DBIL PRINCIPLE SPECIMEN. Kit Reorder # (200 tests/cartridge) Kit Reorder # (300 tests/cartridge) ANNUAL REVIEW Reviewed by: Date.

Similar documents
For In Vitro Diagnostic Use

ALT PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date.

Date. Alkaline phosphatase measurements are used in the diagnosis and treatment of liver, bone, parathyroid, and intestinal diseases.

For In Vitro Diagnostic Use

AAG PRINCIPLE SPECIMEN. REF (150 tests) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

CR-E PRINCIPLE REF A ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

PRINCIPLE REF ANNUAL REVIEW Reviewed by. Date. Date INTENDED USE

For In Vitro Diagnostic Use. Rx Only. Reviewed by Date Reviewed by Date

FER PRINCIPLE SPECIMEN. REF (150 tests) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

For In Vitro Diagnostic Use. Rx Only. Reviewed by Date Reviewed by Date

Date. Measurement of C-Reactive protein aids in evaluation of stress, trauma, infection, inflammation, surgery, and associated diseases.

This package insert contains information to run the Albumin BCP assay on the ARCHITECT c Systems and the AEROSET System.

Laboratory Procedure Manual

INSTRUCTIONS FOR USE

CRPH High Sensitivity Cardiac C-Reactive Protein

HerpeSelect 1 and 2 Immunoblot IgG (K000238; Focus Diagnostics, Inc.)

Complement C4 Universal Kit

Fibrinogen Universal Kit

INSTRUCTIONS FOR USE

Note: The taller 100 x 13 mm tube is not designed to run on the ACL TOP. Plasma after centrifugation of these tubes must be placed in sample cups.

Human IgG Rubella ELISA Kit

Human PAI-1 Activity ELISA Kit

Herpes Simplex Virus Type 1 (HSV-1) IgM ELISA Kit Protocol

DHEA-S ELISA FOR RESEARCH USE ONLY

IgG Antibodies TO Rubella Virus ELISA Kit Protocol

VALIDATION GUIDE FOR CHROMOGENIC ASSAY FOR ACTIZYME Anti-FIIa

Cyfra 21-1 IRMA. Product information Information about other products is available at: Userś Manual DE52100

IgG Antibodies To Toxoplasma. Gondii ELISA Kit

Mouse Collagen Type III ELISA

Human Anti-Hepatitis A Virus IgG (HAV-IgG) ELISA kit

AssayMax Human Albumin ELISA Kit

SAMPLE PROCEDURE , 11/07

Rat TNF-α ELISA REF. Ver5.0 RUO. ELISA Set for Accurate Quantitation from Cell Culture Supernatant, Serum, Plasma or Other Bodily Fluids

Human alpha-1-antitrypsin ELISA Kit

Human IgG ELISA Quantitation Set

Canine Symmetric dimethylarginine ELISA Kit

Factor VIII Antibody Screen assay

Human IgG Antigen ELISA Kit

Dopamine Research ELISA

Human Myostatin, ELISA Kit (MSTN)

determine optimum instrument settings for their own instruments and establish their own daily values.

AssayMax TM. Human IgG ELISA Kit. Assaypro LLC 3400 Harry S Truman Blvd St. Charles, MO T (636) F (636)

Human Factor IX (FIX)

BioOcean Human IgG ELISA Kit

ImmuLux Human IL-6 Fluorescent ELISA Kit

H-ferritin (Human) ELISA Kit

I-STAT POCT System PRINCIPLE:

Intrinsic Factor Ab ELISA Kit

AssayMax Human Factor XIII ELISA Kit

Enzyme immunoassay for the determination of total T4 (Thyroxin) concentration in human serum. Kit instruction. For in-vitro use only.

Sífilis. ELISA recombinante v.4.0. Enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies anti-treponema pallidum

Mouse Peptide YY (PYY) ELISA

Mouse Gonadotropin Releasing Hormone (GnRH) ELISA

Human Collagen Type III (COL3) ELISA

Mouse Factor XII Total ELISA Kit

Anti-PR-3(C-ANCA)IgG Enzyme Immunoassay

QUANTA Lite ACA IgM III For In Vitro Diagnostic Use CLIA Complexity: High

HBeAg and HBeAg Ab ELISA Kit

Human IL-10 ELISA MAX Set Deluxe

Human Angiotensin 2 (Ang2) ELISA

QUANTA Lite SS-A ELISA For In Vitro Diagnostic Use CLIA Complexity: High

Human Protein Z ELISA Kit

Meets Standards AFTER REVIEW ( 2.5 pts) Fail to meet the standard safety precautions, counseled one time

Please use only the valid version of the package insert provided with the kit.

Instructions for use. Corticosterone ELISA MS E-5400

Instructions for use CA 125 ELISA TM E-4300

ENA-6 Screen ELISA KIT

Global Headquarters 86 Cummings Park Woburn, MA Tel:

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Mouse Cytokine Assays: Tissue Culture Kit

Human Placental Lactogen (HPL) MICRO-ELISA Test Kit. the sample.

Anti-Cardiolipin IgG/IgM Enzyme Immunoassay

Human Alpha-2-Macroglobulin ELISA

Pre-Analytic Issues in Laboratory Medicine

Human Calprotectin ELISA Kit

AssayMax Human Antithrombin III ELISA Kit

ab Albumin Human ELISA Kit

MSD 96-Well MULTI-ARRAY and MULTI-SPOT Human Cytokine Assays: Base Kit

AssayMax Human Apo-B ELISA Kit

See external label 2 C-8 C Σ=96 tests Cat # 5201Z CARCINOEMBRYONIC ANTIGEN (CEA) ENZYME IMMUNOASSAYTEST KIT CEA ELISA. Cat # 5201Z

ab Anti-ENA Screen Human ELISA Kit

ab Anti-Sm IgG ELISA Kit

HUMAN CONNECTIVE TISSUE GROWTH FACTOR (CTGF) ELISA KIT

COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV GL = ISO 9001 = Biomaterial Hemolytic Assay. Kit Insert

Key to symbols used. List Number. For In Vitro Diagnostic Use. Store at 2-8 C. Store at C

See external label 2 C-8 C Σ=96 tests Cat # Hepatitis B. HBeAb. Cat # ANTIBODY TO HEPATITS B VIRUS E ANTIGEN ELISA

Immunoassay Kit Catalog # KCA0021. Canine. C-Reactive Protein

****** Competition ELISA Kit Instruction

HEPATITIS B anti HBc Catalog #: WB2696

Human IL-1 alpha ELISA Kit

PeliClass human IgG subclass ELISA kit Enzyme-linked immunosorbent assay

IQCP for the Akers Bio PIFA Heparin Platelet Factor 4 Rapid Assay

Title: Hemoglobin HemoCue Hb 301 method

Bovine IgG ELISA Catalog #:

Global Headquarters 86 Cummings Park Woburn, MA Tel:

Human Factor XII ELISA Kit

PDGFRB FISH PRODUCT DATASHEET. Proprietary Name: PDGFRB FISH for Gleevec Eligibility in Myelodysplastic Syndrome/Myeloproliferative Disease (MDS/MPD)

This package insert contains information to run the Theophylline assay on the ARCHITECT c Systems and the AEROSET System.

AssayMax Human IL-6 ELISA Kit

Human connective tissue growth factor (CTGF) ELISA Kit. MyBioSource.com. This package insert must be read in its entirety before using this product.

Plasma/Serum RNA/DNA Purification Mini Kit Product# 55200

Transcription:

SYNCHRON CX System(s) Chemistry Information Sheet Copyright 2008 Beckman Coulter, Inc. Direct Bilirubin Kit Reorder # 439715 (200 tests/cartridge) Kit Reorder # 476856 (300 tests/cartridge) For In Vitro Diagnostic Use ANNUAL REVIEW Reviewed by: Date Reviewed by: Date PRINCIPLE INTENDED USE reagent, when used in conjunction with SYNCHRON CX System(s) and SYNCHRON Systems Bilirubin Calibrator, is intended for quantitative determination of direct (conjugated) bilirubin () concentration in human serum or plasma. CLINICAL SIGNIFICANCE Direct bilirubin measurements are used in the diagnosis and treatment of liver, hemolytic, hematological, and metabolic disorders, including hepatitis and gall bladder block. METHODOLOGY reagent is used to measure concentration by a timed endpoint diazo method. 1,2 In the reaction, combines with diazo to form azobilirubin. The SYNCHRON CX System(s) automatically proportions the appropriate sample and reagent volumes into the cuvette. The ratio used is one part sample to 32 parts reagent. The system monitors the change in absorbance at 560 nanometers. This change in absorbance is directly proportional to the concentration of in the sample and is used by the System to calculate and express the concentration. CHEMICAL REACTION SCHEME SPECIMEN TYPE OF SPECIMEN Biological fluid samples should be collected in the same manner routinely used for any laboratory test. 3 Freshly drawn serum or plasma are the preferred specimens. Acceptable anticoagulants are listed in the PROCEDURAL NOTES section of this chemistry information sheet. Whole blood or urine are not recommended for use as a sample. JANUARY 2008 Page 1 of 10

SPECIMEN STORAGE AND STABILITY 1. Tubes of blood are to be kept closed at all times and in a vertical position. It is recommended that the serum or plasma be physically separated from contact with cells within two hours from the time of collection. 4 2. Separated serum or plasma should not remain at room temperature longer than 8 hours. If assays are not completed within 8 hours, serum or plasma should be stored at +2 C to +8 C. If assays are not completed within 48 hours, or the separated sample is to be stored beyond 48 hours, samples should be frozen at -15 C to -20 C. Frozen samples should be thawed only once. Analyte deterioration may occur in samples that are repeatedly frozen and thawed. 4 3. Bilirubin is photosensitive. Protect samples from light. Additional specimen storage and stability conditions as designated by this laboratory: SAMPLE VOLUME A filled 0.5 ml sample cup is the optimum volume. For optimum volume in primary tube samples, refer to Primary Sample Tube Chart Template (P/N 248511) for minimum volume requirements. CRITERIA FOR UNACCEPTABLE SPECIMENS Refer to the PROCEDURAL NOTES section of this chemistry information sheet for information on unacceptable specimens. Criteria for sample rejection as designated by this laboratory: PATIENT PREPARATION Special instructions for patient preparation as designated by this laboratory: JANUARY 2008 Page 2 of 10

SPECIMEN HANDLING Special instructions for specimen handling as designated by this laboratory: REAGENTS CONTENTS Each kit contains the following items: Two Direct Bilirubin Reagent Cartridges (2 x 200 tests) or (2 x 300 tests) VOLUMES PER TEST Sample Volume 10 µl Total Reagent Volume 320 µl Cartridge Volumes A 310 µl B 10 µl C REACTIVE INGREDIENTS REAGENT CONSTITUENTS Sulfanilic acid HCl Sodium nitrite 27 mmol/l 51 mmol/l 0.12 mmol/l Also non-reactive chemicals necessary for optimal system performance. CAUTION Avoid skin contact with reagent. Use water to wash reagent from skin. MATERIALS NEEDED BUT NOT SUPPLIED WITH REAGENT KIT SYNCHRON Systems Bilirubin Calibrator At least two levels of control material Deionized water (low level calibrator) Human serum albumin (azide free) REAGENT PREPARATION No preparation is required. JANUARY 2008 Page 3 of 10

ACCEPTABLE REAGENT PERFORMANCE The acceptability of a reagent is determined by successful calibration and by ensuring that quality control results are within your facility s acceptance criteria. REAGENT STORAGE AND STABILITY reagent, when stored unopened at room temperature, will obtain the shelf-life indicated on the cartridge label. 5 Once opened, the reagent is stable for 30 days at +2 C to +8 C unless the expiration date is exceeded. DO NOT FREEZE. Reagent storage location: CALIBRATION CALIBRATOR REQUIRED SYNCHRON Systems Bilirubin Calibrator: The SYNCHRON Systems Bilirubin calibrator matrix is derived from stabilized human defibrinated serum. The assigned value of this calibrator can be traced directly to NIST Standard 916. Deionized water (low level calibrator) CALIBRATOR PREPARATION No preparation is required. CALIBRATOR STORAGE AND STABILITY If unopened, the SYNCHRON Systems Bilirubin Calibrator may be stored at -15 C to -20 C until the expiration date printed on the calibrator ampule. Opened calibrators that are resealed and stored at +2 C to +8 C are stable for 24 hours unless the expiration date is exceeded. CAUTION Because this product is of human origin, it should be handled as though capable of transmitting infectious diseases. Each serum or plasma donor unit used in the preparation of this material was tested by United States Food and Drug Administration (FDA) approved methods and found to be negative for antibodies to HIV and HCV and nonreactive for HbsAg. Because no test method can offer complete assurance that HIV, hepatitis B virus, and hepatitis C virus or other infectious agents are absent, this material should be handled as though capable of transmitting infectious diseases. This product may also contain other human source material for which there is no approved test. The FDA recommends such samples to be handled as specified in Centers for Disease Control s Biosafety Level 2 guidelines. 6 JANUARY 2008 Page 4 of 10

Calibrator storage location: CALIBRATION INFORMATION 1. The system must have a valid calibration curve in memory before control or patient samples can be run. 2. Under typical operating conditions the reagent cartridge must be calibrated every 14 days or with certain parts replacements or maintenance procedures, as defined in the SYNCHRON CX Operating Instructions manual. This assay has within-lot calibration available. Refer to Section 6 of the SYNCHRON CX Operating Instructions manual for information on this feature. 3. For detailed calibration instructions refer to Section 6 of the SYNCHRON CX Operating Instructions manual. 4. The system will automatically perform checks on the calibration and produce data at the end of calibration. In the event of a failed calibration, the data will be printed with error codes and the system will alert the operator of the failure. The explanation of these error codes can be found in Appendix G of Section 10 in the SYNCHRON CX Operating Instructions manual. TRACEABILITY For Traceability information refer to the Calibrator instructions for use. QUALITY CONTROL At least two levels of control material, normal and abnormal, should be analyzed daily. In addition, these controls should be run with each new calibration, with each new reagent cartridge and after specific maintenance or troubleshooting procedures as detailed in the SYNCHRON CX System(s) Operations Manual. More frequent use of controls or the use of additional controls is left to the discretion of the user based on work load and work flow. The following controls should be prepared and used in accordance with the package inserts. Discrepant quality control results should be evaluated by your facility. Table 1.0 Quality Control Material CONTROL NAME STORAGE TESTING PROCEDURE(S) 1. If necessary, load the reagent onto the system as directed in Section 6 of the SYNCHRON CX Operating Instructions manual. JANUARY 2008 Page 5 of 10

2. After reagent load is completed, calibration may be required. Refer to Section 6 of the SYNCHRON CX Operating Instructions manual for details of the calibration procedure. 3. Program samples and controls for analysis as directed in Section 6 of the SYNCHRON CX Operating Instructions manual. 4. After loading samples and controls onto the system, follow the protocols for system operation as directed in Section 6 of the SYNCHRON CX Operating Instructions manual. CALCULATIONS The system performs all calculations internally to produce the final reported result. SYNCHRON CX4/5 Systems do not calculate the final result for sample dilutions made by the operator. In these cases, the result produced by the instrument must be multiplied by the dilution factor before reporting the final result. SYNCHRON CX4CE/5CE/7 Systems (including the CX DELTA and CX PRO Systems) will calculate the final result for sample dilutions made by the operator when the dilution factor is entered into the system during sample programming. REPORTING RESULTS REFERENCE INTERVALS Each laboratory should establish its own reference intervals based upon its patient population. The reference intervals listed below were taken from literature. 7 Table 2.0 Reference intervals INTERVALS CONVENTIONAL UNITS S.I. UNITS Literature Serum or Plasma 0.0 0.2 mg/dl 0.0 3.4 µmol/l INTERVALS CONVENTIONAL UNITS S.I. UNITS Laboratory Refer to References (8,9,10) for guidelines on establishing laboratory-specific reference intervals. Additional reporting information as designated by this laboratory: PROCEDURAL NOTES ANTICOAGULANT TEST RESULTS If plasma is the sample of choice, the following anticoagulants were found to be compatible with this method based on a study of 20 healthy volunteers: JANUARY 2008 Page 6 of 10

Table 3.0 Acceptable Anticoagulants ANTICOAGULANT LEVEL TESTED FOR IN VITRO INTERFERENCE AVERAGE PLASMA-SERUM BIAS (mg/dl) @ +37 C Ammonium Heparin 29 Units/mL NSI a Lithium Heparin 29 Units/mL NSI Sodium Heparin 29 Units/mL NSI EDTA 3 mg/ml NSI Sodium Citrate 6.6 mg/ml NSI Potassium Oxalate/Sodium Fluoride a NSI = No Significant Interference (within ±0.3 mg/dl or 10%). LIMITATIONS 4.0 / 5.0 mg/ml NSI 1. The SYNCHRON Systems Direct Bilirubin method is an improved method which shows enhanced specificity for some conjugated fractions. However, no diazo direct bilirubin is able to estimate completely all possible conjugated bilirubin fractions. 2. Because the source of bilirubin in the SYNCHRON Systems Bilirubin Calibrator is not of human origin, the setpoint is value assigned to obtain good agreement on human samples with referee methods. This is implemented by including a factor in the database which is applied to the reported result. Therefore, the calibrator will not recover its setpoint value when run as sample. 3. Beckman Coulter has not validated this method for neonatal direct bilirubin values. Each laboratory should establish a reference range for neonatal values. INTERFERENCES 1. The following substances were tested for interference with this methodology: Table 4.0 Interferences SUBSTANCE SOURCE LEVEL TESTED OBSERVED EFFECT ON ANALYTE a Bilirubin Bovine (unconjugated) 30 mg/dl NSI b Lipemia Intralipid c (4+) 500 mg/dl -0.25 @ 0.5 mg/dl Ascorbic Acid NA d 3.0 mg/dl NSI Sodium Azide NA 5.0 mg/dl NSI a Plus (+) or minus (-) signs in this column signify positive or negative interference. b NSI = No Significant Interference (within ±0.30 mg/dl or 10%). c Intralipid is a registered trademark of KabiVitrum, Inc., Clayton, NC 27250. d NA = Not applicable. 2. Interference from hemoglobin is a combination of chemical and spectral interference. For elevated direct bilirubin values, hemoglobin interference will change from a positive to a negative bias. JANUARY 2008 Page 7 of 10

Table 5.0 Hemoglobin Interferences a Hemoglobin SUBSTANCE SOURCE RBC hemolysate Plus (+) or minus (-) signs in this column signify positive or negative interference. LEVEL TESTED MAXIMUM OBSERVED EFFECT ON ANALYTE a (4+) 400 mg/dl +0.3 @ 0.5 mg/dl (2+) 200 mg/dl -0.3 @ 3.1 mg/dl (2+) 200 mg/dl -0.9 @ 8.3 mg/dl 3. Refer to References (11,12,13) for other interferences caused by drugs, disease and preanalytical variables. PERFORMANCE CHARACTERISTICS ANALYTIC RANGE The SYNCHRON CX System(s) method for the determination of this analyte provides the following analytical ranges: Table 6.0 Analytical Range CONVENTIONAL UNITS S.I. UNITS Serum or Plasma 0.1 10 mg/dl 1.7 171 µmol/l The low end of the analytical range represents the minimum level of detection. Samples with concentrations exceeding the high end of the analytical range should be diluted with human serum albumin (azide free) and reanalyzed. REPORTABLE RANGE (AS DETERMINED ON SITE): Table 7.0 Reportable Range CONVENTIONAL UNITS S.I. UNITS EQUIVALENCY Equivalency was assessed by Deming regression analysis of patient samples to accepted clinical methods. Serum or plasma: a Y (SYNCHRON CX Systems) a = 1.084X - 0.02 N = 100 MEAN (SYNCHRON CX Systems) a = 2.35 RANGE OF Y = 0-11 MEAN (SYNCHRON AS ) = 2.17 RANGE OF X = 0-10 CORRELATION COEFFICIENT (r) = 0.9859 Data shown was collected using the SYNCHRON CX4/CX5 Systems. Equivalency between SYNCHRON CX Systems has been established by Deming regression analysis to SYNCHRON CX4/CX5 Systems. Refer to References (14) for guidelines on performing equivalency testing. JANUARY 2008 Page 8 of 10

PRECISION A properly operating SYNCHRON CX System(s) should exhibit precision values less than or equal to the maximum performance limits in the table below. Maximum performance limits were derived by an examination of the precision of various methods, proficiency test summaries, and literature sources. Table 8.0 Maximum Performance Limits a TYPE OF PRECISION mg/dl 1 SD µmol/l CHANGEOVER VALUE a mg/dl µmol/l Within-run Serum/Plasma 0.15 2.6 3.0 52.0 5.0 Total Serum/Plasma 0.23 3.9 3.0 52.0 7.5 % CV When the mean of the test precision data is less than or equal to the changeover value, compare the test SD to the SD guideline given above to determine the acceptability of the precision testing. When the mean of the test precision data is greater than the changeover value, compare the test % CV to the guideline given above to determine acceptability. Changeover value = (SD guideline/cv guideline) x 100. Comparative performance data for the SYNCHRON CX System(s) evaluated using the NCCLS Proposed Guideline EP5-T2 appears in the table below. 15 Each laboratory should characterize their own instrument performance for comparison purposes. Table 9.0 NCCLS EP5-T2 Precision Estimate Method a TYPE OF IMPRECISION Within-run Total No. Systems No. Data Points a Test Mean Value (mg/dl) EP5-T2 Calculated Means & Point Estimates SD % CV Control Level 1 1 80 0.85 0.03 3.53 Control Level 2 1 80 4.29 0.04 0.93 Control Level 3 1 80 5.47 0.05 0.91 Control Level 1 2 160 0.85 0.03 3.53 Control Level 2 2 160 4.29 0.05 1.17 Control Level 3 2 160 5.47 0.07 1.28 The serum/plasma point estimate is based on the pooled data from 2 systems, each run for 20 days, 2 runs per day, 2 observations per run on instruments operated and maintained according to the manufacturer s instructions. NOTICE These degrees of precision and equivalency were obtained in typical testing procedures on the SYNCHRON CX System(s) and are not intended to represent the performance specifications for this reagent. ADDITIONAL INFORMATION For more detailed information on SYNCHRON CX Systems, refer to the appropriate SYNCHRON CX manual. SHIPPING DAMAGE If damaged product is received, notify your Beckman Coulter Clinical Support Center. JANUARY 2008 Page 9 of 10

REFERENCES 1. Malloy, H. T., Evelyn, K. A., J. Biol. Chem., 119 481 (1937). 2. Winkleman, J., Cannon, D. C., Jacobs, S. L., Clinical Chemistry: Principles and Technics, 1061, Harper and Row, Hagerstown, MD (1974). 3. Tietz, N. W., "Specimen Collection and Processing; Sources of Biological Variation", Textbook of Clinical Chemistry, 2nd Edition, W. B. Saunders, Philadelphia, PA (1994). 4. National Committee for Clinical Laboratory Standards, Procedures for the Handling and Processing of Blood Specimens, Approved Guideline, NCCLS publication H18-A, Villanova, PA (1990). 5. "USP XXII, NF XVII", United States Pharmacopeial Convention, Inc., Rockville, MD (1990). 6. CDC-NIH manual, Biosafety in Microbiological and Biomedical Laboratories, U.S. Government Printing Office, Washington, D.C. (1984). 7. Tietz, N. W., Clinical Guide to Laboratory Tests, 2nd Edition, W. B. Saunders, Philadelphia, PA (1990). 8. National Committee for Clinical Laboratory Standards, How to Define, Determine, and Utilize Reference Intervals in the Clinical Laboratory, Approved Guideline, NCCLS publication C28-A, Villanova, PA (1994). 9. Tietz, N. W., ed., Fundamentals of Clinical Chemistry, 3rd Edition, W. B. Saunders, Philadelphia, PA (1987). 10. Henry, J. B., Clinical Diagnosis and Management by Laboratory Methods, 18th Edition, W. B. Saunders Company, Philadelphia, PA (1991). 11. Young, D. S., Effects of Drugs on Clinical Laboratory Tests, 3rd Edition, AACC Press, Washington, D.C. (1990). 12. Friedman, R. B., Young, D. S., Effects of Disease on Clinical Laboratory Tests, 2nd Edition, AACC Press, Washington, D.C. (1989). 13. Young, D. S., Effects of Preanalytical Variables on Clinical Laboratory Tests, AACC Press, Washington, D.C. (1993). 14. National Committee for Clinical Laboratory Standards, Method Comparison and Bias Estimation Using Patient Samples, Tentative Guideline, NCCLS publication EP9-T, Villanova, PA (1993). 15. National Committee for Clinical Laboratory Standards, Precision Performance of Clinical Chemistry Devices, Tentative Guideline, 2nd Edition, NCCLS publication EP5-T2, Villanova, PA (1992). Beckman Coulter Ireland Inc., Mervue Business Park, Mervue, Galway, Ireland (353 91 774068) Beckman Coulter, Inc., 4300 N. Harbor Blvd., Fullerton, CA 92835 JANUARY 2008 Page 10 of 10