SAWEA Workshop 2010 Innovative Water and Wastewater Networks Presented by Greg Welch, AECOM

Similar documents
Water supply components

Fluid Mechanics. The Energy Equation [7] Dr. Mohammad N. Almasri

Section 7 Hydraulic Model Development and Evaluation Criteria

Calculate the Costs of Piping System Elements

Utilities are constantly striving to

Hydraulic Analysis Comparing Efficiency of One and Two Zone Pressure Water Systems

Index. Page numbers followed by f indicate figures.

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7: Hydraulic Design of Sewers and Storm Water Drains

Session 2 Pump Selection. Mark Markham, P.E. Gresham, Smith and Partners September 14, 2017

HYDRAULIC DEMONSTRATION CHANNEL

Environmental Engineering-I

Overview. We will not study pipe systems in detail as these are always solved with software. Wednesday, September 01, :21 PM.

Hydraulic Transient: Lift Irrigation Scheme

CHAPTER 6 COLLECTION SYSTEM HYDRAULIC MODEL

Facilities Development Manual

Analysis of Continuous Water Distribution in Surat City using EPANET: A Case Study

PipelineNet: A GIS Based Water Quality Model for Distribution Systems

Understanding. Hydraulics. palgrave macmillan. Les Hamill. University of Plymouth THIRD EDITION

APPENDIX G HYDRAULIC GRADE LINE

Presentation Summary. What, Why, and How. Building the Model. Facility Data Acquisition. Model Calibration. Real World Applications/Case Studies

FLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.

Water Distribution System Calibration Report

A Multi-Faceted Approach to Odor Control for a 28.5-Mile Long Force Main

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS

Module 9 : Sewage And Storm water Pumping Stations. Lecture 11 : Sewage And Storm water Pumping Stations

Irrigation Rehabilitation Program Design and Construction Standards

A techno-economical view on energy losses at hydropower dams (case study of Karun III Dam and Hydropower Plant)

Hydraulic Analysis Comparing Efficiency of One and Two Zone Pressure Water Systems

Surge Analysis for the Proposed OSIS Augmentation Relief Sewer Tunnel

3- Hydropower. Energy conversion and hydropower principles

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

Pittsburgh Water Treatment Plant Projects. by Jay R. Lucas, P.E. Senior Project Manager

Sag Pipe (depressed sewers, or Inverted siphons) Dr. Sataa A. Al-Bayati(10-11)

STUDY OF WATER DISTRIBUTION NETWORK USING EPANET

SEWER SYSTEM DESIGN GUIDELINES

Review & Design of the Apia Pressure Sewer System. Presented by Jammie Saena - Samoa Water Authority & Paul Edwards Urban Water Solutions

La modellazione per la gestione efficiente della rete idrica Pedro Pina

AR No. # Efficient Irrigation

Pinellas County Utilities provides drinking

Susceptibility of PWS to Negative Pressure Transients

SEMESTER LESSON PLANS (RPS)

Energetic Efficiency Analysis of Water Pumping Installations

6. PUMPS AND PUMPING SYSTEM

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

3.0 DESIGN CRITERIA FOR SANITARY SEWER FACILITIES

Learning objectives. Upon successful completion of this lecture, the participants will be able to:

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

DESIGN OF SEWER SYSTEMS

Phase 1 Part 2 CSO Control Plan Wellington Avenue CSO Facility. Hydraulic Modeling Software Selection

[4163] T.E. (Mechanical) TURBO MACHINES (2008 Pattern) (Common to Mech. S/W) (Sem. - II)

Analysis of Side Sluice in Trapezoidal Channel

Waterhammer Analysis Essential and Easy and Efficient

AALSO Summary of Formulas needed for Levels I, II and III.

Agenda. Streamlining I/I Repairs in Berlin Charter Township.. Innovative Techniques

Lateral Outflow from Supercritical Channels

Steady-state, transient pressure, flow analysis and design tools for piping systems.

Wastewater Flow Monitoring Services

HYDRAULICS OF CULVERTS

Pumps, Turbines, and Pipe Networks. Ch 11 Young

GREEN THREAD Piping Systems

Hancor, Inc. Drainage Handbook Hydraulics 3-1

DRAINAGE & DESIGN OF DRAINAGE SYSTEM

Long Point Water Treatment Plant Process Evaluation and Design Upgrades for Performance Enhancement; Dover, DE

Engineering & Expertise Designing Pump Sumps

BOSfluids. The Flow Simulation Tool of Choice. Services Introduction Input, Output, and Analysis Features Features and Example System and Training

The purpose of distribution system is to deliver water to consumer with appropriate quality, quantity and pressure. Distribution system is used to

Modal Analysis as a Tool to Resolve Pump Vibration Issues

Hydraulics Laboratory Experiment Report

Basic Principles for the Design of Centrifugal Pump Installations

AALSO Proficiency Program Level I, II & III

10.0 Storm Sewer Systems

PRESSURIZED IRRIGATION SYSTEM MASTER PLAN

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

Model Lift Irrigation Scheme

Unit 2. Water Distribution System Design Criteria and Planning

Irrigation Structures 2. Dr. M. R. Kabir

S T A N D A R D. ANSI/ASAE S376.2 JAN1998 (R2004) Design, Installation and Performance of Underground, Thermoplastic Irrigation Pipelines

Methods of Streamflow Analysis

4A General Information A. Concept... 1 B. Conditions... 1

ROLES AND RESPONSIBILITIES Small Pond Approval. SWM MD-378 Pond Checklist Training 10/17/07. Exemptions EMBANKMENT HEIGHT. Height of Dam Weir Wall

Air Vent Sizing in Low-Level Outlet Works for Small- to Medium-Sized Dams

Types of Water Resource Systems. Types of Water Resource Systems. Design of Water Resource Systems. Design for Public Water-Supply

nhc EARTH TECH CANADA INC. CITY OF WINNIPEG NORTH END WATER POLLUTION CONTROL CENTRE PUMP STATION MODEL TEST FINAL REPORT JANUARY 2005

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

Transient and Succession-of-Steady-States Pipeline Flow Models

Section 5 - Planning Criteria. Section 5

The Indianapolis Deep Tunnel Surge Analysis: Debugging Future Operational Issues in the Present

Piping layout for fire sprinkler system: An overview

Application of Variable Frequency Drives for Energy Savings

The Montreal Water Supply*

NZQA registered unit standard version 4 Page 1 of 5

Printing Version: for optimal viewing set the print to A3 and print two pages of the catalogue (including this one) on each sheet.

NAU Hydraulic Testing System

Water Measurement. Presentation by. L. Niel Allen Extension Irrigation Specialist Utah State University

Water Distribution Systems

Wastewater Treatment Plant Operator Training

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

RELIABILITY BASED OPTIMAL DESIGN OF A WATER DISTRIBUTION NETWORK FOR MUNICIPAL WATER SUPPLY

CFD Analysis of Clarifier Performance With and Without Energy Dissipating Inlet

1/58 Components of solar systems

Transcription:

SAWEA Workshop 2010 Innovative Water and Wastewater Networks Presented by Greg Welch, AECOM

Basic Hydraulic Principles Open channel flow Closed conduit / pressurized flow systems Orifices, weirs and flumes Pumps and pumping systems Water Hammer Computer Modeling

Select pipe sizes and fittings for piping systems Determine pumping and power requirements Choose materials which best suit application

Weight and volume 1 m 3 = 1000 kg sg = 1.00 Viscosity Low viscosity Generally not considered Incompressible Water Flows Downhill Sewage = Water (hydraulically)

Q = VA where Q = flow rate (m/s) V = average velocity (m/s) A = cross sectional area (m 2 ) Source: Haestad

R = A / P w where R = hydraulic radius (m) P w = wetted perimeter (m) A = cross sectional area (m 2 ) Source: Haestad

Water has energy, namely Potential energy, due to pressure Potential energy, due to elevation Kinetic energy, due to velocity Energy typically expressed as head (H) m or ft 1 psi = 2.31 ft 1 kpa = 0.1 m H

Bernoulli s Equation H = V 2 /2g + p/γ + z Where H = Total energy (m) p = pressure (kpa) V = Velocity (m/s) γ = water density (9.81 kn/m 3 ) g = acceleration gravity (9.81 m/s 2 ) z = elevation (m)

Energy is lost in piping systems due to friction as water moves through the pipe Affected by: Pipe size Pipe length Pipe roughness Flow rate Losses also occur in other hydraulic elements: Fittings Valves Entrance/exits Etc.

V 12 /2g + p 1 /γ + z 1 = V 22 /2g + p 2 /γ + z 2 + H L H L = head loss For Open Channel: Source: Haestad

and for pressurized pipe systems: HGL or EGL h L

Typical Design Equations: Manning s Chezy Manning s Equation: V = (1/n) R 2/3 S 1/2 where V = mean velocity (m/s) n = Manning s roughness value R = hydraulic radius (m) S = friction slope (m/m)

Typical Values: Steel 0.010 Cast Iron 0.012 Concrete 0.013 Smooth Earth 0.018 Corrugated Metal Pipe 0.024 Rock 0.040

Typical Design Equations: Hazen-Williams Darcy-Weisbach Hazen Williams Equation: S = (10.67Q 1.85 )/(C 1.85 D 4.87 ) where S = head loss (m/m) Q = Flow (m3/s) C = Roughness Coefficient D = pipe inside diameter (m)

Typical Values: PVC 150 Steel 140 Cast Iron 130 Concrete 120

Used for analysis of pipe flow and pressure in water networks Flowrate in each pipe adjusted iteratively until all equations are balanced Basis of many water network analysis programs

The method is based on: Continuity Equation: Inflow = Outflow at nodes Example Qa = Qb + Qc Energy Equation: Summation of Head Loss in Closed Loop is zero. ΣHLLoop = Σ(Q+Q)n = 0

Energy 1 = Energy 2 V 12 /2g + p 1 /γ + z 1 = V 22 /2g + p 2 /γ + z 2 + H L Q = CA (2gH) 1/2 where C = Orifice Coefficient Source: Haestad

Energy 1 = Energy 2 V 12 /2g + p 1 /γ + z 1 = V 22 /2g + p 2 /γ + z 2 + H L Source: Haestad Source: Haestad Typical V-Notch Weir

Open channel flow measurement Flow uniquely related to water depth Types: Venturi Parshall Palmer Bowlus Trapezoidal Custom flumes Parshall Flume

Head Resistance of the system Two types: static and friction Static head destination Static head Difference in height between source and destination Independent of flow Static head source Flow

Friction head Static head consists of Static suction head (hs): lifting liquid relative to pump center line Static discharge head (hd) vertical distance between centerline and liquid surface in destination tank Friction head Resistance to flow in pipe and fittings Proportional to square of flow rate Depends on size, pipes, pipe fittings, flow rate, nature of liquid Closed loop system only has friction head (no static head) Flow

In most cases: Total head = Static head + friction head System head System curve Static head Friction head System head System curve Friction head Static head Flow Flow

Relationship between head and flow Flow increase System resistance increases Head increases Flow decreases to zero Head Zero flow rate: risk of pump burnout Flow Performance curve for centrifugal pump

Pump performance curve Duty point: rate of flow at certain head Pump operating point: intersection of pump curve and system curve Head Static head System curve Flow Pump operating point 30

Cavitation or vaporization: bubbles inside pump If vapor bubbles collapse Erosion of vane surfaces Increased noise and vibration Choking of impeller passages Net Positive Suction Head NPSH Available: how much pump suction exceeds liquid vapor pressure NPSH Required: pump suction needed to avoid cavitation 31

Commonly known as Water Hammer or Surge Causes Pump start-up or shut down Power failure Sudden valve closure Impacts on system Reduces life of pipelines Noise Mechanical damage Catastrophic system failure

P = rc v/g where r = fluid density c = wave speed v = change in velocity of fluid g = gravitational constant c is influenced by pipe material P directly proportional to v

Results in surge wave propagating and reflecting in system Source: Haestad

H fluctuates at any given point after pump failure Can cause column separation Source: Haestad

At pump Pump control valves Surge anticipator valves Surge tanks Pump flywheels In Pipeline Vacuum breaker valves Air release valves Combo vacuum/air release valves Select elastic pipe materials (ie, PVC) Hydraulic modeling always recommended during design of new sewage force mains and water transmission mains.

Why computer model? Reduces time More accurate Allows integration with other software (SCADA, GIS) Currently there is considerable software for modeling available Water distribution networks Sanitary sewer networks Storm Sewer Networks Surge/transient analysis WWTP Hydraulics Water Quality Some considerations For the modeler, understanding of hydraulics just as important as understanding software Garbage in = garbage out Calibration is essential

Developing databases of system assets from multiple, complex sources Complex demand management Operations management with extended period modeling Maintaining disinfectant residual levels while minimizing disinfection by-product formation Understanding flow patterns and fate of water quality in storage facilities Assessing hydraulic transients in networks

Data Sources Geographic information systems CAD Drawings Paper maps Scanned and digitized Demands Billing databases, operating logs, production records SCADA Data Management GIS spatial tools Model software tools Custom programming

Metropolitan District Commission Hartford, CT Population Served: 400,000 Pipe Segments in Model: 4, 700 (91,000+ in GIS) Length of Pipes: 600 miles in model (1550 miles total) Water Sources: Surface Water Average Day Demand: 55.5 mgd Type of Model: EPS Software: H2OMap

Hartford Connecticut (MDC) Example Managing several different demand patterns and multipliers DEMAND FACTOR Diurnal Factor 2.5 2.0 1.5 1.0 0.5 System-Wide Curve AVG = 1.0 System-wide Diurnal Curve 0.0 0:00 3:00 6:00 9:00 12:00 15:00 18:00 21:00 0:00 Tim e of day (hr) TIME, HR MAP OF MDC DEMAND ZONES Mountain Road Zone: High-end residential. Average multiplier =2.7. DEMAN D FACTOR Diurnal Factor 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 2.5 2.0 1.5 1.0 0.5 0.0 MR_Zone Diurnal Curve 0:00 3:00 6:00 9:00 12:00 15:00 18:00 21:00 0:00 Time of day (hr) TIME, HR DEMAN Diurnal Factor D FACTOR R6_Zone Diurnal Curve 0:00 3:00 6:00 9:00 12:00 15:00 18:00 21:00 0:00 Time of day (hr) TIME, HR Reservoir 6 Gravity Zone: Mix of residential, agricultural, commercial and industrial. Average multiplier = 0.75. DEMAN D 2.5 2.0 Diurnal Factor FACTOR 1.5 1.0 0.5 0.0 Downtown Diurnal Curve 0:00 3:00 6:00 9:00 12:00 15:00 18:00 21:00 0:00 Time of day (hr) TIME, HR Downtown Zone: Primarily commercial and industrial. Average multiplier = 0.9.

Cleveland (OH) Division of Water Population Served: 1.5 million Pipe Segments in Model: 57,000 Length of Pipes: 5,350 miles Water Sources: Lake Erie (4 WTPs) Average Day Demand: 265 mgd Type of Model: Software: EPS and WQ H2ONet and SURGE

Main Uses of CWD s Hydraulic Model Assess System Flows and Pressures Evaluate Impact of System Growth Facilitate Maintenance Activities Manage Operations more Efficiently Monitor Water Quality 1 st High Service

Field Sampling Used to Develop Water Quality Model Coordinated Sampling Program Conducted by CWD Three Sessions Approx. 25 Collection Sites/Session 2-6 Samples/Site Taken Over 48 Hours Hydraulic Model Modified to Simulate Chlorine Decay Samples Used for Calibration

CFD Modeling Provides Insight on Water Quality and Flow Patterns 3.00e-01 Assess Flow Patterns 2.70e-01 2.40e-01 2.10e-01 1.80e-01 1.50e-01 1.20e-01 9.00e-02 6.00e-02 Design Baffles 3.00e-02 0.00e+00 Y Z X 2D Velocity Areas of low velocity on both sides of tank Pump Station Intakes Uniform velocity with baffles Assess Thermal Stratification Tank Without Baffles Tank With Baffles

Surge Models Created from Large System Models Base Model Skeleton Model

Impact of System Upgrades Assessed with Water Hammer Models Model Statistics Pipes = 3,709 pipes (6 48 Dia.) Nodes = 3,568 (198 Junctions & 3,370 Consumption) Pumps = 3 Tanks = 3 Simple Surge Tanks Reservoirs = 7 Fixed Head Sources Valves = 3 check/control valves, 1 surge relief valve Air Valves not included as conservative measure Base Demand ~ 72 mgd (Maximum day)

Keeping Distribution Systems in Top Working Order with Limited Funds Flushing Programs Optimize Energy Unifying maintenance activities with databases Planning for pipe replacement Condition assessments Remaining useful life analyses

Automated Tools Used to Develop Flushing Programs MWH Soft & Bentley Systems MWH Soft UDF -separate module Requires InfoWater (ArcGIS) license Bentley Includes UDF with all platforms (stand alone, CAD, ArcGIS) 50

Energy Use Optimized for Durham Region Water System

Work Planning Integration Objective: Provide the tools needed to support risk-based planning and decision making for water distribution assets Streamline the collection, management, and use of water system data in risk assessment and work prioritization