The Carport - Bryan, Texas

Similar documents
POST FRAME BUILDING STANDARDS

LPI 56 Technical Guide

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

R Code and Commentary for 2012 NC Residential Code final 03/06/13

Administrative Changes

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

Lateral load basics Code acceptance of Standard. Standard Overview 2008 Wind & Seismic Standard. Wind. Wind Load Path. IBC Section 1604.

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

FACT SHEET #2 DECK INFORMATION

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

System Report. Design for Combined Shear and Uplift from Wind. and equipment, and Section Analysis

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

hurricane resilient wooden houses safer building and retrofitting guidelines

LVL Portal Frame Design. Warwick Banks Technical Manager

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

Appendix I ESTIMATED DESIGN WIND PRESSURE AND STRENGTHS OF CONNECTIONS OF JOPLIN HOME DEPOT BUILDING

SECTION PLATE CONNECTED WOOD TRUSSES

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

Structural Redesign Gravity System

DESIGNING WITH STEEL FORM DECK

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

LAMINATED VENEER LUMBER

Lintel Tables Design Notes and Limitations

Lateral Design of Mid- Rise Wood Structures

Nabil A. Rahman, Ph.D., P.E.

Types Of Roofs - Vault

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

Figure 1 Shear wall segments with mono-sloped top plates

PRESENTATION OUTLINE MUBEC & IRC APPLICABILITY & ADMIN. 6/17/2015 RESIDENTIAL STRUCTURAL SYSTEMS. Carmen B. Bombeke, P.E.

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

SHEAR BRACE. Featuring ilevel Shear Braces for Engineered and Prescriptive Applications iLevel8 (

4 EXTREME FOUNDATION PANELS

DESIGN CRITERIA. Allowable Stress Design (ASD) AISC-1999.

Cantilevered Rail System

FORMDECK. constructions. constructions

LIFE SCIENCES BUILDING STRUCTURAL CONCEPTS AND EXISTING CONDITIONS

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

WOOD I BEAM JOISTS PAGE 4 GEORGIA-PACIFIC WOOD PRODUCTS APR 2015 ENGINEERED LUMBER RESIDENTIAL GUIDE

Building Guide. Colorado Chapter of the International Code Council

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

ARCH 614 Note Set 12.1 S2014abn

xiii Preface to the Fifth Edition Preface to the Second Edition Factors for Conversion to SI Units of

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

Structural Inspection

MAX-CORE I-JOIST DESIGN MANUAL-US

one structural behavior, systems and design Course Description Course Description Syllabus & Student Understandings statics mechanics of materials

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Kiski Area High School Allegheny Township, PA FLOOR SYSTEM ANALYSIS

DETAIL DRAWINGS. RASTRA is a stay-in-place insulated concrete. form that is structurally strong, energy-efficient,

Maximum Spans Southern Pine Joists & Rafters

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

This tip sheet may be used as a guide for single-family residential uncovered deck permits.

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Uniform Mitigation Verification Inspection Form Maintain a copy of this form with insurance policy

Special Inspections for Wood Construction BCD710 Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

MAT109: Introduction to the Wood Frame Construction Manual

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

Tables with Allowable ASD Seismic Values For Design at R = 6.5. Special Moment Frame MF1-12

How to Construct a Feral Enclosure

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

PHOTO 1: View from Inside the Structure. Note the Rotation of the WSP, Failure at the Lower Leading Edge and Deformation of the Top Plate

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

Individual Truss Marking Is it a Building Code Requirement?

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

ATI Evaluation Service A Division of Architectural Testing Certification Services

Installation Guide and Safety Manual

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Including RedForm LVL, RedForm-I65, I90 and I90H Joists. Lightweight for Fast Installation. Compatible with Standard Framing

Understanding Wind Uplift Ratings

Residential, 26 Ga. Roof Panel over 15/32 Plywood. Florida Product Approval # R3 Florida Building Code 2017 Per Rule 61G20-3 Method: 1 D

Resilient Design Guide HIGH WIND WOOD FRAME CONSTRUCTION EDITION

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

2) Open ConstructionCalc ProBeam from Microsoft Excel, then File Open. 3) Part 1 General Input.

Aluminum Beam Gang System

Overturning Forces. 12 times 300 lbs = 3,600 lbs of shear force along top of wall. Shear Wall

2003 International Residential Building Code

Title: Building Construction for the Fire Service. Time: 3 hours. Teaching Materials: White board Building Construction for the Fire Service (PDF)

Technical Data for. Headers. and Beams

SHEET METAL ROOF TEST REPORT

PREFABRICATED STEEL TRUSS SPECIFICATIONS

ES230 Strength of Materials Exam 6 - Compilation Prof. Kurtz, ES230 STRENGTH OF MATERIALS Exam 6 Wednesday, April 26, 2017, 7pm

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

Free standing Patio covers

USING WOOD STRUCTURAL PANELS FOR SHEAR AND WIND UPLIFT APPLICATIONS

FLORIDA PHOTOVOLTAIC BUILDINGS PROGRAM

City of Port Orange Adult Activity Center Remodeling SSA Project No Volusia County, Florida October 8, 2009

WHAT IS CANTILEVER RACK?

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

CHAPTER 8 THE DESIGN AND ANALYSIS OF MULTI-STORY BUILDINGS WITH LARGE MOMENT END-PLATE CONNECTIONS 8.1 INTRODUCTION

Transcription:

This is going to be an exciting presentation that is of great interest to me. The carport of my house was rotten and falling down and needed to be replaced. I m going to give you all the information you will need to analyze a carport of your own and rebuild a new one that will properly shade your cars and not be blown away by wind, or rot from exposure. I m Gavin Daniels.this is my story.

16-0 10-0 ROTTEN!! Existing Carport Analysis The existing carport was a one way structure. The structure consisted of 6 5 dia columns with 4 x 6 beams spliced together across the 10 wide bays. The beams supported 2 x 6, 20 long joists with 1 x 6 decking and a sheet metal rolled roof. Over the 30+ years since it s initial construction lack of maintenance and an initial roof slope of 1 in 3 the carport began to leak. Years of rotting have rendered repair impossible, the only structural members still intact are the columns which show no signs of structural problems.

Steel Columns embedded in concrete still in good condition Rotten wood Metal Straps prevented uplift on the structure Existing Carport Analysis

Code Enforcement No permit required for demolition A permit is required for new construction Sources http://www.bryantx.org/div_buildingservices/codes.htm International Residential Building Code 2000 Materials Three 4x6 beams spanning the three bays was effective before and is well within the requirements of IRBC. The IRBC allows 2x6 joists to span 16 as long as they are spaced less than 24 apart. Initially 3/8 plywood decking was going to be used on top of the joists. I determined the deflection would be excessive during construction and provide undo torsional stress on the joists. The 3/8 thick plywood would not have provided enough material for the metal roof to attach to either. IRBC also recommended having at least ¾ of material to fasten the roof covering to. 1x4 s placed 12 o.c. were used in lieu of the plywood. They would be more rigid and by using two nails at each 2x6 also help control lateral deformation of the 2x6 s 3/8 plywood Live Load Deflection 2x6 rotation about centroid Codes & Materials

3 second gusts of 100+ mph wind must be withstood by the carport. There are no walls on the carport so, wind will create minimal lateral load on the carport (columns). The slope of the roof is 12 in 16. This will encourage the uplift wind will surely produce on the carport. These forces must be counteracted through the use of proper fasteners and structural attachments. Wind Uplift

The rafters on one end were placed on top of the 4x6 beam to increase the slope of the structure and encourage water flow off the roof. The hurricane straps used at this end were designed to withstand the high winds that are known to pass through this area. These winds would cause an uplift on the structure. When properly installed these ties can resist about 1,000 lbs of uplift. The straps are securely fastened with the manufacturer s recommended nails. Hurricane Ties

The joist hangers on the opposite end of the Hurricane Ties serve two purposes. They support the dead load of the 2x6, 1x4 s and metal deck. They are also capable of resisting an upload of almost 1,000 lbs. This is well over any predicted worst case upload for this area and when paired with the hurricane ties assures the structure will remain intact during a storm. Joist Hangers

The metal ties and joist hangers could hold 1,000 s of pound, but without the proper fasteners, they would be useless. 1.5 galvanized nails were used to attach the hangers per manufacturer s recommendation. So now I was sure the 2x6 s would not come loose. To ensure the 1x4 s would stay in place during extreme uplift situations I used two 1.5 ribbed galvanized roofing nails at each overlap of 1x4 and 2x6. The IRBC recommends that metal roof decking be fastened every 36 into at least ¾ of decking. I used 1.5 ribbed galvanized roofing nails with a neoprene washer around the head and fastened them in three evenly spaced runs every 24 along the length of the metal sheet. The 4x6 beams are fastened to a metal plate welded to the top of each column. A ½ x 7 lag bolt was used for this with a ¾ washer at both ends. Fasteners

400+ lbs 2x6 s; 100 lbs 1x4 s & Mtl Deck = 500+ lbs Total Distributed Dead Load 83.33 lbs 166.67 lbs 166.67 lbs 83.33 lbs Loads

Fixed Fixed Fixed Fixed SHEER DIAGRAM MOMENT DIAGRAM Sheer & Moment

The metal deck acts like a folded plate and adds rigidity and stiffness to the structure. During installation and any future live loads on top of the carport, the metal deck will serve to distribute the weight of the live load. As it moves across the carport. The metal deck is placed in overlapping sheets. In the long direction of the sheets, they are over-lapped 4, in the short direction the are overlapped two ridges. The four foot overlap decision was a purely constructability decision, The 8 long, free, metal sheets dictated more than two sheets would be necessary to properly span the 16 width of the carport. It was determined enough sheets were available to place three sheets every 24 along the 30 length of the carport. Therefore the need to cut rusty metal sheets was eliminated. The metal deck also keep the rain off the structure and my truck! Folded Metal Plate

I am quite certain that were my truck to run into a column, the column would win. The column is fixed at the ground and pinned at the top (K=0.7). The deflection of the columns under an extreme lateral load is shown above in red. Let s hope this never happens! Columns Under Lateral Load (My Truck)

In conclusion, the carport was built and it hasn t fallen down. Special thanks to my Dad for his help during the construction of the carport. He s a badass!