ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System

Similar documents
EVALUATION SUBJECT: TEEL BQ POLYPROPYLENE (PP-RCT) PIPING SYSTEM

EVALUATION SUBJECT: NIRON POLYPROPYLENE (PP-RCT) PIPING SYSTEM DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING

EVALUATION SUBJECT: UPONOR/WIRSBO hepex TUBING, UPONOR AQUAPEX TUBING AND FITTINGS

EVALUATION SUBJECT: PERMA-LATERAL PULLED- IN-PLACE CURED-IN-PLACE PIPE LINING SYSTEM

PMG-1039 Effective Date: April 1, 2014 This listing is subject to re-examination in one year.

ICC 900/SRCC xx Minimum Standards for Solar Thermal Systems

2015 ISEP INTERNATIONAL SOLAR ENERGY PROVISIONS

EVALUATION SUBJECT: AQUATECHNIK GAS PEX-AL-PEX PIPE AND FITTING SYSTEM

EVALUATION SUBJECT: CURAFLO ENGINEERED FLOW LINING SYSTEMS DIVISION: PLUMBING SECTION: DOMESTIC WATER PIPING.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

EVALUATION SUBJECT: WATTS RADIANTPEX, WATTS RADIANTPEX+, WATTS HEATINGPEX, AND RADIANTFLOW

Reclaimed Water Treatment, Distribution, Pumping and Storage Engineering Report Form

ICC-ES Report. PMG-1009 Reissued 10/2017 This report is subject to renewal 10/2018 EPIPE EPOXY LINED PIPING SYSTEM ACE DURAFLO SYSTEMS, LLC

OG-100 ICC-SRCC TM CERTIFIED SOLAR COLLECTOR # D

EVALUATION SUBJECT: HAMMERHEAD CURED-IN- PLACE PIPE (CIPP) LINING SYSTEM DIVISION: PLUMBING SECTION: SANITARY WASTE AND VENT PIPING

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

Training Certification Categories

EVALUATION SUBJECT: ENAMELED CAST IRON PLUMBING FIXTURES DIVISION: PLUMBING SECTION: PLUMBING EQUIPMENT PLUMBING FIXTURES

Effective Date: January Rev. 3/14/2017- Void After: January Product: Chemical Dispensing Systems File No. 3530

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

REINFORCING TABLES INSTALLATION MANUAL

Baltimore County Detention Center Expansion Towson, Maryland

SECTION SWIMMING POOLS STAINLESS, FULL TILE, OR TILE TRIM

Design & Construction Standards, Revised January

Originally Issued: 03/13/2015 Revised: 03/10/2017 Valid Through: 03/31/ Description

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

PR-L274 Nordic Structures Revised April 16, 2017

Originally Issued: 05/03/2013 Revised: 06/06/2016 Valid Through: 05/31/2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

The 2010 Revision to the ASTM B 813 Standard

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIRESTOPPING REPORT HOLDER: PASSIVE FIRE PROTECTION PARTNERS

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X

An Introduction to Planning Solar Water Heating Systems

C. Foundation stabilization for pipe and utility structures.

Solar Thermal. [Strategy]

CERTIFICATIONS AND LISTINGS

Guideline Specifications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

Power Electronics, Inc. Packaged Equipment Center Standard Construction and Design Features

Sprinkler Identification Numbers (SINs)

SECTION Domestic Water Piping. A. American National Standards Institute (ANSI)/American Water Works Association (AWWA)

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Water Service Inspection Checklist

Property Condition Assessment

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

EVALUATION SUBJECT: PLUMBING SUPPLY FITTINGS

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

Copyright 2017, ProVent Systems Inc., All Rights Reserved

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14

a difficult challenge when trying to achieve effective coverage within a shallow space. The Model CC1 Combustible

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

ESR-3284 Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

Oregon High Performance Home Requirements

SPECIFICATION DIVISION 7 NUMBER SECTION DESCRIPTION DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION THROUGH-PENETRATION FIRESTOP SYSTEMS

EVERHOT INC. Everhot PEX Tubing for Potable Water Applications & Radiant Floor Heating

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

Florida HERO Program Residential Eligible Product List All Products

PLANS REVIEW CRITERIA - COMMERCIAL BUILDINGS

SEPTIC TANK CONSTRUCTION GUIDELINES

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

LP SmartSide Strand Substrate Treated-Engineered-Wood Lap & Panel Siding Louisiana-Pacific Corporation Revised December 2, 2016

EVALUATION SUBJECT: EPA WATERSENSE WEATHERMATIC WEATHER-BASED IRRIGATION CONTROLLERS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

2012 VIRGINIA INDUSTRIALIZED BUILDING SAFETY REGULATIONS

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

December Illinois American Water Cross Connection Control Program

Energy Trigger (A Existing Building Upgrade Mechanism Model)

Section Domestic Water Piping (Hot and Cold Water Potable Water Distribution)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: CARBOLINE COMPANY

Administrative Changes

Division II Contractors

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

ESR-2645 Reissued October 1, 2013 This report is subject to renewal November 1, 2014.

Engineering Design Center. Standard Drawings. 1st Edition -January 2016

EVALUATION SUBJECT: EPA WATERSENSE - HYDROPOINT WEATHER-BASED IRRIGATION CONTROLLERS

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

Fueling the Farm II General Solar Technical Information

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999

Solar Standards Development

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

SECTION COOLING TOWER

Transcription:

ICC-SRCC LISTING SRCC TM Solar Heating & Cooling Code & Standard Listing Program Listing Number: SRCC-16004 Effective Date: May 27, 2017 This listing is subject to re-examination in one year. www.solar-rating.org (888) 422-7233 ICC-SRCC 500 New Jersey Avenue, NW 6th Floor Washington, DC 20001 The Industry Standard Since 1980 A Member of the International Code Council (ICC) Family of Companies CSI: DIVISION: 22 00 00 PLUMBING Section: 22 33 30.23 - Residential Solar Domestic Water Heater System Product certification program: DIVISION: 23 00 00 HEATING Section: 23 56 13 Heating Solar Collectors Section: 23 56 16 Packaged Solar Heating Equipment The SRCC Solar Heating & Cooling Code and Standard Listing Program are conducted in accordance with the latest version of the ICC-SRCC Solar Heating & Cooling Code & Standard Listing Program Guidelines. The program includes evaluation of samples and manufacturer s quality assurance systems to assess continued compliance with applicable codes and standard. Products: Solar Water Heating Systems and Solar Thermal Collectors Listee: Apricus, Inc. 6060 West Manchester, #109 Los Angeles, CA 90045, U.S.A. www.apricus.com (909) 374-9800 Compliance with the following codes: 2012 Uniform Solar Energy Code (USEC)* 2015 Uniform Plumbing Code (UPC)* *Uniform Plumbing Code and Uniform Solar Energy Code are copyrighted publications and trademarks of the International Association of Plumbing and Mechanical Officials (IAPMO) Listing # SRCC-16004 Copyright 2017 Solar Rating and Certification Corporation, TM All rights reserved. Page 1 of 6

Compliance with the following standards and criteria: ICC 901/SRCC 100-2015, Solar Thermal Collector Standard ICC 900/SRCC 300-2015, Solar Thermal Systems Standard SRCC EM-1, Methodology for Determining Compliance with State and Federal Lead in Plumbing Laws for Solar Heating and Cooling Equipment, 10/28/2015. Shows compliance with: o Reduction of Lead in Drinking Water Act, California Health and Safety Code 116875 o Vermont Lead Reduction Law (Vermont Act 193) o Louisiana Reduction of Lead Act (Louisiana Act 362) o Maryland Lead-Free Materials Act (HB 372) o Reduction of Lead in Drinking Water Act (Section 1417, Federal Safe Drinking Water Act) o NSF 372-2010, Drinking Water System Components Lead Content** ** NSF 372 is a copyrighted publication of NSF International. Models: The solar heating and/or cooling products listed below have been evaluated by the Solar Rating & Certification Corporation TM (SRCC TM ), an ISO/IEC 17065 accredited and EPA recognized Certification Body, in accordance with the SRCC Solar Heating & Cooling Code and Standard Listing Program Operating Guidelines, and has been listed by the SRCC to the codes and standards above. This award of listing is subject to all terms and conditions of the SRCC Solar Heating & Cooling Code & Standard Listing Program Agreement and the documents incorporated therein by reference. Where solar collectors are listed, all sizes of the collector model are listed. Solar Thermal Collectors Collector Type Brand Name Model Number SRCC OG-100 Certification Number* Tubular Apricus AP-30C 2007033D Tubular Apricus AP-10 2007033C Tubular Apricus AP-20 2007033B Tubular Apricus AP-30 2007033A Tubular Apricus ETC-10 10001910 Tubular Apricus ETC-20 10001911 Tubular Apricus ETC-30 / ETC-30C 10001909 Glazed Flat Plate Apricus FPC-A40 10001901 Glazed Flat Plate Apricus FPC-A26 10001900 Glazed Flat Plate Apricus FPC-A32 10001899 Listing # SRCC-16004 Copyright 2017 Solar Rating and Certification Corporation, TM All rights reserved. Page 2 of 6

Solar Thermal Systems Brand Name Model Number SRCC OG-300 Certification Number* Apricus APSS_CLOSED_BPHE_AP60_DT-FTD-TBGT 2009151B Apricus APSS_CLOSED_BPHE_AP30_DT-FTD-TBGT 2009151A Apricus APSS_CLOSED_BPHE_AP60_DT-FTD_PBGT 2009150B Apricus APSS_CLOSED_BPHE_AP30_DT-FTD_PBGT 2009150A Apricus APSS_CLOSED_BPHE_AP60_FTD_TBGT 2009149B Apricus APSS_CLOSED_BPHE_AP30_FTD_TBGT 2009149A Apricus APSS_CLOSED_BPHE_AP60_FTD_PBGT 2009148B Apricus APSS_CLOSED_BPHE_AP30_FTD_PBGT 2009148A Apricus APSS_CLOSED_AP60_FTW_TBGB 2009147B Apricus APSS_CLOSED_AP30_FTW_TBGB 2009147A Apricus APSS_CLOSED_AP60_FTB_PBGT 2009146B Apricus APSS_CLOSED_AP30_FTB_PBGT 2009146A Apricus APSS_CLOSED_AP60_FTB_STD-G 2009145B Apricus APSS_CLOSED_AP30_FTB_STD-G 2009145A Apricus APSS_DIRECT_AP60_DT-FTD_PBGT 2009143B Apricus APSS_DIRECT_AP30_DT-FTD_PBGT 2009143A Apricus APSS_DIRECT_AP60_FTD_PBGT 2009142B Apricus APSS_DIRECT_AP30_FTD_PBGT 2009142A Apricus APSS_DIRECT_AP60_DT_FTD_STD-G 2009141B Apricus APSS_DIRECT_AP30_DT_FTD_STD-G 2009141A Apricus APSS_DIRECT_AP60_FTD_STD-G 2009140B Apricus APSS_DIRECT_AP30_FTD_STD-G 2009140A Apricus APSS_CLOSED_BPHE_AP60_DT-FTD_STD-E 2009139B Apricus APSS_CLOSED_BPHE_AP30_DT-FTD_STD-E 2009139A Apricus APSS_CLOSED_BPHE_AP60_DT-FTD-E 2009138B Apricus APSS_CLOSED_BPHE_AP30_DT-FTD-E 2009138A Apricus APSS_CLOSED_BPHE_AP60_FTD-E 2009137B Apricus APSS_CLOSED_BPHE_AP30_FTD-E 2009137A Apricus APSS_CLOSED_AP60_FTB_STD-E 2009136B Apricus APSS_CLOSED_AP30_FTB_STD-E 2009136A Apricus APSS_CLOSED_AP60_FTB-E 2009135B Apricus APSS_CLOSED_AP30_FTB-E 2009135A Apricus APSS_DIRECT_AP60_DT-FTD_STD-E 2009134B Apricus APSS_DIRECT_AP30_DT-FTD_STD-E 2009134A Listing # SRCC-16004 Copyright 2017 Solar Rating and Certification Corporation, TM All rights reserved. Page 3 of 6

Apricus APSS_DIRECT_AP60_DT-FTD-E 2009133B Apricus APSS_DIRECT_AP60_FTD-STD-E 2009132B Apricus APSS_DIRECT_AP30_FTD-STD-E 2009132A Apricus APSS_DIRECT_AP60_FTD-E 2009131B Apricus APSS_DIRECT_AP30_FTD-E 2009131A Apricus APSS_CLOSED_AP60_FTB-2 STD-G 2011078B Apricus APSS_CLOSED_AP30_FTB-2 STD-G 2011078A Apricus APSS_CLOSED_AP60_FTB-E-2 2011075B Apricus APSS_CLOSED_AP30_FTB-E-2 2011075A Apricus APSS_CLOSED_AP30_FTB-2 STD-E 2011072A Apricus APSS_CLOSED_BPHE_AP60_DT-FTD_STD-G 2010046B Apricus APSS_CLOSED_BPHE_AP30_DT-FTD_STD-G 2010046A * Collector and system certifications to the SRCC OG-100 and OG-300 programs may be obtained on the SRCC website at www.solar-rating.org Installation: Solar water heating systems and solar collectors must be installed in accordance with the manufacturer s published installation instruction, the applicable code(s) and this listing. Where differences exist, the instructions in this listing must govern. All individual components of the system which may require periodic examination, adjustment, service and or maintenance must be easily and safely accessible by the owner in accordance with the codes in force at the installation site. Interconnection of the auxiliary system to the solar energy system shall be made in a manner which will not result in excessive temperature or pressure in the auxiliary system or bypassing of safety devices of the auxiliary system. Collectors and support shall be installed in such a manner that water flowing off the collector will not damage the building or cause premature erosion of the roof. Water tanks located in or above the living space shall be installed on a drip pan with a drain line to safely remove any excess liquid. Structural supports shall be selected and installed in such a manner that thermal expansion of the collector and piping will not cause damage to the collector, structural frame or building. Hangers shall provide adequate support and correct pitch of piping and shall be designed to avoid compressing or damaging any pipe insulation material. Control sensors and the means for transmitting sensor outputs to control devices shall be protected from environmental influence such as wind, moisture, temperature or other factors that may alter their intended sensing function. Listing # SRCC-16004 Copyright 2017 Solar Rating and Certification Corporation, TM All rights reserved. Page 4 of 6

Conditions of Listing: 1. System components shall be installed in accordance with the manufacturer s published installation instructions and the applicable code(s). 2. System components requiring access for maintenance and inspection shall be installed to provide required access in accordance with manufacturer s instructions and local codes. 3. Systems and components shall be installed in accordance with the requirements of ICC 900/SRCC 300, Section 503 of the IPC, Chapter 5 of the UPC and Chapter 3 of the USEC and must provide provision for bypass, adjustment or override controls as are required to facilitate installation, startup, operation, shutdown and maintenance. 4. Systems utilizing a non-potable heat transfer fluid must not be connected to the potable water system except through the use of approved devices such as backflow preventers or double-walled heat exchangers. 5. Systems shall be sized in accordance with the demand, manufacturer s requirement, and local codes. 6. Systems shall not be installed below flood elevation level. 7. Systems shall only be used with water or aqueous solutions of ethylene glycol or propylene glycol up to 100% concentration per manufacturer s requirements. 8. Relief valves shall discharge to an approved receptor for disposal in accordance with local codes and requirements. 9. Each installation must be pressure-tested for leaks in the presence of the code official or code official s designated representative. 10. When installation is in fire-resistance-rated assemblies, evidence of compliance with IBC Section 712 (penetrations) must be provided to the code official for approval. 11. System components shall be assembled such that firestopping shall be possible at the time of installation, if required by local codes and ordinances. 12. Devices and components shall not reduce or increase humidity, temperature or thermal radiation beyond acceptable levels or interfere with required headroom or air circulation space. 13. Neither wind loading nor the additional weight of filled collectors shall exceed the live or dead load ratings of the building, roof, roof anchorage, foundation or soil. Collector supports shall not impose undue stresses on the collectors. The design load shall be as specified by the codes in force at the installation site and shall include and additional load due to snow accumulation for applicable locations. 14. Piping should be sloped toward drain ports with a drainage slope of no less than 2 cm of vertical drop for each meter of horizontal length (1/4 inch per foot). Underground piping shall be installed to withstand surface loads. The trenches and backfill shall be free of sharp objects in contact with the pipe. 15. Field-applied pipe and tank insulation shall comply with local code requirements for thermal insulation value, flame spread, smoke development and finishing. 16. System components shall be compatible with contacting fluids. Components and devices contacting potable water shall comply with NSF 61 and Federal Safe Drinking Water Act requirements for lead content. 17. Devices and components are manufactured by Apricus, Inc.. under a quality control program with surveillance inspection every other year conducted in accordance with the requirements of ICC-SRCC. Listing # SRCC-16004 Copyright 2017 Solar Rating and Certification Corporation, TM All rights reserved. Page 5 of 6

Marking: Models listed above were evaluated to the codes and standards listed in accordance with the SRCC Solar Heating & Cooling Code Listing Program Guidelines and are eligible to display the following mark as governed by the SRCC Solar Heating & Cooling Code Listing Program Agreement. Each device or component shall also be permanently marked with manufacturer s name or trademark, model name and/or number, recommended working fluids, maximum working temperature and pressure, and recommended flow rate(s). All warning lights, switches and controls shall be clearly identified. Where the pump station includes electrical components, the station shall be labeled with the electrical rating in volts, amperes and motor phase. Any operation, maintenance and installation instruction manuals from the manufacturer shall be supplied with the pump station. Supplier s contact information shall be included with these documents. Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by the Solar Rating and Certification Corporation, express or implied as to any finding or other matter in this listing, or as to any product covered by the listing. This document must be reproduced in its entirety. Listing # SRCC-16004 Copyright 2017 Solar Rating and Certification Corporation, TM All rights reserved. Page 6 of 6