SPE-DEX 4790 Automated Extraction System. A Fully Automated Sample Preparation System. votre distributeur

Similar documents
CLEAN WATER Clean Water PT Scheme Schedule Clean Water PT Scheme Schedule. Schedule subject to change see ERA s website at

EXPORT SOIL-MATERIAL QUALITY REQUIREMENTS

Automated Solid Phase Extraction of PAH Compounds Utilizing the SPE-DEX 5000

SURPLUS SOIL-MATERIAL REUSE REQUIREMENTS

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

Bottled Water Report

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

2017 Bottled Water Report

Application Note: Multi-Residue Pesticides in Fruit and Vegetables (9/16/08)

Certificate of Accreditation

Co-ordination of an organochlorine pesticides in drinking water proficiency testing scheme in South(ern) Africa

Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks

PROFICIENCY TESTING PROGRAM. June 2013

Torch Combustion TOC Analyzer

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

SEDIMENT SAMPLING AND ANALYSIS REPORT

PRETREATMENT PROGRAM INDUSTRIAL WASTEWATER DISCHARGE PERMIT APPLICATION. La Porte

Appendix A. Drinking Water Standards and Guidelines for Pesticides Sampled in Oregon Ground and Surface Water

PROFICIENCY TESTING PROGRAM. June 2014

CITY OF DALLAS PERMIT TO DISCHARGE TO THE SANITARY SEWER APPLICATION FORM Note: Please read and complete all the sections of this application.

HUNTINGTON SANITARY BOARD

WATER QUALITY REPORT INTRODUCTION

Salt Lake City Water Reclamation Plant Industrial Pretreatment Program Industrial Waste Survey Long Form

~ '2::5 - SUZANNE BLANCAFLOR, MS, MPH CHIEF, ENVIRONMENTAL HEAL TH SECTION D,!>~) STATE OF CONNECTICUT. Eurofins Lancaster Labs Environmental, LLC

CALA Directory of Laboratories

Laboratories Certified to Perform Chemical Analyses on Public Drinking Water

NovaWAVE. A new category of Automated Microwave Digestion

Part 1: Property Ownership, Property Information and Owner s Certifications

Lower Mystic Fish Advisory Project Presentation to the Mystic River Watershed Initiative Science Forum May 5 th, 2017 Patrick Herron Rafael Mares

Inorganic Chemicals (IOCs)

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

West Warwick Regional

Appendices. Appendix H Quality Assurance Project Plan

PART 433 METAL FINISHING POINT SOURCE CATEGORY

STATE OF CONNECTICUT

2016 Bottled Water Quality Report Spring Water

California Bottled Water Report

NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) APPLICATION FOR INDIVIDUAL PERMIT TO DISCHARGE INDUSTRIAL WASTEWATER

Phthalates : Environmental Health Issues & Reduction Strategies. Kevin Masterson, Oregon DEQ ACWA Water Quality Committee April 7, 2016

Mosaic Fertilizer, L.L.C. Hopewell Mine

InviMag Forensic Kit / KingFisher 96 for extractions of genomic DNA from forensic samples using KingFisher 96 instrument (Thermo Electron)

MEMORANDUM. Rod Miller, WQD, Laboratory Director

Executive Summary. This sample meets all the EPA, FDA 21 CFR Sec (b), and IBWA Standards of Quality.

Extraction of POPs from Environmental Samples using Accelerated Solvent Extraction (ASE )

Wastewater Discharge Permit Application

310 CMR: DEPARTMENT OF ENVIRONMENTAL PROTECTION

Determination of Persistent Organic Pollutants (POPs) in Fish

Interlaboratory Proficiency Testing 2014 QC Programme

CHROMATOGRAPHY/MASS SPECTROMETRY

Practical Quantitation Limitation Guidance Document

Extraction of Phthalates from Solid and Liquid Matrices

P02-04 CALA Program Description - PT Catalogue Revision 1.19 October,

Criteria for Surface Water Quality Classifications. Class II: Shellfish Propagation or Harvesting. Predominantly Fresh Waters

PowerPrep TM. Automated Multi Column Sample Cleanup for Trace Analysis

2013 Water Analysis Report

LabChip 90 System with DataViewer Software

GERBER PURE Water. Primary Inorganics Antimony

Automated Mercury/Non-mercury Intrusion Porosimeter AMP-60K-A-1

Direct Water purification system Pure & ultrapure water directly from tap water

Oregon. Environmental Laboratory Accreditation Program

National Partnership for Environmental Priorities. David Langston EPA Region 4 RCRA Programs Branch

SpeedExtractor E-916 / E-914 Technical data sheet

1080 Total Organic Carbon Analyzer

IC-D3160 Ion Chromatograph

Sample Clean-Up with Immunoaffinity Columns and Gel Permeation Chromatography: A Product Overview

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Water Quality Report. Covering the period of January 1, 2005 to December 31, Kaua i Department of Water Wailua-Kapa a Water System

Presented at the SafeSpur Forum 18 November 2009, Chorley

MILESTONE MILESTONE ETHOS X. Advanced Microwave Extraction System for Environmental Applications

PAHs in Surface Water by PDA and Fluorescence Detection

Updated Ambient Concentrations of Toxic Chemicals in San Francisco Bay Sediments

SYSTEM INTEGRATION AND AUTOMATION

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

For more information about Volvic Natural Spring Water, call or write to us at Volvic Consumer Care, PO Box 1625, Horsham, PA 19044

January 17, 2017 Page 1 of 1. Desert Springs Bottled Water PO BOX 273 Echo, OR 97826

C191-E018A. Analytical Network Data System Compliant with ER/ES Regulations Progress Configuration of LabSolutions System.

Environmental Management Chapter ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT WATER DIVISION - WATER SUPPLY PROGRAM ADMINISTRATIVE CODE

Name of Process: Vendor: Applicable Pesticides and related POPs wastes: Technology description:

sample management automated modular microtube storage and handling natural innovators

TECHNICAL MEMORANDUM

Tissue Microarray Catalog

APPENDIX L CAP MATERIAL SPECIFICATIONS

Gas Generators. Parker Balston

Chloride/Sulfate Analyzer

ADDENDUM #004. Laboratory Analysis on Water Treatment Plants, Wastewater Treatment Plants, and Groundwater Wells

Fpollutant-free zero air for analytical

SIMATIC Sensors. RFID Systems SIMATIC RF. for optimization of material flow and logistics. Brochure September Answers for industry.

PROFICIENCY TESTING PROGRAMS SOILS & INPUTS

THE EU-LIST OF PRIORITY SUBSTANCES A NEW STRATEGY AGAINST WATER POLLUTION

MILESTONE MILESTONE ETHOS X. Advanced Microwave Extraction System for Environmental Applications

Milli-Q Reference Water Purification System

HiSeqTM 2000 Sequencing System

Fusion UV/Persulfate TOC Analyzer

Evian Natural Spring Water - Annual Water Quality Report

Al. Mickiewicza 30, Krakow, A-0 pavilion tel. (12) , Secretariat KHGI (12) , fax (012) ELABORAT # 8 page 1/pages 4

FULLY AUTOMATED ENZYME IMMUNOASSAY ANALYZER AUTOMATED IMMUNOASSAY ANALYZER. Advanced Immunoassay Testing TOSOH BIOSCIENCE

ELISA STAR Standard Solutions

Advanced Immunoassay Testing

...because safety matters. Admiralty Digital Publications

Fusion UV/Persulfate TOC Analyzer

Transcription:

SPE-DEX 4790 Automated Extraction System A Fully Automated Sample Preparation System votre distributeur

FULLY AUTOMATED SPE-DEX 4790 The Horizon Technology SPE-DEX 4790 Automated Extraction System is a programmable, multipurpose, automated SPE system, capable of processing aqueous samples directly from their Horizon Technology understands the challenges today s laboratories face. The automated extraction systems we develop and manufacture, help laboratory managers meet their business objectives. original containers. Once initiated, each SPE- DEX 4790 Automated Extraction System sequentially delivers all the necessary solvents to precondition the sorbent material within the SPE disk, then passes the water sample through the disk and, after a preset air-dry time, extracts the sorbed analytes from the disk into a collection vessel using the required amounts of solvents. The SPE-DEX 4790 Automated Extraction System uses Solid Phase Extraction (SPE) technology replacing the old, labor-intensive liquid-liquid extraction (LLE) technique. The SPE procedure reduces up to 90 percent of solvent consumption when compared with the conventional methods, exhibiting a significant reduction in purchase and disposal costs of chlorinated solvents such as methylene chloride.

SPE-DEX 4790 Automated Extraction System - Hardware g Processes the sample directly from the original sample bottle. g Delivers all necessary solvents. g Thoroughly rinses the sample bottle. g Extracts the analyte from the SPE disk into a collection vessel. g Purges the extractor in preparation for the next sample. Table 1: % Recovery of EPA 525.2 Analytes Abundance TIC: LFB1.D 5000000 4500000 4000000 3500000 3000000 2500000 2000000 1500000 1000000 500000 Analyte % Recovery Hexachlorocyclopentadiene 102 Dimethylphthalate 93 Acenaphthylene 99 Diethylphthalate 120 Fluorene 108 Propachlor 113 Trifluralin 120 Hexachlorobenzene 105 Atrazine 104 Prometon 81 Simazine 80 gamma-bhc 106 Phenanthrene 97 Anthracene 95 Pentachlorophenol 99 Metribuzin 60 Alachlor 107 Heptachlor 112 Di-n-butylphthalate 106 Bromacil 90 Metalachlor 108 Aldrin 88 Heptachlor Epoxide 109 gamma-chlordane 105 Butachlor 111 alpha-chlordane 106 trans-nonachlor 105 Pyrene 107 Dieldrin 114 Endrin 107 cis-nonachlor 97 Butylbenzylphthalate 111 Di-(2-ethylhexyl) Adipate 117 Methoxychlor 115 Benzo (a) Anthracene 101 Chrysene 103 Di-(2-ethylhexyl) Phthalate* 183 Benzo (b) Fluoranthene 108 Benzo (k) Fluoranthene 99 Benzo (a) Pyrene 96 Indeno (1,2,3-cd) Pyrene 97 Dibenz (a,h) Anthracene 97 Benzo (g,h,i) Perylene 98 Time--> 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00 Table 2: % Recovery of EPA 608 Analytes Response_ Signal: LFB2TEST.D\ ECD2B.CH 7500000 7000000 6500000 6000000 5500000 5000000 4500000 4000000 3500000 3000000 2500000 2000000 1500000 Analyte % Recovery apha-bhc 78 gamma-bhc 65 Heptachlor 86 Aldrin 74 beta-bhc 77 delta-bhc 79 Heptachlor Epoxide 90 Endosulfan I 84 4,4'-DDE 81 Dieldrin 85 Endrin 82 4,4-DDD 83 Endosulfan II 80 4,4'-DDT 89 Endrin Aldehyde 77 Endosulfan Sulfate 82 Methoxychlor 93 Endrin Ketone 87 TCMX (surrogate) 62 DCB (surrogate) 22 Time 1000000 500000 2.00 4.00 6.00 8.00 10.0012.0014.0016.0018.0020.0022.0024.0026.0028.00 PCB 1016 72 PCB 1260 69

DRAMATICALLY LOWER YOUR RE-EXTRACTION RATE Various environmental samples are typically dirty with high particulate matter. The Horizon Accommodates a wide range of sample bottles, volumes, types, and sizes Automatic sample bottle rinse. by utilizing custom cap adapters. Technology SPE-DEX 4790 Automated Extraction System extractors are capable of handling any combination of 47 and 90-mm SPE disks and cartridges. This versatility allows the Fast flow rates through a large sample most economical disk to be used. The sample inlet valve. inlet valve opens to 1/2 diameter, to allow a Pre-programmed EPA methods, with modifying capabilities for method PTFE, sample handling valves and tubing development. variety of sample particulates to pass through the system without difficulty. eliminate internal and crossover contamination. Includes a purge function to prep the extractor between sample runs. included) from which you can configure and Use of 47mm or 90mm SPE disks or SPE cartridges. The Envision Controller connects to a PC (not Dispense up to five (5) pre-wet and three (3) rinse solvents to condition control up to eight (8) individual Horizon Technology SPE-DEX 4790 Extractors. and extract SPE. HPLC grade check valves. The Envision Platform Controller is pre-programmed with the EPA 500 series methods, 600 series methods, and 9000 series methods. Methods can be created or Uses 19/22 taper collection vessels, 40-mL or 60-mL VOA vials Computer not included. modified to handle specific sample matrices.

SOLID PHASE EXTRACTION SYSTEM All sample and solvent pathways, including internal valves and tubing are made of inert materials and PTFE to eliminate internal and crossover contamination. Kalrez valves and PEEK compression fittings provide the system with the chemical resistance and durability required for the multiple solvents used in a wide range of analyte extractions. The SPE-DEX 4790 Automated Extraction System processes the sample directly from the bottle from which it was collected. This eliminates the need for multiple transfer steps. The system also automatically rinses the sample bottle with the extraction solvent, ensuring the highest recovery of the analytes Are high demands placed on your laboratory to increase sample throughput, shorten sample turnaround times, achieve reproducible results, and provide lower detection limits? of interest. Also, the modular design allows the laboratory to start with a single extractor station, and have up to eight (8) extractors on one system, as sample loads increase.

Can you envision more control of your extractor process? Envision Controller for SPE-DEX 4790 Extractions Software g Web-based, user-friendly interface for controlling and monitoring up to eight extractors. g Connects to a standard PC for both configuration and operation. The Horizon Technology Envision Platform is the next generation controller for the SPE- DEX 4790 Extractor System. Built on proven technology, it is the first web-based controller for SPE. The Envision Platform Controller downloads methods to the extractors individually, providing the system the ability to run different EPA methods simultaneously. g User interface allows real-time status viewing. g All solvents identified by name and selected from a library or user-defined solvents list. g Files can be downloaded to a PC, allowing for backup and transfer to subsequent controllers. g Optional PDA and wireless connectivity.

TECHNICAL SPECIFICATIONS Extractor: Dimensions Weight Gas Requirements Vacuum Requirements 7 W x 15 D x 21 H 20 lbs. Nitrogen (Commercial Grade) (60 PSI min) 25 Hg (min) Controller: Maximum Size Weight Power Consumption Input Voltage Input Voltage Frequency Input Voltage Current (Amps) Fuses (2 Required) Fuse Type Electrical Safety International Safety PC Requirements 4 3/8 W x 12 1/2 D x 9 H / 11.11 x 31.75 x 22.86 cm 18 lbs. / 8.17 kg 180 VA 115 VAC or 230 VAC Nominal. Manually selectable 50 60 Hz 1.6 AMP at 115 VAC / 0.8 AMP at 230 VAC 2.5 AMP for 115 VAC / 1.25 AMP for 230 VAC 20 mm UL 61010C laboratory instruments, per acceptable NRTL (TUV) FCC Part 15 CE EN61010 ISO 7000 Graphical Symbols for use on Equipment IEC 60417 - Graphical Symbols for use on Equipment PC with Windows Operating System software; Win 98/ME, Win 2000, Windows XP, Window XP Pro, Vista Intel Pentium III 1.0 GHz minimum or equivalent 512 MB Ram (min) 4 MB free hard disc space (min). CD ROM Drive. Ethernet 10/100 Port (10BaseT) Monitor with 1024 x 768 resolution. Internet Web Browser software; Mozilla Firefox, Netscape, Internet Explorer 6, or Internet Explorer 7