performance and throughput

Similar documents
HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

Agilent 6430 Triple Quadrupole LC/MS System

The clearly better choice

Thermo Scientific TSQ Quantum Access MAX

Pharmaceutical LC/MS Solutions from Agilent Technologies

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Agilent 6500 Series Q-TOF LC/MS System

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Agilent 6400 Series. System. Concepts Guide. The Big Picture. Agilent Technologies

Agilent solutions for contract research and manufacturing organizations

TurboMass GC/MS Software

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Agilent 1260 Infinity II LC ASPIRE TO NEW LEVELS OF EFFICIENCY EVERY DAY IN EVERY WAY

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

ICP Expert software. Technical Overview. Introduction

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Agilent OpenLAB CDS. Manage your chromatography better than ever before

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Method Translation in Liquid Chromatography

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Application Note. Abstract. Authors. Introduction. Environmental

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Agilent CE and CE/MS Solutions FLEXIBILITY AND RELIABILITY TO AMPLIFY YOUR FINDINGS

Purification Workflow Management

The LC-MS/MS Workhorse. SCIEX 4500 Series Mass Spectrometers

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

QUANLYNX APPLICATION MANAGER

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

MultiQuant Software Version 3.0

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

THE SOURCE OF NEW POSSIBILITIES

Clarus 600. Gas Chromatograph/Mass Spectrometers. your GC/MS results. better. faster.

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

REGULATORY PESTICIDE ANALYSIS JUST GOT EASIER. QSight Pesticide Analyzer

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

NATURALLY BETTER CHROMATOGRAPHY SOLUTIONS. Clarus Gas Chromatographs Clarus 680/580/480

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

ACQUITY UPLC. I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE

LC/MS. Why is it the fastest growing analytical technique?

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Antibody Analysis by ESI-TOF LC/MS

HPLC/FLASH Purification ADVANCE THE PACE OF YOUR DISCOVERY TO ACHIEVE THE RESULTS OF TOMORROW

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Agilent Food Profiling Solutions ASSESS FOOD QUALITY AND POINT OF ORIGIN

LC/MS/MS Solutions for Biomarker Discovery QSTAR. Elite Hybrid LC/MS/MS System. More performance, more reliability, more answers

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Designed for the Modern Chromatography Lab. Agilent OpenLab CDS

Genotoxicity is the property of a compound

SCION GC Series. The Gas Chromatographers Choice for Separations

BÜCHI Labortechnik AG

The Agilent 5975C Series GC/MSD Performance, productivity and confidence. Our measure is your success.

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED.

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

Peptide Mapping: A Quality by Design (QbD) Approach

ENHANCED MS WITH THE TURN OF A KEY

Changing the Game in LC-MS/MS. New Tools for Unprecedented Performance in Residue Analysis. Dr. Thomas Glauner

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Tony Mire-Sluis Vice President, Corporate, Product and Device Quality Amgen Inc

NovoCyte Flow Cytometer

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Agilent Sample Preparation Portfolio ACCURATE, REPRODUCIBLE RESULTS RIGHT FROM THE START

Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules

Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

CaptiveSpray nanobooster

HYDROGEN AS A CARRIER GAS. Gas Chromatography new frontiers: can Hydrogen substitute Helium?

Highly Confident Peptide Mapping of Protein Digests Using Agilent LC/Q TOFs

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Qualification of High-Performance Liquid Chromatography Systems

Certified Reference Material - Certificate of Analysis

SoftMax Pro 5 Software

PinAAcle 500. Flame Atomic Absorption Spectrometer

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

AGILENT CUSTOMER EDUCATION CATALOG

Thermo Scientific icap RQ ICP-MS. Simplicity, productivity and robustness for routine labs

Transcription:

Agilent 6100 Series Single Quadrupole LC/MS Systems CLEARLY BETTER performance and throughput with day-after-day reliability

Step up to clearly better sensitivity, selectivity, and high-quality spectral information From routine QC to research applications, Agilent 6100 Series Single Quadrupole LC/MS Systems deliver unmatched analytical performance and proven day-after-day reliability. Available with performance characteristics to match your needs and budget, they offer best-in-class data quality in a space-saving benchtop package. For more than 40 years, Agilent s single-quadrupole technology has earned a reputation for robustness and dependability in pharmaceutical and chemical analysis laboratories around the world. To maximize your return on investment, the performance capabilities of Agilent 6100 Series LC/MS systems can be easily upgraded to keep pace with your future requirements. The easy-to-use 6100 Series platform gives you the capability to: Rapidly screen compounds and confirm molecular weights Purify target compounds in complex mixtures Quantitate target compounds Identify impurities Performance Upgrade Path To maximize your return on investment, the performance capabilities of Agilent 6100 Series LC/MS systems can be easily upgraded to keep pace with your future requirements. Enter the world of LC/MS with the affordable and very easyto-use 6120. Upgrade to the 6130 for higher flexibility and performance. Or move up to the 6150 for unsurpassed data quality and the additional option of Agilent Jet Stream technology. 1200 Infinity Series LC with - DAD 6120 6130 Easiest to Use 6150 Most Flexible Highest Performance Throughput and Sensitivity 2

Unmatched analysis speed boosts productivity Faster acquisition speeds let you take full advantage of the higher throughput of UHPLC. Ultra-fast ion polarity switching lets you obtain both positive and negative spectra, providing maximum information from a single injection. Advanced analytical capabilities increase confidence Even at the fastest scan speeds, you get excellent spectral quality with accurate isotope ratios for more confident compound identification and confirmation. Variable-energy, in-source, collision-induced dissociation (CID) provides valuable structural information. Multi-signal capability lets you acquire more information from a single injection. Simple, intuitive operation saves time and improves results Intuitive Agilent OpenLAB CDS ChemStation Edition software lets you set up and control the LC and MS from a single screen. Agilent s powerful Autotune feature boosts productivity by eliminating the need for manual recalibration. Comprehensive automation features allow multi-user, walk-up sample submission and unattended operation. Maintain Unit Resolution at UHPLC Scan Speeds 118 622 922 115 120 620 625 920 925 Agilent 6100 Series Single Quadrupole LC/MS Systems 6120 Budget-friendly and very easy to use with the Agilent 1220 Infinity LC, a perfect workhorse addition for labs just getting into LC/MS. 6130 Highly flexible, high-performance solution ideal for any quantitation application, offering the widest mass range and 1 pg sensitivity and the optional Agilent Jet Stream technology for higher sensitivity. 6150 Unsurpassed data quality for UHPLC and high-throughput screening and qualitative applications, with Agilent Jet Stream technology for unmatched sensitivity and the fastest scan speeds. 15000 14000 13000 12000 11000 Injection spike Solvent Blank 200 fg Reserpine Unmatched sensitivity and broader ionization capabilities at LC flow rates up to 2 ml/min for ultra-fast chromatography and high-throughput applications. Five replicate injections of 200 fg reserpine on-column with Agilent Jet Stream technology. Data collected using a 6150 system. 10000 9000 8000 7000 2 4 6 8 10 min To learn more about Agilent 6100 Series LC/MS systems, visit www.agilent.com/chem/singlequad 3

Hardware innovations and optimized components add up to clearly better performance The ion sources, ion optics, vacuum system, and electronics for the 6100 Series LC/MS instruments have been optimized to deliver outstanding speed, sensitivity, and reproducibility plus, of course, legendary Agilent reliability. The ideal MS complement to the Agilent 1200 Infinity Series LC Systems The 6100 Series LC/MS integrates seamlessly with all Agilent 1200 Infinity Series LC Systems. It lets you take full advantage of the faster speed of UHPLC separations so you can capture all the information in even the narrowest LC peaks. For maximum analytical versatility, the system delivers superior sensitivity, reproducibility, and spectral quality even at very high flow rates and over a wide range of mobile-phases and mobile-phase additives. Multi-signal capability lets you analyze more compounds per run Within a single injection, you can perform: Polarity switching to obtain both positive and negative spectra. Variable energy, in-source, collision-induced dissociation (CID) for more structural information. Selected ion monitoring (SIM) to quantitate target compounds or find trace compounds, while also scanning to obtain full spectra. Interchangeable ion sources with patented orthogonal nebulization and high-capacity, counter-flow drying gas enhance sensitivity and versatility. Optimized ion optics yield excellent ion transmission across the mass range, making tuning easy. Fast electronics enable allow scan ultra-fast speeds scan up speeds to and 10,000 rapid u/sec polarity and switching. polarity switching speeds as short as 20 ms. High-sensitivity detector provides excellent signal amplification, low noise, and predictable tuning. + + + + + + + + + + + + + + + + + + Metallized capillary enables fast ion polarity switching for broad compound detection in a single analysis. Precision quadrupole and fast, stable electronics ensure stable mass assignments and superior mass resolution. 4

Ultra-fast ion polarity switching increases productivity Using scan-by-scan switching between positive and negative ionization, you can rapidly screen unknown samples without having to determine the optimum polarity in advance. Standard in all three 6100 LC/MS systems, this powerful capability makes it possible to obtain high-quality positive and negative spectra even with ultra-fast chromatography and narrow chromatographic peaks. Widest range of ionization sources Agilent offers the industry s widest selection of interchangeable ion sources. So no matter what class of molecule you re analyzing, you can match ionization mode and instrument to your compounds of interest. Choices include: Electrospray (ESI) at standard, microliter, and nanoliter flow rates for biological macromolecules and small polar molecules. Atmospheric pressure chemical ionization (APCI) for less polar and non-polar molecules. Atmospheric pressure photoionization (APPI) for compounds that ionize poorly by ESI and APCI. Multimode ESI/APCI innovative Agilent technology that enables true simultaneous electrospray ionization and atmospheric pressure chemical ionization, eliminating the need to run samples twice to ensure all components are identified. Agilent Jet Stream Technology Available on the 6130 and 6150 systems, innovative thermal gradient focusing enhances sensitivity by maximizing nebulization and desolvation and reducing ion dispersion at conventional and capillary flow rates delivering many more ions to the mass spectrometer, while simultaneously reducing the number of neutral solvent clusters. The result is higher intensity signals with lower RSDs at the limit of detection for a broader range of compounds. Super-heated sheath gas Nozzle voltage The collimated thermal confinement zone creates a dramatically brighter source LC sample inlet Nebulizing gas MS inlet Heated drying gas Resistive sampling capillary To learn more about Agilent 6100 Series LC/MS systems, visit www.agilent.com/chem/singlequad 5

Simpler, more powerful software and faster answers Agilent OpenLAB CDS ChemStation Edition LC/MS software integrates control of all LC and MS operating parameters under a single, intuitive interface. Featuring automated setup and streamlined data acquisition, data review, and result reporting, the software enhances all aspects of system operation and ensures better, more meaningful data from every experiment. Exceptionally easy setup Whether you are new to LC/MS or a seasoned expert, OpenLAB ChemStation Edition LC/MS software simplifies and speeds the operation of your 6100 Series LC/MS system. Autotune tuning and calibration and automated calibrant delivery makes setup quick and easy; of course, you can also set parameters manually. Sequencing software helps you quickly create and modify sequences, chain sequences together, and change the order of samples while a sequence runs. Convenient Peak Purity tool displays UV and mass spectral data together to better identify chromatographic peaks containing unresolved compounds; this helps you develop separation methods and choose quantitation ions without having to refine the separation. Exceptionally fast answers For both qualitative and quantitative analysis, OpenLAB ChemStation Edition LC/MS software gives you a shorter path to the information you re looking for. Choose from a variety of quantitation methods, quantitate using both UV and MS data in a single calibration table, and use batch review software to evaluate and update results. Report results using preconfigured formats or customize using Report Builder. Use the optional NIST mass-spectral library search software to rapidly identify compounds by matching MS spectra with user-created library spectra. Use advanced, integrated networking capabilities to control the system and review results from any location. Simple and completely automated tuning. MassHunter software adds analytical power Agilent MassHunter Workstation software was designed to make your MS analyses faster, easier, and more productive. The software incorporates advanced data-mining and processing tools that let you rapidly and accurately extract all available information from the compounds in your samples not just peaks and data points but answers. In addition, MassHunter software enables data acquisition and instrument control for your Agilent TOF, Q-TOF, and triple-quadrupole instruments. Automatic translation into MassHunter Workstation software lets you standardize all your LC/MS data processing and puts advanced data analysis and reporting capabilities at your command. 6

Easier multi user sample submission Optional LC/MS Easy Access software makes it easy for multiple users to submit samples for molecular weight confirmation and purification. Authorized users simply enter some basic sample information and a molecular formula or expected molecular weight and select from a menu of preconfigured methods. Easy Access software schedules the analysis, reports the sample status, and confirms the molecular weight or fractionates the sample. Analytical Studio Reviewer speeds data review Optional Analytical Studio Reviewer software complements the LC/MS Easy Access software by letting you quickly and easily review results. From any browser-equipped desktop, you can compare samples, confirm both UV and MS peak purity, trouble shoot syntheses, and design custom reports. The software includes simple generic settings for easy setup and is also fully customizable for more sophisticated users. Automated printing and email distribution make it easy to share data and analyze results. Results are displayed for an entire well plate, with color coding showing results at a glance. Simply click on a sample well to display more detailed mass spectral information. You can edit and override summary results by regenerating a new file with modifications based on chemical knowledge eliminating the need to re-run the sample. Time-saving compliance features and products Agilent s compliance features enable you to validate hardware, software, methods, and data at the lowest possible cost. We also offer a selection of optional products and services to make it easier to meet regulatory requirements. Analytical Studio Reviewer software simplifies data review, synthesis troubleshooting, and report generation. To learn more about Agilent 6100 Series LC/MS systems, visit www.agilent.com/chem/singlequad 7

High-throughput compound screening and molecular weight confirmation Agilent 6100 Series LC/MS systems give you the answers you need to make faster, more confident decisions about the next steps in your drug development process. Advanced capabilities such as fast MS scanning, multi-signal acquisition, ultra-fast ion polarity switching, and short injection-to-injection cycle times, help you avoid analysis bottlenecks. And with software tools for fast sample submission, molecular weight confirmation, and reporting, they make it simple and efficient to share results. Compatible with ultra-fast chromatography for greater throughput The ability to obtain high-quality MS data across chromatographic peaks as narrow as one second-wide enables maximum productivity, without compromising confidence in your results. Reduced time between analyses With fast electronics and short after-run recovery time, injectionto-injection cycle time is less than 10 seconds. Full support for high-throughput samplers All Agilent 6100 systems are compatible with 1290 Infinity LC Injectors HTC and HTS, giving you extra flexibility in your choice of sample vessels. More sizes and types of vessels can be used, allowing you to increase your sample capacity and laboratory throughput. 1200000 1000000 800000 600000 400000 200000 0 #1 #2 #3 #4 Peak Width, sec Peak #1: 1.02 Peak #2: 0.96 Peak #3: 0.91 Peak #4: 1.1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 min Multi-signal data acquisition maximizes throughput for compound screening and molecular weight confirmation. Fast scanning and rapid polarity switching can adequately sample even sub-1-second LC peaks, while maintaining correct isotope ratios. 200000 175000 150000 125000 100000 75000 50000 25000 0 #1 #2 #3 #4 Peak Width, sec Peak #1: 1.08 Peak #2: 0.78 Peak #3: 0.67 Peak #4: 0.88 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 min 100 80 60 40 285.0 287.0 Peak #2, positive ion Isotope ratios Theory Observed M/Z Theory Obs. 286 13.3 11.5 287 37.7 35.2 288 4.9 4.6 289 1.9 2.2 100 80 60 40 282.9 285.0 Peak #2, negative ion Isotope ratios Theory Observed M/Z Theory Obs. 284 13.3 13.6 285 37.7 36.0 286 4.9 4.1 287 1.9 2.3 20 0 286.0 288.0 289.0 0 285 286 287 288 289 290 m/z 283 284 285 286 288 289 Positive mode mass spectrum showing accurate C 13, Cl 35, and Cl 37 isotope ratios. 20 284.0 286.0 287.0 m/z Negative mode mass spectrum showing accurate C 13, Cl 35, and Cl 37 isotope ratios. 8

High-throughput, high-confidence impurity detection Agilent 6100 Series Single Quadrupole LC/MS Systems are excellent platforms for confirming the presence and quantity of impurities in foods and consumer products. Best-in-class sensitivity plus productivity features such as ultra-fast ion polarity switching, fast scanning, powerful quantitation and reporting software, and the available multimode source add certainty and speed to every step of your most demanding impurity analysis. Multi-signal capability provides more information Multi-signal capability gives you more information about your sample including any impurities present in a single run. Using ultra-fast ion polarity switching, you can rapidly screen for impurities without having to determine the optimum ionization polarity in advance. You can also change the CID energy to increase spectral information, using low-energy CID to maximize the molecular ion and high-energy CID to generate more fragments. CID spectra can be saved and matched against spectra in user-created libraries. Multimode source increases productivity Agilent s multimode source helps you to identify a broad range of compounds, regardless of the technique to which they best respond all in a single analysis. Ultra-fast scanning increases impurity detection The 6100 series single quadrupole LC/MS systems offer fast scanning capabilities, making it the ideal choice for UHPLC applications. By acquiring more data points across narrow peaks, you can be sure you re not missing anything. Fast, easy quantitation of impurities Quantitation is easy to set up, and ChemStation s Peak Purity software can be used to assist in the selection of quantitation ions, using automatic calculations and common quantitation methods. All quantitation instructions can be saved as methods for unattended analyses and reporting. abundance 100 H 3 C N OH 166.0 [M+H]+ 80 H 3 C O 60 C 9 H 11 NO 2 p-dimethylaminobenzoic acid 40 20 0 151.0 103.4 167.0 90 100 110 120 130 140 150 160 170 m/z Fast scanning improves impurity detection with fast chromatography. Analysis of octyl-dimethyl-p-aminobenzoic acid (OD-PABA) on an Agilent 1260 Infinity LC and Agilent 6150 Single Quadrupole LC/MS found many possible impurities and degradants using the standard scan speed. However, the compound p-dimethylbenzoic acid, a known degradant of OD-PABA, was only seen clearly at the fastest scan speed.

Turnkey solution for high-throughput, high-yield purification Agilent can provide a complete purification system optimized to deliver the purest fractions based on Agilent s 1200 Infinity Series Purification Systems, diode-array detector (DAD), and 6100 Series LC/MS. The turnkey system also includes a delay sensor and intelligent, mass-based fraction collection software. Better timing improves fraction purity The fraction collection software and delay sensor accurately assess the delay time between the DAD and LC/MS to ensure precise triggering of fraction collection. There is no loss of valuable fractions and minimal collection of unwanted material. Review and optimize purification conditions The complete Agilent purification system includes fraction review, which can be used to review a run to find the best LC/MS operating conditions and the best masses to trigger fraction collection. Integrated safety features free you to perform other tasks Agilent s purification system automatically detects and manages solvent leaks. With this added safety feature, the system can operate completely unattended. Real-time data processing yields purer fractions Because data processing occurs in real time at the MS, fraction collection decisions are made immediately, with no delays in sending data to a separate computer for action. Fraction Review in data analysis allows the user to examine fraction collection results. Note that the blue bars above show the fraction collected. 10

High-throughput target compound analysis Agilent 6130 and 6150 systems give you the ability to confidently confirm the presence and quantity of low-level target compounds, even in complex mixtures. Outstanding sensitivity, as well as the wide choice of ion sources, multi-signal capability, and easy-to-use software for quantitation and reporting assure success with even the most demanding forensics, drugs-of-abuse, and environmental analyses. Quantitate, identify, and confirm all in a single analysis In many cases, Agilent s superior sensitivity allows you to perform target compound analyses in scan rather than SIM mode. This allows you to identify target and non-target compounds at the same time. Within a single injection you can obtain both positive and negative spectra, vary CID energy to obtain more structural information, and collect scan and SIM data. With fast ion polarity switching, you can rapidly screen for unknowns without having to determine the optimum ionization mode in advance. For compounds that ionize well in both modes, you get both positive and negative spectra, increasing the confidence in your results. x 10 4 3.0 2.5 2.0 7-aminoflunitrazepam Halazepam Diazepam Nordiazepam Desalkylflurazepam 1.5 1.0 Triazolam Alprazolam Flunitrazepam Temazepam 0.5 Flurazepam Clonazepam 0 10 11 12 13 14 15 16 Time (min) x10 4 6.0 12.687 Internal standard Abundance 4.0 2.0 12.684 Internal standard qualifier 14.164 Temazepam 14.159 Temazepam qualifier 0.0 12 14 16 min Analysis of benzodiazepines in scan mode. Extracted ion chromatograms can be used to quantitate target analytes. Confirming ions increases confidence in results. 11

Add the richness of mass spectral information to your data set If your lab is ready to step up to unprecedented sensitivity, selectivity, and high-quality spectral information, it s time to look at Agilent s 6100 Series Single Quadrupole LC/MS solutions. Whether you re doing routine testing or discovery research, we can help you select an affordable, easy-to-own system that meets your analytical needs today and can grow with you into the future. Software and services that support the regulated lab www.agilent.com/chem/singlequad www.agilent.com/chem/store www.agilent.com/chem/contactus 1-800-227-9770 agilent_inquiries@agilent.com info_agilent@agilent.com inquiry_lsca@agilent.com Research use only. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Agilent Technologies, Inc. 2013 Printed in USA, August 26, 2013 5990-8369EN MassHunter software provides comprehensive tools to help you address the requirements of GLP/GMP and 21 CFR Part 11 compliance. With built-in audit trails, multi-user login security, user permissions, and electronic signatures, the software makes it easier for your laboratory to operate in a regulated environment. Agilent also offers a complete suite of Installation and Operation Qualification services to shorten the time between installation and running critical samples. The Agilent Value Promise: 10 years of guaranteed performance In addition to our continually evolving products, Agilent offers the industry s only 10-year value guarantee. Agilent guarantees you at least 10 years of instrument use from your date of purchase, or we will credit you with the residual value of that system toward an upgraded model. It s our way of assuring you of a safe purchase now and protecting your investment.