Post market Surveillance ISO EU Medical Device Regulation

Similar documents
Post Market Surveillance (including PMCF): common non compliances

Post Market Surveillance

Update on Regulatory Environment- Europe Experience with 2007/47/EC M5 & Discussions on Possible Recast of EU Medical Device Regulations

ASQ Tappan Zee Section Medical Devices, New Regulations and Standards. 26 th September / V. Fischer / Rev. 01

Panel Discussion: European Medical Device Regulations Preparing for the Storm Moderator: Lenita Y. Sims Spears, Senior Quality Consultant/Senior

Ready or Not: The New Medical Device Regulations Are Here!

VIGILANZA E SORVEGLIANZA POST- COMMERCIALIZZAZIONE

MEDICAL DEVICE. Technical file.

Optimize Your Field Safety Corrective Actions Systems

Technical Documentation

Expert Commentary on BS EN ISO 13485:2016, Medical devices Quality management systems Requirements for regulatory purposes

Understanding Clinical Equivalence

Recast Medical Device directives Impacts on materiovigilance

MDR. Device Classification Conformity Assessment Safety & Performance Requirements Technical Documentation

GS1 Ireland Healthcare User Group (HUG) Information Day

Q10 PHARMACEUTICAL QUALITY SYSTEM

GUIDELINES ON MEDICAL DEVICES CLINICAL EVALUATION: A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

Clinical Evaluation and Clinical Investigation update MDR

Implications of the new MDR from a Product Testing and Certification Perspective

International Standards and EU regulation of medical device software an update

CAMD Implementation Taskforce

The challenges of software medical device regulation.

GUIDELINES ON MEDICAL DEVICES

A REVIEW OF MARKET ENTRY REQUIREMENTS FOR RISK MANAGEMENT, WITH SPECIAL EMPHASIS ON FDA AND ISO COMPLIANCE

MEDICAL DEVICE CLINICAL INVESTIGATIONS AND ISO 14155

ISO 22000:2005 Standard INTERNATIONAL STANDARDS REGISTRATIONS

FINAL DOCUMENT. International Medical Device Regulators Forum. Medical Device Regulatory Audit Reports

GUIDELINES ON MEDICAL DEVICES

AAMI Quality Systems White Paper: Comparison of 21 CFR Part 820 to ISO 13485:2016 1

Copyright GCI, LLC Remediation of Legacy Medical Devices

COCIR SUSTAINABLE COMPETENCE IN ADVANCING HEALTHCARE

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Risk Based Approach To Complaint Handling

Conformity Assessment of Own Brand Labelling

Serious Adverse Event Reporting During European Device Clinical Investigations

WHO Prequalification of In Vitro Diagnostics Programme

New EU Regulation on medical devices

AB. OUR ISO CONFORMANCE AUDIT QUESTIONNAIRES 8. ASSESS HOW WELL YOU CONFORM TO ISO S REMEDIAL REQUIREMENTS

Focus on : Notified Bodies PMS PMCF. Rob Higgins Head of Regulatory Affairs

POSITION PAPER Moving from the MDD to the MDR

MEDICAL DEVICES : Guidance document

Guideline on good pharmacovigilance practices (GVP)

Textvergleich. Verglichene Dokumente MEDIA3917.pdf. ICH_Q10_Step4.pdf

Your complimentary Clinica Medtech Intelligence content

National laws. National Competent Authority / Authorities. Orders, ordinances (supervision)

ISO 22000:2005 SYSTEMKARAN ADVISER & INFORMATION CENTER SYSTEM KARAN ADVISER & INFORMATION CENTER FOOD SAFETY MANAGEMENT SYSTEM ISO 22000:2005

GUIDELINES ON MEDICAL DEVICES GUIDE FOR COMPETENT AUTHORITIES IN MAKING AN ASSESSMENT OF CLINICAL INVESTIGATION NOTIFICATION

Table of Contents. Role of Standards in the Assessment of Medical Devices Study Group 1 Final Document GHTF/SG1/N044:2008

FREQUENTLY ASKED QUESTIONS DURING ELECTRO-MEDICAL DEVICE MARKET ACCESS

By: Clay Anselmo COO, DLLS, Founder Reglera and Terry J. Dagnon M.S., Vice President Regulatory Affairs, DLSS

GENERAL AND ORGANISATIONAL REQUIREMENTS

The roadmap to EU-MDR Implementation

Update on the IVDR. Sue Spencer

MDSAP AUDIT PROCESS. A Manufacturer s Perspective. Connie Hoy EVP Regulatory Affairs Cynosure, Inc.

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

Korean Medical Devices Regulations

Current Trends at FDA: Implications for Data Requirements

Due diligence in the European medical devices industry

The New EU IVDR. Overview of the Main Changes & Clinical Data Requirements. Advance Regulatory Consulting Ltd.

Combination Products Part 4 Compliance and Implementation at multi-site Network

Regulations governing the application of medical accelerators

Best Practices: Integration of Risk Management and Corrective and Preventive Action

MedDev and NB-MED Recommendations

PROPOSED DOCUMENT. Global Harmonization Task Force

Correlation Matrix & Change Summary

ISO /TS 29001:2010 SYSTEMKARAN ADVISER & INFORMATION CENTER SYSTEM KARAN ADVISER & INFORMATION CENTER

Guide for Class I Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

SQF 2000 Code. 6th Edition AUGUST A HACCP-Based Supplier Assurance Code for the Food Manufacturing and Distributing Industries

Designation and notification of conformity assessment bodies 1

The Impact of Quality Culture on Quality Risk Management. FDA Perspective on Quality Culture; how it Impacts Risk Management

Medical Device Regulatory Framework 9 SEPTEMBER 2015 FUNDISA CONFERENCE JANE ROGERS

Guideline on good pharmacovigilance practices (GVP)

Medical Device Directive

IVD Regulation 2017/746

The UDI Experience: From a US Perspective

Changes to the Medical Devices Directive and affect on Manufacturers

AEROSPACE STANDARD. Quality Systems - Aerospace - Model for Quality Assurance in Design, Development, Production, Installation and Servicing

The implications of the new EU Medical Device Regulation on Combination Product Packaging

The Risk Management + Design Controls Connection: What Device Makers Need to Know

Guide for Ethics Committees on Clinical Investigation of Medical Devices

The implications of the new EU Medical Device Regulation on Combination Product Packaging

Clinical evaluation report,

IECQ PUBLICATION QC IEC Quality Assessment System for Electronic Components (IECQ System)

Updated EU Medical Device Regula2ons: What s In, What s Out, and What s Hot?

ISPE Annual Meeting 29 October 1 November 2017 San Diego, CA

SAFETY MANAGEMENT SYSTEMS IMPLEMENTATION EVALUATION GUIDE

Technical Guidance on Clinical Evaluation of Medical Devices

Pharmacovigilance and the Generic Industry

UNANNOUNCED EU MEDICAL DEVICE AUDITS BY NOTIFIED BODIES: IMPACT ON SUPPLIERS

WHO guidelines on quality risk management

Medical Device Purchasing Controls Challenges of Compliance in a World Market June, 2013 OMTEC

FDA Initiatives and Regulatory Trends for Life Sciences. Larry Spears President L. Spears Consulting

MDSAP Me M dical D e D vice S i S ngle Audit Program

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL GUIDELINES ON MEDICAL DEVICES

TERMS AND DEFINITIONS

HOW TO APPLY FOR MEDICAL DEVICE REGISTRATION UNDER MEDICAL DEVICE ACT 2012 (ACT 737)

ISO 9001: 2015 Quality Management System Certification. Awareness Training

Office for Human Subject Protection. University of Rochester

INDUSTRY S VIEW ON THE FUTURE OF IN VITRO DIAGNOSTIC (IVD) LEGISLATION IN EUROPE. May 2013 SPECIAL REPRINT. By Jesús Rueda Rodríguez, EDMA

Transcription:

Post market Surveillance ISO13485 2016 EU Medical Device Regulation Patrick Caines, Ph.D. Baxter Healthcare 15 June 2017

Agenda Post market Regulatory Requirements ISO 13485 2016 Summary of key changes MEDDEV PMCF Risk Management Trend Requirements EU MDR Post market surveillance System alignment & Implementation Surveillance information sources Investigation and Analysis Action System and Outputs Vigilance; Escalation processes CAPA; Field Action Management Reviews & Dissemination Best Practices Questions & Discussion 2

Evolving Regulatory Environment Recognition Limited pre-market clinical data; poor detection / characterization possible complications from widespread use/long-term performance issues. e.g. durability, biocompatibility, Device/device or device/drug interactions, Use error, off-label use, learning curve Inadequate residual risk evaluation and completeness of risk controls In response.. Increased attention & requirements from health authorities and regulators. More pre-marketing data, larger safety databases Increased focus on analyses of outcomes: how is the product used? Risk Management Strategies (REMS/EU-RMP) Increasing role for post-marketing studies 3

ISO Standards for Post market Surveillance ISO 13485:2003 - Medical devices -- Quality management systems -- Requirements for regulatory purposes Procedures to collect information from various sources such as users, service personnel, training personnel, incident reports and customer feedback. Section 8.2 gain experience from the post-production phase, the review of this experience shall form part of the feedback system. ISO 14971:2007 Establish, document and maintain a PMS system to collect information in production and post-production appropriate methods are in place to obtain relevant production and post-production information. The results for this review shall be recorded as the risk management report and included in the risk management file. 4

ISO Standards for Post market Surveillance ISO 14971:2012 - Medical devices Application of risk management to medical devices Methods of obtaining relevant post-production information Established quality management system procedures (for example ISO 13485:2003) ISO 14971:2009, Annex F.7 The risk management plan should include documentation of decisions, based on risk analysis, about what sort of post-market surveillance is appropriate for the device, for example, whether reactive surveillance is adequate or whether proactive studies are needed. Post market surveillance data required: Correction on current products Inputs to future designs Risk Management Plan should also define what type of post-market surveillance is appropriate for the device Reactive surveillance (passive) Proactive studies (Active) Risk Management Plan should also define what type of post-market surveillance is appropriate for the device 5

ISO 13485:2016 Key Changes Focus Area Requirement Risk based approach Requires risk management principles be applied to all aspects of the Quality Management System Regulatory Requirements Increased harmonization and compliance to regulatory requirements Regulatory reporting timelines now in scope Documentation Requirements documented requirements are required to be established, implemented and maintained as appropriate indicates required unless justified otherwise Demonstrate Improvement Metrics are essential to show improvement Analyze data and drive improvement Process Approach Emphasis on meeting requirements, adding value, obtaining performance results/effectiveness and improving process based on objective evidence 6

ISO 13485 (2016) Summary of Key Changes 1 Definitions 3.4: Complaint definition; aligned with FDA definition 3.14: Post market surveillance definition; aligned with global definitions Several new definitions added and many existing definition refined 7

ISO 13485 (2016) Summary of Key Changes 2 Quality Management System (QMS) - General 4.1.1 - New requirement to document the roles of the organization Who is the Manufacturer Who is the Importer Who is the Distributor Who is the Authorized Representative 4.1.2 - New requirement to: o Apply risk based approach to control process o Depict process sequence with linkage Several new definitions added and many existing definition refined 8

ISO 13485 (2016) Summary of Key Changes 3 Management Responsibility Management Review 5.6.1 New requirement to have a documented procedure for Management Review (MR) with documented planned intervals 5.6.2 and 5.6.3 - Management Review inputs and outputs have been expanded 5.2 Customer focus: Top management shall ensure that customer requirements and applicable regulatory requirements are determined and met New Inputs: a) Feedback (Customer, Supplier, Internal employee, may be positive of negative, may be collected or requested) b) Complaints c) Reporting to regulatory authorities Applicable new or revised regulatory requirements are inputs to management review New Output: a) Changes needed to respond to new or revised regulatory requirements 9

ISO 13485 (2016) Summary of Key Changes 4 Customer Related Processes / Communication 7.2.1 Increased requirement for the organization to include customer training needs to ensure specified performance and safe use of the medical device 7.2.2 Prior to organizations commitment to supply product to the customer, the requirement has been expanded to include: o o applicable regulatory requirements are met user training is identified 7.2.3 New requirement for the organization to communicate with regulatory authorities in accordance with applicable regulatory requirements. 10

ISO 13485 (2016) Summary of Key Changes 5 Monitoring and Measurement - Feedback 7.2.3 Customer communication enquiries, feedback, complaints, advisory notices 7.5.4 Analysis of service activities to identify complaints and inputs to the improvement process 8.2.1. New requirement to have a documented procedures to gather feedback data from production and post-production activities. o o o o 8.2.1 Feedback processes (production & post-production) should be documented and serve as inputs to risk management as well as improvement processes 8.2.2 Complaint handling justification for not investigating should be documented; 8.2.3 Reporting to regulatory authorities documented procedures 8.4 Analysis of data including feedback; service reports must be documented The feedback data will serve as a potential input into risk management, product realization or improvement processes. 11

ISO 13485 (2016) Summary of Key Changes 6 Complaint Handling/ Reporting to Regulatory Authorities 8.2.2. Brand new sub clause. The organization must have a documented complaint handling procedure(s) that aligns with regulatory requirements and promotes timely processing. The procedure covers the below: receiving and recording information (Includes exchange with 3rd Parties) evaluating information to determine if the feedback meets the definition of a complaint investigating complaints (Justify if no investigation is required/possible) determining need for regulatory reporting handling of complaint-related product (sample returns) determining need for corrections or corrective actions (Justify if no CA/PA is required) 8.2.3. Brand new sub clause. The organization must have documented procedures for complaint reporting (MDRs, MDVs etc) and advisory notice reporting (Field Action (FA)) that aligns with regulatory requirements. On-time regulatory reporting of complaints (i.e. MDRs, MDVs) and field actions are now in scope. 12

ISO 13485 (2016) Summary of Key Changes 7 Corrective Action/Preventive Action 8.5.2 Expanded requirement for corrective action to ensure: o o corrective action do not adversely affect the ability to meet applicable regulatory requirements or the safety/performance of the medical device corrective actions are taken without undue delay 8.5.3 - Expanded requirement for preventive action to ensure: o preventive action do not adversely affect the ability to meet applicable regulatory requirements or the safety/performance of the medical device Ensure CA/PA actions do not introduce any new Non Conformance (i.e.: Product performance/safety issue or regulatory non-compliance) and document confirmation/justification under Verification and/or Validation (V&V). On-time completion of NCR investigations and corrective actions are in scope of inspection. 13

MEDDEV requirements MDD 93/42 EEC; MEDDEV 2.12-2; Annexes II,IV,V,VI,VII; Annex X 1.1c Manufacturer must institute and keep up to date a systematic procedure to review experience gained in post-production phase; Implement appropriate means to apply any necessary corrective action. Identification and investigation of residual risks associated with the use of medical devices placed on the market. These residual risks should be investigated and assessed in the post-market phase through systematic Post-Market Clinical Follow-up (PMCF) studies. PMCF studies are performed on a device within its intended use/purpose(s) according to the instructions for use. Where PMCF, as part of the post-market surveillance plan for the device, is not deemed necessary, this must be fully justified and documented Manufacturer must have procedures to gather clinical data post-market on all devices, analyze the data, and take action as needed. Clinical evaluation and documentation must be actively updated with data obtained from post-market surveillance. Trend Reporting: when a significant increase in events not normally considered to be INCIDENTs according to section 5.1.3. occurred and for which pre-defined trigger levels are used to determine the threshold for reporting. (Per MEDDEV 2.12-1 rev 6) 14

MEDDEV 2.12-1 rev 8 MEDDEV 2.7-1 rev 4 MEDDEV 2.12-1 revision 8 (released Jan 2013) Includes In vitro fertilization and assisted reproduction technologies (IVF/ART) devices within the scope of the vigilance system and provides clarity in relation to devices that are not intended to act directly on the individual. Provides list of vigilance terms and definitions e.g. abnormal use; use error, harm etc., These were previously found in various documents. Clarified but did not expand reporting requirements for manufacturers e.g. criteria for reporting to the NCA, reporting use error and abnormal use; reporting of signals from trending; periodic summary reporting; field safety corrective actions Provided good overview of the role of the NCA, Notified Bodies, and the European Commission MEDDEV 2.7-1 revision 4 (released Jan 2016) (Clinical Evaluation Reports (CER) Rev 4 reinforces the links between Post Market Surveillance (PMS) and Post Market Clinical Follow-up (PMCF). Appendix 12 highlights the requirement for Notified Bodies to ensure that PMCF is planned and appropriately justified in light of the data retrieved and conclusions documented in the CER. 15

EU Regulatory Requirements vs. Guidance Legally Binding Guidance / Standards Regulations EU MDR - 2016 Directives 1990: (in place) Active implantable medical devices [AIMD] (90/385/EEC)* In-vitro diagnostic medical device [IVDD] (98/79/EC)* Medical device [MDD] (93/43/EEC)* * (As transposed into EU MDR 2016) ISO 13485; ISO 14971 2012; ISO14971 2007 MEDDEV (Vigilance - MEDDEV 2.12-1 rev 7; 2.12-1 rev 8 PMS MEDDEV 2.12-2 EC Reps MEDDEV 2.5/10) The Directives and harmonized standards, form a framework for the manufacturer to develop a comprehensive feedback system to ensure continued safe-use of a device for the manufacturer s intended purpose. National Competent Authorities have instructed Notified Bodies to focus on adequacy of the vigilance process. Expect full implementation of MEDDEV 2.12 rev 8 requirements for post market clinical follow-up, post market plan, and review, trending. Assurance that the legally binding regulations are met. 16

EU Directives Manufacturers must conduct post market surveillance (PMS). PMS requires: 1. Manufacturer institute and maintain an up-to-date systematic procedure to review experience gained from devices in the post-production phase, which include provisions referred to in Annex X (93/42/EEC), or Annex VII (90/385/EEC) 2. Implementation of appropriate means to apply any necessary corrective action. 3. Complemented by harmonized standards: EN ISO 13485, Outline of a quality management system (QMS) structure which compels the need for a feedback system specifically to provide early warning of quality problems and for input into corrective and preventive action processes. EN ISO 14971:2012, Medical devices: Application of risk management to medical devices. Specifies requirements for production and post-production information to be considered as part of the overall risk assessment process throughout the life of the device. 17

Post market MDD 93/42 versus EU MDR MDD 93/42 Annex X Clinical evaluation Clinical investigation MEDDEV 2.7.1 Rev.3 2009 Clinical Evaluation MEDDEV 2.7.4 2010 Clinical Investigations MEDDEV 2.12/2 rev2 2012 PMCF MDR chapter VI Clinical Evaluation (Art. 49) Clinical investigations (Art. 50-60) Annex XIII: Clinical evaluation and post-market clinical follow-up Annex XIV: conducting clinical investigations Literature route broadly accepted for conformity assessment Essential requirements based on clinical evaluation Class III and implantable devices (high risk class): Literature route not acceptable For other risk classes: equivalence may be difficult to demonstrate Enforcement of PMCF all over the life cycle (periodic reports on risk/benefit ratio) 18

EU Medical Device Regulation - Scope Regulatory framework will change from Directives to Regulation Merger of AIMDD and MDD Integration of contents of the GHTF and the MEDDEV guidelines as well as the EN ISO 14155; Reinforcement of ISO, MEDDEV, Risk-based approach CE mark potential changes to product registrations; Legacy products must be remediated. Implementation of EU reference laboratories Better coordinated information exchange between national competent authorities 3-year transition period: Published late 2016; effective 2019-2020 Clinical data and Post market Clinical Follow-up (PMCF): Stricter assessments: periodic reports to the member states Stricter requirements for clinical evidence Implementation of the UDI Expansion of EUDAMED Electronic Database on Vigilance; Centralized system for safety reporting and vigilance; Clinical Investigations. Centralized submission process with multi-centric clinical investigations More accountability for Notified Bodies (NB) Certifying devices, and in post market follow-up Unannounced inspections by the CA 19

ISO 13485 2016 Implementation Strategy Quality System Alignment Top Level Quality procedures should explicitly map to global regulatory requirements Top Level Quality policy should explicitly include intent to meet all applicable regulatory requirements Global Gap Analysis Complete a gap analysis between top level corporate procedures and the standard. Review and confirm sites and lower level documents comply with and align to corporate procedures. Ensure locally defined requirements are included in your local procedures Global Action Plan to close gaps Understand what global actions are in progress to address gap(s) Determine if local procedures address gap(s) Evaluate timing of resolution compared to your scheduled inspection Inspection / Audit readiness Locally review and prepare your site; understand NB schedule for audits under the new standard. 20

Quality System Alignment Proactive Compliance Establish Process and procedures for: External monitoring of Global regulations Gap Analysis with existing QS Procedures Adjust as needed; Maintain GQR linkages 21

MEDDEV - How to Implement? Establish Post market Surveillance Policy Establish formal requirement for a post market surveillance plans and review. Ensure the Product development process includes establishing Post market Surveillance Plan and a Post market Surveillance Review Post market Surveillance Plan Clearly outline linkages between risk management, design assurance, R&D, clinical, business units, sales and marketing. Clearly define roles and responsibilities Evaluate type of post market surveillance needed Passive (complaints) and/or Active. Passive PMS (Complaints, Literature, Vigilance always required) Active PMS (Customer feedback surveys; Focus groups etc.) Required, but type of activity dependent upon product risk Describe the product specific methods by which information is collected, processed, and evaluated for possible relevance to safety and efficacy. May be implemented as part of the Risk Management Plan; Responsibilities typically fall with the Risk Management Documentation owners, depts. that submit for licensure to NB. Post market Surveillance Review Periodic product reviews and Risk-benefit reanalysis. Include Literature reviews, Post market surveillance outputs, Clinical Evaluations. 22

Post market Surveillance and Risk Management Phase Risk Management Planning Actions Define risk ratings, risk grids, risk acceptance criteria Define risk management deliverables including human factors studies Define plan for post-launch risk management Output: Post market surveillance plan Risk Assessment (Risk Analysis & Risk Evaluation) Identification of known and forseeable hazards in both normal and fault conditions; Estimation of risks for each hazardous situation; literature /standards, human factors Inputs: Monitor production / post production data (Complaint investigations, MDRs, recalls, safety alerts) to re-estimate risk and ensure residual risk remains acceptable. Outputs: Action System, CAPA, Field Action; Management Reviews Risk Control Risk control option analysis & Implementation of risk control measures; Residual Risk assessment; New risks arising from risk control measures On-going assessment of Production / Post Production Information; Monitor need for additional control measures. Post-Market Clinical Follow-up (PMCF) studies; Clinical Evaluations / Periodic Risk Benefit Analyses Outputs: Updates to risk files; triggers for safety alerts; 23 23

Post market Clinical Follow-up Notified Bodies will assess manufacturers PMCF plans, their proposed execution, as well as the assessment of a manufacturer s justifications that a PMCF is not necessary. Considerations for conducting or foregoing PMCF: Does pre-market clinical data reveal any unanswered questions about safety or performance? Did any adverse events occur that warrant further investigation? Was pre-market clinical data improperly generalized? Does the lifespan of your device extend beyond the time frame that pre-market clinical data was collected? Has new information emerged that affects pre-market data? Has the use of the device been extended to populations that were not included in clinical trials? Has the product been altered in any way from the product that was used to gather pre-market clinical data? PMCF studies may include extended follow up of patients involved in premarket studies, new clinical investigations, or a review of relevant retrospective data from patients previously exposed to the device. 24

PMCF How to implement Establish Process and procedures for periodic product reviews and periodic Risk-benefit reanalysis Literature reviews Post market surveillance Clinical Evaluations Other sources of information Cross-functional review Clear decision-making and documentation If determination they are not needed document rationale 25

Trend Reporting Section 4.18 of (MEDDEV 2.12-1 rev 6) - Requirement to file vigilance reports on otherwise not reportable complaints, when trends exceed a pre-set level. Current situation described in MEDDEV guidance (MEDDEV 2.12-1 rev. 7 (Guidelines on a medical devices vigilance system, published in March 2012) includes three situations where trend reporting should be considered: Already reportable INCIDENTs INCIDENTs that are usually exempt from reporting Events that are usually not reportable How to Implement: Requirements not clearly defined; highly variable expectations of the Competent Authorities, with respect to the approach taken by manufacturers Establish thresholds; review process; clearly document rationales for reporting / not reporting MDVs. 26

Example Major NB Non conformance Post Market surveillance does not meet the requirements of the amended MDD the current procedure does not define relative inputs of the post market procedure including inputs to design process, risk management and clinical reviews. Documented evidence that post market surveillance plans are based on the outputs of risk management could not be provided. Requirements Information on Clinical Evaluations and Post Market Surveillance Planning as part of Risk Management; Clearly defined linkages between business units, sales and marketing, design assurance, R&D, clinical, risk management, with clearly defined roles and responsibilities (Post market surveillance Policy) System/process for conducting Post Market Surveillance Reviews (PMSR) (Procedures, templates; examples showing use..) 27

Post market Surveillance QMS Passive Complaints Literature Reviews Vigilance MDR MDV FAR Comprehensive set of Activities: Passive (Reactive) PMS; Always required Proactive (Active) PMS; Required, but level and type of activity dependent upon product risk Active Clinical studies / Registries Customer surveys / Focus Groups Feedback during training PMCF Post market Surveillance Post market Clinical Follow-up 28

Post market Surveillance Components Post market Surveillance and Action System Surveillance (Information Input) Investigation & Analysis Action Communication Complaints Servicing Literature Reviews Customer Feedback Surveys Focus Groups Post market clinical studies; OUS events if same / similar product is marketed or manufactured in US Integrated data systems Failure Investigations Returned products Internal testing Medical review Risk Management MDR filing decisions Vigilance (MDV) analysis Field Alert Reports (FAR) BPDR CAPA Process Design Labeling Training Correction / removal All stakeholders Management Internal businesses & plants R&D; Risk Mgt. US / OUS Regulatory Agencies Hospitals, Physicians, Patients Suppliers Distributors Goal of PMS system is to take appropriate action to protect public safety and improve product performance 29

Surveillance Information Sources Consider how is the company structured Organizational Alignment Multiple manufacturing sites, businesses, divisions Complaint processing site vs. investigation site Complaint Record Accessibility Complaints Not maintained at Manufacturing Site Call centers Who are the designated complaint handling units Reporting Central team; Regulatory Affairs; Local Units Electronic systems and flow of information. Consider: Service Systems; Complaint Handling Systems; Electronic vs. paper Translations and Time zones Record availability 30

Surveillance Information Training Customers, Sales Force, Field Service, Affiliates, Distributors; 3 rd parties Are roles, responsibilities, accountabilities for reporting complaints and adverse events in a timely fashion, undertaking the necessary follow-up; when req d; parts returns etc. clearly understood and documented by all parties? Training Do all employees know where and how to report Complaints and Adverse events? Complaint and Adverse event (pharmacovigilance) staff trained on the products, use, safety signals, and the regulation. Document complaints and adverse events so that they are easy to follow and understand internal and external stakeholders Training records for company employees service; sales force; documenting they have been appropriately trained in complaint handling and adverse events. Quality agreements between Manufacturing sites. Pharmacovigilance Unit, Complaint handling unit. Quality agreements with Affiliates and Distributors. 31

Investigation & Analysis Must be both Patient- and Product-Centric Patient Related Questions What was the patient s condition prior, during, and after the use of the device or drug? Did or would the patient require medical or surgical intervention related to an issue associated with the use of the device? What medication did the patient require prior to and subsequent to the adverse event? Did the patient require return visits to a physician or health care provider to monitor healing after the adverse event? Product-Related Questions How and why was Company made aware of this event? What other experience has Company learned about the use of this device in the same or similar circumstances? What have past Company investigations revealed about the use of this device? What is the severity and frequency of reported complaints associated with this device? Has there been any change to the manufacturing of, or materials used in the manufacturing of, the device, even ones meant to improve quality? 32

Action System & Outputs Regulatory Reporting Manufacturing Device Reports (5-30 day time frame) Vigilance Reports (10-30 day time frame) Field Alert Reports (3-day time frame) Escalation: Corrective & Preventive Action (CAPA) Process Design Labeling Training Non-conformances Risk Management Correction / removal Field actions / Field Safety Corrective Actions (FSCA) Recalls Safety notices 33

Vigilance Reporting Challenges Challenges: Differing global regulatory requirements Timeframes for reporting differ by country and / or region Implementing MDD / EU / MEDDEV Requirements Field actions - Reliance on Affiliates, Distributors, 3 rd parties Maintaining accurate install base and product listing Solutions: Be aware of current and emerging regulations Use country-specific Decision trees and standard forms documenting reporting decision Establish process for updating decision matrices and electronic systems Clarify authority to make reportabilty decisions at local / country level and ensure local / country personnel are adequately trained Local language and provisions for translation Ensure consistent record content 34

Dissemination & Management Reviews Timely & Accurate information Exchange Internal & External stakeholders: US & Outside US Regulatory Agencies Hospitals, Physicians, Patients Site, Business Unit, Regional and Exec Management Reviews Businesses; Manufacturing plants; R&D; Risk Mgt. Local, Regional & Corporate quality boards Suppliers, Distributors, other 3 rd parties Typical information disseminated / discussed: Serious AE; Reportable events; Product Trends System performance efficiency and effectiveness metrics Relevant CAPAs; Projects/initiatives Investigations Status & Aging Industry trends and new/changing regulations User feedback Procedural changes/improvements 35

Best Practices - Effective Post market Surveillance 1. Establish and Maintain Strong Linkage with Quality Systems Risk Management Ensure strong signaling and feedback systems. Quality Culture Clearly outline linkages between business units, sales and marketing, design assurance, R&D, clinical, risk management, manufacturing, with clearly defined roles and responsibilities Leverage Risk Management information to aid in assessment and making reporting decisions. Establish formal requirement for a post market surveillance plans and review (Post market surveillance policy). Clearly outline passive (reactive) and active post market surveillance; sources; mechanisms for flow-down into the post market surveillance system. 36

Best Practices - Effective Post market Surveillance 2. Develop Tools to facilitate collection and documentation of customer feedback & complaint information. Customer feedback Literature; focus groups, training sessions, social media; Post market clinical studies; registries (condition of approval and marketing studies. Establish procedures and train all company employees and agents to recognize and report complaints and adverse events within a defined timeframe: Customers to call centers; Customers to Sales Reps; Distributors; 3rd parties; Service Product specific complaint questionnaires; electronic links on company homepage. Take proactive steps to maximize likelihood of sample and device return. Communicate to customers importance of device return. Provide clear instructions and processes to facilitate return. Balance Patient-centric vs. Product-centric information collection: Use Product / therapy-specific Complaint Notification Forms What happened? When did it happen? Was the patient / user injured? Severity of Injury? Follow-up to determine patient outcome Device / Lot / Batch #? Is the device available for return? Is the device past shelf-life? Reprocessed? 37

Best Practices - Effective Post market Surveillance 3. Ensure reporting procedures and processes fully comply with regulatory requirements in all regions where products are marketed Evaluate all complaints and adverse events. Regulatory AE, FAR, MDR, MDV, BPDR reportability Need for further investigation and root cause determination Balance information needed with timely decision-making; If in doubt report on-time and supplement when additional information becomes available. Use decision trees and examples to facilitate consistent decision-making; What objective evidence supports the non-reporting decision? Medical review and escalation process for safety issues and serious events & Assessment of various clinical scenarios: e.g. Treatment/Therapy not achieved Significance of delay in treatment Medical Intervention 38

Questions & Discussion