Chemistry Division, Naval Research Laboratory, Washington, DC 23075

Similar documents
Status of international and domestic regulations on installation and use of ballast water management systems. Draft Report

A new ballast water sampling device for sampling organisms above 50 micron

Update on California s Marine Invasive Species Program

UV Treatment of Ballast Water: Market, Regulations, Validation Test Methods

Ballast water treatment market. Opportunities for technologies in the light of regulation changes

Ballast Water Management

Choosing The Correct Flow Meters For Hydraulic Fracturing

Ballast Water and EPA s Vessel General Permit. Ryan Albert U.S. Environmental Protection Agency May 9, 2014 Presentation for Intertanko Workshop

CHAPTER 6 : GAS SAMPLING SYSTEMS

VENTURI FLOW METER CALIBRATIONS SERIAL NUMBERS: , , , Prepared for. Imperial Flange and Fitting.

Water flow measurement in the oil and gas industry

Challenges in the Installation and Operation of Ballast Water Treatment Systems. Dr. John Kokarakis

Enviro Voraxial Technology

< ))))>< Final Report

MARITIME OPERATIONS DEPARTMENT MARINE TECHNICAL

Flanged Water Meters (non-continuous flow)

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE

VERIS Accelabar. Superior Flow Measurement Accuracy

Industrial Flowmeters

APlus-QMC LLC. Catalog 2017

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

TVA Target Variable Area Flowmeter

OceanGuardTM Ballast Water Management System

F Series Flow Meter F300. User Manual

The RWO Ballast Water Treatment System

Industrial Drum Transfer Pumps

Gilflo flowmeters. for steam, liquids and gases

WBEA Standard Operating Procedure

DOWNSTREAM DEFENDER TESTING USING MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION PROTOCOL UTILIZING OK-110 FEED SAND

Outline. Sampling purpose D-2 standard Ballast water biology Indicative vs detailed analysis Organisms detection methods Viability Minimum dimension

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

Pulverized Coal Extractive Testing Methods Evaluation at the EPRI Coal Flow Loop

BALLAST WATER MANAGEMENT COMPLIANCE 2 DECEMBER 2015 INTERNATIONAL WORKBOAT SHOW 2015 NEW ORLEANS, LA

Flow Meter Calibration

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

WATER POWERED HIGH EXPANSION FOAM GENERATORS

ASME PTC Flow Measurement

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

GUIDELINES FOR TYPE APPROVAL OF SHIP'S BALLAST WATER MANAGEMENT SYSTEMS

Electro-Cleen TM System Ballast Water Treatment System

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT

BALCLOR TM Ballast Water Treatment System. SunRui Corrosion and Fouling Control Company 3 December 2009, Shanghai China

Dewatering solutions that work

Discharge Measurement in Small Hydropower Stations using Acoustic Doppler Current Profiler

Proven Flow Measurement Solutions for the Oil and Gas Industry

Compact flue gas analyser: testo 300 M-I

Transient and Succession-of-Steady-States Pipeline Flow Models

FLUXUS F/G601 and F/G608

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

The Impact Wear Behavior of Large Rocks on Slurry Pump Materials and Equipment.

PORTABLE COATING THICKNESS GAUGE

Proof of Concept Evaluation of Potable Water Generators as Options for Managing Ballast Water for Target Vessels. September 2014

Engineered Systems & Designs TURBIDITY METER

Manage flow and stay in control of your budget

Dewatering solutions that work

DIVA flowmeter. for saturated steam flow measurement

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

Accutube Averaging Pitot Tubes

NEW ON-SITE CALIBRATION TECHNIQUE FOR LARGE FLOW METERS USING LASER DOPPLER VELOCIMETRY

Flow Rate Transmitters/ Flow Switches

Selecting the correct device for measurement control

Ultrasonic Technology for Accurate Flow Measurement of Biogas

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

Ballast water management system

Current Circumstance of Ballast Water Management System

TWIN LASER PARTICLE COUNTER

KRAL Volumeter - OMG Series Universal Flowmeters

ABSTRACT INTRODUCTION

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

REACTION TANKS ADVANCED MEMBRANE FILTRATION

Joint Committee Issue Paper

Triton TR8 Turbidity Analyzer

ProMinent Dulcodes UV Disinfection Systems

Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants

Preliminary Field Evaluation of EPA Method CTM-039 (PM2.5 Stack Sampling Method) Michael D. Buser and Derek P. Whitelock

Long-term Evaluation of Ultrasonic Flowmeters

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

General Discussion of Corrosion Monitoring Considerations in Pipeline Design

COMBIMASS Thermal Gas Flow

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

2008 Beltwide Cotton Conferences, Nashville, Tennessee, January 8-11, 2008

DML-Series. Pelton wheel flow meter

ANALYSIS OF APPLICABILITY OF FLOW AVERAGING PITOT TUBES IN THE AREAS OF FLOW DISTURBANCE

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Flow Meters Demonstration Unit FMDU

ENVIRONMENTAL SAMPLING

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

VIKING BOLTED-LID BASKET-TYPE LINE STRAINERS

California s Marine Invasive Species Program Merging Stakeholder Involvement, Politics. ICAIS September 1, 2010 Maurya B Falkner

Transcription:

Ballast Water Sampling using Proportional Flow Control: Evaluating the Utility of External Ultrasonic Flow Meters in the Shipboard Environment Cameron S. Moser 1, Timothy P. Wier 1, Vanessa Molina 1, Scott C. Riley 1, Stephanie H. Robbins-Wamsley 1, Jonathan F. Grant 2, Matthew R. First 3, and Lisa A. Drake 4 Chemistry Division, Naval Research Laboratory, Washington, DC 23075 1 Excet, Inc., Springfield, VA 22150; USA 2 Battenkill Technologies, Inc., Manchester Center, VT 05255; USA 3 Naval Research Laboratory, Code 6136, Washington, DC 20375; USA 4 Naval Research Laboratory, Code 6136, Key West, FL 33041; USA International Conference on Aquatic Invasive Species 10-14 April 2016 Winnipeg, Manitoba

Outline Background ballast water discharge standards; compliance and representative sampling Technical challenges maintaining proportional sample flow rates Measuring main ballast flow rates Experimental approach validation testing using ultrasonic external flow sensors to measure main ballast flow rate and maintain proportional sample control 2

Ballast Water Sampling In the U.S., sampling and analysis for living organisms in type approval testing will be in accordance with the Environmental Technology Verification Program Protocol (ETV; EPA 2010; USCG 2012) 3

Representative Sampling Per the ETV Protocol - samples must be drawn such that they are representative of the water being sampled (EPA 2010) 4

Representative Sampling The sample port should be sized based on the isokinetic diameter (D ISO ) Where velocity entering the sample port (V ISO ) equals velocity in the line being sampled (V M ) From the ETV Protocol: D ISO is dependent on the main ballast pipe diameter (D m ), sample volumetric flow rate (Q iso ), and main volumetric flow rate (Q m ): D ISO = D m Q iso Q m 5

Isokinetic Sampling Super-Isokinetic V iso > V M Isokinetic V iso = V M Sub-Isokinetic V iso < V M 6

Isokinetic Sampling Current guidance: sample probe should be sub-isokinetic; between 1.5 and 2.0 times the isokinetic diameter OR Velocity entering the sample probe should be between 0.5 and 0.25 times the velocity in the main ballast line Requires sample flow to be controlled proportionally to main ballast flow 7

Proportional Sample Flow Control Constant sample flow velocity vs. varying main ballast flow velocity Proportional sample flow velocity matching with main ballast flow velocity 8 Flow Velocity vs. Time Flow Velocity Time Main Ballast Line Proportional Sample Constant Sample 8

Measuring Main Ballast Flow Rate Many ships do not have flow meters installed Installation is not trivial (e.g., cutting or putting holes in ballast piping) External ultrasonic flow sensors, i.e., flow meters mounted on the exterior of the pipe, can be transported to a ship and are relatively easy to setup and remove Reliability needs to be validated 9

Measuring Main Ballast Flow Rate External ultrasonic flow sensor (transit-time) Speed of sound is affected by the velocity of the fluid Sensor Sensor FLOW Fluid must not contain high concentration of particles or bubbles 10

Experimental Goals 1 Determine the reliability of an external flow meter on a main ballast pipe 2 Evaluate the biological capture efficacy from sample flow controlled proportionally to main ballast flow 11

Ultrasonic Flow Sensor Testing B C D A F E One ultrasonic flow sensor installed at fixed location A per manufacturer s instructions (long undisturbed pipe to ensure fully developed flow) Also directly adjacent to in-line sensors The position of the other ultrasonic flow sensor varied along the piping loop at positions B-F 12

Ultrasonic Flow Sensor Testing Results A F Sample probe 1200 1000 Position F: Directly downstream (< 1 pipe diameter) from sample probe 30 m upstream 10 m downstream *Flow (gpm) 800 600 Steady readings, but between 10 and 17% lower than inline sensors 400 200 0 1 Pump 2 Pumps *1 gpm = 0.227 m 3 h -1 Ultrasonic fixed position Magnetic average (M) Time Ultrasonic variable position Paddlewheel average(p) 13

Ultrasonic Flow Sensor Testing Results B A 1200 1000 Position B: 3 pipe diameters upstream of 90º elbow 30 m upstream 10 m downstream *Flow (gpm) 800 600 Variable position sensor inaccurate and spikes at ~13:18 and 13:38 400 200 0 *1 gpm = 0.227 m 3 h -1 Ultrasonic fixed position Magnetic average (M) Time Ultrasonic variable position Paddlewheel average(p) 14

Biological Validation Experiments Two sampling devices operated simultaneously: One set to sample at a constant flow rate through entire ballast operation The other continuously and automatically adjusted the sample flow rate proportional to the main ballast flow rate (measured using ultrasonic flow sensors) 4 test cycles Biological data for organisms 50 µm were compared between samples collected using each device 15

Biological Validation Experiments 3 m 3 sample volumes collected using proportional and constant flow rates F F F External Ultrasonic Flow Sensor SP Inline sample port 16

Biological Validation Experiments 10 9 8 7 6 *Flow Velocity 5 (ft s -1 ) 4 3 2 1 0 Possible air from activating second pump Time Ballast flow measured using ultrasonic sensors Ballast flow measured using inline magnetic sensors *1 ft s -1 = 0.3048 m h -1 17

Biological Validation Experiments 10 9 8 7 6 *Flow Velocity 5 (ft s -1 ) 4 3 2 1 0 Time Ballast flow measured using ultrasonic sensors Ballast flow measured using inline magnetic sensors Proportional flow velocity (1 min mov. avg.) *1 ft s -1 = 0.3048 m h -1 18

Biological Validation Experiments 10 9 8 7 6 *Flow Velocity 5 (ft s -1 ) 4 3 2 1 0 Time Ballast flow measured using ultrasonic sensors Ballast flow measured using inline magnetic sensors Proportional flow velocity (1 min mov. avg.) Constant flow velocity (1 min mov. avg.) *1 ft s -1 = 0.3048 m h -1 19

Background Technical Conclusions Challenges Experimental Approach Conclusions on Ultrasonic Sensors Measurement accuracy and stability was best when the sensor was set up per the manufacturer s specifications, but still performed adequately otherwise Factory calibrated sensors consistently measured lower flow values than in-line magnetic flow meters or paddle wheels Very sensitive to air in the pipe Had to be installed in a full, non-flowing pipe Errors occurred when installed directly next to each other or along straight section of pipe Possible acoustic signal interference 20

Conclusions Conclusions on Biological Validation No significant difference in living organism concentrations between proportional and constant sample flow Proportional sampling still required to achieve representative sample 21

Conclusions Conclusions Overall To achieve representative sampling on a ship, external ultrasonic flow sensors could possibly provide a workable solution for proportional flow control where in-line flow meters are unavailable Depends heavily on air in the ballast lines 22

Acknowledgements This work was funded under USCG MIPR HSCG23-14-X-MMS010 Thanks to Richard Everett and Regina Bergner for their advice and programmatic support. This work does not represent the official position of the USCG. This work was supported by Diane Lysogorski, Section Head of NRL Code 6136 and Director of the Center for Corrosion Science and Engineering - Key West, Florida 23

References US Coast Guard (2012) Standards for Living Organisms in Ships' Ballast Water Discharged in U.S. Waters (Final Rule). Federal Register 77:17254-17304 US Environmental Protection Agency (2010) Generic protocol for the verification of ballast water treatment technology, version 5.1. Report number EPA/600/R-10/146, United States Environmental Protection Agency Environmental Technology Verification Program, Washington, DC http://www.uscg.mil/hq/cg5/cg522/cg5224/docs/600r10146.pdf 24

Supplemental Slides 25

Ballast Water Discharge Standards Organization and standard US Discharge Standard Living organisms 50 µm in minimum dimension A Living organisms 10 µm and <50 µm in minimum dimension B Toxigenic Vibrio Cholerae C <10 m -3 <10 ml -1 <1 cfu 100 ml -1 Escherichia Coli <250 cfu 100 ml -1 Intestinal Enterococci <100 cfu 100 ml -1 IMO Regulation D-2 Ballast Water Performance Standard <10 m -3 <10 ml -1 <1 cfu 100 ml -1 or <1 cfu g -1 (wet weight zoopl.) <250 cfu 100 ml -1 <100 cfu 100 ml -1 A Nominally zooplankton. B Nominally protists. C Serotypes O1 and O139. cfu = colony forming unit, IMO = International Maritime Organization, US = United States, and zoopl.= zooplankton. 26

B C D A F E Location USFM 1 Location 1 (Fixed) Distance from anomaly Location USFM 2 Location 2 (Variable) Distance from anomaly Posiiton Notes A ~23D- (186") A 168.5 Both flow meters located next to each other A ~23D- (186") B 3D+ Difficulty getting signal, had to prime pipe A ~23D- (186") C 3D- A ~23D- (186") D 5D- A ~23D- (186") E ~11D- (86") bottom of pipe A ~23D- (186") F ~1D- directly downstream of sample port (~12Dfrom elbow) 27

Biological Validation Experiments Concentrated sample collected from constant and proportional flows are rinsed into separate flasks A stainless steel housing with a filter bag Samples are transport to the biology laboratory for analysis 28

Biological Validation Experiments Each 50 µm sample was mixed, subsampled, and diluted for a total of 5 subsamples for each skid Live/Dead Counts using Bogorov Chambers 29

External Flow Meter Selection Transit-time flow meter chosen, since Doppler flow meters are restricted to fluids containing particulates Siemens SITRANS FUP1010 Pipe sizes between Diameter Nominal (DN) 6 to DN 9140 (0.25" to 360") Accuracy ±0.5 to 2.0% 4-20 milliamp (ma) output Weatherproof Portable and battery- powered ~$9000 https://www.google.com/url?sa=i&rct=j&q=&esrc=s&source=images&cd=&cad=rja&uact=8&ved=0cacqjrxqfqotclcn492opmccfyo2hgodfk4mdq&url=http%3a%2f%2fw3.siemens.com%2fmcms%2fsensor-systems%2fen%2fprocess-instrumentation%2fflow-measurement%2fultrasonic-flow-meter%2fclamp-on-flow%2fconfigurable-systems%2fpages%2fsitransfue1010-energy.aspx&ei=gojlvbdehiptepacsagh&bvm=bv.99804247,d.dmo&psig=afqjcnhmp52yuc1w-fujrooz7vf3ql-uqg&ust=1439488507853593 30