RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Similar documents
MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

THERMAL-FLEX ICF INSULATED CONCRETE FORMS COATING ASSEMBLY TO ICF BLOCK MANUFACTURERS SPECIFICATIONS / SECTION STUC-O-FLEX PART 1 - GENERAL

SECTION CONCRETE AND MASONRY COATINGS

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

Section COATING RESTORATION

THERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

Direct Finish System for Soffits and Ceilings Only Senerflex lamina applications to soffits and ceilings

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

ACF for Soffit Specifications

PRODUCT GUIDE SPECIFICATION

Technical Data Sheet

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

3910 E. McKinney Denton, TX P.O. Box Dallas, TX EZ WALL CONCENTRATE, INC

TOPCOAT System Specifications Corrugated Transite Panels

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

TOPCOAT Restoration Specifications Structural Concrete

GigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls

***********************************************************************************

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

Pacific Polymers Elasto-Deck BT Guide Specification

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

SECTION CONCRETE PAVING SLABS SET IN MORTAR

ZYCOSIL WATER REPELLENT

PRODUCT SPECIFICATIONS

KOSTER AMERICAN CORPORATION

SPECIFICATION GUIDELINE

Application Specification:

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

SECTION Pedestrian Traffic Coatings{PRIVATE } 1.1 SUMMARY (Specification writer shall add, delete or amend, as deemed necessary)

GE SCM3500 High Solids Silicone Roof Coating

Senergy Base Coats / Adhesives Fast setting dry-mix polymer adhesive. Product Bulletin

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins.

SIDER-POOL. Product Data. Features and Uses

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

FLOORING INSTALLATION SYSTEMS. Product Catalog

By CTS Cement Manufacturing Corp.

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

Corium Brick Rainscreen System Specifications

Custom Polishing Systems

SECTION A. American Society for Testing and Materials (ASTM):

RESILIENT FLOORING: Select Step Wood

8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane

MasterSeal HLM Liquid cold-applied elastomeric waterproofing membrane system

Instruction Guide APPLICATION OF CIM TO CONCRETE

CEMENTITIOUS CRYSTALLIZING WATERPROOFING PART 1 GENERAL

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

Broadcast Parking Garage System

Refer to Substrates & Surface Preparation.

CSI SECTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

VB (Vapor Barrier) R Guard

Florock Seamless Flooring Systems

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

SUPER-KRETE SPECIFICATION S-1 EXISTING CONCRETE SURFACE PREPARATION SECTIONS ; /19; ;

Section Fluid Applied Waterproofing

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

ARDEX GUIDE SPECIFICATION ARDEX K 521 Self-Leveling Concrete Topping with Aggregate Surface

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

VB fluid-applied air & water-resistive barrier and water vapor barrier

MANUFACTURER'S SPECIFICATIONS Section ST. ASTIER LIME PLASTER (NHL) PLASTER ON CONCRETE

AVM System 500. Aussie Membrane 500

RESILIENT FLOORING: Hot and Heavy - Secoya

AIR BARRIERS & WATER-RESISTIVE BARRIERS

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

SECTION HYDRAULIC CEMENT UNDERLAYMENT

EDGEWATER, FLORIDA JUNE 14, 2010

Product Guide Specification

SL150 Guide Specification

SECTION SELF-ADHERING SHEET WATERPROOFING

SECTION RIGID PAVEMENT. 1. Portland Cement Concrete (PCC) pavement. 2. Section Aggregate Base Course.

QUALITY COATING & REPAIR PRODUCTS

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

FLUID APPLIED ROOFING - HYPALON ROOF RESTORATION

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

DIVISION 9 FINISHES Section Floor Finishes

Kolorines Glass Mosaic Tiles Project Specification

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL. A. Two component liquid waterproofing for positive side waterproofing on mineral substrates

Narrow Modular Pavers (NMP) for Sand-Set Installations

CSI SECTION MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials

SECTION SILOXANE WATER REPELLENTS

SECTION EPOXY TERRAZZO

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

Aliphatic Acrylic-Polyester Polyurethane

POLYMER CONCRETE 100 EPOXY POLYMER CONCRETE DILUTE ACIDS RESISTANCE

VB fluid-applied air & water-resistive barrier and water vapor barrier

Application Specification:

DIVISION 3 HEAVY DUTY CONCRETE FLOOR TOPPING SECTION 03340

Installation Guide LVP Glue Down

1. Rapid Set Cement. 2. Methods of preparation. 3. How to stage a job site. 4. Installation Mix, place, finish. 5. Coloring the TRU.

Transcription:

STUC-O-FLEX RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION 09 97 23 PART 1-GENERAL 1.00 SCOPE: Manufacturer's specifications containing the requirements necessary for proper installation of the Stuc-O-Flex RENEW Elastomeric Coating (Paint Grade) over a properly prepared substrates. 1.01 DESCRIPTION A. Provide all labor, materials, and equipment necessary to install the field applied Stuc-O-Flex RENEW Elastomeric Coating (Paint Grade). B. Related work specifications: 1. Section 03 30 00 / Cast-in-Place Concrete 2. Section 03 41 00 / Precast Structural Concrete 3. Section 04 20 00 / Unit Masonry Assemblies 4. Section 07 02 40 / Exterior Insulation and Finish System 5. Section 09 96 00 / Acrylic Textured Finish 6. Section 09 24 00 / Portland Cement Plastering 1.02 QUALITY ASSURANCE A. Qualifications: 1. Manufacturer Qualifications: Company with minimum 15 years of experience in manufacturing of specified products 2. Applicator Qualifications: Company with minimum of 5 years experience in application of specified products on projects of similar size and scope, and is acceptable to product manufacturer. a. Successful completion of a minimum of 5 projects of similar size and complexity to specified Work. B. Field Sample: 1. Contracted applicator shall provide one (1), 2' by 2' foot sample for each color selection. This will be fabricated using the same tools, equipment and techniques as intended for project installation. Install at project site or preselected area of building, using specified material. 2. Apply material in accordance with manufacturer s written application instructions. 3. Approved samples shall be maintained throughout project construction in order to judge completed work for acceptance. 4. Do not destroy sample until application is complete and approved. 5. Obtain Architect s written approval of sample before material application, including color and texture. 6. Perform adhesion tests if any questionable areas are encountered

C. Prior to starting, obtain appropriate approvals from architect and / or building owner. D. Approved samples shall be maintained throughout project construction in order to judge completed work for acceptance. E. Stuc-O-Flex Renew Specifications and Specimen Warranty 1.04 DELIVERY, STORAGE, AND HANDLING A. Materials shall be delivered in original unopened packages with labels clearly visible. B. Products shall be stored out of direct sunlight, protected from the weather, tightly sealed at temperatures above 40 F. C. Do not allow product to freeze. D. Do not apply over moving cracks, control joints, or expansion joints. E. Do not apply to horizontal traffic-bearing surfaces 1.05 JOB CONDITIONS A. Ambient temperatures shall be 40 F or greater at time of installation, and will remain so for a minimum 24 hours or protection and heat must be supplemented to insure proper drying. B. Product installation shall not take place during inclement weather unless adequate protection is provided both during application and until cured. Protect materials from rain or freezing temperatures until dried. C. High humidity conditions (fog, mist, etc.) can significantly extend drying time. 1.06 LIMITED WARRANTY A. Upon proper installation of STUC-O-FLEX RENEW; a standard product warranty will be issued.

1.07 PERFORMANCE REQUIREMENTS (MINIMUM) A. TEST METHOD RESULT ELONGATION % (FINISH) WATER VAPOR TRANSMISSION ASTM - 1653 SALT SPRAY RESISTANCE B-117 ACCELERATED WEATHERING ASTM D 4587 ASTM D 2370 305 Percent 7-10 GRAINS PER HOUR (AVERAGE) 300 HOURS NO DELETERIOUS EFFECTS 2000 HOURS NO DELETERIOUS EFFECTS ABSORPTION FREEZE THAW 60 CYCLES NO CRACKING, CHECKING TENSILE BOND ASTM D 2370 200 PSI WATER PENETRATION TEST ASTM-E-331 WATER RESISTANCE TEST ASTM D-2247 MILDEW / FUNGUS RESISTANCE 810 B NO WATER PENETRATION OCCURRED ON SUBSTRATE NO CRACKING, BLISTERING, PEELING OR COMPROMISE NO MOLD OR MILDEW GROWTH DURING TEST WIND DRIVEN RAIN TTC 555 MAX. 0.2 LBS GAIN FIRE TESTING TUNNEL TEST ASTM E-84 FLAME SPREAD < 25 SMOKE DEVELOPED < 450 CLASS "A" FIRE RATED FUNGUS RESISTANCE ASTM D 3273 MINIMUUM 8 / NO GROWTH LOW TEMPERATURE FLEXIBILITY ASTM D 1737 NO CRACKING PART 2 - PRODUCTS 2.01 GENERAL A. In accordance with these specifications all materials required for the installation of RENEW shall be obtained from STUC-O-FLEX INTERNATIONAL unless otherwise approved in writing. Stuc-O-Flex International Inc. 17639 NE 76 th Court Redmond, WA 98052 1-800-305-1045 425-885-5085 / www.stucoflex.com 2.02 MATERIALS A. PRIME SEAL, (Acrylic based stain blocking primer), protects substrate from moisture, creates uniform porosity and prevents bleed through which could discolor finish coat. (optional - as required / contact technical service) (Optional as required)

B. ELASTOMERIC JOINT COMPOUND, Stuc-O-Flex Elastomeric Joint Compound offers new technology in flexible sealants. This ready to apply product is specifically designed for treatment of cracks, butt joints or seams in existing surfaces prior to application of Stuc-O-Flex Renew. Stuc-O-Flex Elastomeric Joint Compound is the first component used prior to Prime Seal or Stuc-O-Flex Renew (as required for cracks in the substrate / contact technical service) C. STUC-O-FLEX RENEW, as manufactured by STUC-O-FLEX INTERNATIONAL, factory premixed, 100% acrylic based, color integrated, elastomeric finish for use as a decorative protective membrane. Provided in 20 standard colors, special colors upon request, See STUC-O-FLEX standard color chart. D. WATER shall be clean and potable in clean containers without any residue or foreign materials. E. Sealant system shall be of appropriate quality to prevent water intrusion. Consult manufacturers for specific details and specification. 2.03 MIXING AND PREPARATION A. PRIME SEAL: Mix to a uniform consistency (do not add water) B. ELASTOMERIC JOINT COMPOUND: Mix to a uniform consistency. C. STUC-O-FLEX RENEW : Using a paddle type mixer agitate material until a homogeneous consistency is obtained. Care should be taken so as NOT to introduce air into finish coat material. D. Never add modifiers, admixtures or other products not specified to any STUC-O-FLEX manufactured products. PART 3 EXECUTION 3.01 INSPECTION A. Substrate shall be examined for compliance with construction documents and system specifications prior to application of the Stuc-O-Flex Renew. B. Architect and/or General Contractor will be made aware of any such substrate concerns. Any problem areas shall be rectified before installation may continue. C. The minimum slope of any surface shall not be less than 4" in 12". D. To insure performance substrate system shall be engineered with regard for intended installation. E. Do not use below grade or on surfaces subject to hydrostatic pressure F. Substrates shall be cured, clean, dry, and free of form oil, curing compounds or bond breaker. 3.02 INSTALLATION A. SUBSTRATE: shall comply with Section 1.02 General listed above, prior to product applications. B. ELASTOMERIC JOINT COMPOUND: Using a stainless steel trowel or sheetrock knife apply Joint Compound mixture to all cracks larger than 1/32 inch providing a smooth finished appearance.

1. Allow to dry minimum 24 hours or until dried below 15% moisture content. C. PRIME SEAL (Optional): Apply primer with airless sprayer, medium nap roller, or paint brush to all areas which Stuc-O-Flex Renew is to be applied. A uniform pinhole free layer should be provided to insure no shadowing or discoloration will occur from the Stucco substrate. 1. Allow to dry completely. D. STUC-O-FLEX RENEW ELASTOMERIC COATING, Apply in color as approved by Architect and/or Client using or appropriate spray equipment or rollers with sufficient manpower and equipment to insure a continuous operation without cold joints, scaffolding lines, etc. Finished wall sections shall match approved job site sample. Coverage and thickness shall vary depending on substrate, method of application. Alyhough to assure proper material thickness, coverage will average approximately 800 Sq. Ft. per 5-gallon pail 1. Mix STUC-O-FLEX RENEW prior to use with paddle type blade to insure consistency. 2. Small amounts of water may be added to adjust viscosity. 16oz. maximum per 5-gallon pail. 3.03 JOB SITE CLEAN UP A. STUC-O-FLEX applicator shall remove all excess materials from completed project areas. B. Coverings, scaffolds, etc. shall be removed.