NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778)

Similar documents
Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

AB SCIEX TripleTOF 5600 SYSTEM. High-resolution quant and qual

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

The LC-MS/MS Workhorse. SCIEX 4500 Series Mass Spectrometers

Agilent 6430 Triple Quadrupole LC/MS System

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

TurboMass GC/MS Software

Thermo Scientific TSQ Quantum Access MAX

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Agilent 6400 Series. System. Concepts Guide. The Big Picture. Agilent Technologies

Pharmaceutical LC/MS Solutions from Agilent Technologies

MultiQuant Software Version 3.0

Tyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1

Agilent solutions for contract research and manufacturing organizations

MasterView Software. Turn data into answers reliable data processing made easy ONE TOUCH PRODUCTIVITY

Changing the Game in LC-MS/MS. New Tools for Unprecedented Performance in Residue Analysis. Dr. Thomas Glauner

QUANLYNX APPLICATION MANAGER

Comprehensive Service Options for Your Lab

Agilent 6500 Series Q-TOF LC/MS System

Implement High Quality, Routine GC-MS/MS Multi-Residue Pesticides Analysis with Ease Paul Silcock & Jason Cole

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

PESTICIDE SCREENING APPLICATION SOLUTION

LC/MS/MS Solutions for Biomarker Discovery QSTAR. Elite Hybrid LC/MS/MS System. More performance, more reliability, more answers

Application Note. Abstract. Authors. Introduction. Environmental

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

rapiflex Innovation with Integrity Designed for Molecules that Matter. MALDI TOF/TOF

REGULATORY PESTICIDE ANALYSIS JUST GOT EASIER. QSight Pesticide Analyzer

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

Pharmacokinetic Analysis of the mab Adalimumab by ELISA and Hybrid LBA/LC/MS: A Comparison Study

Quantitation of cyanotoxins in drinking water according to EPA 544 guidelines

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

SPECIFICATIONS FOR TENDER # SUPPLY OF BLOOD GAS ANALYZER FOR WESTERN HEALTH

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Transform Your Laboratory Operations. Agilent CrossLab services and support portfolio

Agilent CrossLab Services and Support Portfolio TRANSFORM YOUR LABORATORY OPERATIONS

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

The clearly better choice

Simultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Notice is hereby given of the following changes to the above-referenced SOLICITAITON:

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

[ EMPOWER 3 SOFTWARE ] MORE CAPABILITIES FOR YOUR LAB, MORE VALUE FOR YOUR ENTERPRISE

[ MARKET SOLUTION ] Chromatography Data System Solutions for the Agrochemical Industry

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

UNIFI: an innovative enabling platform Ken Eglinton Nordic User Training, September 2013

AGILENT CUSTOMER EDUCATION CATALOG

Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules

Development of a Fast and Cost-Effective Multi-Residue Method to Determine Pesticides in Tobacco by LC/MS/MS

A Sub-picogram Quantification Method for Desmopressin in Plasma using the SCIEX Triple Quad 6500 System

Detecting Challenging Post Translational Modifications (PTMs) using CESI-MS

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

On-Line. User s Guide SPE CARTRIDGES. for Rapid Cleanup and Extraction of Analytes

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Strategies for Risk Based Validation of Laboratory Systems

With the globalization of trade, food production

DETERMINATION OF PROTEIN BINDING BY UPLC/MS/MS

Converting a Liquid-Liquid Extraction Method for Vitamin D to a 96-Well Plate Supported Liquid Extraction Format

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Agilent OpenLAB CDS. Manage your chromatography better than ever before

ENERGIZE YOUR PROCESS

Accucore. Ultimate Core Performance LC Column Technology to Maximize Your Investment. Dave Jarzinski. October 2011

Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series

ANALYTICAL GAS GENERATORS

Author to add specific customer activities or additional help, information, or guidance for the customer to follow prior to installation.

Enabling Systems Biology Driven Proteome Wide Quantitation of Mycobacterium Tuberculosis

ENHANCED MS WITH THE TURN OF A KEY

HPLC/FLASH Purification ADVANCE THE PACE OF YOUR DISCOVERY TO ACHIEVE THE RESULTS OF TOMORROW

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

Agilent University Course Catalog Edition Thailand

HDX-MS at Waters Waters Corporation 1

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Qualification of High-Performance Liquid Chromatography Systems

BÜCHI Labortechnik AG

The Office of Financial Regulation Statement of Agency Organization and Operation

SCION GC Series. The Gas Chromatographers Choice for Separations

Measurement of Hepcidin-25 in Serum Using the Agilent 6490 Triple Quadrupole LC/MS with ifunnel Technology

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Metabolomics: Sifting Through Complex Samples

IBM Business Process Manager on Cloud

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins

Investigation of Solid Phase Microextraction as an Alternative to Dried Blood Spot

Analysis of Glyphosate and AMPA in Environmental Water Samples by Ion Chromatography and On-Line Mass Spectrometry with Minimal Sample Preparation

Utilizing novel technology for the analysis of therapeutic antibodies and host cell protein contamination

Transcription:

NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778) This Notice of Intended Decision to Enter into a Single Source Contract is posted in accordance with section 287.057(3), Florida Statutes. AGENCY: Department of Environmental Protection TITLE: Single Source with AB Sciex LLC Short description of the commodity or service desired: Liquid Chromatograph/Tandem Mass Spectrometer (LC/MS-MS) Instrument. CONTACT Name: Gloriann McInnis Address: 3800 Commonwealth Blvd, MS93, Tallahassee, FL 32399 Telephone: (850) 245-2354 Email: gloriann.mcinnis@dep.state.fl.us Internal tracking number, if any: DEP 16/17 SSA020 DMS Single Source number, if applicable: N/A Date posted: June 6 th, 2017 Time Posted: 8:00 AM (ET) Commodity or Contractual Service (commodity or United Nation Standard Products and Services Code (UNSPSC), manufacturer, model, and description, as appropriate): 41115700 Chromatographic measuring instruments and accessories Requestor (division, bureau, office, individual, as appropriate): Kerry Tate, Division of Environmental Assessment & Restoration, Bureau of Laboratories, Chemistry section Performance and/or Design Requirements (intended use, function or application, compatibility, requirements; reference to policy, rule, statute or other act of the Legislature, as appropriate): The Florida Department of Environmental Protection, Chemistry Program, seeks to upgrade its analytical High Performance Liquid Chromatography (HPLC) capabilities with the acquisition of an efficient liquid chromatograph/triple quadrupole mass spectrometer (LC/MSMS) for organic analysis. The LC/MSMS instrument being replaced (AB SCIEX 3200, S/N: AA0480507) is no longer effective for the tasks being performed due to limited instrument sensitivity, and therefore no longer meets the needs of the laboratory. To adequately meet the needs of the chemistry laboratory it is imperative to obtain replacement instrumentation having greater sensitivity. The LC/MSMS specifications, computer software, and data file format for the new instrument must be compatible with our existing equipment to maintain consistency, exchangeability, and integration. To adequately meet the needs of the chemistry laboratory, the LC/MSMS system must meet or exceed the following requirements and specifications. The instrument system must consist of a triple quadrupole mass spectrometer, LC/MSMS instrument control software, and data reporting software. Intended Single Source: AB Sciex LLC Price: $279,157.30 PUR 7778 (Eff. 03/2016) Page 1 of 5 60A-1.045, F.A.C.

Justification for Single Source Purchase (what is necessary and unique about the commodity, contractual service, or source; steps taken to confirm unavailability of competition, as appropriate): The LC/MSMS specifications, computer software, and data file format for the new instrument must be compatible with our existing equipment to maintain consistency, exchangeability, and integration. To adequately meet the needs of the chemistry laboratory, the LC/MSMS system must meet or exceed the following requirements and specifications. The instrument system must consist of a triple quadrupole mass spectrometer, LC/MSMS instrument control software, and data reporting software. A market review of LC/MSMS manufactures is also provided. 1. Mass Spectrometer Specifications: 1.1. The mass spectrometer must be a bench top triple quadrupole instrument capable of performing ultra-high sensitivity full-scan MS and MS/MS analysis. The sensitivity of the instrument in positive Multiple Reaction Monitoring (MRM) mode for 1 pg of Reserpine on column must give a S/N >510,000. In negative MRM mode the instrument must give a S/N> 180,000 for 1 pg of Chloramphenicol on column. The instrument design specifications are required to achieve the lab s specified qualitative, quantitative, and detection limit objectives for a broad range of analytes in complex environmental samples. 1.2. The mass spectrometer must have a mass range of at least 5 to 2000 m/z with a mass stability of 0.10 Da in a 24-hour period. The mass range and stability requirements are needed to insure suitability for a wide range of potential environmental compounds of interest. 1.3. The mass spectrometer must be equipped with a curved acceleration collision cell enabling effective collection and transmission of ions, while minimizing space requirements and neutral species rejection. This requirement insures optimum performance in complex sample matrices and minimizes the overall size of the instrument. 1.4. The instrument system must have as an option a source feature which allows for differential ion mobility spectrometry capabilities. This feature adds additional dimensions of selectivity necessary in some difficult analytical separations and helps future-proof the instrument for emerging analytical applications. 1.5. The mass spectrometer must be capable of performing multiple reaction monitoring (MRM), neutral loss, and precursor ion scanning using scheduled MRM. The instrument must be capable of a minimum MRM dwell time of 1 msec, inter-mrm pause time < 3 msec, 12,000 Da/s scan speeds, and polarity switching of 5 msec. The impact of operating the instrument under these fast collection conditions must be less the 10% if the speed conditions are slowed. These scanning speed specifications are requirements for the laboratory s LC/MS/MS methods, saving instrument set-up and operational time. 1.6. The instrument must come equipped with a heated ion spray source capable of flow rates from 5.0 to 3000 µl/min without flow splitting and heating to 750 C. This specification is designed to match the desired flow and heating requirements of the LC and MS/MS instrument sub-components and methodology. PUR 7778 (Eff. 03/2016) Page 2 of 5 60A-1.045, F.A.C.

1.7. The mass spectrometer must be compatible and ready to integrate (including all necessary hardware cables/connections and software) with the laboratory s existing Shimadzu Nexera UPLC instrument to which this mass spectrometer instrument will be connected. The main mass spectrometer software must be able to control the existing UPLC equipment. The instrument must come with everything ready to connect to our existing UPLC instrument. This specification is needed to provide trouble-free instrument connectivity, communication, and optimal chromatographic separation for our various analytical tests. 1.8. The mass spectrometer system and supporting software must have the ability to accommodate multiplexing with a second HPLC instrument. This multiplexing capability allows the mass spectrometer to collect data from more than a single HPLC instrument, thus maximizing laboratory production. 1.9. The mass spectrometer s ion source interface must have an orifice rather than a heated capillary design. The direct orifice interface maximizes instrument performance and minimizes maintenance requirements. 2. Data System Specifications: 2.1. A complete, authorized software package for control of the liquid chromatograph and mass spectrometer is required. The software must include the capability to control auto-tuning, data acquisition, data analysis, method automation, macro-programming, data processing and reporting, automatic peak deconvolution capabilities, and system management utilities. Software is required to operate and report the LC/MS/MS data. 2.2. The LC/MS/MS software must be capable of qualitatively and quantitatively determining up to 300 compounds per injection in MRM mode with a minimum of 2 transitions per compound for identification and a minimum of 10 scans per compound for quantitation. To achieve this capability, the instrument software must perform measurements with dwell times as short as 1 millisecond. These features are needed to properly analyze and report a large number of analytes in complex environmental samples. 2.3. The data system must have the ability to process previously acquired data from our existing AB SCIEX LC/MSMS instruments which utilize Analyst TM and Multiquant TM Software. This requirement will minimize staff training and avoid the expense associated with purchasing multiple GC/MS libraries, streamline data processing, and storage/recovery of archived data. 2.4. The data system must be capable of scheduled MRM whereby the instrument scans for ions of interest only when these ions are expected to enter the instrument. This time saving and instrument optimization feature is needed since it can result in increased instrument sensitivity and performance. 3. Service, Installation, and Training: 3.1. The Service Provider must include delivery and installation of all equipment, including checkout and verification of performance. The Service Provider must offer on-site services including all labor, parts, and materials required to maintain the hardware in good operating PUR 7778 (Eff. 03/2016) Page 3 of 5 60A-1.045, F.A.C.

condition. This provides immediate verification that the instrument is working properly before the laboratory officially accepts the purchased equipment. 3.2. The Service Provider must be the original equipment manufacturer (OEM) or a certified manufacturer distributor. The equipment must not be modified against the original manufacturer s recommendation. This insures that the instrument does not void the OEM warranty and that service and parts will be available during the life of the instrument. 3.3. The LC/MS/MS and Chromatography Data Acquisition System must include a maintenance warranty and technical support of at least one (1) year including all parts, software upgrades, labor and travel and have available optional enhanced/extended warranty packages. Warranty service is needed to mitigate potential instrument failure and reduce instrument down-time. 3.4. The vendor must provide ongoing service agreements using OEM-trained service engineers for the entire LC/MSMS system, including the existing Shimadzu Nexera UPLC, mass spectrometer, computer, and data collection system. 3.5. The LC/MS/MS vendor must guarantee in writing a maximum response time of three hours for service calls via telephone whenever the system is inoperable, and a maximum response time of two work days for on-site service whenever telephone consultation cannot resolve the problem. Both aforementioned response times are defined as the length of time from first contact by FDEP regarding an inoperable system to either the receipt of a telephone response from a service engineer or the arrival of a service engineer. This requirement will help minimize downtime and disruption to the laboratory services. 3.5. The vendor must guarantee in writing that technical support will be provided for the lifetime of the System and that service contracts will be available to the Department for the instrument at least seven (7) years after delivery. This helps insure the laboratory can receive quality service over the life of the instrument. 3.6. Service must include an assigned Account Customer Engineer and an assigned backup Customer Engineer to insure uninterrupted service to our laboratory. 3.7. The Service Provider must include instrument familiarization/ training at the time of instrument installation or at a mutually agreed time following instrument installation. Companies and Instrument Systems Considered in Our Market Review: The following companies and instrument systems were considered in this review and were evaluated by the previously listed specifications. There may be additional specifications, besides those listed, that are not fully met by the excluded vendors. Company: AB SCIEX LLC Comments: Selected Instrument. Instrument: 6500+ Triple Quadrupole Mass Spectrometer Company: Agilent Technologies Instrument: 6400 Series LC-MS/MS Triple Quad Mass Spectrometer Comments: Does not meet specification 1.4, 1.7, 1.8, 1.9, and 2.3. Company: Bruker Instrument: EVOQ Triple Quad Series Mass Spectrometer Comments: Does not meet specification 1.1, 1.4, 1.7, 1.8, 1.9, and 2.3. Company: Thermo Scientific Instrument: TSQ Series Triple Quadrupole Mass Spectrometer Comments: Does not meet specification 1.2, 1.4, 1.5, 1.7, 1.9, and 2.3. Company: Shimadzu Instrument: LCMS-8000 Triple Quad Series Mass Spectrometer Comments: Does not meet specification 1.3, 1.4, 1.5, 1.8, 1.9, and 2.3. Company: Waters Instrument: Xevo Series Triple Quadrupole Mass Spectrometer Comments: Does not meet specifications 1.4, 1.5, 1.7, 1.8, and 2.3 PUR 7778 (Eff. 03/2016) Page 4 of 5 60A-1.045, F.A.C.

After a careful market review, we have concluded that AB SCIEX LLC is the only vendor that can provide the replacement LC/MSMS instrumentation compatible with our existing laboratory operations and analytical needs. Approved By (names & titles, as appropriate, e.g., requestor, requestor management, information systems, budget, purchasing) Kerry Tate, Environmental Manager Colin Wright, Program Administrator David Whiting, Deputy Director Sara E Armour, Environmental Scientist III Fran Spivey, Deputy Purchasing Director Gloriann McInnis, Purchasing Analyst Failure to file a protest within the time prescribed in section 120.57(3), Florida Statutes, or failure to file a bond or other security within the time allowed for filing a bond, shall constitute a waiver of proceedings under Chapter 120, Florida Statutes. PUR 7778 (Eff. 03/2016) Page 5 of 5 60A-1.045, F.A.C.