Distribution Information Exchange Code

Similar documents
Distribution Code Definitions

THE GRID CODE FOR THE NIGERIA ELECTRICITY TRANSMISSION SYSTEM

Distribution System Design General Requirements

Facility Interconnection Requirements

WIND TURBINES IN WEAK GRIDS CONSTRAINTS AND SOLUTIONS. J O G Tande and K Uhlen. SINTEF Energy Research, Norway SUMMARY

AGREEMENT FOR CONNECTION TO [EASTERN /LONDON / SOUTH EASTERN] POWER NETWORKS PLC S DISTRIBUTION SYSTEM

IMP/001/914 Code of Practice for the Economic Development of the 132kV System

safe reliable affordable GENERATOR COMPLIANCE MONITORING PROGRAM REQUIREMENTS 1 21 September 2015 TITLE: PREPARED BY: SYSTEM ANALYSIS & SOLUTIONS


Standard TPL Transmission System Planning Performance Requirements

Regulatory Audit Of Compliance Reporting For The Ord Hydro Transmission Network

Technical Requirements for Distributed Generation Connection

UNMIK REGULATION NO. 2004/22 ON THE PROMULGATION OF A LAW ADOPTED BY THE ASSEMBLY OF KOSOVO ON ELECTRICITY

NEW JERSEY BOARD OF PUBLIC UTILITIES N.J.A.C. 14:4-9 Net Metering and Interconnection Standards for Class I Renewable Energy Systems

Standard Development Timeline

POTOMAC ELECTRIC POWER COMPANY

Procedure UE PR Access to the United Energy Electricity Network. Document UE PR 0001

NATIONAL ELECTRICITY RULES ELECTRICITY CONNECTION FOR RETAIL CUSTOMERS CHAPTER 5A. Page 615

Electricity Supply Agreement

Detailed Requirements Document (DRD) Rail Engineering Advanced Technician Level 4 Electrification Knowledge & Skills Content

Public Utility District Number 1 of Snohomish County

Public Utility District Number 1 of Snohomish County. Facility Connection Requirements February 9, 2018

Attachment B. [Note: The following new definitions inserted after the definition of Regulations ]

THE DISTRIBUTION CODE THE GUIDE TO THE DISTRIBUTION CODE

Connection of generation plant to distribution networks. Guidance on completing the application form

ELECTRIC ARC FURNACE WITH STATIC VAR COMPENSATOR PLANNING AND OPERATIONAL EXPERIENCE

Technical considerations for integration of distributed renewables on the grid

CHOPTANK ELECTRIC COOPERATIVE, INC. P.S.C. Md. No. 3 Fifth Revised Page No. 59 COGENERATION AND SMALL POWER PRODUCTION RATE SCHEDULE X

South African Distribution Code

Customer charter for electricity networks.

CUSTOMER SERVICE POLICIES

Member Service Electric Wiring Guidelines

SMART GRID SCENARIO. Marina Egea,

The South African Grid Code. Preamble

MOD Data for Power System Modeling and Analysis

Route to Authorisation

COMPLIANCE MONITORING REPORT OF MAFUBE LOCAL MUNICIPALITY

Wolverine Power Supply Cooperative, Inc. Senior Transmission System Operator

UNOFFICIAL TRANSLATION SUPPLY OF REACTIVE POWER AND MAINTENANCE OF REACTIVE POWER RESERVES

1. an Employee's private interests interfere, or even appear to interfere, with the interests of the Company;

DISTRIBUTION NETWORK OPERATOR CONNECTION CHARGING METHODOLOGY

Engineering Recommendation G81 - Part 4: Design and Planning

STATEMENT OF CHARGES FOR CONNECTION TO NORTHERN IRELAND ELECTRICITY NETWORKS DISTRIBUTION SYSTEM. Effective from 1 st October 2017 Version 1.

DISTRIBUTION CODE OF SRI LANKA. Public Utilities Commission of Sri Lanka

ON THERMAL ENERGY. Based on Article 65 (1) of the Constitution of the Republic of Kosovo, LAW ON THERMAL ENERGY CHAPTER I GENERAL PROVISIONS

Net Metering inter connection agreement

Services for professional procurement. Be better informed, make better decisions. RISQS Audit Questions Network Rail On-Track Plant Operations

SCHEDULE 12 Transmission Enhancement Charges. Establishment of Transmission Enhancement Charges.

Information Document Service Proposals and Cost Estimating ID # R

Transmission Competitive Solicitation Questions Log Question / Answer Matrix Delaney to Colorado River 2014

Requirements for Transmission System Interconnections to Generation, Transmission and End-User Facilities Revised June 10, 2014

ENMAX POWER CORPORATION. Requirements for Distribution Wires Access

PUBLIC WIFI FROM EE SOLUTION TERMS

DOMESTIC ELECTRICAL INSTALLATION PERIODIC INSPECTION REPORT (FOR A SINGLE DWELLING) B ADDRESS AND DETAILS OF THE INSTALLATION Address: SPECIMEN

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

XXXX. Bremner Trio Small Hydro Project. Interconnection System Impact Study

(On Stamp Paper of Rs.100/-) Net Metering Inter Connection agreement

DISTRIBUTION LOSS ADJUSTMENT FACTORS ESB SUBMISSION THE COMMISSION FOR ELECTRICITY REGULATION

THIS COPY IS INTENDED FOR PREVIEW ONLY IT2015 ETP SPECIAL TERMS AND CONDITIONS FOR SERVICES DELIVERED VIA DATA NETWORK (CLOUD SERVICE)

Energex. Tariff Structure Statement. 1 July 2017 to 30 June Energex s Tariff Structure Statement

AURORA ENERGY LTD. Use-of-System Pricing Methodology

Slide 1. ABB August 23, 2016

Specification for the Installation of Low Voltage Internal Mains and Services

FAC Facility Interconnection Requirements

Standard PRC-002-NPCC-01 Disturbance Monitoring

Customer Connection Guide. Document number SOP Issue number 9 Status Approver

Incremental Black Start RFP Response Template & General Information

Tariffs January 1, 2017

Consultation on Connecting Further Generation in Northern Ireland. Call for Evidence

Underground commercial and industrial or rural subdivisions (vacant lots - no development)

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

Rule 21 Sheet 1 GENERATING FACILITY INTERCONNECTIONS

Irish Water Business Customer Codes of Practice

SOLUTION DESCRIPTION

Lesson Learned Loss of Wind Turbines due to Transient Voltage Disturbances on the Bulk Transmission System

Speedy Group Policy Part of: Group Policies & Procedures

How to Apply For Electricity Connection

Asset Risk Management Journey Plan

Engineering Recommendation G81 Part 1 Issue Framework for new low voltage housing development installations Part 1 Design and planning

Distributed Generation. Technical Requirements and Interconnection Agreements

Investigation of Impacts of Solar PV on Transmission System Voltage Stability Considering Load Characteristics and Protection

De-Energisation Code of Practice

PROPOSALFOR INCLUSION OF A TRANSCO INCLUDING ENTERGY WITHIN THE SPP RTO

Data Protection Strategy Version 1.0

LOAD SERVING ENTITIES PJM REGION

Manager, Sourcing Supply and Contracts, Grid Projects Approved By:

12th HSBC SRI Conference February 2017

Information Governance Policy

GHANA POWER SYSTEM STANDARDISATION AND ITS CHALLENGES PRESENTATION BY ING JOSEPH WIAFE MEMBER GNEC

SCHEDULE SS STANDBY SERVICE

Identity Provider Policy. Identity and Authentication Services (IA Services)

STANDARD SUPPORT SERVICE FOR LARGE BUSINESS CUSTOMERS SOLUTION DESCRIPTION

International ejournals

8 th Annual Electric Power Industry Conference

Quality Assurance Manual

9 ENVIRONMENTAL MANAGEMENT PLAN 9.1 OVERVIEW AND SCOPE Introduction

ELECTRICITY SUPPLY - POWER SYSTEM MAINTENANCE Carry out routine inspection and servicing on high voltage minimum oil circuit breakers

3. RELATIONSHIP BETWEEN ISO AND PARTICIPATING TOs. Each Participating TO shall enter into a Transmission Control Agreement with the

ASSET MANAGEMENT PLAN NETWORK TASMAN LIMITED

WIND ENERGY INTEGRATION IMPACT ON POWER QUALITY IN ESTONIA

Transcription:

Distribution Information Exchange Code Version 5.1 Approved September 2007 Comments to this document can be forwarded to: The RSA Grid Code Secretariat Attention: Mr. Bernard Magoro Eskom, Transmission System Operator P.O Box 103, Germiston 1400 Tell: +27 (0)11 871 2774 Fax: +27 (0)11 871 3238 Mobile: +27 (0)83 292 2876 Email: bernard.magoro@eskom.co.za

Table of Contents 1. OBJECTIVES... 3 2. SCOPE OF APPLICATION... 3 3. INFORMATION EXCHANGE INTERFACE... 3 4. PROVISION AND EXCHANGE OF INFORMATION DURING THE PLANNING AND CONNECTION PROCESS... 4 5. OPERATIONAL INFORMATION... 5 5.1 COMMISSIONING AND NOTIFICATION... 5 5.2 SHARING OF ASSETS AND RESOURCES... 5 5.3 ADDITIONAL INFORMATION REQUIREMENTS... 5 5.4 COMMUNICATION AND LIAISON... 6 5.5 DATA STORAGE AND ARCHIVING... 6 6. CONFIDENTIALITY OF INFORMATION... 7 APPENDIX 1: INFORMATION CONFIDENTIALITY... 8 APPENDIX 2: CUSTOMER DATA PLANNING AND CONNECTION PROCESS... 10 APPENDIX 3: EMBEDDED GENERATOR DATA PLANNING AND CONNECTION PROCESS... 11 Page 2 of 11

1. Objectives (1) To define the reciprocal obligations of participants with regard to the provision and exchange of planning, operational and maintenance information for the implementation of the Distribution Code. (2) Information exchanged between participants governed by this code shall not be confidential, unless otherwise stated. 2. Scope of Application (1) The participants to whom the Distribution Information Exchange Code shall apply are: (a) Distributors (b) Retailers / Traders (c) Embedded Generators (d) End-use customers (e) Resellers (2) Information requirements specified in the other codes within the Distribution Code are supplementary to this code. In the event of inconsistencies between other codes and the Information Exchange Code with respect to information exchange, the requirements of the Information Exchange Code shall take preference. 3. Information Exchange Interface (1) The parties shall identify the following for each type of information exchange: (a) The name and contact details of the person(s) designated by the information owner to be responsible for provision of the information (b) The names, contact details of, and the parties represented by persons requesting the information (c) The purpose for which the information is required. (d) The parties shall agree on appropriate procedures for the transfer of information. (2) Participants (with installed capacity of more than 100kVA) shall exchange information, prior to commissioning, of new or altered equipment connected at the point of connection or changes to the operational regimes that could have an adverse effect on the DS to enable proper modifications to any affected participants networks and related systems. Page 3 of 11

4. Provision and exchange of Information during the planning and connection process (1) Each Distributor shall have a supply application form, which shall request, at minimum, the information stipulated in this section. (2) Customers requesting supply at low voltage shall provide the Distributor with the information relating to: (a) New or change in connected loads (b) Type of load to be connected to the Distribution System (c) Requested connection date (d) Proposed network connection point address. (3) Customers requesting supply at HV or MV shall, in addition to 4. (2) above, provide the Distributor with the following information: (a) Requested supply voltage (b) Expected and / or projected maximum demand (in kva ) (c) Expected load power factor (d) Switched customer capacitor banks and reactors, which could affect the Distribution System (e) Whether the load is capable of producing Harmonics as specified by equipment manufacturers (f) The nature and type of process the supply is requested for (g) Minimum required fault levels (h) Start-up requirements (i) Whether the customer has any standby generator. (4) The Distributor may request Customers to provide information on the Customer s proposed installation and equipment at the Point of Connection. (5) Participants shall exchange information relating to the protection of Distribution System and customer equipment protection coordination at the point of connection. (6) Upon any reasonable request, the Distributor shall provide customers or potential customers with any relevant information that they require to properly plan and design their own networks/installations. This may include but not limited to: (a) Nominal voltage at which connection will be made (b) Method of connection, extension and/or reinforcement details (c) The maximum and minimum fault levels (d) Method of earthing (e) Maximum installed Capacity at the point of connection (f) Specification of any accommodation of equipment requirement (g) Individual customer limits relating to: Page 4 of 11

i. Harmonic Distortion ii. Voltage Flicker iii. Voltage Unbalance (h) Expected lead time of providing connection (following formal acceptance of terms for supply) (i) An indication of network single contingency capability (j) An indication of current network performance and power quality (k) Cost of connection (l) Range of current approved tariff structures (7) Customers may be required to submit information as detailed in Appendix 2. 5. Operational Information 5.1 Commissioning and notification (1) Customers shall confirm that all information given in the application for supply and additional information subsequently requested by the Distributor is correct before the commissioning. (2) The commissioning dates shall be negotiated between the parties. Participants will agree on the type of operational data to be submitted prior to commissioning, which shall include test and commissioning report. (3) The asset owner (Distributor or Customer) shall ensure that all equipment records, that affect the integrity of the Distribution System or relevant to the interconnection, are maintained for reference for the duration of the operational life of the plant. On request from the Distributor, information shall be made available within a reasonable time. (4) The Distributor shall indicate to the customer what information is relevant in terms of this section. 5.2 Sharing of Assets and Resources (1) Distributors sharing assets and resources shall enter into agreements for the provision and sharing of their assets, resources, services and information. 5.3 Additional Information Requirements (1) Should one participant, acting reasonably, determine that additional measurements and/or indications are needed in relation to another participant s plant and equipment; the requesting participant shall consult with the affected participant(s) to agree on the manner in which the need may be met. The costs related to the modifications for the additional measurements and/or indications shall be for the account of the causal participant. Page 5 of 11

5.4 Communication and Liaison (1) Participants shall establish a communication channel for exchange of information required for distribution operations, which may include the installation of Distributor s SCADA equipment at the customer s or Distributor s installation to facilitate the flow of information and data to and from the Distributor and / or Transmission control facilities. (2) Each participant shall designate a person with delegated authority to perform the duties of information owner in respect of the granting of access to information covered in this code to third parties. A party may, at its sole discretion, designate more than one person to perform these duties. (3) The Distributor shall take reasonable steps to exchange information with the Distributor s affected customers for DS and TS outages. (4) Customers shall exchange information with the Distributors within an agreed lead time on all operations on their installations which may have an adverse effect on the Distribution System including any planned activities such as plant shutdown or scheduled maintenance. (5) The communication facilities standards shall be set and documented by the Distributor. Any changes to communication facilities standards impacting on participant equipment shall be brought to the attention of the participant well in advance of the proposed upgrade. (6) Any back up or emergency communication channels established by the Distributor and deemed necessary for the safe operation of the Distribution System shall be agreed upon by the Distributor and the participant affected. 5.5 Data Storage and Archiving (1) The obligation for data storage and archiving shall lie with the information owner. (2) The systems that store the data and/or information to be used by the participants shall be of their own choice and for their own cost. (3) All data storage systems must be able to be audited by the NERSA. The systems must provide for clear and accessible audit trails on all relevant operational transactions. All requests that require an audit on a system shall be undertaken with reasonable notice to the parties. (4) The information owner shall keep all information, except voice recorded information, in its original format for a period of at least five (5) years (unless otherwise specified differently in other parts of this code) commencing from the date the information was created. (5) Participants shall ensure reasonable security against unauthorised access, use and loss of information for the systems that contain the information. Page 6 of 11

(6) Distributors shall use a voice recorder for historical recording of all operational voice communication with participants. These records shall be available for at least three (3) months except where there is an incident involved, in which case the requirements of any applicable legislation shall apply. The Distributor shall make the voice records of an identified incident in dispute available within a reasonable time period after such a request from a participant and/or the NERSA. (7) An audit trail of all changes made to archived data should be maintained. This audit trail shall identify every change made, and the time and date of the change. The audit trail shall include both before and after values of all content and structure changes. 6. Confidentiality of information (1) Information exchanged between participants governed by this code shall not be confidential, unless otherwise stated. (2) Participants receiving information shall use the information only for the purpose for which it was supplied. (3) The information owner may request the receiver of information to enter into a confidentiality agreement before information, established to be confidential, is provided. A pro forma agreement is included in Appendix 1. (4) Confidential information shall not be transferred to a third party without the written consent of the information owner. Parties shall observe the proprietary rights of third parties for the purposes of this code. Access to confidential information within the organisations of parties shall be provided as reasonably required. (5) The participants shall take all reasonable measures to control unauthorised access to confidential information and to ensure secure information exchange. Parties shall report any leak of information that is governed by a confidentiality agreement as soon as practicable after they become aware of the leak, and shall provide the information owner with all reasonable assistance to ensure its recovery or destruction (as deemed appropriate by the information owner). Page 7 of 11

APPENDIX 1: Information confidentiality Sample confidentiality agreement for information transfer to third parties CONFIDENTIALITY AGREEMENT BETWEEN. (HEREINAFTER REFERRED TO AS THE INFORMATION OWNER) AND. (HEREINAFTER REFERRED TO AS THE RECIPIENT) IN RESPECT OF INFORMATION SUPPLIED TO PERFORM THE FOLLOWING WORK: (HEREINAFTER REFERRED TO AS THE WORK) ON BEHALF OF.. (HEREINAFTER REFERRED TO AS THE CLIENT). 1. The Recipient agrees to treat all information (hereinafter referred to as the Information) received from the Information Owner, whether in hard copy or electronic format, as strictly confidential. 2. The Recipient agrees to disclose the Information only to persons who are in his permanent employ, and who require access to the Information to perform their duties in respect of the Work on behalf of the Client. 3. Persons other than those described in Clause 2 above, including but not restricted to temporary employees, subcontractors, and sub-consultants, shall enter into separate Confidentiality Agreements with the Information Owner prior to receiving the Information. 4. The Recipient undertakes to use the Information only to perform the Work on behalf of the Client, and for no other purpose whatsoever. 5. On completion of the Work, the Recipient shall at his expense return to the Information Owner all hard copy material and electronic media containing the Information supplied to him by the Information Owner. The Recipient shall furthermore ensure that all duplicate copies of the Information in his or his employees possession (electronic as well as hard copy format) are destroyed. 6. The Recipient shall take all reasonable measures to protect the security and integrity of the Information. 7. If requested to do so by the Information Owner, the Recipient shall forthwith at his expense return to the Information Owner all hard copy material and computer disks containing the Information supplied to him by the Information Owner. The Recipient Page 8 of 11

shall furthermore ensure that all duplicate copies of the Information in his or his employees possession (electronic as well as hard copy format) are destroyed. 8. The Recipient shall report any leak of the Information, howsoever caused, to the Information Owner as soon as practicable after he/she becomes aware of the leak, and shall provide the Information Owner with all reasonable assistance to ensure its recovery or destruction (as deemed appropriate by the Information Owner). Signed at on this the day of. by (full name).in his/her capacity as. on behalf of, the Information Owner Signed at on this the day of. by (full name).in his/her capacity as. on behalf of, the Recipient Page 9 of 11

APPENDIX 2: Customer data Planning and Connection Process LV Low Voltage, MV Medium Voltage, HV High Voltage Information and data to be provided by Customers Demand and Network Data Connected load Maximum demand Type of load Maximum load on each phase Connection date Fluctuating loads Disturbing loads Electrical Diagrams and Connection Point Drawings Generation and transformation equipment Electrical circuits including overhead lines and underground cables Substation bus arrangement Grounding arrangement Phasing arrangement Switching facilities Circuit parameters from the Customer s substation to the Connection Point in the Distribution System Rated and operating voltage Positive sequence impedance Positive sequence susceptance Zero sequence impedance Zero sequence susceptance Power transformer data Rated MVA Rated voltage Winding arrangement Positive sequence impedance @max, min and nominal tap Zero sequence reactance Tap changer information Basic insulation level Switchgear information including circuit breakers, load break switches and disconnect switches at the connection point Reactive power compensation plant Rated capacity in MVAR Rated voltage Type of reactive power compensation plant Operation and controls Demand transfer capabilities in case the portion of the customer load is or can be supplied from another connection point LV Customers MV/HV Customers Page 10 of 11

APPENDIX 3: Embedded generator data Planning and Connection Process LV Low Voltage, MV Medium Voltage, HV High Voltage Information and data to be provided by Customers Demand and Network Data Connected load Maximum demand Type of load Maximum load on each phase Connection date Fluctuating Loads Disturbing loads Electrical Diagrams and Connection Point Drawings Generation and transformation equipment Electrical circuits including overhead lines and underground cables Substation bus arrangement Grounding arrangement Phasing arrangement Switching facilities Circuit parameters from the Customer s substation to the Connection Point in the Distribution System Rated and operating voltage Positive sequence impedance Positive sequence susceptance Zero sequence impedance Zero sequence susceptance Power transformer data Rated MVA Rated voltage Winding arrangement Positive sequence impedance @max, min and nominal tap Zero sequence reactance Tap changer information Basic insulation level Switchgear information including circuit breakers, load break switches and disconnect switches at the connection point LV Customers MV/HV Customers Reactive power compensation plant Rated capacity in MVAR Rated voltage Type of reactive power compensation plant Operation and controls Demand transfer capabilities in case the portion of the customer load is supplied from an connection point Page 11 of 11