Why Decks Fail Design and New PA UCC Requirements to Improve Safety

Similar documents
The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

FACT SHEET #2 DECK INFORMATION

CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.

Prescriptive Residential Wood Deck Construction Guide Based on the 2012 International Residential Code

This tip sheet may be used as a guide for single-family residential uncovered deck permits.

Residential Wood Deck Design

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

ATI Evaluation Service A Division of Architectural Testing Certification Services

CITY OF BRISTOL DECK CONSTRUCTION GUIDE ACCORDING TO THE 2012 IRC WITH THE 2016 CT AMMENDMENTS

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems

Department of Building and Zoning Deck Handout for ONE AND TWO FAMILY CONSTRUCTION

Typical Deck Details

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

Residential Decks 1 & 2 Family Dwellings and Townhouses City of Owatonna BUILDING DEPARTMENT

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Technical Data for. Headers. and Beams

Decks. SPS (1) SPS (2) AKA Appendix B & C

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

POST FRAME BUILDING STANDARDS

Code Compliance Research Report CCRR-0137

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Code Compliance Research Report CCRR-0101

General Requirements Yes N/A 1. Is the designer qualified for the proposed work?

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

Code Compliance Research Report CCRR-0194

LPI 56 Technical Guide

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Maximum Spans Southern Pine Joists & Rafters

LAMINATED VENEER LUMBER

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Tested Guardrail Post Connections for Residential Decks By Joseph Loferski, Dustin Albright, and Frank Woeste, Ph.D., P.E. Copyright.

Frost Protected Shallow Foundations in PA

CH. 9 WOOD CONSTRUCTION

2.2E Parallam PSL Deep Beam

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

ATI Evaluation Service A Division of Architectural Testing Certification Services

SECTION PLATE CONNECTED WOOD TRUSSES

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

ESR-1461 Reissued February 1, 2014 This report is subject to renewal March 1, 2015.

REPORT HOLDER: MASTER MARK PLASTICS PRODUCTS 210 AMPE DRIVE PAYNESVILLE, MINNESOTA EVALUATION SUBJECT:

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

ATI Evaluation Service A Division of Architectural Testing Certification Services

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

LP OSB Sheathing & Structural 1 Sheathing

PinkWood Ltd. Revised September 29, 2017

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

Slide 1. Slide 2. Slide 3. Lumber Standards and Specifications. Learning Objectives. Frank Stewart Western Wood Products Association

Joint Evaluation Report ICC-ES (800) (562)

USING WOOD STRUCTURAL PANELS FOR SHEAR AND WIND UPLIFT APPLICATIONS

2.2E Parallam PSL Deep Beam

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

R Code and Commentary for 2012 NC Residential Code final 03/06/13

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services

Administrative Changes

Job-made ladders for construction

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: LOUISIANA PACIFIC CORPORATION

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

System Report. Design for Combined Shear and Uplift from Wind. and equipment, and Section Analysis

TYPICAL BEARING WALL FRAMING

MINIMUM REQUIREMENTS FOR WOOD DECKS - IRC 2009

REPORT HOLDER: GLASS VICE HOLDINGS LTD. POST OFFICE BOX MAIRANGI BAY, AUCKLAND 0754 NEW ZEALAND EVALUATION SUBJECT:

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: AFM CORPORATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

Residential Floor & Roof Systems Product Guide

Joint Evaluation Report ICC-ES (800) (562)

NatureWood Construction Product Specification Guide

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

2003 International Residential Building Code

TOWN OF WILTON 22 TRAVER ROAD GANSEVOORT, NY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

Introducing TJ Insulated Structural Framing Components

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

PHOTO 1: View from Inside the Structure. Note the Rotation of the WSP, Failure at the Lower Leading Edge and Deformation of the Top Plate

TOWN OF DEWITT PLANNING AND ZONING PERMIT REQUIREMENTS FOR DECKS

RB 133 RIM BOARD PRODUCT STANDARD. Version 2.3

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Guide to Attaching Exterior Wall Coverings through Foam Sheathing to Wood or Steel Wall Framing

Universal Panels & Accessories

Originally Issued: 02/11/2011 Revised: 02/23/2018 Valid Through: 02/28/2019

ADDENDUM No. 6. ITB No. 4424: W.R. Wheeler (Swift Run) Service Center PUD Non-motorized Improvements Phase 1

ATI Evaluation Service A Division of Architectural Testing Certification Services

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

Evaluation of Full-Scale House Testing Under Lateral Loading

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Transcription:

May 10, 2016 1:00pm Why Decks Fail Design and New PA UCC Requirements to Improve Safety Chris Hine Housing and Land Development Specialist Provider #60114115 AIA Course #PHRCWEB516 Pennsylvania Housing Research Center 219 Sackett Building University Park, PA 16802 P: 814 865 2341 www.phrc.psu.edu Description In this one hour workshop we will review past deck failures and explain the critical failure points in the design. Then we will review the current code requirements for residential deck design and construction. This will include reviewing the new prescriptive design requirements for joists, beams and post sizing. We will also review the design requirements for stairs and stair illumination. The newly adopted code requirements lay the groundwork for the design of a residential deck. Upon completion of this workshop, attendees will know where to find and apply the prescriptive design guidelines set forth in the IRC code books. 7 Objectives The learning objectives for this program are: Understand how decks can fail and cause harm to the occupants. Provide an understanding of the deck requirements in the IRC and Pennsylvania s Uniform Construction Code. Provide an overview of proper materials and construction methods Provide background information on how to inspect for compliance with the IRC for occupant safety 8 1

Outline Review failures in decks Ledger connection Guardrails Review the NEW prescriptive requirements for Residential Deck Design and Construction 9 Deck Failures 10 Normal Deck Loading 11 2

Excessive Deck Loading 12 13 Source www.deckmagazine.com 14 Source www.thatshouldhold.com 3

15 16 17 4

18 19 Source www.charlotteobserver.com.com 20 Source www.latimes.com 5

Injuries More injuries may be connected to deck failures than all other wood building components and loading cases combined! 21 Guardrail Loading 22 Guardrail failure Improper railing attachments resulted in a lady falling 14 feet to her death. 23 Photo courtesy of Darin Clements 6

Post attachment Toe nailed post? 24 25 Compliant? 26 7

Compliant? 27 Structural Review It is much more than just a deck! 28 And they are EVERYWHERE! 29 8

Is there a difference in design practice? House vs. Deck 30 Structural Review House vs. Deck Different structural systems House Platform frame Deck Post and beam (Now covered by the IRC See R507.1 Decks) Less structural redundancy Larger loads on members and connections Lower lateral stability 31 Structural Review House vs. Deck Increased exposure (wet service UV) Wood durability Fasteners Uncertain (unexpected) service load during the life of the structure Design life expectancy House = 50 years Deck =? Deck Planks (wood) = 15 years Deck Planks (composite) = 8 25 years Structural Wood = 10 30 years Fasteners (galvanized) = 10+ years Fasteners (hot dipped galvanized = 35 60 years Source www.nachi.org Failure House failure may not be catastrophic Deck failure usually are 32 9

New UCC Adopted Changes to Residential Deck Construction 34 The Pennsylvania regulation related to Residential Construction codes changed effective December 31, 2015. 35 New Residential Deck Section in 2015 IRC R507.1 Decks. Wood framed decks shall be in accordance with this section or Section R301 for materials and conditions not prescribed herein (See text in 2015 IRC for remainder of unchanged section.) PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(I) 36 International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. 10

Decking Design Criteria R507.4 Decking. Maximum allowable spacing for joists supporting decking shall be in accordance with Table R507.4. MATERIAL TYPE AND NOMINAL SIZE TABLE 507.4 MAXIMUM JOIST SPACING MAXIMUM ON CENTER JOIST SPACING Perpendicular to joist Diagonal to joist a 1 1/4 inch thick wood 16 inches 12 inches 2 inch thick wood 24 inches 16 inches Plastic Composite In accordance with Section In accordance with Section R507.3 R507.3 a. Maximum angle of 45 degrees from perpendicular for wood deck boards PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(K) section PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(S) table 37 International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. Design Criteria for Composite Decking Text adopted through reference in Table R507.4 Portions of R507.3.1 Labeling. includes the maximum allowable span determined in accordance with ASTM D7032. Portions of R507.3.5 Installation of plastic composites. Plastic composite deck boards, stair treads, guards and handrails shall be installed in accordance with this code and the manufacturer s instructions. 38 Section R507.3 is adopted by reference only to the extent that it provides the maximum on center joist spacing for plastic composite decking. Subsections of R507.3 are adopted as referenced by the language of R507.3 only to the extent that it provides the maximum on center joist spacing for plastic composite decking. Requirement that plastic composite components be installed with the manufacturer s instructions is adopted by reference as it relates to the maximum on center joist spacing for plastic composite decking. Deck Joist Design Criteria R507.5 Deck joists. Maximum allowable spans for wood deck joists, as shown in Figure R507.5, shall be in accordance with Table R507.5. Deck joists shall be permitted to cantilever not greater than one fourth of the actual, adjacent joist span. Figure R507.5 Typical Deck Joist Spans PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(L) new section PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(W) new figure 39International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. 11

Deck Joist Span Table SPECIES a Sothern Pine Douglas fir larch d, hem fir d spruce pine fir d SIZE TABLE R507.5 DECK JOIST SPANS FOR COMMON LUMBER SPECIES f (ft. in.) SPACING OF DECK JOISTS WITH NO CANTILEVER b SPACING OF DECK JOISTS WITH CANTILEVERS c (inches) (inches) 12 16 24 12 16 24 2 X 6 9 11 9 0 7 7 6 8 6 8 6 8 2 X 8 13 1 11 10 9 8 10 1 10 1 9 8 2 X 10 16 2 14 0 11 5 14 6 14 0 11 5 2 X 12 18 0 16 6 13 6 18 0 16 6 13 6 2 X 6 9 6 8 8 7 2 6 3 6 3 6 3 2 X 8 12 6 11 1 9 1 9 5 9 5 9 1 2 X 10 15 8 13 7 11 1 13 7 13 7 11 1 2 X 12 18 0 15 9 12 10 18 0 15 9 12 10 Rosewood, 2 X 6 8 10 8 0 7 0 5 7 5 7 5 7 western cedars, 2 X 8 11 8 10 7 8 8 8 6 8 6 8 6 ponderosa pine e, 2 X 10 14 11 13 0 10 7 12 3 13 3 10 7 red pine e 2 X 12 17 5 15 1 12 4 16 5 15 1 12 4 a. No. 2 grade with wet services factor. b. Ground snow load, live load = 40 psf, dead load = 10psf, L/ = 360. c. Ground snow load, live load = 40 psf, dead load = 10psf, L/ = 360 at main span, L/ = 180 at cantilever with a 220 pound load applied to end. d. Includes incising factor. e. Northern species with no incising factor f. Cantilevered spans not exceeding the normal depth of the joist are permitted. PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(T) 40 International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. Protection Against Rotation R507.5.1 Lateral restraint at supports. Joist ends and bearing locations shall be provided with lateral restraint to prevent rotation. Where lateral restraint is provided by joist hangers or blocking between joists, their depth shall equal not less than 60 percent of the joist depth. Where lateral restraint is provided by rim joists, they shall be secured to the end of each joist with not less than (3)10d nails or (3) No. 10 x 3 inch long wood screws. PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(M) 41 International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. Deck Beam Design Criteria R507.6 Deck Beams. Maximum allowable spans for wood deck beams, as shown in Figure R507.6, shall be in accordance with Table R507.6. Beam plies shall be fastened with two rows of 10d nails minimum at 19 inches on center along each edge. Beams shall be permitted to cantilever at each end up to one fourth of the actual beam span. Splices of multispan beams shall be located at interior post locations. Figure R507.6 Typical Deck Beam Spans PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(N) new section PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(X) new figure 42International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. 12

Deck Beam Span Table 43 TABLE R507.6 DECK BEAM SPAN LENGTHS a, b (ft. in.) DECK JOIST SPAN LESS THAN OR EQUAL TO: (feet) SPECIES a SIZE 6 8 10 12 14 16 18 2 2 X 6 6 1 5 11 5 4 4 10 4 6 4 3 4 0 2 2 X 8 8 9 7 7 6 9 6 2 5 9 5 4 5 0 2 2 X 10 10 4 9 0 8 0 7 4 6 9 6 4 6 0 2 2 X 12 12 2 10 7 9 5 8 7 8 0 7 6 7 0 Southern pine 3 2 X 6 8 2 7 5 6 8 6 1 5 8 5 3 5 0 3 2 X 8 10 10 9 6 8 6 7 9 7 2 6 8 6 4 3 2 X 10 13 0 11 3 10 0 9 2 8 6 7 11 7 6 3 2 X 12 15 3 13 3 11 10 10 9 10 0 9 4 8 10 3 X 6 or 2 2 X 6 5 5 4 8 4 2 3 10 3 6 3 1 2 9 3 X 8 or 2 2 X 8 6 10 5 11 5 4 4 10 4 6 4 1 3 8 3 X 10 or 2 2 X 10 8 4 7 3 6 6 5 11 5 6 5 1 4 8 Douglas fir larch e, 3 X 12 or 2 2 X 12 9 8 8 5 7 6 6 10 6 4 5 11 5 7 hem fir e, 4 X 6 6 5 5 6 4 11 4 6 4 2 3 11 3 8 spruce pine fir e, 4 X 8 8 5 7 3 6 6 5 11 5 6 5 2 4 10 redwood, 4 X 10 9 11 8 7 7 8 7 0 6 6 6 1 5 8 western cedars, 4 X 12 11 5 9 11 8 10 8 1 7 6 7 0 6 7 pondersoa pine f, 3 2 X 6 7 4 6 8 6 0 5 6 5 1 4 9 4 6 redpine f 3 2 X 8 9 8 8 6 7 7 6 11 6 5 6 0 5 8 3 2 X 10 12 0 10 5 9 4 8 6 7 10 7 4 6 11 3 2 X 12 13 11 12 1 10 9 9 10 9 1 8 6 8 1 a. Ground snow load, live load = 40 psf, dead load = 10psf, L/ = 360 at main span, L/ = 180 at cantilever with a 220 pound load applied to end. b. Beams supporting deck joists from one side only. c. No. 2 grade, wet service factor. d. Beams depth shall be greater than or equal to depth of joists with a flush beam condition. e. Includes incising factor. International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. f. Northern species. Incising factor not included. Joist Bearing Requirements R507.7 Deck joist and deck beam bearing. The ends of each joist and beam shall have not less than 1 1/2 inches of bearing on wood or metal and not less than 3 inches on concrete or masonry for the entire width of the beam. Joist framing into the side of a ledger board or beam shall be supported by approved joist hangers. Joists bearing on a beam shall be connected to the beam to resist lateral displacement. PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(O) 44 International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. Deck Post to Beam Connection R507.7.1 Deck post to deck beam. Deck beams shall be attached to deck posts in accordance with Figure R507.7.1. or by other equivalent means capable to resist lateral displacement. Manufactured post tobeam connectors shall be sized for the post and beam sizes. All bolts shall have washers under the head and nut. Exception: Where deck beams bear directly on footings in accordance with Section R507.8.1 Figure R507.7.1 Deck Beam to Deck Post PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(P) new section PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(Y) new figure 45 International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. 13

Deck Post Design Criteria R507.8 Deck posts. For single level wood framed decks with beams sized in accordance with Table R507.6, deck post size shall be in accordance with Table R507.8. TABLE R507.8 DECK POST HEIGHT a DECK POST SIZE MAXIMUM HEIGHT a 4 X 4 8' 4 X 6 8' 6 X 6 14' a. Measured to the underside of the beam. PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(Q) new section PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(U) new table 46 International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. Deck Post Footing Detail R507.8.1 Deck post to deck footing. Posts shall bear on footings in accordance with Section R403 and Figure R507.8.1. Posts shall be restrained to prevent lateral displacement at the bottom support. Such lateral restraint shall be provided by manufactured connectors installed in accordance with Section R507 and the manufacturers instructions or a minimum post embedment of 12 inches (305 mm) in surrounding soils or concrete piers. Figure R507.8.1 Typical Deck Posts to Deck Footings PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(R) new section PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(Z) new figure 47 International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. Lateral Load Design R507.2.4 Deck lateral load connection. The lateral load connection required by Section R507.1 shall be permitted to be in accordance with Figures R507.2.3(1) or R507.2.3(2). Where the lateral load connection is provided in accordance with Figure 507.2.3(1), hold down tension devices shall be installed in not less than two locations per deck, within 24 inches of each end of the deck. Each device shall have an allowable stress design capacity of not less than 1500 pounds. Where the lateral load connections is provided in accordance with Figure R507.2.3(2), the hold down tension devices shall be installed in not less than 4 locations per deck, and each device shall have an allowable stress design capacity of not less than 750 pounds. 48 PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(J) International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. 14

Lateral Load Design Option #1 Figure R507.2.3(1) Deck Attachment for Lateral Loads (Same as IRC 2009 figure) 49 PA UCC Reference: Title 34, Chapter 403.21 (7)(iii)(V) International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. Lateral Load Design Option #2 Figure R507.2.3(2) Deck Attachment for Lateral Loads PA UCC Reference: Title 34, Chapter 401.21 (7)(iii)(V) International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. 50 Proprietary Installation Instructions Alternative connection detail examples (proprietary) Source: Simpson Strong Tie Technical Bulletin Installation Options for Deck Lateral Load Connections 51 15

Proprietary Installation Instructions Alternative connection detail examples (proprietary) Source: Simpson Strong Tie Technical Bulletin Installation Options for Deck Lateral Load Connections 52 Proprietary Installation Instructions Alternative connection detail examples (proprietary) 53 Source: Simpson Strong Tie Technical Bulletin Installation Options for Deck Lateral Load Connections Proprietary Installation Instructions Alternative connection detail examples (proprietary) 54 Source: Simpson Strong Tie Technical Bulletin Installation Options for Deck Lateral Load Connections 16

Proprietary Installation Instructions Alternative connection detail examples (proprietary) Source: Simpson Strong Tie Technical Bulletin Installation Options for Deck Lateral Load Connections 55 Proprietary Installation Instructions Alternative connection detail examples (proprietary) 56 Source: Simpson Strong Tie Safety Consideration Not Changed by the New UCC Codes Guardrails 57 17

Guardrail Loading 2009 IRC Table R301.5 Guardrails and Handrails 200 lb live load Guardrail in fill components 50 lb live load Single concentrated load applied in any direction at any pint along the top. 58 Guardrail Design with DCA 6 Decks greater than 30 above grade require a guard 59 courtesy, American Wood Council, Leesburg, VA Guardrail Requirements Minimum 4x4 post 60 courtesy, American Wood Council, Leesburg, VA 18

Guardrail Requirements Guard post to rim joist 61 courtesy, American Wood Council, Leesburg, VA Thoughts on Guards Never rely on nails in withdrawal. Guard rail post connection capacity: Difficult to calculate (too many variables, large number of connections, requires 3 dimensional analysis) relies on full assembly (weakest link) is difficult to field verify (hip check is probably ~ 30lbs) Notched posts should not be allowed in most cases. Proprietary systems are all tested at required load + factor ofsafety. 62 References International Code Council (ICC). (2008). 2009 International Residential Code, Country Club Hill, Ill. International Code Council (ICC). (2014). 2015 International Residential Code, Country Club Hill, Ill. PA Code Title 34, Chapter 401.21 (7)(iii)(A) (BB) PA Code Title 34, Chapter 401.21 (9)(i) (v) American Wood Council, DCA 6 09, Leesburg, VA http://www.awc.org/codes standards/publications/dca6 63 19

Evaluations / Certificate / Questions? This concludes The American Institute of Architects Continuing Education Systems Course Link to Certificate: http://www.cvent.com/d/bfqvn3/4w This concludes the 2015 16 PHRC Webinar Series. The 2016 17 series will begin in September 2016. Have a wonderful summer See you in September! 64 20