CROSS-CONNECTION CONTROL/BACKFLOW PREVENTION

Similar documents
December Illinois American Water Cross Connection Control Program

Backflow Prevention by Containment & Cross-Connection Control Program Easton Suburban Water Authority

; WATERMAINS SPECIFICATIONS FOR CROSS CONNECTIONS and BACKFLOW PREVENTION SECTION C5.0

JACKSON COUNTY WATER AND SEWERAGE AUTHORITY. Cross-Connection Control Program

ROCHESTER PUBLIC UTILITIES PUBLIC WATER SYSTEM CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION PROGRAM FOR ROCHESTER, MINNESOTA

Water Safety: Protecting Our Communities from Backflow Incidents

Module #9: Cross-Connection Control and Backflow Prevention

Mobile Area Water and Sewer System. Section 6. Cross-Connection and Backflow Prevention Program

DENR Public Water Supply Section FIGURE 1(A): ALKALINITY VS PH

Water Service 39 BACKFLOW PROTECTION

TITLE 64 LEGISLATIVE RULE BUREAU FOR PUBLIC HEALTH SERIES 15 CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION. use.

Backflow Prevention Program Revised:

POLICY GOVERNING CROSS CONNECTIONS, AUXILARY INTAKES, BYPASSES, AND INTERCONNECTIONS

ALDERWOOD WATER & WASTEWATER DISTRICT SNOHOMISH COUNTY, WASHINGTON RESOLUTION NO

Charlotte County Utilities Manual of Rules and Regulations Governing Cross- Connection Control FEBRUARY 2008

City of Ottawa Backflow Prevention Program

BEAU CHÊNE HOMEOWNERS ASSOCIATION, INC. CROSS CONNECTION CONTROL RULE

Milk Pre-Cooler Plumbing Considerations. ATCP 65, Wisconsin Administrative Code and the 2015 PMO

STANDARDS FOR BACKFLOW PREVENTION ASSEMBLIES

Cross-Connection Control Program. Manual of Procedures

Fort Collins - Loveland Water District. Cross-Connection Control Manual

2015 UPC Chapter 6 Water Systems Part 1 RV

Sec. T. - Cross connection control.

Needs To Know For Cross-Connection Control System Operators

TORONTO MUNICIPAL CODE CHAPTER 851, WATER SUPPLY. Chapter 851 WATER SUPPLY

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

WATER SUPPLY AND DISTRIBUTION

Lawn Sprinkler Agreement To Be Read and Signed by the Homeowner

PALMERSTON NORTH CITY PALMERSTON NORTH STORMWATER DRAINAGE BYLAW. Administration Manual

Division II Contractors

SECTION 620 CROSS CONNECTION CONTROL

Water Supply Corporation here by adopts the following regulations and restrictions on the delivery and consumption of water.

WARWICK TOWNSHIP Dept. of Planning & Zoning

ARKANSAS PLUMBING C ODE. Based on the 2006 International Plumbing Code

HALL COUNTY DEPT OF PUBLIC WORKS & UTILITIES Page 1 of 8 Reuse Water End User Application

Backflow prevention. Information for plumbers

CROSS-CONNECTION CONTROL PROGRAM MANUAL

TIMBERLAKE IMPROVEMENT DISTRICT Jones Rd, Suite 120, Houston, Texas Phone Number (281)

Briefing note: Water conservation measures in the domestic sector prepared by the NTUA

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

Wellhead Protection General Guidelines for New Private Domestic Wells

CHAPTER 6 WATER SUPPLY AND DISTRIBUTION

Section 3. Applications. A separate application shall be made and a separate meter shall be installed for each premise, defined as follows:

Petersburg - Water, Sewers and Sewage Disposal

Cross Connection Plumbing. James Peterson Plumbing Program Phone: (651) E mail:

recycle water reuse it save up to from showers & baths for flushing toilets 30% of water use

CHAPTER 6 WATER SUPPLY AND DISTRIBUTION

The following is required for a complete permit submittal for each unit.

GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

APPENDIX A 2017 INDEX TO SCHEDULES

ORDINANCE NO

CHAPTER 6 WATER SUPPLY AND DISTRIBUTION

Recommended Amendments to the 2015 International Plumbing Code North Central Texas Council of Governments Region

A Guide for Drinking Water System Owners Seeking To Undertake a Backflow Prevention Program

PORT OF SAN FRANCISCO PLUMBING CODE. Based on the 2010 California Plumbing Codes

Chapter 3: General Regulations

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

1 Exam Prep Florida Building Code- Plumbing, 2014 Tabs and Highlights

The following is required for a complete permit submittal for each unit.

CHAPTER 6 WATER SUPPLY AND DISTRIBUTION

Healthy Homes Provisions of Lansing, Michigan Ordinances Extracted from by National Center for Healthy Housing

CERTIFICATE of OCCUPANCY APPLICATION RESIDENTIAL

2015 ISEP INTERNATIONAL SOLAR ENERGY PROVISIONS

THE 5Cs WATER HYGIENE TRAINING

Section 5 Design Criteria Domestic Water Facilities

Water Pipeline Design Guidelines

2013 R-1 Building Permit Package For Additions, Decks, Fences & Garages

2016 BACKFLOW PREVENTION EDUCATION COUNCIL OF COLORADO REGULATION SEMINAR SURVEY PANEL QUESTIONS

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

6 TH ANNUAL BACKFLOW TESTER MEETING

RESIDENTIAL FIRE SERVICE METERS Addendum #1

PART VII - WATER SYSTEM DESIGN CRITERIA

SECTION 3.0 SPECIFICATIONS FOR DRINKING WATER DISTRIBUTION SYSTEMS DESIGN

BUILDING PERMIT APPLICATION

Reclaimed Water Treatment, Distribution, Pumping and Storage Engineering Report Form

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS

Backflow Preventer Tester Plumbing License Code Path

Amendment to OPSS 493 (Nov 2015) Construction Specification for Temporary Potable Water Supply Services

CERTIFICATIONS AND LISTINGS

Virginia Department of Health Office of Drinking Water

CURRENT NORTH LAS VEGAS ADDENDA

Bloomington Township Public Water District User Information Packet. Water Service

Sub-Metering INFORMATION KIT

Water Service Inspection Checklist

GRAY WATER RECYCLING SYSTEMS

2016 CALGREEN RESIDENTIAL CHECKLIST MANDATORY ITEMS City of San Carlos - Building Division 600 Elm Street, San Carlos, CA Phone:

6.6 Drought and Emergency Response Stages

Chemigation. in Georgia

Continuing Certificate of Occupancy Pre-Inspection Checklist

SECTION Plumbing and Sewerage Construction and Maintenance Plumbing and Sewerage Inspector

Presented By Town of Medway Water Division

Rural Servicing Guidelines

Ontario s 2012 Building Code Division B, Part 7 Ontario Regulation 332/12

Outlines for Water Saving Practices in Kuwait

CITY AND BOROUGH OF WRANGELL WATER SHORTAGE MANAGEMENT PLAN

RÈGLEMENT REGARDING THE USE OF DRINKING WATER. the Municipality exploits six drinking water networks;

Article 10 - ADMINISTRATIVE SECTION

CONSERVATION PLAN April 2009

Section 5 - Planning Criteria. Section 5

Transcription:

4.19.2018 CROSS-CONNECTION CONTROL/BACKFLOW PREVENTION In accordance with the Pennsylvania Department of Environmental Protection s Safe Drinking Water Act, Highridge Water Authority (HWA), hereby implements the following policy: PA Title 25 Section 109.709(b) The public water supplier (PWS) shall develop and implement a comprehensive control program for the elimination of existing cross-connections and the effective containment of sources of contamination, and prevention of future cross-connections. I. CROSS CONNECTION a) A physical connection created between a possible source of contamination and the public drinking water system (HWA) that poses a potential health risk should an undesirable reversal of water flow carry a contaminant into the Highridge Water System. b) This reversal of flow is called backflow and can happen in the following instances: i. Backsiphonage occurs whenever conditions exist that cause a negative pressure in the public water system such as a high water withdrawal rate created by high public demand, a water main leak or firefighters opening hydrants. A negative pressure occurrence can siphon contaminants into the public water system (PWS) on any premise where a cross connection could exist. ii. Backpressure conditions exist when a pressure higher than that of the public water system is created in the user s plumbing system and causes foreign substances (contaminants) to be pushed into HWA s water system. These higher pressures inside a customer s plumbing can be generated by a pump, thermal expansion from a boiler, and occasionally elevation. c) The following are just several examples of cross-connection contaminants and backflow scenarios: i. Soapy water or cleaning compounds backsiphon to the PWS through a faucet or hose submerged in a bucket or laundry tub. ii. Pool water backsiphons into the PWS through a hose submerged in a swimming pool, hot tub, or spa. 1

iii. Fertilizers/pesticides back siphon into the PWS through a garden hose attached to fertilizer/pesticide sprayers. iv. Bacteria/chemicals/additives in a boiler system backsiphon into the PWS. v. Unsafe water pumped from a private well applies backpressure and contaminates the PWS through an illegal connection between the well and water supplied by Highridge. II. BACKFLOW PREVENTION The purpose of which is to isolate the particular premise and contain any contaminants to the user s side of PWS. a) Residential Customers Installation of an approved dual check valve device for backflow prevention is required. This will create a closed system within the home and may require the installation of a thermal expansion tank on the hot water tank. This device shall be located on the customers side of the water meter, as close to the meter as reasonably practical and prior to any other connection and will serve to separate the home owners water supply piping from the water mains of the PWS, thereby containing any contamination which may occur as a result of any cross connection and thus protecting the public water supply. b) Commercial/Industrial Customers A PWS approved backflow prevention assembly shall be installed at each service connection to a consumer s water system serving, but not necessarily limited to, the following types of facilities: - Laboratories - Hospitals, mortuaries, nursing homes or clinics, dental offices - Sewage treatment plants - Food or beverage processing plants - Chemical plants - Metal plating industries, processing plants - Vehicle washing facilities - Commercial boilers - Commercial fire sprinklers - Animal clinics - Commercial laundries - Mobile home parks or RV parks with RV hookups 2

- Multiple townhouse, condominium, and apartment unit exceeding 3 living units - Schools and colleges - Shopping plazas and malls - Power plants - Buildings with unspecified use NOTE: *Approved backflow prevention assemblies for commercial/industrial customers are testable. c) If the consumer s water system serves multiple units on the property, each living or commercial unit must have an individual approved backflow preventer/assembly to prevent cross supply between units. d) HWA shall determine backflow prevention requirements for all other facilities or activities not specified herein. e) Due to the potential volume of water associated with a backflow incident, any service (domestic or other) larger than 1 ½ inches in diameter shall be protected by testable backflow prevention assembly approved by HWA. III. APPROVED BACKFLOW PREVENTERS ASSE 1024 Dual check valve (non-testable) backflow preventer ASSE 1013 Reduced Pressure Zone backflow assembly (RPZ) testable ASSE 1015 Double Check Valve Assembly (DCVA) testable - For Commercial and Industrial applications, all installation and/or maintenance work must be done by a certified backflow prevention specialist. Definitions 3

1. Approved Any backflow prevention device/assembly that has been accepted by HWA as suitable for the proposed use. 2. Auxiliary Water System Any water source or system on the premises of, or available to, the customer except connections to HWA water system. 3. Backflow A condition, induced by a differential in pressure, that causes a reversal of flow of water from a consumer s water system into the public water system owned and operated by HWA. Backflow can result from either backsiphonage or back pressure. 4. Backflow Preventer Device/assembly that prevents backflow of water or any other substance into HWA s water system. 5. Backpressure An event which creates an increase of water pressure in the customer s water system that could create backflow into the PWS. 6. Backsiphonage The backflow of water into the PWS whenever the PWS line pressure drops below that of the customer s water system. A drop in the PWS water main pressure can be due to a water leak or other events whereby a heavy withdrawal of water occurs in the system. 7. Consumer Owner or person in control of any premises supplied with water through a connection to the public water system. 8. Consumer s Water System Any water system located on the consumer s premises supplied or connected to the public water system. A household plumbing system is considered to be a consumer s water system and begins after the HWA service valve (curb stop). 9. Containment Cross connection control device/assembly which isolates the consumer s entire facility from contaminating the public water system in the event of a backflow. *NOTE* Although containment prevents contamination of the public water supply, it offers no protection to the consumer s water system. 10. Contamination Degradation of the quality of drinking water that would create an actual health hazard to the public. 11. Cross-connection A physical connection created between a possible source of contamination and the public drinking water system. Any auxiliary water system having a connection to a potable water line is a cross-connection. 12. Degree of Hazard A determination by the water supplier as to the method of protection and installation that is sufficient to protect the public water system against a potential pollution or contamination hazard. 4

a) High Hazard highly dangerous if introduced to PWS that could cause death, injury, illness, or spread of disease, in other words, a definite danger to public health. Only reduced pressure zone assemblies can be used for this service connection. b) Low Hazard a pollutant introduced into PWS, although generally not a health hazard, but would constitute a nuisance, or be aesthetically objectionable. Only testable backflow preventers are acceptable for these service connections. 13. Double Check Valve Assembly (DCVA) An assembly composed of two single independently acting check valves, including tightly closing shut-off valves located at each end of the assembly that serves as a back flow preventer for use by commercial/industrial customers. 14. Dual Check Valve An approved backflow prevention device for residential customers. 15. Hot Water Heating Systems Used in residential premises and do not generate steam. Dual check valves (ASSE 1024) are permissible but must be replaced every 3-5 years. 16. Internal Protection Plumbing code requirements require the consumer to isolate all water-use appliances within a facility (e.g. kitchen appliances, central air conditioning units, boilers, process tanks, etc.) from other lines of the consumer s water system (plumbing). These devices prevent backflow contamination within and throughout the facility. Examples of the safety devices outlined in national plumbing code requirements include: air gaps built into sink, tub, and basin faucets anti-siphon type ballcocks in toilets vacuum breakers on hose bibs and sill cocks backflow preventers on lawn sprinklers backflow preventers on supply lines to boilers or other equipment containing non-potable and cross connected to the potable water system. certain municipalities require backflow protection on swimming pools, hot tubs, spas, residential solar heating systems, and private wells and other auxiliary water supplies. 17. Isolation in addition to the internal measures listed in #14, backflow prevention devices are required to prevent backflow contamination between multiple units served by a consumer s water system. 5

18. Non-potable water Water not safe for drinking, personal, culinary, or any other type of domestic use. Many auxiliary water systems contain non-potable water. 19. Potable water Water which is safe for drinking and domestic use which meets the requirements of DEP. 20. Property otherwise referred to as a premises. A lot, parcel, or other division of land that is: a) Used for separate dwelling purposes; b) Equipped for the preparation of food; c) Used for a house, building, structure or personal property for human occupancy, employment, recreation or other purpose; and d) Used for condominiums, multi-family dwellings, mobile or recreational vehicle (RV) sites, parks, campgrounds, commercial or industrial purposes. 21. Public Water System (PWS) Water system which consists of filtration facilities, pump stations, fire hydrants, water tanks, water mains, distribution lines, and any appurtenances used in the operation of supplying potable water to the public. HWA is a PWS. 22. Pumps Where a booster pump has been installed on the service line to a property, such pump shall be equipped with a low pressure cut-off device designed to shut off the booster pump when the pressure in the service line on the suction side of the pump drops to 10 psi or less. Must be tested annually and results provided to PWS. 23. Reduced Pressure Zone Assembly (RPZ) An assembly of two independently acting check valves, between which is located an automatically operated differential relief valve that is designed to prevent backflow. This assembly is one of two units that are required to be used by commercial and industrial customers. This shall be installed horizontally inside a building. 24. Service Connection The water service line extending from the water main to Authority s service valve (curb box) and is installed and maintained by the public water supplier. 25. Steam Boiler Generally used in commercial plumbing systems for heating larger buildings. Determined a high hazard and requires an RPZ (ASSE 1013) back flow assembly. Steam boilers are identified by the presence of a clear glass tube on one side of the boiler. V. TESTING FREQUENCY 6

a. Residential Visual check and/or test to coincide with meter maintenance and service line inspections. Change out subject to manufacturer s recommendation. b. Commercial/Industrial RPZ s and DCVA s shall be subject to annual testing by a certified test provider. Test results shall be reported to HWA on an approved form within 60 days after test date. Acceptable tester certifications: American Society of Sanitary Engineering (ASSE) Backflow Management, Inc. (BMI) New England Waterworks Association (NEWWA) American Water Works Association (AWWA) VI. RETROACTIVE INSTALLATION REQUIREMENTS The provisions of this policy shall apply to all new water customers and all water customers currently existing prior to the enactment date of this policy. All existing water services will be subject by HWA to inspection of premises to determine if backflow preventers are present. Backflow prevention devices or assemblies installed prior to this enactment of this policy, which do not comply with current requirements, shall be updated at customer s expense. VII. TERMINATIONS a. Upon determination that a backflow prevention device/assembly is necessary, HWA will provide water user written notice allowing forty-five days from date of written notice to complete installation. If not completed within the 45 day period, a second notice shall be sent. b. The second notice shall inform the water user that if installation of the backflow preventer is not completed within 15 days of the date of second notice, water service will be discontinued without further notice. c. The same procedure explained above in (a) and (b) shall be used when customers are notified that annual testing of the device/assembly is to be completed. The testing must be completed by a certified test person. d. HWA reserves the right to inspect any installation to ensure the proper backflow preventers are installed. 7