Residential Detached Garage Handout

Similar documents
RESIDENTIAL DETACHED GARAGE HANDOUT

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Detached Garages and Building Permits. 1 and 2 Family Dwellings

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

POST FRAME BUILDING STANDARDS

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

R Code and Commentary for 2012 NC Residential Code final 03/06/13

Administrative Changes

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

RESIDENTIAL DETACHED STORAGE STRUCTURES (GARAGE)

Temporary Construction Loads Over I-Joist Roofs And Floors

TYPICAL BEARING WALL FRAMING

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

PinkWood Ltd. Revised September 29, 2017

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

2003 International Residential Building Code

GARAGE MAIN FLOOR PLAN SDSCAD Specialized Design Systems

One and Two Family Additions

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Building Guide. Colorado Chapter of the International Code Council

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

Applying for Permits to build a new house in Linn County

14' x 24' Garage Plan

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Chapter 7. Roof Framing

Steps in Building a Shed

RESIDENTIAL BUILDING PLAN REQUIREMENTS

The Inspection Process. Waxhaw N.C.

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

Residential Accessory Structures & Room Additions

Each proposed project will be reviewed for compliance with the following codes as applicable.

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

System Report. Design for Combined Shear and Uplift from Wind. and equipment, and Section Analysis

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

LPI 56 Technical Guide

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Technical Data for. Headers. and Beams

HATFIELD TOWNSHIP DECK/PATIO PERMIT PROCEDURES

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

City Planning & Development - Development Services (CPD-DS) 414 E. 12th Street 5 th Floor Kansas City, Missouri Telephone (816)

Minimum Requirements For One & Two Family Structures FBC 6 th Edition (2017)

Evaluation of Full-Scale House Testing Under Lateral Loading

Joint Evaluation Report ICC-ES (800) (562)

SECTION PLATE CONNECTED WOOD TRUSSES

Residential Decks 1 & 2 Family Dwellings and Townhouses City of Owatonna BUILDING DEPARTMENT

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Formulating a Korea Industrial Standard for light-frame wood construction

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

Hansen Pole Buildings Planning Guide. Toll Free / Toll Free FAX

Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc.

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

Structural Inspection

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT Prepared for: Boca Vista Condominium Association, Inc th Avenue Madeira Beach, FL 33708

Inspection of New One- and Two- Family Dwellings

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

2.2E Parallam PSL Deep Beam

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

Department of Building and Zoning Deck Handout for ONE AND TWO FAMILY CONSTRUCTION

LP SmartSide Strand Substrate Treated-Engineered-Wood Lap & Panel Siding Louisiana-Pacific Corporation Revised December 2, 2016

Wood Frame Construction Manual for One- and Two-Family Dwellings 2015 EDITION WORKBOOK

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

FACT SHEET #2 DECK INFORMATION

Table of Contents. Page Title

Residential Building Permit Application

COVERED AND SCREENED PORCHES: WHAT YOU NEED TO KNOW

2.2E Parallam PSL Deep Beam

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

Neighborhood Traditional Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

Table R (1) Allowable Spans and Loads for Wood Structural Panels for Roof and Subfloor. Sheathing and Combination Subfloor Underlayment

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems

PRESENTATION OUTLINE MUBEC & IRC APPLICABILITY & ADMIN. 6/17/2015 RESIDENTIAL STRUCTURAL SYSTEMS. Carmen B. Bombeke, P.E.

Typical Deck Details

FENCES. This hand out is for REFERENCE ONLY. For more details see specific code sections.

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

MBOIA IRC Wall Bracing. Mark Halverson. Maine Building Officials and Inspectors Association. First Last

Introducing TJ Insulated Structural Framing Components

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

PR-L274 Nordic Structures Revised April 16, 2017

ILLUSTRATED GUIDE. For Seismic Design of Houses. Lateral Bracing Requirements Part 9 BC Building Code 2012

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised May 30, 2013

Prescriptive Residential Wood Deck Construction Guide Based on the 2012 International Residential Code

4 EXTREME FOUNDATION PANELS

CITY OF ST. PETERSBURG PLANNING & ECONOMIC DEVELOPMENT DEPT

Maximum Spans Southern Pine Joists & Rafters

Residential Floor & Roof Systems Product Guide

Larchmont Zoning Code: DRAFT Revisions, with Recommended Changes from the Planning Commission April 15, 2003

Transcription:

Residential Detached Garage Handout Getting Started 1. Please read this handout in its entirety. If you have specific questions after reading the handout, please contact the Altoona Building Department at 515-967-5138 Ext. 4. This handout cannot cover every possible scenario. Please visit with Building Department staff if the proposed garage construction differs from this handout. 2. If you plan on constructing a detached garage, and the project meets the requirements within the handout, please obtain and fill out a building permit application. The permits are available on our website at www.altoona-iowa.com. Navigate to Departments > Community Development > Building. They can also be picked up at the Building Department, located at 1504 8 th Street SW. A building permit must be issued before any inspections can be scheduled and before any work can begin. The majority of detached garage applications are processed with little delay. 3. A site plan shall be provided at the time the building permit application is submitted. Building permit applications submitted without a complete site plan will not be accepted for review. The site plan shall be drawn on a minimum of 8 ½ x 11 paper and shall be as close to scale as possible. Please make sure that the site plan is from an overhead / aerial view. You may obtain an aerial photo of your lot from the Polk County Assessor s website, located at www.assess.co.polk.ia.us. The site plan shall include, but not be limited to indicating: Any easements; the distances from the proposed detached garage to the lot lines; the size and location of the proposed detached garage; the distance between the detached garage and the dwelling, including any adjacent roofed decks/porches; and the location of all structures on the lot, including sheds, gazebos, play houses, etc. 4. Complete and submit the sheet labeled Wall Bracing, located on the last page of this handout. 5. The following inspections are required during the project: A footing/foundation inspection prior to pouring concrete; a framing rough-in inspection and a final inspection once all work is complete. The garage shall not be used until all inspections are approved and signed off. Note: Electrical, mechanical, and plumbing work are not required to be installed; however, certain requirements, separate permits, and inspections will be required, if installed. 6. Note: Confirming property lines, buried utilities, easements, restrictive covenants or association requirements is strictly the responsibility of the owner and/or contractor. Prior to the placement of a detached garage, please check all covenants to verify the size, type, and intended materials are acceptable and allowed for your property.

General Zoning Regulations Questions and Answers 1. Q: What is the definition of a detached residential private garage? A: A structure which is detached and accessory to a residential building and which is used for the parking and storage of vehicles owned and operated by the residents thereof and which is not a separate commercial enterprise available to the general public. Most accessory buildings, including sheds that are over 160 square feet, will be defined as detached garages. 2. Q: What zoning districts allow detached garages to be installed? A: This handout applies to detached residential private garages that serve single family dwellings located in zoning districts A-1, R-1, and R-4, and single and two-family dwellings located in zoning districts R-2, R- 3, and R-5. Note: Detached garages located in an R-4 district will need to be individually reviewed, since certain restrictions apply. 3. Q: Can a detached garage be built on a lot before the principal dwelling unit is built? A: No. The principal structure, such as the single family dwelling, is required to be built first. 4. Q: How many detached garages are allowed per lot? A: Only one detached garage is allowed per lot. 5. Q: Can the detached garage be built anywhere on the lot? A: No. The detached garage shall be placed only in the rear yard. See the attached sheet labeled Location of Rear Yard. 6. Q: Is there a limit as to how bit a detached garage can be? A: Yes. The maximum allowable building area is 1,000 square feet. 7. Q: Is there a minimum distance that is required between a detached garage and the single family dwelling? A: Yes. The minimum distance between finished outside wall dimensions is 6. Note: If in an R-4 zoning district, the minimum distance is 4. 8. Q: Is there a limit to the amount of rear yard that a detached garage and other accessory structures can occupy? A: Yes. The total of all accessory structures within the rear yard, such as detached garages, sheds, gazebos, playhouses, etc. shall not occupy more than 30% of the rear yard. 9. Q: Is the height limited for detached garages? A: Yes. The height shall not exceed 14. See sheet How Roof Height is Measured. 10. Q: How many stories can a detached garage have? A: Only one story is allowed. 11. Q: Are there any regulations regarding the type of material used to build a detached garage? A: Yes. Detached garages shall be constructed of materials that are the same or similar to the principal dwelling. 12. Q: Is there a minimum distance off the property lines that a detached garage has to be placed to meet zoning? A: Yes. A minimum of 3 from lot lines to the garage s wall line, but in no case shall any portion of the detached garage, including overhang, be placed into an easement. See sheet Roof and Ceiling Construction and Exterior Walls Located Less Than 5 to the Property Line for additional requirements. 13. Q: Is there a minimum distance the detached garage has to be from other detached accessory structures, such as sheds, gazebos, playhouses, etc.? A: No. As long as they are physically and visually separated, there is no minimum distance required. 14. Q: On a corner lot, what is considered a rear yard? A: See sheet Location of Rear Yard. 15. Q: On lots that have streets both in the front and the rear of the property, which is considered the rear yard? A: See sheet Location of Rear Yard. Altoona has special requirements for double frontage lots for subdivision plats or plat of surveys recorded after February 7, 2003. 16. Q: Can more than one approach (driveway entrance) be installed to access the garage? A: Corner lots may be eligible for a maximum of two approaches, one from each street. Each project needs to be individually reviewed.

Location of Rear Yard Typical Non-Corner Lot Typical Corner Lot Neighbor Lot ~ ~/ Location of Rear Yard Side Yard Dwelling.c.c Ow Side Yard 0 0...J 0> z ~ ~ U5 Q) 'E ro >- C o U:: ~ Dwelling Side Yard Front Yard Front Yard Street Street I Typical Non-Corner Through Lot (Altoona only).c., ro 0> Major Street or Highway Min 18' From Prop Line t I Location OwZ...J 0 ~c 0 U5 Q)>- 'E Dwelling Typical Corner Through Lot (Altoona only) Major Street or Highway U:: of Rear Yard Z0>.c Ow Min 18' From Prop Line t 0.c z Ow.c0> 0 I % Side Yard 0...J ~/ ~~m~ ~. / Location of Rear Yard Dwelling Side Yard Front Yard Front Yard Street Street

How Roof Height is Measured Note: For other than the gambrel roof style at the bottom of the page, roof height is measured from the surrounding adjacent grade to the mean of the roof. Mean is measured from the midpoint between the peak of the roof and the top of the wall. 14' Maximum, Gable Style Roof 14' Maximum, Shed Style Roof 14' Maximum, Hip Style Roof 14' Maximum! Gambrel Style Roof

Footing and Foundation 1. Footings serving detached garages that are over 160 square feet shall be constructed per the details provided. 2. All organic material such as grass, roots, etc. must be removed from the area where the concrete is to be placed. Where backfill for sub-grade is required, a permeable and granular material shall be used and compacted. 3. The strength of the concrete shall not be less than 3,000 p.s.i. The concrete shall be air entrained. The total air content shall be not less than 5% or more than 7%. 4. J-bolts shall be installed around the perimeter during the pour of the footing. The J-bolts shall be at least ~" in diameter. Typically, a 10" long J- bolt will be sufficient to allow for the minimum 7" embedment and allow 3" for the bottom plate, galvanized washer and galvanized nut connections. J-bolts shall be spaced within 12" from each corner, 12" from any opening, 12" from where two bottom plates butt into each other, and a maximum of 6' on center thereafter. Note: Each plate shall have at least two bolts installed. Minimum of 6" required between bottom of siding and final grade including sod. The slab floor shall contain #4 (Ii" diameter) reinforcing bars 24" on center front-to-back and side-to-side (or) 6" x 6" wire reinforcing mesh. Reinforcement shall be in place and tied off for the inspection. The slab shall be a minimum of 4" thick. The slab and thickened perimeter shall be one continuous pour. -I:} I:} / The perimeter footing is required to be a minimum of 10" in width and a minimum 16" in height. Note: If there is more than 24" of exposed foundation wall measured between the top of final grade and the top of the slab, then the footing may have to extend into the ground a certain distance for lateral support. Please communicate with city staff if your project fits this description. The perimeter footing shall contain two - #4 rebar (~" diameter). One shall be placed near the top and one near the bottom continuously with the ends of the rebar overlapping each other at least 15". These shall be in place and tied off for the inspection.

Wall Envelope 1. The finished ceiling height shall not be less than 7'-0". 2. The bottom plate shall be at least a 2" x 4" and shall be treated lumber. 3. The wall framing needs to be a minimum of 2" x 4" stud construction and shall not exceed 10' in height. The studs shall be a minimum #3, standard or stud grade lumber. 4. The stud spacing shall be 16" maximum on center. The connection between the studs and the top and bottom plates shall be made with 2-16d nails. Nails used to connect into the treated bottom plate shall be properly coated to prevent corrosion. 5. A double top plate shall be used to tie the walls together. This double top plate shall be nailed to the top plate using 2-1Od nails every 24" on center around the entire perimeter. Where double top plates tie the corners together, they shall be at least 24" long. These two plates shall have joint offsets of at least 24". 6. The exterior wall sheeting shall consist of a minimum of 7/16" x 4' x 8' approved wall panel. Plywood/osb wall sheeting shall be face nailed to the studs by not less than 6d common nails at 6" around the perimeter of the panel and not less than 12" in the field (or) face nailed to the studs by staples that are at least 15 ga. (1-0/."long) at 4" around the perimeter of the panel and not less than 8" in the field. By code a certain percentage of each exterior wall is required to be properly braced. In most cases, the whole exterior wall line will be required to h<;ivecontinuously sheeted structural wall panels such as o.s.b. or plywood installed in order to meet wall bracing requirements. See the "Wall Bracing" section within this handout to properly calculate the correct required amount of wall bracing. 7. Prior to installing the siding, obtain information from the siding company to see if a weather resistive barrier (building wrap) is required to be applied between the siding and the sheeting. Most vinyl sidings and cement board sidings will require a building wrap. Nailing and sealing of the exterior siding and envelope in general shall be per the manufacturer's instructions. 8. If windows are to be placed within the garage, safety glazing may apply. Typically, if windows are installed more than 24" away from pedestrian doors and are at least 18" above the finished floor they will not be required to be safety glazed. Please contact the inspector assigned to your area if in doubt. 9. For header sizing see "Minimum Header Sizing Based On Eave to Ridge Distance and Opening Width". 1O. If the exterior wall is less than 5' to the property line see "Exterior Walls Less Than 5' to the Property Line". The walls will need to be of fire resistive rated construction.

Roof and Ceiling Construction Using Engineered Roof Trusses 1. Most roofs today are being designed and built using manufactured trusses. At a minimum, the live load for the trusses shall be designed for 30# per square foot. Additionally, the dead load will need to be designed based on the weight of the construction materials used for the roof. This is typically around 10# per square foot. If you plan on using the attic area for storage. the lumberyard will need to know so that they can increase the loading as required. The overall roof load will need to be designed for the total live and dead loads of the roof. For proper installation of the trusses, the manufacturer shall provide a job site installation guide and design sheet which shall include, but not be limited to, the live and dead loads, bracing requirements, bearing locations, truss manufacturer's name and contact information, etc. This paperwork is required to be on site during the framing rough. The construction of onsite built trusses will not be acceptable. 2. Roof trusses shall not span greater than 24" on center and the pitch shall be at least a 3/12. 3. Each truss shall be connected to the double top plate with approved fasteners such as a Simpson Strong tie (H1) or (H2.5) clip (or) a USP Structural Connector (RT7) or (RT15) clip. The size and amount of nails used to make the connections shall be as required by the manufacturer and are usually stamped on the fastener. Other connectors may work, but pre-approval is required. 4. The maximum roof overhang is 24". Note: In no case shall the end of the overhang extend any closer than 12" to the property line nor shall it extend into any easement. 5. Roof sheeting shall consist of a minimum of 7/16" x 4' x 8' osb or plywood panels installed with the 8' length perpendicular to the trusses. The panels shall be face nailed to the top ouhe trusses with 8d nails at 6" around the perimeter and 12" within the field (or) by 15 ga. staples (1-%") at 4" around the perimeter and 8" within the field. Most manufacturers require an 1/8" gap between joints to allow for contraction/expansion. Plywood clips/spacers can be used to help maintain this gap and they can help support the plywood span between trusses. 6. If the roof construction is not manufactured trusses, go to the "Rafter. Ceiling Joist. Collar Tie and Ridge" section in this handout.

Roof and Ceiling Construction - (Stick Framed) Using Rafters, Ceiling Joists, Collar Ties and Ridge RIDGE RAFTER COLLAR TIE CEILING JOIST t----l BUILDING SPAN RAFTER SEAT CUT 1. Roofs may be designed on site if they are built per the requirements listed herein. The requirements are intended to cover roofs with a pitch of 3/12 and greater. 2. The ridge board serving both common rafters, hip rafters and valley rafters shall be at least one inch nominal thickness and at least as wide as the cut end of the rafters. 3. The rafters shall be connected to the ridge board by either toe nailing 4-16d nails (or) face nailing 3-16d nails. Hip or valley rafters shall be nailed to the rafters with the same nailing pattern. 4. The rafters shall be connected to the double top plate by toe nailing 2-16d nails as well as approved fasteners such as a Simpson Strongtie (H1) or (H2.5) clip (or) a USP Structural Connector (RT7) or (RT15) clip with approved nails. 5. The rafter's plumb cut shall be 1- Y:," deep. The rafter's seat cut cut shall extend the full width of the double top plate, typically 3- y:'''. Cuts made deeper than mentioned may not pass inspection. 6. Ceiling joists shall be connected to the rafters by face nailing 3-10d nails. They shall connect to the double top plate by toe nailing 2-16d nails. Each rafter shall have a ceiling ioist properly attached to it. 7. Collar ties are required to be installed in the upper 1/3 of the attic. They shall consist of minimum 1" x 4" material, be installed not to exceed 48" on center and be face nailed to.the rafters with 3-10d nails. 8. The maximum roof overhang is 24". Note: In no case shall the end of the overhang extend any closer than 12" to the property line and it shall not extend into any easements. See other parts of this handout for more specific details. 9. Roof sheeting shall consist of a minimum of 7/16" x 4' x 8' for rafters spaced 24" o.c. and 7/16" x 4' x 8' for rafters spaced 16" O.C. and consist of osb or plywood panels installed with the 8' length perpendicular to the trusses. The panels shall be face nailed to the top of the rafters with 8d nails at 6" around the perimeter and 12" within the field (or) by 15 ga. staples (1-Y-") at 4" around the perimeter and 8" within the field. Most manufactures require an 1/8" gap between joints to allow for contraction/ expansion. Plywood clips/spacers can be used to help maintain this gap and they can help support the plywood span between trusses. 1O. Note: If the roof construction is not designed using rafters and ceiling joists, please refer to the "Using Engineered Roof Trusses" section in this handout.. BUILDING I RECOMMENDED ALLOWABLE SPANS - RAFTERS AND CEILING JOIST RAFTERS 2" CEILING X6" 2" @ 8" x 24" X 16" RAFTERS 10" 8" JOISTS O.C. SPAN Notes: 1. Wood shall be #2 Doug-fir-Iarch or #2 Spruce-pine-fir or better. 2. Assuming ceilings not applied to the bottom of the rafters, such as sheetrock. 3. Assuming attics are uninhabitable and without storage. 4. As~uming ceiling joists will not have sheetrock or similar installed. 5. Building spans greater than 25' will need to be designed by a licensed structural engineer that is registered with the state of Iowa. Two sets of signed and stamped plans shall be submitted for review along with structural calculations.

Exterior Walls Located Less Than 5' to the Property Line ~I Property Line I One-hour rated wall ~ There shall be at least 12" from the property line and end of the overhang. The maximum overhang allowed is 24". 1. In order for the garage to be placed closer than 5' to the property line, the zoning must allow it. See "General Zoning Regulations" in this handout. If so, this detail for a one-hour rated construction would apply. 2. An inspection of this fire rated construction is requ ired once the garage is framed and the exterior grade sheetrock is in place on the exterior side. The inspector will need to see the fastening of the sheetrock to make sure that the joints of the sheetrock are butted tight to each other prior to it being covered with building wrap and siding. 3. The wall shall consist of the following: One layer of 5/8" type X gypsum sheetrock applied parallel or at right angles to the studs on each side of the 2 x 4 wall. The studs shall be spaced at 16" on center. The screws to connect the sheetrock to the studs shall be 1-X" type W sheetrock screws installed at 12" on center. The edges of the sheetrock shall be butted tight to each other. The joints of the sheetrock shall be staggered 16" apart on opposite sides of the wall. 4. As shown in the detail, the roof is running perpendicular to the fire rated wall and the fire rated wall shall terminate at the top ~ Approved building wrap required between siding and exterior grade sheetrock. If zoning allows the distance to be less than 5' from property line to the wall line, then a onehour rated wall shall be constructed per this handout. plate. If the roof above the fire rated wall runs parallel to the wall (gable end above wall), then the fire rated wall shall continue up this gable end and the sheetrock shall extend on each side of this gable and terminate at the bottom of the roof sheeting. The framing members for the gable end shall not exceed 16" on center. 5. Openings such as doors and windows are allowed within these fire rated walls. These openings do not have to be protected, but are limited to 25% of the overall area of the wall. 6. See other parts of this handout for the maximum length of the overhang. In no case shall the overhang be closer than 12" to the property line. 7. NOTE: No part of any overhang shall be allowed to extend into an easement. 8. NOTE: If the exterior walls require minimum 7/16" continuous osb on the exterior walls, per the "Wall Bracing" section, then the osb shall be installed over the sheetrock. The nails used to secure the osb throug h the sheetrock and into the wall studs shall be 8d common.

Opening Width Minimum Header Sizing Based On Eave to Ridge Distance and Opening Width Eave to Ridge Distance for Load Bearing Headers (Includes up to 2' overhang) See Example Below 18' 12' 10' 14' 16' 3-2 x 2 2-2x10 2-2x12-23 11-7/8 (or) -(0 -- 2 2-2x42-2x6 x2 810-3 2-2x10 2-16 2-2x12 2-18LVL 4 9-2-2x6 2-2x8 7- -11-7/8 (or) - -Y. 2 2 -LVL x 14 2 LVL 10 12 -- 9-Y. LVL 7-Y. 11-7/8 (or) LVL 2 - - LVL 9-Y. 7-9-'12 Y. LVL Notes: 1. Headers that are over 7' long will need to have two jack studs installed under each end of the header. 2. If the eave to ridge distance is over 18', then engineering is required. 3. Opening widths larger than 16' wide will need to be individually reviewed. Paperwork shall be submitted and engineering may be required. 4. Wood is assumed to be Douglas fir-larch or hem-fir and grade #2 or better for other than engineered LVL headers. 5. The header sizes are assuming there is no or very limited storage in the attic. 6. If using engineered products for headers (LVL), please have a copy of the paperwork on the job site. The paperwork should show the allowable spans. If paperwork indicates different spans, the paperwork will override the above chart. The LVL headers in the chart have a minimum (E) factor of 1.9 and a minimum (Fb) value of 2,600 psi. Please check manufacture's paperwork to verify the proposed headers meet these requirements. 7. Each piece of header shall be nailed together by the use of 10d nails (3" x 0.128"). The ends shall have nails at the top and bottom. The headers shall be nailed every 16" on center thereafter with fasteners at the top and the bottom. 8. Spacers used between headers to build them out to the wall width shall be at least 7/16" thick and shall consist of plywood, o.s.b. or other approved material. 9. Non-load bearing headers for 8' garage doors shall be at least 2" x 8" material and non-load bearing headers for 16' garage doors shall be at least 2" x 12" material. The material shall be Douglas fir-larch or hem-fir and grade #2 or better. A solid sheet of 7/16" osb shall be installed between the header for structural strength. The osb shall shall act as one continuous spacer and any joints in the osb shall butt tight to each other prior to being nailed to the header. Non-load bearing headers for 18' garage doors shall be at least 1-0/...LVL engineered lumber. LVL headers used in non-load bearing applications will not require the structural osb spacer. Load Bearing Wall Eave to Ridge Distance ~-----------~ ~eader Locationl Opening Width

B U I L D E R T I P S APA Narrow Wall Bracing Method Framing Tips The APA Narrow Wall Bracing Method is a simple, site-built solution that allows builders to construct segments as narrow as 16 inches next to window and door openings. Be sure to check for these essential details when constructing the APA Narrow Wall Bracing Method around garage openings. For complete information on the APA Narrow Wall Bracing method and its applications in locations other than the garage, please see APA publication Narrow Walls That Work, Form D420. Wall sheathing must extend up over header OR Wall sheathing must extend up over header XTERIOR VIEW OF GARAGE OPENING Nail schedule 8d common at 3" o.c. Sheathing joint at approx. mid height Nail schedule 8d 8d common at at 3" 3" o.c. and at sheathing joint APA THE ENGINEERED WOOD ASSOCIATION

2006 APA THE ENGINEERED WOOD ASSOCIATION ALL RIGHTS RESERVED. ANY COPYING, MODIFICATION, DISTRIBUTION OR OTHER USE OF THIS PUBLICATION OTHER THAN AS EXPRESSLY AUTHORIZED BY APA IS PROHIBITED BY THE U.S. COPYRIGHT LAWS. Install 1000-lb strap Nail corner studs together 8d at 6" o.c. 2 rows of 16d at 24" o.c. 8d at 3" o.c. (PLAN VIEW OF CORNER DETAIL) Nail top plate to header with two rows of 16d nails at 3" o.c. Stud optional to support interior finish We have field representatives in many major U.S. cities and in Canada who can help answer questions involving APA trademarked products. For additional assistance in specifying engineered wood products, contact us: APA THE ENGINEERED WOOD ASSOCIATION HEADQUARTERS 7011 So. 19th St. Tacoma, Washington 98466 (253) 565-6600 Fax: (253) 565-7265 PRODUCT SUPPORT HELP DESK (253) 620-7400 E-mail Address: help@apawood.org Form No. F435 Issued January 2006/0010 Gypsum optional INTERIOR VIEW OF GARAGE OPENING 2 anchor bolts with min. 2" x 2" x 3/16" plate washers Extend header to king stud DISCLAIMER The information contained herein is based on APA The Engineered Wood Association s continuing programs of laboratory testing, product research, and comprehensive field experience. Neither APA, nor its members make any warranty, expressed or implied, or assume any legal liability or responsibility for the use, application of, and/or reference to opinions, findings, conclusions, or recommendations included in this publication. Consult your local jurisdiction or design professional to assure compliance with code, construction, and performance requirements. Because APA has no control over quality of workmanship or the conditions under which engineered wood products are used, it cannot accept responsibility for product performance or designs as actually constructed. APA THE ENGINEERED WOOD ASSOCIATION

PORTAL FRAMING REQUIREMENTS

Wall Bracing NOTE: Please detach. fill out and submit this sheet with the buildina permit application. NAME.PROJECT ADDRESS: CITY _ Steps to Ensure That Exterior Wall Bracing is Met 1. Will ml exterior walls of the garage have a minimum 7/16" continuous structural o.s.b. sheething installed? YES or NO If no, please explain type of wall sheething proposed. (Note: Other types may not be allowed based on wall openings, etc.) 2. What will the wall height be from the top of foundation to the garage's top plate? (Ex. 8', g' or 10') 3. Has the BLANK DRAWING below been filled out with the correct information? Insufficient submittals may delay the permit process. a. The overall length of each exterior wall shall be shown. b. The location of all windows and doors shall be shown. c. The width and height of all windows and doors shall be shown. d. The distance that each window or door rough opening starts measured from the outside corner of the garage shall be shown. 20' BLANK DRAWING: Please draw the proposed qaraqe below. 7/16" continuous sheething 8' high walls APPROVED SAMPLE 2' 16'w x Th door 2' Note: Minimum wall widths are required next to the overhead doors and they are based on wall height. If the following widths are not met next to the overhead door, engineering may be required: 8' walls need to be at least 24" wide g' walls need to be at least 27" long 10' walls need to be at least 30" long Staff Use: If item #1 is not answered "YES", the below items need to be reviewed and met: a. Verify that walls on each side of the overhead door have an approved wall braced panel that is 4' long (or) the walls are properly portal framed with an extended header that is at least 16" long per approved APA detail. (Detail not in this handout.) b. Verify that a wall braced panel starts within 12.5' from the outside corner of the garage. c. Verify that the wall braced panels do not exceed 25' on center. d. Verify that each exterior wall has at least 16% of the exterior wall braced. Approved/ Comments: _