The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

Similar documents
REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

Beginning of the Course

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

SPECIFICATION GUIDELINE

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER:

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

Integrated Air & Water Barrier Systems

EXTERIOR INSULATION FINISHING SYSTEMS. EIFS Alpha System. The House of Scandinavian Finishing Materials

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

Managing Rainwater at the Window-Wall Interface

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

Senturion TM III Wall System

Magnum Board Section Digicon Information Inc. Page 1

Gold Bond BRAND Gypsum Sheathing

Armourwall Stucco Systems

.1 Provide submittals in accordance with Section Submittal Procedures.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

NFPA 285 Compliant Wall Systems and Assemblies

Building Enclosure Performance for Existing and New Buildings

How do you install yours?

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Differences between EnCon Insulated Precast and EIFS

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

Slab edge insulation is one of

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

NEXT GENERATION HIGH PERFORMANCE WALLS

Building Envelope Systems Exam Learning Objectives

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: PROWALL BUILDING PRODUCTS, INC.

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

United States R E S I D E N T I A L. The Value of Residing With STYROFOAM Brand XPS Insulation

External Thermal Insulation Composite System Insulation below ground level

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

A Design Review of Waterproofing Codes

Background Basement Thermal Behavior

The Original. The Innovator.

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: DIRECT-APPLIED FINISH SYSTEMS REPORT HOLDER: STO CORP.

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Moisture Considerations for Insulated Building Assemblies

DuROCK InsulROCK EIFS

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

General Guide to Joint Sealants for Architects

ELEVATION FOR DETAIL REFERENCE ONLY

SPECIFICATION GUIDE. thin glazed brick

INTRODUCTION Twentieth-century stucco wall claddings

Construction Sealants 101 Making the Connections. Building Enclosure Council Austin October 3, 2012

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

MID-RISE DESIGN & CONSTRUCTION

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

ELEVATION FOR DETAIL REFERENCE ONLY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ACF for Soffit Specifications

Parex Continuous Insulation (CI)

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

KNIGHT WALL SYSTEMS GUIDE DETAILS:

Technical Notes 28 - Anchored Brick Veneer, Wood Frame Construction Rev August 2002

MAKE ROOFS LAST LONGER

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

Rainscreen Gaps in Exterior Walls

Combustible Exterior Wall Cladding Systems: An ICC Perspective

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

THERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240

How to Meet Code and Manage Moisture in an Environment of Increasing Air Tightness Requirements. Ted Winslow

THERMAL-FLEX ICF INSULATED CONCRETE FORMS COATING ASSEMBLY TO ICF BLOCK MANUFACTURERS SPECIFICATIONS / SECTION STUC-O-FLEX PART 1 - GENERAL

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

Exterior Building Materials & Detailing

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Detail Set: Thermax Wall System Masonry

The Building Envelope Solution. Mike Lowery A&D Products, LLC

Design & Construction Standards, Revised January

Fiber HE AF Specifications

A. Source Limitations: Obtain each type of building insulation through one source.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

Installation Procedures for the Ultra Air Barrier Wall System

Vapour Diffusion for Residential Construction. Canada and Northern USA VAPOUR DIFFUSION FOR RESIDENTIAL CONSTRUCTION CANADA AND NORTHERN USA

KNIGHT WALL SYSTEMS GUIDE DETAILS:

The Role of Control Layers in Building Enclosure Design

AquaFlash System Installation Guide DS196

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SUPERWALL MANUFACTURING, INC.

Figures 1A-1C Light frame and mass wall systems with continuous insulation for codecompliant. commercial building construction.

Improve Energy Efficiency and Air Sealing in Above-Grade Walls

SECTION HVAC INSULATION

FLUID APPLIED WATERPROOFING

Brick Veneer / Wood Stud Walls

Finestone Stucco Ultra Wall System

Improving Drainage and Drying Features in Certain Conditions: Rain Screen Designs for Absorptive Claddings

Construction. Sikaflex 15 LM. Application Instructions. Sika Corporation

Senershield -R / Senershield -VB

Transcription:

Note: This document has been divided into several sections in order to suit the limitations of the website. The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide. Example Details The recommendations developed above are embodied in the example detail drawings in this section. These drawings are only one example of how these principles can be achieved in practice since many other combinations of materials and wall assemblies may be acceptable alternatives. These details are as similar as practical to details present in the five CMHC Best Practice Guides, which contain many more details and supporting text and specifications for different wall systems. The majority of the details relate to EIF systems, since this type of product is newer and supported by fewer traditional details. EIFS have also had a disproportionate share of rain penetration problems, and the details presented have been chosen to reflect the most common areas of concern. Figure 24 provides a schematic section of the intersections that may require details for a particular project. In some projects, few details are required, but in many large or complex architecturally designed buildings, almost all of the areas noted in the figure below will require detail sections or isometrics at 1:5 scale (or at most 1:10 scale). It is important that all details clearly show any membranes and important sealants, laps, fasteners or hems in flashing. It may be necessary to distort the scale somewhat to allow for this level of detail. Air movement, vapour diffusion, fire and smoke control systems are required for all building enclosures -- these aspects have been considered in the details presented here, but may vary depending on the approach taken or type of building occupancy. For example, in many cases, a continuous fully-adhered water resistant barrier (WRB) can also act as an excellent air barrier. Since many WRB products are also vapour barriers, most or all of the insulation must then be placed outside of this plane. Page 29 of 50

Figure 24: Typical Intersections Requiring Details Page 30 of 50

Page 31 of 50

Page 32 of 50

Page 33 of 50

Page 34 of 50

Page 35 of 50

Page 36 of 50

Page 37 of 50

Page 38 of 50

Page 39 of 50

Page 40 of 50

Page 41 of 50

Page 42 of 50

Page 43 of 50

Page 44 of 50

Note: Fireproofing of structural elements and fire-rated floor assembly not detailed in this drawing. Page 45 of 50

Bibliography Many of the references are important sources of further information, especially the entire series of CMHC Best Practice Guides, available from CMHC or on line at: http://www.cmhc-schl.gc.ca Technical Notes on Brick Construction, "Note 7: Water Resistance of Brick Masonry, Design and Detailing Part 1", Brick Institute of America, Reston, VA, Feb. 1985 (Reissued Feb. 1998), and many other guides for masonry. Hutcheon, N. B., and G. O. P. Handegord. Building Science for a Cold Climate. NRC/IRC, 1983, Order no. NRCC-39017. All of the 200+ legendary Canadian Building Digests, available from NRCC/IRC, and on line at: http://www.nrc.ca/irc/cbd/cbd-e.html Lstiburek, J. Builder s Guide for Cold Climates, Building Science Corp, Westford, MA, 2001. Outstanding drawings for excellent rain control and durable, healthy practice for low-rise housing in cold climates. Available for 3 other climates zones from www.buildingscience.com. Exterior Wall Construction in High-Rise Buildings, CMHC, Ottawa, 1991. ISBN 0-660- 13759-3. A must-have guide for Canadian practitioners. Page 46 of 50

Glossary of Terms Adhesive Air Barrier Back Wrapping Backer Rod Base Coat Bond Breaker Capillary Action Capillary Break Cement Board Control Joint Durability Drip A compound used for bonding surfaces together, e.g., insulation board to the substrate in an EIFS, usually applied in the form of a trowel-applied paste. An EIFS adhesive and base coat may be the same material used for different layers. More precisely, the air barrier system (ABS), a three-dimensional assembly of materials designed to provide the primary resistance to airflow through an enclosure. An air-vapour barrier is a system that combines the function of the ABS with that of the vapour barrier. The act of carrying the system reinforcement around the ends of the insulation boards and terminating between the insulation and substrate at system interfaces and terminations to firmly attach the base coat to the substrate and protect the edges of the insulation board at these locations. Also refer to End wrapping. A flexible material (usually closed-cell polyethylene) formed into a circular crosssection and provided in rope form, used to provide backing and a bond breaker for the application of sealant. A compound used to embed and to cover the reinforcing fabric of an EIFS. The base coat also acts as the primary moisture resistant layer. A sheet, tape, or liquid applied material that prevents adhesion on a designated surface. Liquid water is attracted to the molecules on the surfaces of many materials. If such an attractive material makes up a porous body then water will be forcibly drawn into the millions of tiny pores, a process called capillary action. Capillary action explains how liquid water is transported through concrete, wood, brick etc. A capillary break is a layer or air space in an assembly that permits little or no capillary action, and hence breaks the transport of liquid water through an assembly made up of porous materials. Metals, glass, plastics, bitumen, etc are often used as capillary breaks between, for example, concrete and wood. A sheathing product made of cement-bonded fibre-reinforced composites (typically glass or wood fibres are used as reinforcing). Cement board is moisture and fire resistant and is used as a substrate sheathing. Refer to ASTM C1186. A formed, sawed, or assembled joint acting to regulate the location of cracking, separation, and distress resulting from dimensional or positional change. The capability of a building, assembly, component, product, or construction to maintain serviceability for the desired and expected length of time. A horizontal geometric feature provided on an exterior wall to ensure that flowing water will drip free rather than be pulled back toward a vertical enclosure element by surface tension. A drip groove is commonly employed in solid materials like Page 47 of 50

concrete and EIFS whereas a drip edge is used for thinner sheet materials. The horizontal edge of the material prevents water flowing back to the vertical surface. End Wrapping EIFS An EIFS term denoting the act of wrapping the reinforcement and basecoat around the edges of the insulation board and terminating and bonding to the substrate at an opening in the substrate. Like back wrapping, end wrapping is a means of securely fixing the lamina where it ends at joints and penetrations. An acronym for an Exterior Insulated Finish System, a light weight exterior cladding system consisting of an insulation board mechanically or adhesively attached to a wind-load-bearing substrate, and covered with an integrally reinforced coated fibreglass mesh, base coat and a protective surface finish. Some EIFS Terms (for a horizontal section) Interior finish Back wrapping Substrate System (steel stud and concrete block shown) Substrate Sheathing Adhesive Insulation Drained space Sealant Backer rod Base coat c/w reinforcement Finish coat Lamina End or edge wrapping Two-stage joint End-Dam A vertical or near vertical upstand from the end of a flashing or window sill, used to prevent water from flowing off the end of the flashing or sill. End dam Window sill or flashing Drip edge Sealed or integral with sill EPS - Expanded Polystyrene Expanded polystyrene (EPS) is a rigid cellular foamed-plastic insulation material manufactured by expansion of expanded polystyrene beads within a mould. This mould creates an open cell structure filled with air. EPS is the most Page 48 of 50

widely used insulation for EIFS applications and is manufactured in various densities allowing design flexibility for compressive properties. Extruded Polystyrene (XPS) Extruded polystyrene insulation (XPS) is rigid cellular foamed-plastic insulation Expansion Joint Finish Coat Flashing A structural separation between building elements that allows independent movement without damage to the assembly. The coating applied to the base coat to finish the lamina. The finish coat provides colour, texture, water repellency, dirt resistance and ultra violet ray resistance. A waterproof material used to redirect or shed drained water, or occasionally to act as a capillary break Non-paper faced Gypsum Sheathing A moisture resistant type of exterior gypsum sheathing. The gypsum core is treated for water repellency and either a glass matt applied to each face as reinforcement (ASTM C1177) or the core is integrally strengthened with distributed cellulose fibres Gypsum Sheathing Exterior grade gypsum board used as sheathing, typically treated with water repellents and governed by gypsum sheathing as per ASTM C79. IGU Joint Insulated glazing unit. Manufactured unit with two or more sheets of glass with hermetically sealed airspaces separating them to increase thermal performance, sound, and solar control. An interface between elements. Joints may be needed to allow for movement of different parts of a building or assembly, or may be required to make construction sequences practical. In all cases, the functional requirements of the enclosure must be maintained the same as for the body of an enclosure element, although aesthetic requirements may be relaxed. A joint may pass through the entire enclosure assembly, in which case it is a building movement joint, or more commonly referred to as an expansion joint. Control joints are surface cuts or intentional geometric features which control the location of shrinkage cracks and are proprietary requirements. Construction joints are formed between successive building elements parts during construction work. Lamina Reinforcement Rigid Insulation The composite material layer installed over the insulation layer, comprised of the reinforcement, base coat and finish coat. Material or materials used to improve the mechanical properties of the base coat. It may consist of one or a mix of polymer fibres, alkali-resistant glass fibres, and, most commonly, plastic coated fibreglass mesh. Rigid board material which provides thermal resistance. Foam plastic such as EPS, XPS, and polyisocyanurate are commonly used, polyurethane and may be found. Page 49 of 50

Semi-rigid Insulation Board material which provides thermal resistance comprised of mineral fibres. Mineral fibre insulation is normally used for its fire resistance properties and is typically comprised of glass or rock wool. Sealant A flexible, polymer-based elastomeric material installed wet and used in the assembly of the building enclosure to seal gaps, seams or joints and to provide a clean finish, or waterproof, or make the joint more air tight. Sheathing Membrane A generic term for sheet applied layer that resists the passage of liquid water through vertical, drained surfaces. Asphalt-impregnated building papers and felts and polymeric housewraps are the most common products available. Source Drained Another term for a face sealed system that allows water to drain at the joints or penetrations which are assumed to be the only point at which water penetrates past the face of an assembly. Substrate Sheathing Material to which an EIFS is attached. The substrate sheathing is typically plywood or non-paper faced gypsum board. When the structural wall is comprised of masonry or concrete, EIFS may be applied directly to the masonry or concrete without the use of a substrate sheathing. Substrate The structural plane of the building to which EIFS is attached, e.g., exterior sheathing, concrete masonry, concrete, etc. Water Resistant Barrier A sheet, spray- or trowel-applied membrane or material layer that prevents the passage of liquid water even after long-term or continuous exposure to moisture. Page 50 of 50