Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

Similar documents
XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

ARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD:

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

PD662 Loop-Powered Meter Instruction Manual

Red Eye Multiphase Water-Cut Meter

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

HINDUSTAN PETROLEUM CORPORATION LIMITED ADDL. TANKAGE PROJECT- MUNDRA TERMINAL

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Volume Flow and Gas Flow Measuring Devices

European MID Directive for Custody Transfer Measuring Instruments Proven, certified technology for Fiscal & Custody transfer applications

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Products Solutions Services. Successful Tank Farm and Terminal Management It starts with safety, efficiency and simplicity

Liquid level switch BW 17

OPTIMASS 7400 Technical Datasheet

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

Gilflo flowmeters. for steam, liquids and gases

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

GENERAL PROVISIONS: Furnish and install one steel deck platform motor truck scale and associated electronic controls.

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

Digital E3 Modulevel Liquid Level Displacer Transmitter

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

DIVA flowmeter. for saturated steam flow measurement

LIQUID CONTROLS. Terminal and Bulk Plant Metering Applications. Application Brochure:

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Flow Measurement SITRANS F M

VERIS Accelabar. Superior Flow Measurement Accuracy

The following document can be provided to an Engineer, Contractor, or Owner to allow them to

Tank Scale Service Checklist

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

Using the PPM2 Portable Trace Moisture Transmitter

.2 The scales and automated system for each of the three (3) scales shall be supplied from a single manufacturer.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

MATERIAL AND EQUIPMENT STANDARD FOR PIG LAUNCHING AND RECEIVING TRAPS

LEASE AUTOMATIC CUSTODY TRANSFER UNITS (LACT UNITS)

BioTector System-C. Online TOC Analyzer for Clean Water Applications

Vortex Mass Flowmeter

AT9000 Advanced Transmitter Absolute Pressure Transmitters

Results of the IEC Functional Safety Assessment

F Series Flow Meter F300. User Manual

TABLE OF CONTENT

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

TECHNICAL SPECIFICATIONS for 100Ci Ir-192 source projector(exposure device /Camera )

SARDAR VALLABHBHAI NATIONAL INSTITUTE OF TECHNOLOGY,SURAT

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

TECHNICAL SPECIFICATION FOR CLAMPS & CONNECTORS FOR 66/132/220/400 KV SUB-STATION

Model BF 720 Incubators Avantgarde.Line with forced convection

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

TECHNICAL SPECIFICATIONS DIVISION 16 - ELECTRICAL SECTION DETAIL SPECIFICATIONS FOR ELECTRICAL INSTALLATION

SPECIFICATION SHEET JUNCTION BOXES

PRODUCT CONFORMITY CERTIFICATE

TVA Target Variable Area Flowmeter

MJK Automation YOUR PARTNER FOR WATER PROCESSING INSTRUMENTATION BROCHURE EN 1.00 PRODUCT BROCHURE 1401

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

Flanged Water Meters (non-continuous flow)

No.: MTL/PUR/13/06/Pt.XVI/(J)/10 DATE :

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Smart Displacement type Level Transmitter

The Ton-Tel Weighbridge

SST-II HYDRAULIC BI-FOLD SPECIFICATIONS

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

Addy Baksteen June 20, 2016 HONEYWELL'S VISION ON THE FUTURE OF MEASUREMENT

Mechatronic pressure measurement. Applications. Special features. Description

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

SIWAREX FTC-B Weighing Module for Belt Scales Set-up of SIWAREX FTC with SIWATOOL FTC_B

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps

SPECIFICATION SHEET. Measurement method. Measurement range switching. cell. 1 /2 inch dia ppm. cylinder cell. 1 /4 inch dia.

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Choosing The Correct Flow Meters For Hydraulic Fracturing

GENERAL PROVISIONS: Furnish and install one steel platform motor truck scale and associated electronic controls.

Sensor unit MC2 for toxic gases and oxygen with analog output

Electromagnetic flowmeter ProcessMaster FEP300/500 The first choice for the process industry

4690 Series Turbidity systems. Accurate, reliable turbidity measurement

High Capacity Weigh Modules

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

Technical System Catalogue Modular PDU (PSM)

Thermocouple for Flue Gas Temperature Measurements,

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

Industrial Flowmeters

Instruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives.

METERING TO DATA MANAGEMENT

Reduce costs, improve well testing, and maximize production

For Safe and Delicious Water

ASSAM GAS COMPANY LIMITED ( A GOVT OF ASSAM UNDERTAKING) P.O. DULIAJAN, DIST. DIBRUGARH PIN , ASSAM, INDIA

Transcription:

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations Note: These are general specifications and guidelines for Mass Flow Meters for Petroleum Oil Installations. The scope of this tender is limited to the following components of the system; 1. Supply of Mass Flow Meters of 4, 6 & 8 sizes 2. Annual Calibration of Meters 3. Annual Maintenance contract 4. Supervision of Installation & Commissioning Specifications/provisions relevant to the above scope of supply shall be applicable for this tender. Site execution works including any cabling, installation, control system, software, integration with existing terminal automation systems are not part of the scope of this tender.

1. Application SPECIFICATION OF CORIOLIS MASS FLOW METER FOR LIQUID HYDROCARBONS To measure the mass flow rate of MS/HSD/SKO during custody transfers in pipelines. 2. Measurement Standard API, Manual of Petroleum Measurement Standard s Chapter 5 Metering Section 6 Measurement of Liquid Hydrocarbons by Coriolis Meters. 3. Operating conditions 3.1 Flow Rate Operating: Minimum 100 KL/HR ; Maximum : 2000 KL/HR 3.2 Pressure Operating: Min :1 kg/cm2; Max : 6 kg/cm2 for 150# 3.3 Operating Temperature:5 0 C (Min); 50 0 C (Max) 3.4 Density /Viscocity/Other parameters : Please refer BIS Standards IS-1459 for SKO; IS-1460 for HSD & IS-2796 for MS 3.5 Allowable Pressure drop : 0.5 kg/cm2 (max) of the maximum flow 3.6 Corrosive Components:2500 ppm (Max) of sulphur and substantial amount of caustic is present in Hydrocarbon. 4. Process connections 3 to 10 with flanged ends 150/300/600# as per ANSI B 16.5 5. Installation Location The proposed mass flow meter shall be installed on horizontal pipe line section which is at 0.3M-1.2M elevation above ground, supported on concrete sleepers/ Structural Supports and the mass flow meter construction/design shall comply with the installation location aforesaid. The Bidder shall provide a drawing of the recommended installation arrangement with the piping modified proposed, along with the bid. 6. Materials of construction 6.1 Coriolis Mass flow sensor (Wetted Parts): The wetted parts shall be SS316 / SS 904 L for all products. The sensor design shall consist of two U tubes of appropriate shape and shall be continuously excited at their resonant frequency. 6.2 Housing of the Flow Transmitter: Epoxy coated die-cast Aluminium 7.0. Accuracy of the Mass Flow measurement and factory calibration: 7.1 Maximum allowable error: ± 0.1 % of the reading 7.2 Repeatability& Linearity: ± 0.05% of the reading 7.3 Density accuracy : ± 0.0005 gm/cc

7.4 Density repeatability : ± 0.0002 gm/cc or better 7.5 Factory Calibration: The Coriolis Mass Flow meter shall be calibrated at a calibration rig which is accredited to ISO/IEC 17025. The calibration method shall be based on gravimetric measurement with weighing container. 7.6 No of calibration/test points: 5 7.7 ISO/IEC 17025 accreditation: A copy of the ISO/IEC 17025 accreditation certificate of the calibration facility/calibration rig, shall be submitted along with the technical bid. Note : i. In case Strainer and Air eliminator are required to provide the accuracy mentioned, above the vendor shall provide the same within the quoted rate. ii. Successful vendor to satisfy himself with respect to external vibrations that may affect the accuracy of the mass flow meter before installation.suitable modifications required in piping supports may be suggested before installation so that accuracy of the meter is not affected. 8. Flow Transmitter/Display Unit 8.1 Type : Integrally mounted on the sensor unit 8.2 Display : Backlit LCD for clear visibility during poor illumination levels 8.3 Process variables available on display 8.3.1 Mass flow in engineering Units: 8.3.2 Volumetric Flow in engineering units: 8.3.3 Density: 8.3.4 Process Temperature: 8.4 Reset counter and cumulative totalizer :The Flow Transmitter/Display Unit shall be equipped with 8 Digits Cumulative Totalizer & 5 Digit Reset Counter with programmable decimal point. The reset counters shall keep track of total amount of mass transferred during each product transfer and can be viewed, started, stopped and reset through front panel controls. The cumulative totalizer shall track the same mass as reset counter but reset facility shall not be allowed. 8.5 Self Diagnostic functions The Flow Transmitter/Display Unit shall be capable of performing selfdiagnostic tests on hardware and displaying diagnostic messages and alarm features on indicator. 8.6 Output signals

8.6.1 The Flow Transmitter/Display unit shall have RS 485 output over MODBUS RTU and shall also be capable of generating active 4 20 ma dc current signal which is linearly proportional to the mass flow rate for remote indication. 8.6.2 The Flow Transmitter/Display unit shall be capable of generally active pulse output which can be configured to indicate the mass transferred. Number of pulses generated for a unit mass transferred, shall be user configurable. 8.7 Communication functionality: The mass flow meter could be configured, calibrated remotely using MODBUS output / HART calibrator. All the measured readings shall be transmitted over MODBUS output. Bidder shall assist the client s TAS vendor in establishing the communication with automation system. 8.8 Surge Protection: The Mass flow Meter Hardware shall be protected against surges, transients induced either by switching of heavy electrical loads or lightning. Compatible surge protectors recommended by OEM for signal and power supply, with necessary mounting accessories shall be provided. The surge protector shall be designed and tested as per the requirements of BS EN 62305 or IEEE C62.41. 8.9 Ingress Protection Class: Ingress Protection Class as per IP65 as per IEC/EN60529 8.10 Electrical Connection: ½ 14 NPT or M20 8.11 Coriolis mass flow meter shall be of in-line mounting design with flow direction clearly marked on the flow tube to ensure proper installation 8.12 Coriolis Flow meter shall be provided with internal temperature sensor for fluid temperature compensation 8.13 The flow meter shall be capable of computing field density and shall incorporate temperature sensor for fluid temperature measurement 8.14 The transmitter and sensor unit are separate as specified in data sheets. The interconnecting cable and suitable cable glands with PVC Shrouds shall be supplied by the bidder 8.15 Meter electronics shall be provided with security locking password to ensure restricted access to configuration & modification in settings 9.0 EMC Compliance The mass flow shall comply with generic immunity standards EN 50081, EN 50082 and EN 55011 for emission. 10.0 Hazardous Area Certification: Shall have approval from ATEX 11 2G Exd 11AT6 and CCOE for use in hazardous area, Zone1 11.0 Power supply available at the installation:240v, 50 Hz 12.0 Environmental Conditions 12.1 Ambient temperature:5 0 C 50 0 C

12.2 Relative Humidity: 5% - 9% non-condensing 13.0 Quality Standard/Accredited Calibration Facility The Mass Flow Meter shall be factory calibrated at a calibration rig which is accredited by the national metrology authority of the manufacturing country in accordance with ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories. A copy of the ISO/IEC 17025 accreditation certificate shall be submitted along with the bid. Mass flow meters shall be flow calibrated with gravimetric method using water and shall have calibration certificate duly signed by weights and measures authority such as NMI, PTB or other reputed National standard flow Laboratory. Flow meter shall have international & national legal metrology approvals for custody transfer application. Calibration mechanism of the mass flow meters shall be sealed by weights and measures department to prevent tempering by unauthorised personnel. Calibration and sealing through weights and measures department at the time of supply and for warranty period, AMC period shall be included in the Bidder s scope. Suitable provision shall be in-built with transmitter for putting the W&M seal. 14.0 Custody Transfer Approvals - 14.1 The MFM shall have custody transfer approvals ( for Mass Flow measurement & volumetric Flow Measurement) as per OIML R117 from OIML approved Laboratories ( e.g. NMI /PTB etc.). 14.2 The MFM shall also have custody transfer approvals from W&M, India. for Mass Flow measurement & volumetric Flow Measurement 14.3 Each MFM shall be calibrated at FCRI,Palghat & sealed/ stamped by W&M Dept, India,for custody transfer applications as part of original order. 14.4 In case approval from State W&M is required for the location in which the mass flow meter would be installed then the vendor shall have to arrange for same. 14.5 The supplied mass flow meter shall have facility for W&M hardware lock and software lock. 15.0 Warranty The mass flow meter shall be a proven design and availability of spares shall be guaranteed for at least 10 years period. The supplier shall guarantee that the design engineering and equipment supplied shall be free from defects and shall confirm to specification. All defective material shall be replaced free of charge within 24 months from the date of commissioning or 30 months from the date of delivery of last consignment whichever is earlier. 16.0 Documentation and operation and maintenance manuals 16.1 Product catalogues containing technical specification, options, features and functions, dimensional drawings, installation arrangements with proposed piping modifications, ISO/IEC 17025 accredited certificate for the calibration rig and hazardous area certification from CCOE of the quoted model shall be submitted with the bid.

16.2 Operation and maintenance manuals containing installation procedures terminal connections, wiring details, spare part lists etc. shall be supplied along with the equipment delivery. 16.3 The mass flow meter shall be calibrated at a calibration facility accredited by the national metrology authority of the manufacturing country in accordance with ISO/IEC 17025, prior to shipment and certified 5 point calibration test report shall be submitted along with equipment delivery. All literature shall be in English Language. 17.0 Calibration facility available: The location of the ISO/IEC 17025 accredited calibration facility at which recalibration services for the mass flow meter could be obtained. The vendor shall separately provide quote for carrying out calibration facility one a year from the above accredited laboratory for a period of 5 years. The rate shall include necessary to and fro freight, cost of calibration in the laboratory. SENSOR Sensor Vendor to specify Service MS/HSD/SKO Volumetric flow range Operating flow Maximum pressure Process temperature Density of fluid (Range) Viscosity Line size Process connection RF Flanged as per ANSI B 16.5 Accuracy +/- 0.1% of reading or better for mass flow Repeatability/Linearity +/- 0.05% of measured value or better Material of construction of tube SS316 or better MOC of flanges, reducer, SS 304 or better expander, nuts, bolts etc Transmitter: Power supply Output Local display Zero and span adjustment Operating temperature Safety classification Ingress Protection Transmitter housing 240 V AC @ 50 Hz RS 485 over MODBUS and 4 to 20 ma with HART communication LCD Should be possible with and without HART communicator. 5 Deg C (Min); 50 Deg. C (max) Instruments shall be suitable for working in n Zone 1, Group 2A type hazardous area as per IEC 79-11 (1991) classification. IP65 Should be painted with anti-corrosive epoxy paint All standard accessories such as flanges, reducer, expander, nuts, bolts and any other accessory not mentioned but required for completeness should be supplied along with the instrument. Approved Makes: Endress& Hauser, Siemens, Forbes Marshall, Honeywell, ABB, Emerson, Rheonic,

Henrich, Krohne or approved equivalent (See Note 3 below) Notes: 1) Detailed technical catalogue/literature should be sent along with the offer. 2) All test/calibration certificates along with instruction manual / Operation manual in English should be provided at the time of supply. 3) A make shall be considered as approved only if Custody transfer Approval as per Clause 14 are available. 4) SS tag plate with tag number, CCOE/PESO certificate no.,process parameters and other relevant information shall be fixed on the instrument.