Calculate the Costs of Piping System Elements

Similar documents
AR No. # Efficient Irrigation

AALSO Summary of Formulas needed for Levels I, II and III.

AALSO Proficiency Program Level I, II & III

Successfully dosing pipe networks. Kevin Sherman, Ph.D., P.E., D.WRE Vice President of Engineering Clearstream Wastewater Systems, Inc.

Pump ED 101. Pump Selection for VFD Operation Part 3 Q / H Pump Down vs Level Control. Introduction. Pump Down vs Level Control

Water Utility Science Water Math and Hydraulics 050. Name: Date:

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

Session 2 Pump Selection. Mark Markham, P.E. Gresham, Smith and Partners September 14, 2017

Chilled Water Distribution Systems. APPA Institute for Facilities Management New Orleans, LA January 19, 2016

FLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.

Fluid Mechanics. The Energy Equation [7] Dr. Mohammad N. Almasri

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

Application of Variable Frequency Drives for Energy Savings

Hydraulics Laboratory Experiment Report

SAWEA Workshop 2010 Innovative Water and Wastewater Networks Presented by Greg Welch, AECOM

Basic Irrigation Design

Honeywell Thermal Solutions. Engineering Guide

SPILL ESTIMATION. Not Just A Guess Anymore

CHAPTER 12 TRICKLING FILTER PLANTS

VENTURI FLOW METER CALIBRATIONS SERIAL NUMBERS: , , , Prepared for. Imperial Flange and Fitting.

Rolairtrol Air Separator For Hot and Chilled Water Systems

TECHNICAL INFORMATION Bulletin NUMBER Thirty-Four

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

Performance Testing of The Robert Moses Niagara Power Plant and Sir Adam Beck Generating Station

HYDRAULIC DEMONSTRATION CHANNEL

Distribution System Basics Course Syllabus

Water Quality Specification for Power Supplies

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

System & Equipment Checkout Procedure Client Name Plant Location

MEMORANDUM. The general findings of the assessment are as follows:

FlowSet. Balancing Procedure

Ivins City Standard Specifications for Design and Construction Part 2 Engineering and Design Standards

NAU Hydraulic Testing System

Energetic Efficiency Analysis of Water Pumping Installations

GETTING A GRIP ON PRESSURE. Background

GREEN THREAD Piping Systems

Target Inline Flowmeter

EC It Pays to Test Your Irrigation Pumping Plant

Overview. We will not study pipe systems in detail as these are always solved with software. Wednesday, September 01, :21 PM.

Page of ENGINEERING DATA - HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS Use the following two tables to determine

Regulating valves REG 6-65, REG-SS 15-40

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

Technical Information

Large University Central Chiller Plant Design Considerations

6. PUMPS AND PUMPING SYSTEM

ORIFICE MTERE BASIC SELECTION & DESIGN CONSIDERATIONS. All rights reserved to thepetrostreet.com

Section 5 - Planning Criteria. Section 5

Section 7 Hydraulic Model Development and Evaluation Criteria

Problems at the Cumene Production Facility, Unit 800

VIKING BOLTED-LID BASKET-TYPE LINE STRAINERS

MICRO-HYDRO INSTALLATION SIZING Jacques Chaurette eng. January 17, 2008

TENSION. Measuring Water Flow in Surface. (a) s h. (b) Irrigation Ditches and Gated Pipe. Units of Measuring Water. Edward C.

Reclaimed Water Treatment, Distribution, Pumping and Storage Engineering Report Form

SGM Engineering, Inc.

Wastewater Flow Monitoring Services

Nodal Analysis Approach in Minimizing Pressure Losses to Improve Well Productivity

GOVERNMENT POLYTECHNIC MUZAFFARPUR LAB MANUAL OF FLUID MECHANICS AND MACHINERY LAB SUBJECT CODE

2015 DW Module 1: General Overview VOLUME III Answer Key

Clean energy saving: applied research into Etna s water supply systems in Catania, Italy

North Domingo Baca Extension at Barstow

SECTION PACKAGE BOOSTER PUMP STATIONS

Pumps, Turbines, and Pipe Networks, part 2. Ch 11 Young

Wastewater Capital Projects Management Standard Construction Specification

Design and Development of Pico-hydro Generation System for Energy Storage Using Consuming Water Distributed to Houses

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

Section V WATER DISTRIBUTION SYSTEM DESIGN GUIDELINES

Volume method Volume being used Time required to fill. Weir Method Width of slot in weir Height of water above slot

Steam balance optimisation strategies

In-line Twin Pump. Type Series Booklet. Omega DSL

ENGINEERING INFORMATION Hot water and steam service

Chlorinated Organics Closed Loop Unloading of Solvent Tank Trailers

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

SECTION 4 - DESIGN STANDARDS FOR WATER DISTRIBUTION FACILITIES

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

Pumps, Turbines, and Pipe Networks. Ch 11 Young

3.0 DESIGN CRITERIA FOR SANITARY SEWER FACILITIES

B. System Design and Performance Requirements

SEWER SYSTEM DESIGN GUIDELINES

YARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505

Pump selection: a real example

Lesson 2 Science Concepts. Chemical Characteristics of Water. The Operator as a Chemist

2011 Standard for Performance Rating Of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle

Booster Pump Fundamentals. By: Bill Baglot

The Impact Wear Behavior of Large Rocks on Slurry Pump Materials and Equipment.

Variable Speed Waste Water Pumping

Hancor, Inc. Drainage Handbook Hydraulics 3-1

Transient and Succession-of-Steady-States Pipeline Flow Models

Lesson. Using Hydraulic Systems

Field Evaluations of Irrigation Systems: Solid Set or Portable Sprinkler Systems 1

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

SECTION GRAVEL PACKED WATER WELL

Transportation of High Concentration Coal Ash Slurries through Pipelines

Series A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100

Landon Carroll R. Weston Hudkins

Enviro Voraxial Technology

Flow Meters Demonstration Unit FMDU

UNIFORM DESIGN AND CONSTRUCTION STANDARDS FOR EXTENDING WATER DISTRIBUTION SYSTEMS SECTION 2 DESIGN STANDARDS

A Multi-Faceted Approach to Odor Control for a 28.5-Mile Long Force Main

Facilities Plan. Technical Memorandum No. TM-WW-7 Hydraulic Analysis and Effluent Pump Station

Transcription:

Calculate the Costs of Piping System Elements by Ray Hardee, Engineered Software, Inc. Last month s column described the process of creating an energy cost balance sheet for a piping system (see Figure 1). The manufacturer s curve was used to calculate the cost of operation for the centrifugal pump. This column explains how to perform the detailed cost calculation for other items in the system. Evaluating Parts Figure 1 shows the operating data from the installed plant instrumentation. This operating data and the manufacturer s equipment data sheets will be used to calculate the differential pressure and flow rate through each item. With that information, the cost of electrical power and the annual rate of operation, the annual operating cost and energy use can be calculated for each item in the system s energy cost balance sheet. To calculate the operating cost for an item in the system, its head loss and corresponding flow rate must be determined. Insufficient installed instrumentation means these values need to be calculated with data from the equipment manufacturers.

Figure 1. The operating data from installed plant instrumentation and elevations of selected tanks and equipment Determining Pump Flow Rate Last month s column calculated a pump head of 235 feet (ft) and a flow rate of 4,000 gallons per minute (gpm). From the pump curve, it was determined that the pump had an efficiency of 83 percent at its flow rate. The pump s operating costs were calculated after looking at the pump s motor efficiency, annual hours of operation and cost of electrical power. So how was the flow rate through the pump of 4,000 gpm established? The flow to the destination tank is 2,500 gpm, but because there is no flow element in the bypass circuit, the pump s total flow rate cannot be calculated. Without this value, the pump efficiency and power consumed also cannot be calculated. The pump curve is the key to this process because it provides manufacturer-supplied test data on how the pump operates for its flow range. Knowing the pump s total head, the pump curve can be entered on the head axis and move across until the known pump head value intersects the pump curve. Dropping straight down on the pump curve gives the flow rate, and the intersection point provides the pump efficiency. In Figure 1, the process pump s discharge pressure is 102.8 pounds per square inch (psig). Centrifugal pump curves use head instead of pressure, so the discharge pressure must be converted to feet of fluid using Equation 1.

Where: H = Head in feet of fluid P = Pressure in lb/inch 2 ρ = Fluid density in lb/ft 3 144 is a conversion factor for ft 2 to in 2 A pressure gauge is not installed on the pump suction, so a temporary gauge was mounted on a suction vent. The temporary suction pressure gauge reads 1.7 psig, resulting in 3.95 ft of fluid. Subtracting the discharge and suction heads (239 ft minus 3.95 ft), the pump s total head is 235 ft. Reading from the pump curve (see Figure 2), the resulting flow rate through the pump is 4,000 gpm, and the pump is 83 percent efficient. the flow rate and pump efficiency from calculated total head of 235 ft Figure 2. Determining

Next, the cost to operate the system s process elements will be evaluated using their flow rates and head loss. Advertisement Static Head Cost The static head accounts for the difference in fluid energy between the destination and supply tanks. Per the Bernoulli equation, fluid energy is composed of three types of head: elevation, pressure and velocity. Because the fluid is at rest in the supply and destination tanks, the velocity head has no value (see Equation 2). Where: Z B = Elevation of tank bottom in ft L FS = Level of fluid surface above tank bottom in ft P FS = Pressure on fluid surface in psi ρ = Fluid density in lb/ft 3 1 = Supply tank 2 = Destination tank The static head is the energy difference between the supply and destination tanks. It remains the same regardless of the flow rate between the tanks. The static head can be used to calculate the annual operating cost due to the head component within the process circuit. The 2,500 gpm flow rate through the process circuit is used in the annual operating cost formula (see Equation 3). The 83 percent pump efficiency comes from the pump curve with a 4,000 gpm flow rate. The pump efficiency applies to the 4,000 gpm flow rate because the pump supplies both the process and bypass circuits. Inserting the static head pump efficiency, flow rate, hours of operating and cost of power results in an annual energy cost of $22,800 for the static head.

Where: Q = Flow rate H = Head ρ = Fluid density η ρ = Pump efficiency η m = Motor efficiency Process Element Cost Process equipment characterized by a head loss that is a function of flow rate is the next item in the energy cost balance sheet. In the system shown in Figure 1, the process element has no installed pressure gauges. The manufacturer s equipment data sheet will be used to calculate head loss. The manufacturer s supplied data sheet could have a curve showing the pressure drop and head loss for a range of flow rates, a C v value or a single value of pressure drop versus a given flow rate. For this example, the manufacturer provided a 14.4 psi pressure drop with a flow rate of 3,000 gpm. To determine the pressure drop through the process element at 2,500 gpm, the C v must be calculated using the manufacturer s supplied data points of 3,000 gpm and 14.4 psi (see Equation 4). Where: C v = Flow coefficient Q = Volumetric flow rate in gpm dp = Differential pressure in psi SG = Specific gravity

The differential pressure across the process element is 10 psi, after calculating the C v of the process elements, the specific gravity of the process fluid and the flow rate using Equation 5. The 10 psi differential pressure converts to 23.3 ft head loss across the process equipment. The head loss results in a $5,592 annual energy cost for the process element as calculated in Equation 6. Piping Cost The head loss in a pipeline can be calculated using the Darcy equation (see Equation 7). However, Equation 8 makes calculating the head loss with the flow rate in gallons per minute and pipe inside diameter in inches easier. Where: h L = pipeline head loss in ft f = Darcy friction factor (unitless) L = pipe length in ft D = pipe inside diameter in ft v = fluid velocity in ft/s g = gravitational constant in 32.2 ft/s 2

Q = volumetric flow rate in gal/min d = inside pipe diameter in inches In this example, we ll calculate the head loss for a 50-foot suction pipeline made of 16-inch schedule 40 steel. Two gate valves and a sharp edge transition lie along the pipeline from the tank. The pipeline is passing 4,000 gpm of a fluid with a fluid density of 62 lb/ft 3 and viscosity of 0.68 centipoise. The steps required to arrive at the pipeline s head loss are listed below along with the intermediate results. Reynolds number = 1.23 x 10 6 unitless Relative roughness = 0.00012 in Darcy friction factor = 0.0135 unitless Pipe head loss = 0.44 ft Valve and fitting loss = 0.57 ft Pipeline head loss = 1.01 ft (The detailed head loss calculation for this example can be found at http://kb.eng-software.com/questions/575/pipeline+head+loss+calculation+...) The head losses for the circuit s remaining pipelines are added to obtain the total pipeline head loss in Table 1.

Table 1. Pipeline summary, calculated head loss and annual operating costs for the pipelines in the process circuit The operating cost for the pipelines is $5,376, after plugging in the sum of the pipeline s head loss and the flow element, as shown in Equation 9. Control Valve Cost Control valves regulate flow rate to achieve the desired set point in this case, the level in the destination tank. The tank s outflow (not shown on the drawing) feeds the plant s demands. When the flow rates into and out of the tank are equal, the level in the destination tank is constant. To determine the operating cost, the flow rate through and the differential pressure across the level control valve are needed. Most systems do not measure the valve s differential pressure, which can be calculated knowing the valve position, flow rate and C v values as a function of valve position. But that requires involved calculations. Instead, the interaction between the pump, process and control elements can be used to calculate the head loss across the control valve. As shown in past articles, all the energy provided by the pump is used by the process and control elements (see Equation 10).

h Pump = h Process + h Control Equation 10a Substituting the calculated value for pump head and the sum of the head loss of the circuit s process elements, we can determine the head loss across the control valve. 235 = (95 + 23.3 + 22.4) + h Control Equation 10b The annual operating cost of the level control valve is $22,633, after solving for the known flow rate with 94.3 ft of control valve head loss in Equation 11. Bypass Circuit Cost The annual operation costs of the bypass and process circuits follow the same approach. The bypass circuit provides minimum flow through the pump back to prevent pump damage, and its process elements consist of the static head and the pipelines. The static head in the bypass circuit is the difference in elevations between the end of the pipeline discharging into the supply tank (30 ft) and the liquid level in the supply tank (5 ft). The head losses associated with the pipelines consist of the common pump suction and discharge header, along with the recirculation pipelines returning to the supply tank (3 ft). The control element in the bypass circuit consists of a back pressure valve (BPV) designed to maintain a 100-psi pressure on the pump discharge regardless of the system flow rate. The set point was selected so the flow rate through the pump is always greater than the manufacturer s minimum flow rate regardless of the flow to the destination tank.

Like the control valve example, the energy in the bypass circuit must balance (see Equation 12). This results in a head loss of 207 ft for the back pressure valve in the bypass circuit. 235 = (25 + 3) + h Control Equation 12 Next month s column will explain how to cross-validate the calculated results of the energy cost balance sheet and determine if the system is operating properly. ABOUT THE AUTHOR Ray Hardee is a principal founder of Engineered Software, creators of PIPE-FLO and PUMP- FLO software. At Engineered Software, he helped develop two training courses and teaches these courses in the U.S. and internationally. He is a member of the ASME ES-2 Energy Assessment for Pumping Systems standards committee and the ISO Technical Committee 115/Working Group 07 Pumping System Energy Assessment. Hardee was a contributing member of the HI/Europump Pump Life Cycle Cost and HI/PSM Optimizing Piping System publications. He may be reached at ray.hardee@eng-software.com.