RevealShield SA Penetrations

Similar documents
VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

Henry Blueskin VP160 Air Barrier System Installation Manual

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

How do you install yours?

ELEVATION FOR DETAIL REFERENCE ONLY

BLUESKIN VP160 INSTALLATION GUIDELINES

Tensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7.

Fundamentals of Door Installation START

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

Tech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide

AquaFlash System Installation Guide DS196

Senturion TM III Wall System

2006 Building Code Flashing Changes & Challenges. Builder Breakfast and Luncheon Series Presented by:

FMA_AAMA_WDMA Installation Committee Update FMA Conference May 8, Naples, FL. Jim Katsaros FMA_AAMA_WDMA Installation Committee

Managing Rainwater at the Window-Wall Interface

NEXT GENERATION HIGH PERFORMANCE WALLS

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

Air and Vapor Barrier 3015

SURESILL WATER MANAGEMENT GUIDE

Avoiding Air Barrier Pitfalls When sub-trade activities are not in sync with air barrier requirements, installation can go poorly.

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

ELEVATION FOR DETAIL REFERENCE ONLY

Magnum Board Section Digicon Information Inc. Page 1

LP SmartSide Perfection Shingle

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

Detail Set: Thermax Wall System Masonry

Finestone Stucco Ultra Wall System

for New Construction Applications

DuPont RainVent Batten Installation Guidelines

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

INSTALLATION INSTRUCTIONS

Dow Corning DefendAir 200: Application Guide

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

OSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Majrex. System Guidelines For Air Barrier and Vapor Control Installation

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

STORAGE AND TRANSPORTION

Weatherproofing & Sealing Systems

FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

Armourwall Stucco Systems

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

Integrated Air & Water Barrier Systems

Proper Installation of Insulated Metal Wall Panels

1 Firestone EPDM Roofing Systems

ELEVATION FOR DETAIL REFERENCE ONLY

Senershield -R / Senershield -VB

HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

LUX Specifications. Section S - Preformed Steel Siding

Installation Procedures for the Ultra Air Barrier Wall System

Installation Guidelines for Adhered Concrete Masonry Veneer

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera

Parex USA Stucco Details CSI SECTION

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Finestone Stucco System

Rainscreen Gaps in Exterior Walls

The Original. The Innovator.

DRY SEAL INSTALLATION GUIDE

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

A. Source Limitations: Obtain each type of building insulation through one source.

ENGINEERING EVALUATION

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

Commercial Air Barrier Systems

Water Penetration Resistance - Design and Detailing

RS32 Multi-Section Skylight System under/over seam clip double diverter

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

Building Envelope Moisture Drainage & Ventilation Products from Keene Building Products

RE: Exterior Wall Analysis Use of Gypsum Sheathing Over Dow Thermax Insulation in NFPA 285 Complying Wall Assemblies No. 1JJB05306.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

THERMAL-FLEX COATING ASSEMBLY TO INSULATION BOARD MANUFACTURERS SPECIFICATIONS / SECTION 07240

MID-RISE DESIGN & CONSTRUCTION

BEP Blue Barrier Installation and Application Guide

Synthetic Stucco Without Failures To avoid a lawsuit, build a drainable assembly

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

WALL PROTECTION VIDEOS PROJECT GALLERY INSTALL GUIDES TECH SUPPORT. BenjaminObdyke.com (800)

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Exterior Building Materials & Detailing

KS SERIES - VERTICAL INSTALLATION

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

Exterior Stucco and Siding Installation

Transcription:

Penetrations For Larger Penetrations, use VaproLiqui-Flash tooled at least 2" onto the face and 2" out along all sides of the penetration Apply sufficient Dow 758 Sealant to completely seal fastener penetrations 2" Apply VaproLiqui-Flash to complex penetrations [i.e. structural elements] tooled evenly at least 2" onto the face and at least 2" out along all sides of the penetration [provide backing where needed or over ¼" gap] 2" 2" OK to apply VaproLiqui-Flash to damp substrate 2" Apply and lightly tool Dow 758 Sealant around smaller penetrations up to 1" in Diameter Gasketed Fasteners typically require no additional sealing 06.17.2014 A Vapor permeable, water-resistive, UV stable, air barrier, self-adhered membrane for open joint cladding applications with VaproLiqui-Flash vapor permeable, liquid applied flashing for penetration interfaces. Adhered) creates a complete air barrier membrane system over gypsum or plywood sheathing, concrete, and CMU wall substrates. VaproShield LLC 915 26th Ave. N.W. Suite C5 Gig Harbor, WA 98335 Toll Free: 1.866.731.7663 www.vaproshield.com VaproShield 6/2014

1 RevealFlashing SA Sill Piece applied directly to sheathing + folded 2.75" inside of R.O. *Release paper left on lower 6" to shingle over field membrane 2 RevealFlashing SA Jamb Pieces applied directly to sheathing + folder 2.75" inside of R.O. 3 RevealFlashing SA Sill Pieces applied directly to sheathing + folder 2.75" inside of R.O. 4 VaproLiqui-Flash @ inside rough opening + 1" on face 5 Head flashing (by others) over VaproLiqui-Flash embedded in Dow 758 3 Sheathing in "as new" condition 2 VaproLiqui-Flash + RevealFlashing SA [Self Adhered] Sequencing Exploded View 6 Commercial Window sealant joint + backer rod (by others) 4 5 1 7 RevealShield SA or RevealShield IT field membrane shingled over flashing [sealed w/ Dow 758 for mechanically attached Membranes] 6 2 8 In order to maintain continuity of air barrier system, while allowing for proper drainage at sill, a continuous interior window perimeter sealant joint with backer rod is required. 06.16.2014 VaproLiqui-Flash is a liquid applied, vapor permeable, waterproof, air barrier flashing system component for window and door rough openings. VaproLiqui- Flash is designed to work with RevealFlashing SA and VaproShield field membranes as a complete system. RevealShield SA or RevealShield combined with VaproLiqui-Flash + RevealFlashing help facilitate continuous air barriers behind open joint cladding applications over multiple substrate varieties. VaproShield LLC 915 26th Ave. N.W. Suite C5 Gig Harbor, WA 98335 Toll Free: 1.866.731.7663 www.vaproshield.com VaproShield 6/2014

Substrate Joints RevealShield SA WRB / AB Field Membrane Sheathing in "as new" condition RevealShield SA Open Joint Field Membrane lap onto thru-wall flashing [by others] min. 3" RevealFlashing SA with VaproLiqui-Flash lap 3" min. onto horiz. surface; seal with Dow 758 Sealant and backer rod where prudent RevealShield SA WRB / AB Field Membrane VaproBatten Rain Screen Batten System 10.10.2014

Change in Substrate Substrate in "as new" condition Up to 2" Wide Open Joints Note: Use VaproShims with Horiz. Cladding Attachments RevealShield SA Self-Adhered Open Joint Field Membrane Rain Screen VaproBattens System 05.15.2014

Damage / Defects Dow 758 Sealant tooled or VaproLiqui-Flash tooled @ top edge of reverse lap RevealFlashing SA or RevealShield SA 6" lap around perimeter of damage 10.10.2014

Deflection Joint Backer rod [by others] size determined by building envelope consultant RevealShield SA or RevealFlashing SA 2 layers / min. 3" lap past joint RevealShield SA WRB / AB Open Joint Field Membrane Substrate in "as new" condition mortar joints struck flush 10.10.2014

Expansion or Contraction Joint Substrate in "as new" condition RevealFlashing SA 11.75" with "loop" adhere 3" strip to center of RevealShield SA to back side: adhesive to adhesive RevealShield SA Self-Adhered Open Joint Field Membrane lap onto RevealFlashing SA min. 3" Plan View (NTS) 10.10.2014

Roof to Wall SlopeShield SA lap onto flashing and/or ice & water shield ice & water shield / flashing with butyl, acrylic, or hybrid adhesive Substrate in "as new" condition RevealShield SA WRB / AB Membrane lap min. 3" in shingle fashion at all seams 10.10.2014

Substrate Joints Substrate in "as new" condition Note: Use VaproShims with Horiz. Cladding Attachments Up to 2" Wide Open Joints Joints >⅜" require backing RevealShield SA Self-Adhered Open Joint Field Membrane Rain Screen VaproBattens System 10.10.2014

Wall to Foundation Note: Use VaproShims with Horiz. Cladding Attachments Up to 2" Wide Open Joints RevealShield SA Self-Adhered Open Joint Field Membrane Flashing Membrane RevealFlashing SA or RevealShield SA 3" lap adhere directly to foundation 05.15.2014

Window or Door Rough Opening SHEATHING IN "AS NEW" CONDITION HEAD FLASHING [BY OTHERS] SET IN DOW 758 OVER VAPROLIQUI-FLASH COMMERCIAL OR FLANGED WINDOW W/ BACKING ROD + SEALANT JOINT OR APPROVED TAPE PER WINDOW MFR. [BY OTHERS] VAPROLIQUI-FLASH CONTINUOUS INSIDE ROUGH OPENING + 1" ON FACE NOTE: INNER WINDOW TO WALL INTERFACE TO PROVIDE CONTINUOUS AIR + WATER TIGHT SEALANT JOINT WITH BACKER ROD TO FACILITATE BACK DAM EFFECT AND AIR BARRIER CONTINUITY REVEALSHIELD SA WRB/AB FIELD MEMBRANE SHINGLED UNDER SILL FLASHING PROPERLY SEQUENCED; APPLIED DIRECTLY TO SHEATHING + FOLDED 2.75" INSIDE OF R.O. 05.15.2014

WRB/AB FIELD MEMBRANE SHINGLED OVER HEAD FLASHING SHEATHING IN "AS NEW" CONDITION RevealShield SA Wall to Window Interface HEAD FLASHING [BY OTHERS] SET IN DOW 758 OVER VAPROLIQUI-FLASH COMMERCIAL WINDOW W/ BACKING ROD + SEALANT JOINT [BY OTHERS] VaproLiqui-Flash @ INSIDE ROUGH OPENING + 1" ON FACE RevealFlashing SA PROPERLY SHINGLED; APPLIED DIRECTLY TO SHEATHING + FOLDED 2.75" INSIDE OF R.O. 05.15.2014