Agilent 720/725 ICP-OES RELIABLE. PRODUCTIVE. ROBUST.

Similar documents
Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

ICP Expert software. Technical Overview. Introduction

Runs On Air. AGILENT 4100 MICROWAVE PLASMA ATOMIC EMISSION SPECTROMETER

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION SPECTROMETERS

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Composition Analysis of Animal Feed by HR ICP-OES

Agilent Resources for Workflow Compliance MEASURING ELEMENTAL IMPURITIES IN PHARMACEUTICAL MATERIALS

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

PinAAcle 900 Series. Atomic Absorption Spectrometers

Avio 200 ICP-OES Flat Plate

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Analysis of Trace Metals in Surface and Bottled Water with the Optima 7300 DV ICP-OES

Thermo Scientific icap RQ ICP-MS. Simplicity, productivity and robustness for routine labs

The image part with relationship ID rid4 was not found in the file. Welcome

PinAAcle 500. Flame Atomic Absorption Spectrometer

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

HIGHER IMPACT LC/MS DIAGNOSTICS AGILENT IN VITRO DIAGNOSTIC MEDICAL DEVICES FOR CLINICAL LABORATORIES

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

TurboMass GC/MS Software

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

SPECTRO ARCOS. ICP-OES analyzers. When results matter

SPECTRO ARCOS ICP-OES ANALYZERS. When results matter

Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

Don t Settle for just any Mercury Analyzer...Go with the Experts in Mercury Analysis...Go with Teledyne Leeman Labs

Agilent solutions for contract research and manufacturing organizations

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

Agilent 1260 Infinity II LC ASPIRE TO NEW LEVELS OF EFFICIENCY EVERY DAY IN EVERY WAY

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

Thermo Scientific GENESYS 10S Bio spectrophotometer

Sum Parameter Analysis AOX/TOX. AOX Analyzer multi X 2500

High-performance X-ray analysis software

BÜCHI Labortechnik AG

Thermo Scientific icap 7000 Series ICP-OES Accessories Guide

DRPK-005

Technical specifications

High-Purity Acids & Reagents

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

HiSeqTM 2000 Sequencing System

Spectroscopy Solutions for Pharmaceuticals:

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

IR READY TO GO. Spectrum Two FT-IR Spectroscopy

Multitype ICP Emission Spectrometer ICPE-9000 C113-E012J

Sensortherm. Digital Pyrometer. Temperature Measurement and Control. com

Analysis of elemental impurities in drug products using the Thermo Scientific icap 7600 ICP-OES Duo

Agilent OpenLAB CDS. Manage your chromatography better than ever before

TANGO. ANALYSIS TO GO. Innovation with Integrity. The next generation FT-NIR spectrometer. FT-NIR

Thermo Scientific icap Q ICP-MS

Get your hands on. And get results in a flash.

Get your hands on. And get results in a flash.

Evaluation of Energy-Dispersive X-Ray Fluorescence for Mobile Analysis of Hazardous Metals in Transuranic Waste

SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009

Agilent 8355 Sulfur Chemiluminescence Detector REIMAGINED. REDESIGNED.

PMI-MASTER Compact. Cost-effective, rugged and precise mobile metal analyser. Routine analysis at entry level. Easy and fast testing

AUTOMATED WATER ANALYSIS

Cleaning Validation PRODUCT OVERVIEW

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Method Development and Validation for Online UV-Dissolution Methods Using Fiber-Optic Technology

Elemental Impurities Regulations View from a CRO

New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)

SPECTRAL INTERFERENCE IN X-RAY FLUORESCENCE ANALYSIS OF COMMON MATERIALS

RightWave EDF Family. The Right Fiber Diet for Optical Amplifier Design. OFS Your Optical Fiber Solutions Partner

Agilent 6430 Triple Quadrupole LC/MS System

Thermo Scientific Peptide Mapping Workflows. Upgrade Your Maps. Fast, confident and more reliable peptide mapping.

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

Optical Emission Spectrometers

Agilent Sample Preparation Portfolio ACCURATE, REPRODUCIBLE RESULTS RIGHT FROM THE START

Simple, fast and reliable analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

TGA 8000 Thermogravimetric Analyzer BETTER CHARACTERIZATIONS START WITH BETTER CONTROL

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

Selenium in Natural Waters by Graphite Furnace Atomic Absorption using EPA Method 200.9

SCION GC Series. The Gas Chromatographers Choice for Separations

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

SCION GC Series. The Gas Chromatographers Choice for Separations

Atomic Absorption Spectrometry. Quality is the Difference novaa

NovoCyte Flow Cytometer

Trace Moisture Contamination in Ultra-High Purity Phosphine: Techniques for Measurement and Control

Qualification of High-Performance Liquid Chromatography Systems

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

GRUNDFOS CRE range. Customised pump solutions Optimised for temperature control

Transcription:

Agilent 720/725 ICP-OES RELIABLE. PRODUCTIVE. ROBUST.

720/725 ICP-OES The world s best ICP-OES The Agilent 720/725 ICP-OES offer the fi nest performance, speed and reliability. At the heart of these instruments is the next generation VistaChip II, a custom designed, hermetically sealed CCD detector, giving you unrivaled productivity. With a range of performance enhancing options and a powerful software platform, the 720/725 will meet your most demanding needs now and in the future. The Agilent 720/725 ICP-OES systems are the world s most productive highperformance and only truly simultaneous ICP-OES. Reliable Continuous wavelength coverage provides the ability to select multiple wavelengths for a given element, thereby extending dynamic range and avoiding interferences, giving you maximum confi dence in your results. Productive One view, one step measurement of major, minor, and trace elements, plus the fastest warm-up, increases throughput and productivity. Robust Exceptionally robust plasma ensures reliable and reproducible results, even with the most complex matrices. Cost-effective With a sealed CCD detector that requires no purging, a compact optical system, and an effi cient RF system that sustains an analytical plasma at lower argon fl ows, the Agilent 720/725 lower gas usage and operating costs. Flexible Choice of optimized axial (720) or radial (725) confi gurations to suit your application needs. Intuitive Superior software features providing automation and ease-ofuse. The Agilent 720/725 ICP-OES feature a custom-designed proprietary CCD detector, delivering the world s most productive, high-performance ICP-OES platform. 2 For more information visit: www.agilent.com/chem/icpoes

720/725 ICP-OES Robust enough for complex samples With over 7,000 ICP-OES systems worldwide, Agilent s plasma generation system is fi eld-proven, exceptionally robust, and consistently provides stable and accurate results, even with the most challenging samples such as high salts, brines, dissolved solids and complex organics. The innovative Cooled Cone Interface (CCI) of the Agilent 720 ICP-OES removes the cooler tail of the plasma, increasing the linear dynamic range and reducing sample matrix-related interferences. The superior design of CCI eliminates the need for dual-view optics and expensive shear gases, saving you time and money. Designed for speed and accuracy The VistaChip II CCD detector sets the benchmark for speed and performance. The VistaChip II is optimized to exactly match the optical image produced by the echelle optics, requiring only 70,000 photosensitive pixels to provide complete wavelength coverage from 167 785 nm. Powerful and reliable software ICP Expert II software complements the power of the VistaChip II detector technology, featuring a range of Agilent exclusive software features: Fitted Background Correction (FBC) AutoMax auto-optimization Smart Rinse Fast Automated Curve-fi tting Technique (FACT) MultiCal Semi-quantitative analysis Time Resolved Spectroscopy (TRS) for speciation applications Remarkably better innovations Agilent 720 ICP-OES The Agilent 720 with axiallyviewed plasma provides exceptionally low detection limit performance. Featuring CCI, the Agilent 720 is perfectly suited to environmental, food, agriculture and industrial applications. Agilent 725 ICP-OES The Agilent 725 with radially-viewed plasma is the instrument of choice for routine analysis of diffi cult samples. The higher matrix tolerance of the vertically-oriented plasma has made it the industry standard for metals, mining and petrochemical applications. True simultaneous performance Featuring Adaptive Integration Technology, the VistaChip II provides true simultaneous measurement of all elements from parts-per-billion to percent levels in a single measurement, making it the most productive ICP-OES in the world. Remarkably better software With a familiar worksheet interface, automated method development, and wizards and videos to guide you, the Agilent ICP Expert II software saves you time. View analysis results instantly for easy data review and handling. For more information visit: www.agilent.com/chem/icpoes

MAXIMUM PERFORMANCE Agilent 720 ICP-OES productivity with extended dynamic range Agilent s 720 horizontally-oriented, axially-viewed plasma provides excellent sensitivity for trace-level determinations and the fl exibility to handle major levels. The robust plasma is able to analyze a wide variety of sample matrices while still delivering the best detection limits. Agilent s unique MultiCal feature extends the linear range of an analyte from parts-per-billion to percentage levels. Unlike dual-view systems, the Agilent 720 ICP-OES provides this linear dynamic range without having to analyze the sample twice. The 720 ICP-OES is ideal for the analysis of waters and wastes, soils and sediments, foods, beverages and agricultural samples, and is capable of measuring elements from trace to major levels simultaneously, with one plasma view. Agilent 725 ICP-OES robust performance for diffi cult samples If long-term analysis of the most diffi cult sample types is required, then Agilent s 725 offers the benefi ts of robust operation with minimal maintenance. The Agilent 725 radially-viewed plasma is vertically oriented, making it more tolerant to diffi cult matrices. The 725 provides long term stable performance even with high levels of dissolved salts or solids. Dualview plasma systems, which feature horizontal torches, cannot match the rugged, high solids performance of the 725. The robustness of the 725 makes it ideal for applications common to mining, chemicals manufacture, salt production, wear metals analysis, petrochemical production and precious metal refi ning. One-step analysis from one plasma view. Agilent s CCI for the 720 ICP-OES effi ciently removes the cool plasma tail (the red zone, top) away from the optical path. This minimizes self-absorption and recombination interferences to provide a wide linear dynamic range, reduced matrix interferences and low background for the best detection limits. Dual-view plasmas (bottom) either use a high-fl ow shear gas to ineffectively blow away the plasma tail from the optical path or do not remove the plasma tail at all, instead taking a second measurement, side-on to the plasma. This adds complexity, and increases analysis times, argon usage and running costs. 4

MAXIMUM PERFORMANCE Lowest operating costs The Agilent 720/725 ICP-OES offer a full suite of productivity enhancements to reduce operating costs and provide the throughput you need. With a sealed CCD detector that requires no purging, a compact optical system, and an effi cient RF system that sustains an analytical plasma at lower argon fl ows, the Agilent 720/725 lower gas usage and operating costs. Option of three- or fi ve-channel pump for online addition of internal standards and simultaneous measurement of hydride and non-hydride elements. Mass fl ow controlled nebulizer gas eases method development and provides fully automated operation. Argon Consumption/L 40000 35000 30000 25000 20000 15000 10000 5000 Daily Argon Consumption CID based Competitor Agilent 720 with Standard Conditions S w Agilent 720 with Low Flow Conditions or tions 0 0 100 200 300 400 500 600 Samples/Day Because of its fast sample throughput, low optical purge and sealed CCD detector, the Agilent 720 ICP-OES uses 20 40% less argon than rival systems in low fl ow mode. For challenging samples requiring higher argon plasma fl ow, the Agilent 720 will economically deliver accurate, interference-free results not possible with low fl ow conditions. Options for every application Choose from a range of sample introduction options, including plasma torches, nebulizers, spraychambers and tubing to suit your specifi c application requirements: Maximum sensitivity option for environmental, food and agricultural samples Petrochemical option for the analysis of organic and volatile organic solvents Inert sample introduction kits for samples containing hydrofl uoric acid (HF) Robust system for chemicals and other high dissolved solid samples High precision option for metals and precious metals Performance enhancing accessories The Agilent 720/725 ICP-OES feature a variety of accessories to further extend their capabilities. MSIS The Multi-mode Sample Introduction System (MSIS) provides simultaneous measurement of hydride and nonhydride elements including As, Se, and Hg to sub-ppb detection limits. The MSIS offers a choice of three modes that eliminate changeover and allow routine and hydride elements to be determined using the same setup. SVS 2 More than double the productivity of your 720/725 ICP-OES with the SVS 2 switching valve system. By reducing uptake, stabilization and rinse delays, the SVS 2 substantially reduces sampleto-sample cycle time. SPS 3 Automate and simplify analysis with the Agilent SPS 3 sample preparation system. With the fastest operation, extended sample capacity via rack changes, and a fl exible choice of racks, simply load, set, and go. OneNeb Exclusive to Agilent, the OneNeb nebulizer is designed to handle challenging samples. The inert polymer construction is resistant to organic solvents and strong acids, while the virtually unblockable design makes it ideal for samples containing high dissolved solids. Sheath gas torch Reduce salt build-up in the torch injector when analyzing high dissolved solid samples with the sheath gas torch, which further improves long term stability and reduces maintenance. 5 For more information visit: www.agilent.com/chem/icpoes

THE WORLD S MOST PRODUCTIVE ICP-OES True simultaneous measurement The Agilent 720/725 ICP-OES are the only true simultaneous ICP-OES with full wavelength coverage. The 720/725 ICP-OES use an echelle polychromator to separate and focus analyte emission lines generated in the plasma onto a detector for measurement. Unlike competitive systems, the optical design is optimized to provide complete wavelength coverage without the need for multiple detectors or multiple entrance slits. True simultaneous ICP-OES delivers superior performance, providing unmatched analysis speed, precision and accuracy. Setting the benchmark in performance The sealed CCD detector provides full wavelength coverage and fast readout for maximum fl exibility and productivity. Adaptive Integration Technology (AIT) prevents over-range signals by adjusting the measurement time simultaneously for each wavelength to achieve the optimum signal-to-noise ratio. AIT ensures all elements are always measured at the same time, irrespective of their concentration or emission line intensity. Image Mapping Technology (I-MAP) ensures complete coverage of all wavelengths by arranging 70,000 pixels in an uninterrupted array that exactly matches the two-dimensional echelle optical image. This ensures complete wavelength coverage from 167 785 nm and eliminates the need for separate sequential measurements. Temperature controlled optics and the hermetically sealed VistaChip II CCD detector provide excellent stability. An exceptionally fast warm up time allows you to start analyzing samples quickly. The higher diffraction orders of the echelle polychromator, combined with the best detector pixel resolution of the 720/725 ICP-OES, offer superior resolving power. gutter Unlike other CCD detectors, the VistaChip II features anti-blooming protection on every pixel. If during a reading an intense signal saturates a pixel (a), the excess electrons drain into the gutter rather than into nearby pixels or the other registers (b and c), allowing simultaneous measurement of trace analytes in the presence of concentrated elements. Intensity 40000 Cu 213.598 30000 20000 For a replicate time of 10 seconds, AIT simultaneously collects many short readings for high intensity lines, and fewer, longer readings for low intensity lines, providing the best signal-to-noise ratio and true simultaneous analysis. 10000 500 213.564 213.580 213.600 Wavelength (nm) 213.620 213.634 With an optical resolution of <8 pm and pixel resolution of 3 pm, the peaks of Cu 213.598 nm and P 213.618 nm are easily identifi able. 6

THE WORLD S MOST PRODUCTIVE ICP-OES The 720/725 provide true simultaneous measurement of all analytes, background and internal standards. Intelligent no-compromise system design means that all wavelengths are captured in one fast, effi cient reading, eliminating the need for multiple detectors, slits, or multiple plasma views. The proprietary VistaChip II CCD detector provides anti-blooming protection on every pixel, ensuring trace analytes can be accurately measured in the presence of high concentrations of other elements. The hermetically-sealed VistaChip II requires no purging, reducing argon consumption and instrument warm-up time. Computer controlled mirror enables the plasma viewing position to be automatically optimized when the plasma torch is replaced, getting you up and running fast. The CaF 2 prism cross-disperser provides excellent UV performance. The echelle polychromator has no moving parts and is thermostatted to provide excellent long-term stability. The computer-optimized echelle optical design uses fewer components, ensuring high light throughput and better signal-tonoise, detection limits and spectral resolution. 7 For more information visit: www.agilent.com/chem/icpoes

REMARKABLY BETTER SOFTWARE Simplify your workflow The intuitive and user friendly ICP Expert II software has all instrument controls, sample results and signal graphics accessible from one window. Software designed for real samples Easy-to-use worksheet-based software contains wizards and comprehensive multimedia tools to guide you through operation. Fitted Background Correction (FBC) simplifi es method development, eliminating the need to select correction points. This ensures better correction and fast analysis start-up. Agilent s Fast Automated Curve-fi tting Technique (FACT) resolves complex spectral interferences, ensuring greater accuracy in diffi cult matrices. FACT modeling can be conducted post-analysis. AutoMax eliminates manual optimization and provides fast automated method development. Smart Rinse speeds up sample washout, reducing carryover and increasing productivity. Spectroscopy Confi guration Manager software assists you to achieve compliance with the US FDA 21 CFR part 11 rule (optional). MultiCal allows you to monitor results at two or more wavelengths for each element giving you confi dence in the accuracy of your results and extending your measurement range. Time resolved signal mode enables you to couple the Agilent 720/725 to a HPLC or Laser Ablation for fast, multi-element speciation and qualitative applications. Measure the full Echelle spectrum in less than 1 second to quickly identify elements in unknown samples. Collect the spectral data of all elements in your samples without increasing analysis times for retrospective, semi-quantitative capability. Accurate, automatic background correction FBC is a unique, powerful, yet easy-to-use background correction technique that uses a sophisticated mathematical algorithm to model the background signal under the analyte peak. Accurate correction of both simple and complex background structures. No method development required. No need to search for suitable off-peak background correction points for different sample types. A Off peak background correction B Fitted background correction (FBC) C Analytical wavelength D Error without using FBC wavelength Accurate, automatic background correction with FBC FBC calculates the true background signal, improving accuracy and saving time during method development. A C D B 8

REMARKABLY BETTER SOFTWARE FACT spectral deconvolution FACT provides real-time spectral correction by using an advanced spectral modeling technique to mathematically separate the analyte signal from the raw spectrum. Analyze spectrally complex samples with confi dence. Use the FACT wizard to create spectrally pure models of the background, analyte and interferent signals in three simple steps. FACT models can be applied post-analysis and stored for future analyses. MultiCal extends linear dynamic range MultiCal uses the full wavelength coverage and truly simultaneous measurement capability of the 720/725 ICP-OES to extend linear dynamic range far beyond dual-view systems with no time penalty. Combine element wavelengths with different sensitivities to extend linear dynamic range an additional three orders of magnitude. Monitor results at two or more wavelengths for each element and increase accuracy by confi rming they are interference-free. Select the appropriate calibration for the analyzed sample, for fast, accurate measurement from trace to major levels in a single analysis. Dual view systems offering limited wavelength selection only provide a one order of magnitude increase in linear dynamic range and require a separate measurement to do so increasing analysis time and running costs. MultiCal in action Resolve spectral interference with FACT Resolution of the diffi cult Fe interference at Cd 214.438 nm. Shown are: A. Appearance of the peaks in a soil sample, B. FACT model of the interference, C. Corrected signal for the Cd analyte. Sample Labels Ca Mean mg/l Ca 396.847 mg/l Ca 315.887 mg/l Ca 370.602 mg/l Clean water blank 0.00082 0.00082 - - River water 0.811 0.805 0.810 0.817 Sewage effl uent 29.64-29.47 29.80 Industrial effl uent 30.25-30.20 30.29 Bore hole water 175.0-175.1 174.9 1.3E7 Ca 396.847 4E6 Ca 370.602 1E7 0 to 5 mg/l 3E6 0.1 mg/l to 1000 mg/l Intensity 5E6 Intensity 2E6 1E6 0 0 0.000 Concentration (mg/l) 6.050 0.000 Concentration (mg/l) 1210.000 Extend linear dynamic range and confirm results automatically with MultiCal Combine the sensitive Ca 396 nm and less sensitive Ca 370 nm emissions lines to extend the linear dynamic range over 7 orders of magnitude. Combine the Ca 396 nm, Ca 315 nm and Ca 370 nm emission lines and confi rm your results are free from interference. 9 For more information visit: www.agilent.com/chem/icpoes

APPLICATIONS For your application Agilent is committed to providing solutions for your application. We have the technology, platforms, and expert guidance you need to be successful. INDUSTRIAL CHEMICAL & PETROCHEMICAL ENVIRONMENTAL FOOD & AGRICULTURE METALS/MINING 720/725 ICP-OES Pb and Cd in consumer goods such as toys, jewelry and clothing N/P/K, S/Ca/Mg and micronutrients in fertilizers Major, minor and trace elements in brines Metal impurities in pure hydroxides and salts S, P, Ca, Mg, Na, and K in biodiesel (ASTM D6751 & EN 14214) S, P and Cu in ethanol for blending with fuel (EN 15837) Additive elements, wear metals and contaminants in used lubricating oils (ASTM D5185) Major elements in polymers Toxic elements in waters, soils and sediments (US EPA Method ILM05.3) Metals and trace elements in waters and wastes (US EPA Method 200.7) Heavy metals in soils Pb, Cd and Cr in electronics and plastics (WEEE/RoHS) Metals in aqueous wastes containing oils, greases or waxes (US EPA Method 3040A) Trace elements in waters and wastes (US EPA Method 6010) Major, minor and trace elements in foods, beverages and agricultural samples Elemental impurities in pharmaceuticals (USP 232, 233) Extractable cations and nutrients in soils Trace impurities in high purity Cu Au, Ag and Pt group elements in ore grade material Major and minor components in iron, steel and alloys Trace elements in geological samples Environmental, Food and Agriculture In fi elds that demand accuracy, productivity and regulatory compliance, your challenges have never been greater. Today, environmental, food and agricultural analysis must be done more reliably, more effi ciently, and with even higher quality results than ever before. The axially-viewed 720 is optimized to give maximum sensitivity for trace-level applications, including the determination of trace and toxic elements in soils and waters and the determination of major, trace and toxic elements in food and agricultural samples. MultiCal feature extends the linear range of analysis from parts-perbillion to percentage levels, providing the dynamic range needed for simultaneous determinations using one plasma view. The thermally stabilized optics contain no moving parts, ensuring excellent long-term stability so you can satisfy all the required regulatory limits without recalibration. The ICP Expert II software provides complete automation of all US EPA protocols. Customizable QC tests enable you to satisfy the requirements of other regulatory bodies. Double productivity and reduce argon consumption by 50% with the SVS 2 switching valve system. 1.2 1 0.8 0.6 0.4 0.2 0 Ag 328.068 Al 237.312 As 188.980 Ba 585.367 Be 313.042 Ca 315.887 Cd 214.439 Co 228.615 Cr 267.716 Cu 324.754 Fe 238.204 K 769.897 Mg 285.213 Mn 257.610 Na 568.821 Ni 231.604 Pb 220.353 Sb 217.582 Se 196.026 Tl 190.794 V 292.401 Zn 206.200 0:00 0:32 1:01 1:32 2:01 2:31 3:02 3:31 4:01 4:31 5:01 5:32 6:00 6:31 7:01 7:32 8:02 Excellent long term stability Shown is US EPA CLP ILMO 5.3, Continuing Calibration Verifi cation (CCV) solution achieving <1% RSD repeatability for all elements over 8 hours, without internal standardization. 10

REMARKABLY BETTER INNOVATION Metals and mining Whether your challenge is determining traces in the presence of spectrally complex elements such as iron and precious metals which may induce spectral interferences, determining analytes from trace to percentage levels, or handling digests with high levels of dissolved solids, the 725 delivers. The radially-viewed 725 features an effi cient sample introduction system for maximum robustness, allowing you to analyze the most demanding samples with ease and accuracy. Full wavelength coverage and high resolution optics provide fl exibility in wavelength selection so that you can optimize signal-to-noise and eliminate spectral interferences. Agilent s unique MultiCal feature extends the linear range by monitoring your results at two or more wavelengths, providing the dynamic range needed to cover mineralogical samples. ICP Expert II software provides the correction options essential for accurate results. Choose from FBC to handle changing baselines, FACT for fast and easy removal of spectral interferences or more traditional inter-element correction. Industrial, Chemical and Petrochemical Production demands, effi ciency improvements, and good environmental management impose increasingly tough demands on your business. Agilent understands your success depends on fast, accurate results from rugged, reliable instrumentation that can handle diffi cult sample types. Agilent s Atomic Spectroscopy Portfolio: New technologies, more possibilities Agilent has changed the atomic spectroscopy landscape. Remarkable innovations like the ICP-QQQ and MP-AES have added even more application opportunities to those already offered by Agilent ICP-MS, Agilent s 8800 Triple Quadrupole ICP-MS transforms ICP-MS technology, providing applications capabilities and research opportunities never possible before. Agilent s 7700 Series ICP-MS offers unmatched matrix tolerance and interference removal, and the smallest size of any single quadrupole ICP-MS. Agilent s 700 Series ICP-OES is the world s most productive high performance simultaneous ICP-OES. Agilent s plasma generation system is exceptionally robust, and consistently provides stable and accurate results, even with the most challenging samples such as high salts, brines, dissolved solids and complex organics. High resolution echelle optics minimize spectral interferences that can occur in complex chemical matrices. ICP Expert software provides correction techniques such as FBC, FACT or even traditional inter-element corrections essential for accurate results. Optional inert sample introduction system for samples containing hydrofl uoric acid (HF). Optional robust axial and radial sample introduction systems for chemicals, organic solvents and high dissolved solid samples. The revolutionary Agilent 4100 MP-AES runs on air for lowest cost of ownership and improved safety. Agilent s AA range includes the world s fastest fl ame AA and the world s most sensitive furnace AA. 11 For more information visit: www.agilent.com/chem/icpoes

Maximize your productivity and data quality with genuine Agilent parts and supplies From our ICP torch, through to our range of nebulizers and spraychambers optimized for your application Agilent ICP-OES parts and supplies are manufactured to our tight tolerances and stringent specifi cations. They are also rigorously tested to ensure that you ll always get the best performance from your instrument and the best results for your clients. Our catalog of new applications is ever growing. To learn about the latest, contact your local Agilent Representative or visit us at: www.agilent.com Find out how Agilent s Atomic Spectroscopy Solutions can deliver more possibilities for your lab. Trust Agilent to keep your lab running at peak productivity Agilent s Advantage Service protects your investment in Agilent instruments and connects you with our global network of experienced professionals who can help you get the highest performance from every system in your lab. Count on us for the services you need at every stage of your instrument s life from installation and upgrade to operation, maintenance and repair. For customers who require full system validation, Agilent offers complete qualifi cation services for the 720/725 ICP-OES. And if ever your Agilent instrument requires service while covered by an Agilent service agreement, we guarantee repair or we will replace your instrument for free. No other manufacturer or service provider offers this level of commitment. Learn more: www.agilent.com/chem/atomic Buy online: www.agilent.com/chem/store Find an Agilent customer center in your country: www.agilent.com/chem/contactus U.S. and Canada 1-800-227-9770 agilent_inquiries@agilent.com Europe info_agilent@agilent.com Asia Pacifi c inquiry_lsca@agilent.com This information is subject to change without notice. Agilent Technologies, Inc. 2012 Printed in the USA August 16, 2012 5990-6497EN