Technical Note. Introduction

Similar documents
An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Method Translation in Liquid Chromatography

Peptide Mapping: A Quality by Design (QbD) Approach

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

A Modular Preparative HPLC System for the Isolation of Puerarin from Kudzu Root Extracts

Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Genotoxicity is the property of a compound

MassPREP On-Line Desalting Cartridge

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Agilent 1260 Infinity RID User Manual. 9 Maintenance

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Application Note. Author. Abstract. Small Molecule Pharmaceuticals & Generics. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

LC/MS Application Note

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

Fundamentals and Techniques of Preparative HPLC. Parto Zist Behboud Tel: 42108

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Qualification of High-Performance Liquid Chromatography Systems

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

DNA Synthesis With IRDye 700 Phosphoramidite. Part #

BÜCHI Labortechnik AG

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Two-step purification with ÄKTA pure, or ÄKTA avant, using loop collection Cue Card

Preparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions

Flexibility with. Preparative HPLC

ACQUITY UPLC. I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Application Note. Biopharm. Author. Abstract. Christian Wenz Agilent Technologies, Inc. Waldbronn, Germany

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

SFC Säulen für analytische und preparative Anwendungen

Instrument technology moves into process development laboratories

Fast Preparative Column Liquid Chromatography (PCLC)

Streamlined Purification of Assay-Ready Oligonucleotides by Automated HPLC

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

HPLC to UPLC Method Migration: An Overview of Key Considerations and Available Tools

Torch Combustion TOC Analyzer

Prominence Preparative HPLC System

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

Bivalirudin Purification:

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

Laboratory Reagents. for life science research.

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Preparative HPLC System

DCMS Link 2.10 for Compass / HyStar

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Analysis of Monoclonal Antibody Digests with the Agilent 1290 Infinity 2D-LC Solution Part 2: HILIC RPLC-MS

F1 1/10 R&D BIOREACTORS/FERMENTORS

Single-Use Final Fill: Benefits and Considerations

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Biofluids Analysis: Human Serum with High Throughput NMR

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

Protein-Pak Hi Res HIC Column and HIC Protein Standard

AZURA Bio purification

Practical guidance for switching between anion and cation analysis systems

SCION GC Series. The Gas Chromatographers Choice for Separations

Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

System Overview. Valve oven. Restrictor. Valve. Sample in and out

Performing the CTA Carryover PVT Procedure on the LXi or DXC 600i System

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Antibody Analysis by ESI-TOF LC/MS

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

Surface Plasmon Resonance Systems

Separation and Quantitation of a Mixture of Alcohols by Gas Chromatography

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Cleaning Validation PRODUCT OVERVIEW

Certified Reference Material - Certificate of Analysis

ICP Expert software. Technical Overview. Introduction

Aflatoxin & Ochratoxin Analysis. A Completely Automated Solution with the Freestyle, ThermELUTE, and SMART Immunoaffinity Cleanup Columns

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Preparative HPLC is still the

SCION GC Series. The Gas Chromatographers Choice for Separations

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Standard Flexel 3D bioprocessing bags for Palletank (For Europe, Asia and Latin America)

The Opta SFT-D is available as individual device for end-user assembly with TPE tubing and autoclave sterilization.

Relative Quantification (Mono-Color) Unknown samples (purified total RNA, mrna or cdna or genomic DNA)

Agilent 1260 Infinity High Performance Autosampler

Select and price substrates with AMPTS II Light

Transcription:

Online HPLC for Biotechnology: Groton Biosystems Automated Reactor Sampling System and Agilent 1200 Series LC System Technical Note Introduction Online analytical instrumentation facilitates productive, efficient monitoring of fermentation or cell culture processes in real time. The Groton Biosystems Automated Reactor Sampling system (ARS) in combination with the Agilent 1200 Series LC system introduces and complies with the goals of the FDA s Process Analytical Technology (PAT) initiative. Described here is a new technology which introduces automatic, hands-free, online sampling for HPLC analysis. This Technical Note demonstrates this instrumentation for amino acid analysis.

Automated Reactor Sampling Amino acids are important analytes in the clinical, pharmaceutical, biotechnology, and food and beverages industries. It is important to diagnose, monitor processes, and assess the quality of the final products. HPLC is a robust, accepted analytical technique for the separation and identification of very low amino acids concentration. The technique offers both precision and accuracy and that has driven the growth of many applications. Groton Biosystems offers a solution the Automated Reactor Sampling system (ARS) to interface an HPLC system to process lines, purification columns, reactors and fermentors. The ARS communicates with an HPLC system via digital control and status signals to synchronize operations. Sample sequences and the timing of these sequences to acquire an online sample are scheduled to meet the requirements of the process (and the HPLC). The ARS also has an option to provide sample preparation. For instance, if amino acid assays from a bioreactor are required, the ARS sample preparation option separates the protein/peptide fraction from the desired low molecular weight fraction. The ARS system can interface to a variety of bioreactors, fermentors, and HPLC systems. The ARS technology assists companies to comply with the FDA PAT Initiative by providing an automated production tool. This will increase process knowledge and understanding, thus yielding more efficient and profitable operations. A closed loop PAT solution for cell culture and fermentation production is shown in figure 1. Figure 1 A closed loop PAT solution for cell culture and fermentation production. Sterility The proprietary Remote Interface Module has been proven to maintain sterility in bioreactors and fermentors using automatic internal Clean-in-Place (CIP) systems. Steam-in-Place (SIP) is available for large scale systems. A Remote Interface Module is located on, at or near every reactor sample port and provides the mechanism to clean the sample transfer lines and the valves in the module (which controls flow of sample from the reactor to the ARS). This interface provides complete isolation of the reactor or from the ARS and permits cleaning and flushing directly to the reactor port, protecting the reactor from contamination. The Remote Interface Module is equipped with multiple isolation valves in series between the reactor port and ARS, and has at least one drain valve. The ARS performs all functions of sample acquisition, transfer, assay and/or sample storage without contamination of the bioreactor or fermentor. 2

1200 Series 1200 Series 1200 Series 1200 Series 1200 Series 1200 Series HPLC ARS- HPLC connection The Groton Biosystems Automated Reactor Sampling system (ARS400) connects to an Agilent 1200 Series LC system via a 3-way valve and contact closure (figure 2). Binary ARS Reactor Equipment and method ARS400 ARS HPLC interface cable Interface valve ARS method for HPLC Agilent method Agilent 1200 Series LC system 3 groove rotor closure board Agilent interface cables ChemStation Figure 2 Equipment setup. Valve Waste Water NaOH The ARS provides a sterile and automatic connection between a bioreactor sample and an HPLC system. The sterility of the ARS system process for cell culture and/or fermentation media has been demonstrated in Groton Application Note MKT-010. The ARS instrument typically performs a sample prime, sample acquisition, and then system cleaning. The ARS is stored typically in WFI/DI/sterile water when a sample cycle is complete. During the next sampling sequence, the water is displaced by a prime volume and then a 1 ml sample is sent to the Agilent 1200 Series autosampler for sample analysis. The cleaning cycle for this study included a 0.05N NaOH rinse and then 2 successive water rinses. The total cycle time (time from 1 AA injection till the next one) was 30 minutes. ARS- HPLC experimental operation The ARS HPLC experimental conditions are shown in table 1. Closure Board Agilent 1100/1200 LC ALS Injector Figure 3 Instrument schematic HPLC system: Detector: Detector settings: Data collection: Sample: Closure A (twisted pair) Sample Closure B (twisted pair) Purge/Cleaning Valve Drain Sample ARS Closure A controlled by Agilent in HPLC Method: 1/ Closure A a/ Directs sample to 1200 ALS b/ Directs cleaning fluid from ARS to drain 2/ Closure B Controls sequentially Prime Sample Clean Agilent 1200 Series Agilent 1200 Series diode array detector (G1315C) UV 338 nm 10 nm BW, ref. 390 nm BW 20 nm Agilent ChemStation software 9 nmol/ µl asparagine, 9 nmol/ µl glutamine, 5 nmol/ µl norvaline, 5 nmol/ µl tryptophan 0.5 µl OPA (10 mg/ml in 0.4M Borate) + 0.5 µl AA + 2.5 µl 0.4M borate buffer Derivatization: Injection volume: 5 µl HPLC column: ZORBAX Eclipse 4.6 X 50 mm 1.8 µm Column temp: 40 C Flow rate: 2 ml/min Mobile phase A: 10 mm Na 2 HPO 4, 10M m Na2B4O7, 0.5 mm NaN 3 Mobile phase B: Acetonitrile: Methanol: water 45:45:10 HPLC run time: 8 minutes ARS system: ARS400 ARS run time: 30 minutes Table 1 ARS HPLC experimental conditions. 3

mau 300 A mau 400 B 250 200 150 Asparagine Gluatamine Norvaline Tryptophan 300 200 Asparagine Glutamine Norvaline Tryptophan 100 50 100 0 1 2 3 4 5 6 min 0 23 24 25 26 27 28 29 min Figure 4 A) AA analysis when sample injected manually Time from start of injection. B) AA analysis when sample acquired by ARS400 Time from start of acquisition of sample from reactor. ARS- HPLC amino acid analysis Figure 4A shows a manually injected sample separation. Figure 4B shows the ARS delivering the amino acid sample to the HPLC system. Using an HPLC system as an output device Overview ARS sampling systems can be configured to automatically inject samples to an HPLC instrument, either singly or in series. If this function is selected on the Machine Configuration dialog box (figure 5) the ARS will deliver the sample to the HPLC, clean its input and output lines and the HPLC injection loop, and then automatically get the next sample in line and repeat the process. Figure 5 ARS Machine Configuration dialog box. Communication between the HPLC and the ARS The ARS is subordinate to the HPLC and the HPLC instrument control via the Agilent Chem- Station. Once the system is properly configured and connected, the ARS will wait for a signal from the HPLC to inject the sample into the injector loop. It will then wait for a signal from the HPLC to go through a cleaning cycle. When the entire cycle is complete the ARS will wait for the next load command from the HPLC. The signal from the HPLC to the ARS is a simple contact closure through a cable supplied by Groton Bioystems. The cable connects to the ARS via a standard DIN connector and has flying leads to connect to the appropriate connector on the HPLC. 4

This mode of operation is shown in figure 6. The sample can be pulled directly from the reactor to the ARS or it could be supplied through an autosampler with the ARS controlling the autosampler. Mode of operation Sample input (from the reactor to the ARS) is programmed as described in section 4.6 of the operator s manual. Reactor ARS HPLC Figure 6 Mode of operation ARS with HPLC system. When HPLC is selected as the output device, the Output dialog box appears, as shown in figure 7 when the Cycle Parameters dialog box is opened. It will be necessary to edit each of the tabs as described below. The input parameters for the system are edited as described in the operator s manual. The Sample Prime dialog (figure 7) is used to describe the sample priming step which fills the reactor inlet line with sample fluid before the sample is drawn. The Sample Draw dialog (figure 8) is used to indicate the number of times the sample loop should be filled. Figure 7 Cycle prime tab. Figure 8 Sample Draw tab. 5

The Sample Drawback dialog (figure 9) is used to indicate if drawback of the sample is employed to remove sample from the lines after the sample drawback/push is completed. This is used to reduce sample carryover. If this option is used, the Volume and Flow Rate should be indicated. The Cleaning Cycles dialog (figure 10) is used to set the various processes in the cleaning cycle. Figure 9 Sample Drawback tab. The HPLC Parameters dialog (figure 11) is used to set flows through the HPLC interface for cleaning and flushing. The cleaning cycles and reagents are determined based on the sample type being analyzed and actual results obtained during the installation process. Some experimentation may be required. The ARS uses standard 1 mm ID tubing for connections on both the inputs and outputs. The system is supplied with sufficient lengths of this tubing and connector types to allow the operator to handle most interface situations. Connections must be made to the appropriate input and output ports on the ARS and the HPLC. Sample can also be supplied to the ARS manually. Figure 10 Cleaning Cycles tab. 6 Figure 11 HPLC Parameters tab.

Initial operation Once the ARS is programmed and connections are made there are several parameters that must be determined before the combined set up is ready for ongoing operations. The ARS needs to run one sample draw. The ARS will wait until it receives a contact closure signal from the HPLC. Therefore, the HPLC must be programmed to perform a contact closure once the injection loop is in the load position. This contact closure should be held for a period of approximately 5 seconds and then opened. Once the ARS senses closure, it will start its sample draw cycle. This will consist of a sample prime draw and then an actual sample to be delivered to the HPLC injection loop. The ARS will deliver more than the typical 20 µl that is required. The excess must be allowed to flow to waste in the HPLC by plumbing the injector valve with a waste line at port 4. After the ARS has completed its sample process it will then wait for a second contact closure to begin its cleaning cycle. At this point the HPLC is also programmed to inject sample from the loop onto the column and then return the injection loop to the load position and the HPLC should provide the second contact closure to the ARS to start cleaning. This contact closure should also last approximately 5 seconds. The key elements are related to timing within the HPLC protocol. The initial contact closure should not be made for approximately 10 seconds after starting the ARS sample draw. It must be opened again, preferably within a short time after initial closure but allow approximately 5 seconds for the ARS to recognize the signal. Once the HPLC timing is established, the ARS sample draw cycle must be established. The HPLC protocol must allow for this time period adding an additional minute to each method step for margin before closing the injection loop and injecting the sample into the column. The loop should 00:01:00 Initiate HPLC Closure 00:00:30 Start ARS Sample Draw Figure 12 Timing example ARS and HPLC. then be returned to the load position and then the second contact closure needs to be sent to the ARS for cleaning. The cleaning cycle must also be timed so that the HPLC protocol does not request another sample draw from the ARS. This is critical when running multiple sequential sample draws. A typical timeline is shown in figure 12. Note: If any of the ARS set up parameters are changed, it will be necessary to run a new sample cycle to verify the timing required for the HPLC protocol. Set-up changes to the ARS will affect the sample draw and cleaning cycle times. 00:00 00:30 00:01:15 Open HPLC 00:10:30 ARS Sample Draw Complete 00:11:30 Inject Sample into HPLC Column 00:12:30 Flip Loop to Load Position 00:13:35 ARS Begins Cleaning Cycle 00:13:30 HPLC Closure ARS Functions HPLC Protocol 00:13:50 Open HPLC 00:28:35 ARS Cleaning Cycle Complete 00:29:55 Initiate HPLC Closure to Begin New Cycle 7

Conclusion This Technical Note describes a completely automatic, handsfree HPLC system for online analysis. The hyphenated system combines the automatic sampling and reactor sterility protection of the Groton ARS with a high performance amino acid separation system provided by the Agilent 1200 Series LC system. This system is invaluable in applications requiring the combination of sterile sampling and accurate, precise separation and detection of analytes typically found in bioprocesses. Literature 1. MKT-032 Product Bulletin / Agilent Publication Number 5989-6156EN, 2007. 2. Increase Efficiency with a Powerful Process Analytical Technology Solution for the Biopharmaceutical Industry, Agilent in Pharmaceutical Analysis Newsletter Number 18, 2007. www.grotonbiosystems.com www.agilent.com/chem/1200 2007 Agilent Technologies Inc. Published July 1, 2007 Publication Number 5989-6861EN Groton Biosystems Publication Number MKT-047-Rev. B