back housing (two inlets located near the air flow outlet. See air flow diagram on previous page.) Air velocity measurement screen Viewing Logged sessions (past sessions) Once you have logged data and stopped the session, the data is stored under the past session summary menu. (Optional: you can view the data in charts/graphs when downloaded to DMS.) 1. Navigate to Start \Past Session screen. 2. Select the File field and press the File softkey. (Past Session\Load File screen will display all of the logged files.) Press Enter key to change between different file views. 3. Select the appropriate file (by using up/down arrows) and press the Load softkey 4. Press Detail softkey to view data. 5. Press keys to view summary data. Repeat as necessary. Session Run Time Summary session

Maintenance/Cleaning Sensors Locations The gas sensors are inserted, factory calibrated, and ready for usage upon delivery. (The diagram below is based on the EVM-7 model.) Occasionally, you may have to care for the sensors which will require removing and inserting. ;; NOTE: Verify the unit is off and unplugged from the power cord before removing or inserting sensors. 1. Remove the sensor bar (via the screws) and remove the manifold. Manifold 2. Sensor bar removal and location of sensors are displayed below. When removing/inserting, align the socket pins to the circuit board accordingly. Sensor bar - Remove screw 1 & 2 and lift off cover Screw 1 Screw 2 Toxic sensor PID sensor CO 2 sensor Impactor Care and Particulates The impactor requires periodic greasing and cleaning for particulate measuring only. 1. Remove the turret (red housing cover over the impactor) by removing the right and left screw with the supplied allen wrench (stored behind the access door.) 2. Remove all debris/dust with a Q-tip/cotton. 3. Wipe a very thin film of silicone grease onto the metal plates using a Q-tip/cotton. 4. Re-attach by placing the turret cover over the housing and tighten screws. Thin-layer of silicone is applied to a clean impactor. Example of accumulated dust (will form into a pyramid)

Working with 3M TM Detection Management Software DMS Communicating 1. When the EVM is On, plug the USB cable into the EVM and plug the opposite end to the USB port of your computer. (Refer to illustration below.) Viewing your data In DMS once your files are downloaded via Download button, view the data in the panel layout view or reports by clicking on appropriate buttons. See an example of the panel layout page below.

Personal Safety Division 3M Detection Solutions ISO 9001 Registered Company ISO 17025 Accredited Calibration Lab 1060 Corporate Center Drive Oconomowoc, WI 53066 Customer Service: 262-567-9157 Toll Free: 800-245-0779 www.3m.com/detection 3M is a trademark of 3M Company, used under license in Canada. Please recycle. Printed in USA. 2013 3M. All rights reserved. 074-301, Rev.D. 4/13