SCION GC Series. The Gas Chromatographers Choice for Separations

Similar documents
SCION GC Series. The Gas Chromatographers Choice for Separations

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Super Clean Gas Filters Simply the best

SIMPLIFY AND ACCELERATE GAS ANALYSIS. Micro GC Fusion GAS ANALYZER

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Agilent Gas Phase Solutions

Capillary GC Troubleshooting: a Practical Approach

System Overview. Valve oven. Restrictor. Valve. Sample in and out

Gas Chromatography Assignment Chem 543/443

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

PAL SPME Fibers Optimized for Automation

Agilent Ultimate Plus Fused Silica Tubing

NATURALLY BETTER CHROMATOGRAPHY SOLUTIONS. Clarus Gas Chromatographs Clarus 680/580/480

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Dräger Gas Filtration SUPER CLEAN GAS FILTERS. Dräger: Technology for Life

Gas Chromatography (GC) Operation, Calibration, Troubleshooting and Practice Maintenance

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

The Analysis of 4-Vinyl-Cyclo-Hexene (VCH) in Butadiene with the DVLS LGI Injector

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Fast Detailed Hydrocarbon Analysis by Modified ASTM Method D6730

STANDARD OPERATING PROCEDURES

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

HYDROGEN AS A CARRIER GAS. Gas Chromatography new frontiers: can Hydrogen substitute Helium?

It works as hard as you do.

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

PerkinElmer Supplies/Parts. GC Accessories. Autosampler Syringes

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

GC8000 Process Gas Chromatograph. Bulletin 11B08A01-01E

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

Chrom-Card Data System. A simple, chemist-oriented data handling system...productive from the first day!

C146-E096 TD-20. Shimadzu Thermal Desorption System

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

GAS CHROMATOGRAPHY CLARUS 400/480 GC

Preparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions

Hydrogen Generators Flow Capacities up to 500 cc/min

Gas Generators. Parker Balston

Greenhouse Gas Measurement Technology

BÜCHI Labortechnik AG

Fast Analysis of Extended Natural Gas using the New Transportable INFICON Micro GC Fusion

MATERIALS OF CONSTRUCTION

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Separation and Quantitation of a Mixture of Alcohols by Gas Chromatography

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Method Translation in Liquid Chromatography

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

PATHFINDER 350A ARCHIVER YOUR ANSWER TO CAPPING, SORTING AND ARCHIVING OF SAMPLE TUBES

NovaWAVE. A new category of Automated Microwave Digestion

Atlas Copco Control Solutions. ES Cutting-edge central control capability

Impact of GC Parameters on The Separation Part 4: Choice of Film Thickness

TANGO. ANALYSIS TO GO. Innovation with Integrity. The next generation FT-NIR spectrometer. FT-NIR

Sum Parameter Analysis AOX/TOX. AOX Analyzer multi X 2500

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Agilent 7890B Gas Chromatograph RESOLVE YOUR SEARCH FOR RELIABILITY

Chambers and Instrumentation CHAMBERS. STORA: 22 m 3 chamber

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Transactions on Ecology and the Environment vol 14, 1997 WIT Press, ISSN

Preparative, Pilot & Process Columns

Gas Generator ULTRA HIGH PURE - HIGH FLOW. Gas Generator

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Using the PPM2 Portable Trace Moisture Transmitter

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Select Al2O3 MAPD : a new Inert Al2O3 column for the trace analysis of polar reactive hydrocarbons.

MILESTONE MILESTONE ETHOS X. Advanced Microwave Extraction System for Environmental Applications

Solutions. Integrated Analyzer Systems & Services. Your Global Partner For Customized Analytical Solutions

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED.

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Qualification of High-Performance Liquid Chromatography Systems

Hydrogen Generators. for GC combustion detector applications. Product Features: Contact Information: ENGINEERING YOUR SUCCESS.

Electron Capture Detector for GC-2010 Plus

SpeedExtractor E-916 / E-914 Technical data sheet

Gas Chromatograph. GC-8A Series C184-E016B

MonTech RP 3000 Rapid Plastimeter for Polymers and Natural Rubber

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

IC-D3160 Ion Chromatograph

Overview of preparative HPLC. Analytical Technologies Limited

Agilent 6430 Triple Quadrupole LC/MS System

Synthetic Rubber Plants

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Experiment 3: The Chromatography of Organic Compounds

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Complexity. C9+, H2S, methanol, wet gas. Fiscal / Custody transfer. Simpler installation /operation

Fusion UV/Persulfate TOC Analyzer

Analyzing & Testing. Guarded Hot Plate - GHP. Method, Instrumentation, Applications. GHP 456 Titan. Leading Thermal Analysis

TVOC Heated FID VE 7

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC June 2014

ANALYTICAL GAS GENERATORS

SERVO-HYDRAULIC UNIVERSAL TESTING MACHINE SERIES A

PRIMARY GRADE WATER. PURELAB Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

Carbon / Sulfur Analyzers

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

RHEOLOGICAL PROPERTIES ROSAND RH7 & RH10 RHEOLOGICAL INSTRUMENTS BACKED WITH RHEOLOGICAL EXPERIENCE

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Thermo Scientific GENESYS 10S Bio spectrophotometer

Experiment 2: The Chromatography of Organic Compounds

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Transcription:

SCION GC Series The Gas Chromatographers Choice for Separations

Innovation in Gas Chromatography Scion Instrument s tradition of innovation and product reliability have combined to create the next generation of Scion Instrument s Gas Chromatographs. By understanding and then designing to exceed the most critical performance and reliability needs of GC users, Scion Instruments is delivering systems that are specifically for, and all about helping GC users. The new SCION 436 and SCION 456-GC have been designed to meet users most critical requirements - reliable performance, ease of use and simple maintenance. Local User Interface Users can navigate effortlessly through all GC setup and control functions using the large, high resolution color touch display. Available in 13 languages to facilitate localized training, operation and support. Fast, Flexible Detection Scion Instrument s comprehensive range of detectors deliver industry leading sensitivity, ease of operation and outstanding reliability. All Scion GC detectors feature rapid data sampling rates (600 Hz), essential for high speed, high resolution separations. Multi-language capability

SCION 436-GC Full EFC capability Up to 3 modules Backflush Option High pressure Injection Ports (0-150 psi) High performance Oven 170 C/min SCION 456-GC Detectors: FID TCD ECD PFPD NPD PDHID MS SQ Inlets: S/SL PTV/LVI COC PWOC Packed/Wide Bore 2 or 3 injectors per GC Gas Sampling Valve Liquid Sampling Valve High pressure Injection Ports (0-150 psi) Full EFC Capability Up to 9 modules (21 Channels) Backflush option High performance oven 150/180 C/min

Enhanced Operator Benefits The SCION GC range meets virtually all application requirements. All SCION GCs are equipped with high resolution Electronic Flow Control to ensure retention time precision. Whatever the requirement, we have the solution. Connectivity and Control from Anywhere Using either the GC Portal interface or the industry leading CompassCDS software, users can easily control and monitor SCION GC hardware from remote locations. Hydrogen Carrier Ready All SCION GC s are capable of using hydrogen as a carrier gas and carry ATEX explosion safety certification. These GC s can also be fitted with hydrogen safety systems, providing users with additional security. LAN

Targeted Software Solutions CompassCDS has several customized software plug-in options to provide users with additional functionality that includes enhanced reporting, complex post-analysis calculations and results exporting among others. Some examples include: Simulated Distillation Natural Gas Reporting Tool Provides users with the ability to produce customized reports based on GPA/ISO/ASTM natural gas methods and calculations Simulated Distillation Provides boiling point distributions for the full range of petroleum products required to comply with ASTM, DIN, IP and ISO standard test methods Natural Gas Reporting Tool Detailed Hydrocarbon Analysis Automatically reports the physical properties of hydrocarbons based on individual components for applications that comply with ASTM, IP and other standard methods

Benefit from SCION-GC Multi-language User Interface Advanced EFC Capability High Pressure Injection Inert Flow Path Backflush Capability Constant Linear Velocity Mode 600 Hz Data Rate CompassCDS Software SCION 436-GC Small footprint High performance Dual channel architecture SCION 456-GC Solutions platform Total flexibility Four channel architecture

Increased Productivity With over 40 year s experience in gas chromatography, we provide unrivalled expertise in building robust instruments and creating customized solutions that enhance productivity. With complete control of design, manufacture and testing, Scion Instruments is able to guarantee that the quality and technological excellence of its products is of the highest standard. Speed increased by a factor 6.5 Small ID from 0.25 to 0.1mm Short column from 15 to 4 mtr Increased ramp from 10 to 65 ºC/min Data rate from 25 to 200 Hz Fast Cycle Times Reducing the time between injections can considerably improve productivity. The high performance oven incorporates features designed to ensure rapid heating and cooling for maximum productivity. This, in conjunction with high pressure injectors and ultra narrow bore columns significantly reduces analysis cycle times with no loss of performance. IntelliUpdate Instrument and system effects (column ageing, matrix etc.) can cause experimental deviations such as retention time shifts. The CompassCDS IntelliUpdate function can be used to automatically correct and compensate for such deviations. This is accomplished without having to make any changes to instrument control parameters and ensures users obtain consistently accurate results. A) Methane peak eluting at 5.00 minutes automatically identified with associated Halve Peak Width timed event at 4.96 minutes. B) Methane peak eluting 0.1 minutes later due to column deterioration over time with peak no longer identified and timed event missed as software has not compensated. C) IntelliUpdate feature automatically updates peak Retention Time and timed event tables after each run to compensate for peak and timed event migration.

Optimized Switching Valves Flow splitting, backflushing and Deans switching are valuable techniques for improving cycle times, analytical performance and the robustness of GC methods. Backflushing is key to reducing analysis time and column protection and works by reversing column flow once peaks of interest have eluted and been detected. This feature eliminates the need for extended time and temperature segments usually required to elute highly retained components injected with compounds of interest. Reversing the flow elutes these materials out through the injector split vent and has the added benefit of protecting columns from thermal degradation and contamination. Comparison analysis with and without backflush Heart cut using the Deans switch without backflush Deans switching enables the use of multiple traps and columns of differing phases in one method/analysis. It is the basis of two dimensional GC and many standard analyzers manufactured by Scion Instruments. Use our expertise to configure the optimum system for you.

Capability and Automation Scion Instruments offers a detector and injector range that meets virtually all application and market requirements. All come standard with advanced EFC. Whatever the requirement, be it Split/Splitless, Cold-on-Column, Packed, Flash or Programmable Temperature Vaporizing injection, we have the solution. Universal Specific FID TCD PDHID MS ECD NPD (TSD) PFPD Scion instruments offers a complete selection of injectors designed for all applications, column types and dimensions. Injector Selection Guide - Sample/Analysis Characteristics or Requirements Trace Analysis Separation & Speed Sample Capacity Wide Range of Analytes Preferred Column Type 1st Choice 2nd Choice Capillary, 0.53 mm ID Large Volume (LV) Split/Splitless Capillary, 0.1 to 0.53 mm ID Split/Splitless Large Volume (LV) SS Mode Capillary, 0.53 mm ID Large Volume (LV) Capillary, retention gap Cold On-Column Large Volume PTV Mode Capillary, 0.53 mm ID Packed Large Volume (LV) PTV Mode Capillary, 0.53 mm ID Cold On-Column Large Volume (LV) On-Column Mode

Regardless of sample type or throughput, SCION GC s can provide an automated solution to meet your requirements. Three sampler options are available, the CP-8410, CP-8400, and the PAL Combi-XT. Each can be tailored to meet specific sampling needs and workloads. CP-8400 High throughput 100 x 2ml sample capacity Dual/Duplicate Injection SPME CP-8410 Flexibility Accommodates 2, 5, 10 ml vials Low cost/high performance Ease of use PAL Combi-xt High throughput Liquid handling capability SPME ITEX

Scion-Certified Consumables for Your SCION GC Scion GC columns span a broad range of column lengths, diameters, stationary phases, and materials including: Fused Silica (FS) and Inert Steel (IS). Ideal for either routine or research type analyses, Scion GC columns cover a wide range of applications and include: Standard WCOT (Wall Coated Open Tubular) Solid Stationary Phase PLOT (Porous Layer Open Tubular) Inert Steel Micro-Packed and Packed Super Clean Gas Filters Scion Gas Purification Systems have the range to satisfy your needs from individual to combination filters, from Ultra purity combined with Ultra capacity, to all in one solution kits. Innovative features designed into the product yield extensive benefits to the user. Ultra-high capacity for long life, less change and improved productivity High-purity output ensures 99.9999% Pure Gas Quick connect fittings for easy, leak-tight filter changes Glass internals prevent diffusion; plastic externally for safety Easy-to-read indicators for planned maintenance and improved up-time For research use only. Not for use in diagnostic procedures. www.scioninstruments.com www.scioninstruments.com