SUPPLIER DISPOSITION REQUEST

Similar documents
NON-CONFORMING MATERIAL

Nonconforming Material System Procedure

Quality Management System

FAA Conformity Inspection Checklist Form N/C 10JAN16

INS QA Programme Requirements

Supplier Quality Manual

Centerwide System Level Work Instruction

PMA Quality Assurance Manual Rev. 2 Date 12 Feb 2016

CALCULATION COVER SHEET

Association of American Railroads Quality Assurance System Evaluation (QASE) Checklist Rev. 1/12/2017

Quality Manual ISO 9001:2000

Page 1 / 11. Version 0 June 2014

SAN FRANCISCO PUBLIC UTILITIES COMMISSION INFRASTRUCTURE CONSTRUCTION MANAGEMENT PROCEDURES

Desk Audit of. Based on Federal Transit Administration (FTA) Quality Assurance and Quality Control Guidelines FTA-IT

NONCONFORMANCE DOCUMENT VENDOR REQUEST FOR VARIATION

QUALITY OPERATIONS STANDARD

Association of American Railroads Mechanical Division MANUAL OF STANDARDS AND RECOMMENDED PRACTICES

2.2. The Seller shall be responsible for achieving and maintaining a quality performance level of either:

LM Logistic Services Quality Notes Conversion Chart

Quality Management System Manual

Korea Aerospace Industries, Ltd. KAI Procurement Quality Management System Requirements for Suppliers (KPQMS 9100)

SHELTON INDUSTRIAL PATTERN INC.

FAIRFIELD GLOBAL SUPPLIER QUALITY PROGRAM

CODE: FD10 Rev: A Date: 9/24/2008 CONFIGURATION MANAGEMENT

External Provider Quality Requirements QCS-001 Processing Sources

Work Instruction PUI Supplier Request for Nonconforming Material (Rev 2)

ZOLL Document Number: 90E0004 Page 5 of 15 Maintenance of Quality Records

In case of of differences or inconsistencies with texts in the Main Contract, the stipulations in this Appendix I will prevail.

ViaSat, Inc. Quality PR Third Party Inspection Services, PWB Verification and DPA Samples Quality 1 of 12 Purpose and Scope

ITER Quality Assurance

Definitions contained in the above mentioned document and industry regulations are applicable herein.

Supplier Quality Manual PREPARED AND MAINTAINED BY FIRESTONE INDUSTRIAL PRODUCTS COMPANY DIVISION OFFICE 250 W. 96 th Street INDIANAPOLIS, IN 46260

BAITY SCREW MACHINE PRODUCTS QUALITY MANUAL

Appendix QI. Intra-Lockheed Martin Work Transfer Agreement (IWTA) Quality Requirements for Deliverable Items

TITLE: Quality Assurance Sub-Contract Quality Clauses DATE: 12/4/2017 OWNER: Operations Manager

Controlled By: QA Mgr. / Gen. Mgr. Effective Date: 3/31/2014 FORM-70

Quality Assurance Policy and Procedures

4. RELATED DOCUMENTS AND FORMS 4.1. AS ISO Cambridge Valley Machining, Inc. QMS procedures, including, but not limited to:

QUALITY DEPT request to have FORM 1135 for REVIEW/APPROVAL Cycle everytime form will be updated/revised.

SECTION QUALITY REQUIREMENTS

CORPORATE QUALITY SYSTEM PROCEDURE

Mantor Aviation Company

This procedure covers evaluating and analyzing supplier for addition to the Approved Supplier List (ASL) and performance evaluation.

Flooring Contractor QA/QC Plan Sample Selected pages (not a complete plan)

ANCHOR ISO9001:2008 RPR-004 MARINE SERVICES REQUIRED PROCEDURE NON-CONFORMING PRODUCTS

EPICOR, INCORPORATED QUALITY ASSURANCE MANUAL

U.S. Technical Advisory Group to ISO/Technical Committee 207 Clarification of Intent of ISO 14001

NR CHECKLIST Rev. 1. QAM IMP References NBIC Part 3, 1.8 Y N Y N a. Organization. Company Name/Certificate Number: Page 1 of 26

FO-5 PR-1, FO-1,2 PR-1 EM-6 PR-1, FE-1, NA-1 FO-10 FO-7, EM-2 EM-2. ISO Environmental Management Systems - Specification Yes.

Quality Manual Revision: C Effective: 03/01/10

ROTEK. IIInnInstI Instrument Corp. ISO 9001 Quality System Manual

ZODIAC INTERCONNECT US ZODIAC AEROSYSTEMS SEGMENT ZODIAC INTERCONNECT DIVISION

How to Set Up a Quality Assurance System A Step by Step Guide to Quality Control Management System

PCX Aerostructures, LLC Quality Notes Supplier Quality Assurance Requirements - Quality Clauses Revision 29 - March 30, 2017

PPI/TZ Standard Quality Requirements for Suppliers -SQRS-

QUALITY MANAGEMENT SYSTEM MANUAL ISO 9001:2008

JUL 14 Rev B All Paragraphs Revised

Corrective Action(s) System Procedure

Instructions for Supplier Survey

Digital Supplier Handbook

QM-001(Rev. 1) 1.0 INTRODUCTION. 1.1 Scope

Supplier Rating System (SRS)

ISS PRE-SHIPMENT AND ACCEPTANCE REVIEW CHECKLIST AND GUIDELINES FOR DELIVERY OF HARDWARE ACCEPTANCE DATA PACKAGE (ADP)

QUALITY MANUAL W.R. Larson Rd. P. O. Box San Antonio, Texas San Antonio, Texas (830) (210) FAX

Supplier Quality Manual

Oil and Gas Contractor QA/QC Plan Sample Selected pages (not a complete plan)

NRC INSPECTION MANUAL INSPECTION PROCEDURE 35065

QUALITY MANUAL DISTRIBUTION. Your Logo Here. Page 1 1 of 57. Rev.: A

FLYSHEET 100 Rev. 14 QUALITY SYSTEM REQUIREMENTS

QUALITY ASSURANCE MANUAL. D SECTION XV: Revision A SUBJECT: INSTRUCTIONS FOR COMPLETING AN ELECTRONIC SUPPLIER INITIATED REJECTION REPORT.

Limited Shelf Material Control Procedure

IMMEDIATE POLICY CHANGE

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

QUALITY MANAGEMENT SYSTEM POLICIES AND PROCEDURES

Instructions For Populating GFP Attachments

Report number A0436 PRODUCT REQUIREMENTS FOR SELLERS OF BOEING DESIGNED DETAIL PARTS AND NON-FUNCTIONAL MINOR ASSEMBLIES

TOOL ENGINEERING OLD GROVE RD. SAN DIEGO, CA

SUPPLIER MANUAL. Griffith Rubber Mills - HQ 2625 Northwest Industrial Street Portland, Oregon 97210

Work Instruction PUI Supplier Request for Nonconforming Material (Rev 1)

Approved Supplier Guidance

ZOLL Document Number: 90F1087 Page 3 of 18 MES/ERP Nonconforming Material Transaction Instructions REV B

CQR-1. CONTRACTOR QUALITY REQUIREMENTS for CONSTRUCTION SERVICES Revision Date: 6/8/2015

AS9003A QUALITY MANUAL

QUALITY ASSURANCE SPECIFICATION WELDING HEAT TREATMENT PAGE 1 OF 6

Quality Clauses F Rev. I West Brooks Avenue North Las Vegas, NV Phone (702) Fax (702)

ASA-100 QUALITY MANUAL

Quality Manual. Specification No.: Q Revision 07 Page 1 of 14

SRCTec, Inc. SUPPLIER QUALITY CLAUSES (SQC S)

METUCHEN CAPACITORS INCORPORATED. Quality Manual P.O. BOX HIGHWAY 35, SUITE 2 HOLMDEL NJ USA

12. Inventory - Receiving & Shipping

Supplier Quality Manual

SUPPLIER QUALITY ASSESSMENT

GKN Aerospace - St. Louis Supplier Quality Assurance Manual

Supplier Approval and Performance Evaluation

2. GENERAL REQUIREMENTS

P&W Supplier Tooling Package Guidelines

CURTISS WRIGHT Actuation Systems 201 Old Boiling Springs Rd Shelby, NC SUPPLIER QUALITY REQUIREMENTS SQR-100. Rev. L.

Clause "A" Subcontractor Controls, General Requirements (Applicable when Clause "A" is invoked in the Purchase Order "Remarks")

Altech Machining, Inc. Terms and Conditions

NUCLEAR SAFETY REQUIREMENTS BSR

Transcription:

Contractor CAGE Code: 4V360 3550 General Atomics Ct San Diego, CA 92121-1122 SUPPLIER DISPOSITION REQUEST DR NO.: REV.: PAGE: of (3) PART NOMENCLATURE: (4) DWG/PART NO.: (5) REV.: (6) LOCATION: (7) DATE: (8) SUPPLIER NAME: (9) SUPPLIER ADDRESS: (10) MFR CAGE CODE: (11) GA-EMS BUYER: (12) P.O. NO.: (13) P.O. LINE : (14) LOT SIZE: (15) QTY INSP: (16) QTY NOT ACC.: (17) LOT/SERIAL NO.: (18) DISCOVERED IN: (19) INSPECTION CRITERIA: Receiving In-Process Final Other Design Document Inspection Instruction Other (20) REQUIREMENTS (21) NONCONFORMING CONDITION (22) PROPOSED DISPOSITION, CAUSE, AND CORRECTIVE ACTION (23) ATTACHMENTS: (24) PREVIOUS SDR/NR NO.: (25) INITIATOR: FOR GENERAL ATOMICS ELECTROMAGNETIC SYSTEMS USE ONLY (26) CONTRACT NUMBER: (27) HWCI PART NO.: (28) HWCI NOMENCLATURE: (29) WBS NO.: (30) PROJECT NO.: (31) SCHEDULE A NO: (32) CSI? YES NO (33) CLASSIFICATION: (34) ECR: NONCONFORMANCE: Critical Major Minor DESIGN CHANGE: Class I Class II INFORMATION ONLY: (35) DISPOSITION: (36) DISPOSITION & TECHNICAL JUSTIFICATION: Use-As-Is Repair Re-Work Scrap Information Only Modify (Design Change ONLY) ECR No: Date Issued:

SUPPLIER DISPOSTION REQUEST SDR No. Rev. (continuation page) AGE: FOR GENERAL ATOMICS ELECTROMAGNETIC SYSTEMS USE ONLY (Continuation Sheet) (37) CAUSE OF DISCREPANCY: (38) DEFECT CODE(s): (39) CAUSE (40) CORRECTIVE ACTION: (41) CORRECTIVE ACTION CODE(s): (42) CAUSE RESPONSIBILITY: (43) CORRECTIVE ACTION (BLOCK 44) VERIFICATION: GA-EMS: Supplier Other: (44) CAR REQUIRED? YES NO CAR No.: Date Issued: EFFECT INFORMATION: (45) EFFECT ON CONTRACT COST/PRICE: (46) EFFECT ON DELIVERY SCHEDULE: (47) EFFECT ON LOGISTICS SUPPORT, INTERFACE, OR SOFTWARE: GENERAL ATOMICS ELECTROMAGNETIC SYSTEMS SIGNATURES: (48) DESIGN ENGINEERING: (49) OTHER TECHNICAL: (50) ENGINEERING: (51) ENGINEERING MANAGER: (52) QUALITY ASSURANCE: (53) GA-EMS INTERNAL MATERIAL REVIEW BOARD (IMRB): CUSTOMER MATERIAL REVIEW BOARD: (54) GA-EMS CO-CHAIR: (55) CUSTOMER CO-CHAIR: DISPOSITION ACTION COMPLETED: (56) QTY ACC: (57) QTY NOT ACC: (58) NEW SDR/NR NO: (59) SUPPLIER OR GA-EMS INSPECTOR OR QA REPRESENTATIVE: (60) OTHER SIGNATURES (AS NEEDED) (61) GA-EMS QE VERIFICATION OF IMPLEMENTED DISPOSITION AND C/A SDR CLOSED

SUPPLIER DISPOSTION REQUEST SDR No. Rev. (continuation page) PAGE: of

Responsible Person Supplier 1 SUPPLIER DISPOSTION REQUEST (continuation page) PAGE: 4 Instructions to Supplier for Completing form EMS-0196 Supplier Disposition Request Block Title Description SDR No. & Revision Supplier 2 Page 1 of The SDR number consists of two parts. The first part is the GA-EMS PO number, and the second part is a three or more digit sequential number (for each PO) that is assigned by the supplier, who manages an SDR number log to avoid duplication or gaps. A letter is used to indicate subsequent revisions of the SDR. Fill in the total number of pages in the SDR, including continuation pages. Do not include the attachment pages; those are documented in Block (23). Supplier 3 Part Nomenclature Part Nomenclature from the drawing or specification. Supplier 4 DWG/Part No. Enter the Drawing Number of the Part that is nonconforming, requiring information, or design change suggestion. List the lowest level part number that the Supplier has. If no drawing number exists, then list the applicable specification number. Supplier 5 Rev. Revision of the Drawing or Spec. Supplier 6 Location Current physical location of the part. Supplier 7 Date The date of occurrence or discovery of the nonconformance, design modification, or information request. Supplier 8 Supplier Name The name of the organization on the GA-EMS PO. Supplier 9 Supplier Address The location of the manufacturing facility of the Supplier in Block (8). Supplier 10 Mfr CAGE Code Supplier's Contractor and Government Entity (CAGE) Code for the Manufacturing facility. Supplier 11 GA-EMS Buyer Name of the GA-EMS Buyer listed on the GA-EMS PO. Supplier 12 PO No. Enter the GA-EMS PO number. Supplier 13 PO Line Item Enter the PO Line Item(s) for the nonconforming part(s). Supplier 14 Lot Size Size of the Lot. Supplier 15 QTY Insp. Quantity of Items that were Inspected. Supplier 16 QTY Not Acc. Quantity of Items that were not accepted. Supplier 17 Lot/Serial No. Serial Number of nonconforming item, if applicable. If more than one Serial Number, enter "see Block (21) and include the Serial Numbers in the nonconformance description. If multiple nonconforming parts that are not serialized, attach temporary identification tags with "Unit 1," "Unit 2," etc., if necessary to clarify which nonconformance description applies to each unit. Supplier 18 Discovered in Check the box indicating the part of the manufacturing process in which the issue was discovered. For Other, specify the process. Supplier 19 Inspection Criteria Check the box indicating the type of criteria used to determine the issue. For Other, specify the criteria. Supplier 20 Requirements State the required condition, and note the applicable specification number and paragraph or drawing number and location. Describe it quantitatively, be complete, and be concise. Identify any interfacing items affected by the reported or proposed condition. For multiple items, give each a sequential item number in the Item column.

Responsible Person Supplier 21 Supplier 22 SUPPLIER DISPOSTION REQUEST (continuation page) PAGE: 5 Block Title Description Nonconforming Condition Proposed Disposition, Cause and Corrective Action Supplier 23 Attachments Supplier 24 Previous SDR/NR No. Identify the actual nonconformance, design modification, or information request. Describe it quantitatively, be complete, and be concise. Identifying any interfacing items affected by the reported or proposed condition. For multiple items, number them with the corresponding item numbers used in Block (20). Provide a clear, concise justification for any proposed changes. Identify any attachments submitted with the SDR. Include the attachment title and number of pages in each attachment. A repair procedure, including the method of verifying acceptability, is required for any repair dispositions. A design modification procedure, including a provision for acceptability verification, is required for any modification dispositions. Sketches or photographs are recommended to add to the clarity of the description of the nonconforming condition or design modification, or recommended disposition. Previous NRs/SDRs that apply to the item covered by the SDR and had similar causes and affected other items supplied to GA- EMS. Identify by NR/SDR number(s). Supplier 25 Initiator The originator shall sign as indicated. Supplier 56 QTY ACC Enter the quantity of items that are now accepted but were included in Block (16). Supplier 57 QTY NOT ACC. Enter the quantity of items that are still not accepted and were included in Block (16). Supplier 58 Supplier 59 NEW REPORT NO. Supplier Inspector or Supplier QA Representative If one or more items are still not acceptable, document on a new SDR form and list the SDR number here. Sign here to attest to the completion of the disposition actions and indicated quantities in Blocks (56) and (57). After the Supplier implements the GA-EMS-approved disposition, then forward the SDR to the Buyer listed on the Purchase Order.