High matrix tolerance of the Thermo Scientific icap 7000 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor

Similar documents
US EPA Method using the Thermo Scientific icap 7600 ICP-OES Duo

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

Sprint analysis of lubricating oils using the Thermo Scientific icap 7600 ICP-OES

EU Water Analysis Using the Thermo Scientific icap 7400 ICP-OES Duo

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Composition Analysis of Animal Feed by HR ICP-OES

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

Thermo Scientific icap 7000 Series ICP-OES Accessories Guide

The Determination of Trace Elements in Waters using the US EPA Method and the Thermo Scientific icap 6500 ICP-OES (Duo)

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES

Analysis of elemental impurities in drug products using the Thermo Scientific icap 7600 ICP-OES Duo

Analysis of Stainless Steel by Dual View Inductively Coupled Plasma Spectrometry

Analysis of Trace Metals in Surface and Bottled Water with the Optima 7300 DV ICP-OES

The Agilent Atomic Spectroscopy portfolio for Environmental applications AA, MP-AES, ICP-OES, ICP-MS & ICP-QQQ

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Thermo Scientific icap RQ ICP-MS. Simplicity, productivity and robustness for routine labs

Simple, fast and reliable analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Thermo Scientific icap Q ICP-MS

Agilent 5100 ICP-OES DUAL VIEW ICP-OES MINUS THE WAIT

Avio 200 ICP-OES Flat Plate

ICP Expert software. Technical Overview. Introduction

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

Water Analysis Using ICP-OES with an Ultrasonic Nebulizer

US EPA Method using the XSERIES 2 ICP-MS

The image part with relationship ID rid4 was not found in the file. Welcome

AMAZINGLY CAPABLE REMARKABLY AFFORDABLE. Avio 200 ICP Optical Emission Spectrometer. For research use only. Not for use in diagnostic procedures.

Automated Real-Time Determination of Bromate in Drinking Water Using LC-ICP-MS and EPA Method Application

Thermo Scientific icap 6000 Series ICP Emission Spectrometer

Selenium in Natural Waters by Graphite Furnace Atomic Absorption using EPA Method 200.9

Thermo Scientific Qtegra Intelligent Scientific Data Solution. Delivering quality. Driving productivity

The Determination of Trace Elements in Stainless Steel by Forked Platform GFAAS

Ultima Expert Ultimate ICP-OES Spectrometer Best Performance & Ease-of-Use

ABSTRACT. This study investigates the use of inductively coupled plasma-optical emission spectrometry

Quartz Glass for Ultra High Pressure and High Intensity Discharge Lamps. Heraeus Quarzglas

Kunikazu Ide and Yoshisuke Nakamura. 1. Introduction

METHODS OF ANALYSIS BY THE U.S. GEOLOGICAL SURVEY NATIONAL WATER QUALITY LABORATORY-- DETERMINATION OF CHROMIUM IN WATER BY GRAPHITE

Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

Multitype ICP Emission Spectrometer ICPE-9000 C113-E012J

Preparative HPLC is still the

Saltwater Analysis Using A High Temperature Total Organic Carbon (TOC) Analyzer with Static Pressure Concentration

GB Translated English of Chinese Standard: GB

Part I: Dealing with High Matrix Samples

ANALYTICAL PERFORMANCE OF A HANDHELD EDXRF SPECTROMETER WITH MINIATURE X-RAY TUBE EXCITATION

Quantitation of cyanotoxins in drinking water according to EPA 544 guidelines

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

National Food Safety Standard

Preliminary assessment of the metal contaminant potential of the leachate produced in a controlled sanitary landfill, Muribeca, Pernambuco, Brazil.

On site heavy metal testing and monitoring using monochromatic XRF methods

Runs On Air. AGILENT 4100 MICROWAVE PLASMA ATOMIC EMISSION SPECTROMETER

3 rd International Conference and Exhibition on Food Processing & Technology

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

DRPK-005

Method for Estimation of Na 2 O and K 2 O in Ores, Fluxes, Coal and Coke Ash by Inductively Coupled Plasma-Atomic Emission Spectroscopy

Agilent 720/725 ICP-OES RELIABLE. PRODUCTIVE. ROBUST.

The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

Prima PRO process mass spectrometer

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Microelectronics. PPQ Analysis of High-Purity DI Water Used in Semiconductor Fabs

Using low grade silicon carbide and leftover construction soil to fabricate green bricks

Fusion UV/Persulfate TOC Analyzer

New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)

CORESTA RECOMMENDED METHOD N 61

Edward F. Askew PhD Askew Scientific Consulting

Agilent 200 Series AA Systems AGILENT ATOMIC ABSORPTION SPECTROMETERS

Thermo Scientific GENESYS 10S Bio spectrophotometer

Effects of cigarette butts on coastal waters: an elemental analysis of seawater from St. Simon s Island

Core Analysis with the Tracer

EPIGENTEK. EpiQuik Histone Demethylase LSD1 Activity/Inhibition Assay Kit. Base Catalog # P-3076 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

High Purity Acids Trace Elemental Analysis. Detect as low as 1 to 100 ppt

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Reduction of the Sample Size in the Analysis of Rock by EDXRF

ab83355 ATP Assay Kit (Colorimetric/ Fluorometric)

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Application note. Guideline for validation of analytical methods using Cedex Bio, Cedex Bio HT, and Cedex HiRes Analyzers.

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Fusion UV/Persulfate TOC Analyzer

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Monitoring and fractionation of

Method Development and Validation for Online UV-Dissolution Methods Using Fiber-Optic Technology

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

SMS 100 MERCURY ANALYZER SMS 100. Mercury analysis directly on solid samples from the undisputed leader in Atomic Spectroscopy

Thermo Scientific TSQ Quantiva Triple-Stage Quadrupole Mass Spectrometer. Extreme quantitative performance. with unprecedented ease

S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar

PMI-MASTER Compact. Cost-effective, rugged and precise mobile metal analyser. Routine analysis at entry level. Easy and fast testing

UHPLC Separation of Triazine Herbicides at Elevated Temperature

Metals Analyzer. OES 6000 Optical Emission Spectrometer. fast and accurate metal analysis

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

SPECTRO XRF Report. SPECTRO xsortxhh03. Analysis of Solid Metal Samples. Summary

Standard Operation Procedure. Analysis of Major, Minor and Trace Elements in Soil and Sediment Samples with ICP-OES and ICP-MS

Thin-Layer Chromatography of Aluminium: Quantitative Densitometric Determination of Fe 2+, Ni 2+, Cu 2+, and Si 4+

Evidence of Performance regarding the requirements for float glass according to EN 572

OptiLIS 201 & 301. Online multi-parameter continuous water analyzers. OptiLIS 201 OptiLIS 301

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

SPECTRO ARCOS. ICP-OES analyzers. When results matter

SPECTRO ARCOS ICP-OES ANALYZERS. When results matter

ProQuantum high-sensitivity immunoassays

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Chemical quality of household water in Bangladesh

Transcription:

APPLICATION NOTE 43444 High matrix tolerance of the Thermo Scientific icap 00 Plus Series ICP-OES with the radial Ceramic D-Torch and the sheath gas adaptor Authors Nora Bartsch, Application Specialist, Thermo Fisher Scientific, Bremen, Germany Keywords Ceramic D-Torch, high matrix, NaCl, robustness, salt, sheath gas adaptor Goal This application note describes how routine analysis of high matrix samples like 25% NaCl can be performed with the Thermo Scientific icap 7400 ICP-OES Radial fitted with the additional gas accessory in combination with the Ceramic D-Torch and the sheath gas adaptor. Introduction The sample introduction system of an ICP-OES has a large influence on the analytical performance of the spectrometer and is the main area of the hardware that users interface with. One key component of this system is the ICP torch. The ICP torch is a relatively high cost consumable item, which can require regular maintenance and replacement when performing more demanding applications. Currently, the majority of ICP torches are made from quartz, which is a crystalline form of silicon dioxide (silica). When a quartz ICP torch is heated (by the plasma) it can undergo a process known as devitrification (which means becoming less glasslike). The process of devitrification can decrease the expected lifetime of the ICP torch and is commonly seen when samples are analyzed that contain high concentrations (greater than 0 mg L -1 ) of group I or group II elements (Figure 1).

To overcome these problems the Ceramic D-Torch was developed (Figure 2). The outer tube of the Ceramic D-Torch is made from sialon, which is a ceramic material derived from silicon nitride. The intermediate tube is made from alumina, which again has excellent properties for chemical and temperature resistance and has been proven as a material for ICP torches as it is commonly used for center tubes. When analyzing samples that contain elements that promote the devitrification process, the Ceramic D-Torch does not suffer from effects of devitrification, this is demonstrated by the analyses of 25% NaCl solution. 2A 2B When measuring high solid samples the major problem is that salts can crystallize at the tip of the torch injector tube and restrict sample transport to the plasma. Any change in the sample transport efficiency to the plasma will result in a change of signal and cause analytical drift. To prevent crystallization of the sample in the injector tube, a sheath gas can be used. A sheath gas envelopes the sample aerosol tangentially, preventing contact with the injector tube, reducing the deposition of the sample on the injector tube. As little or no sample deposition is taking place, the need for extended washing phases between samples is negated. As the use of a sheath gas enables a higher tolerance for total dissolved solids (TDS), less sample dilution is required, hence the application of the sheath gas adaptor improves method detection limits. The sheath gas is introduced between the spray chamber and the torch (Figure 3) using the sheath gas adaptor, which must be supplied with a constant gas flow of argon via a mass flow controller. Figure 2. The radial D-Torch ceramic outer tube (A) and the radial D-Torch, with a quartz outer tube to show the geometry of the intermediate tube (B). Figure 3. Radial sheath gas adaptor. 1A 1B Figure 1. Examples of devitrification (A) and premature failure (B) of quartz ICP torches.

Instrumentation The analysis of salt-containing samples is a challenge for ICP-OES. For this analysis the icap 7400 ICP-OES Radial fitted with the additional gas accessory was used with a sample introduction kit consisting of the components listed in Table 2. The radial system was chosen because of its high matrix tolerance and its ability to optimize the radial viewing height. The optimization of the radial viewing height helps to reduce spectral interferences. This is critical as interferences from carbon based emissions can be reduced especially in the visible region of the spectrum. Salt tends to be deposited in the nebulizer tip, changing the nebulization efficiency, resulting in signal drift and high RSDs. Therefore a Burgener Mira Mist Nebulizer was used to minimize salt deposition in the nebulizer tip. To allow efficient analysis of salt-containing samples as well as to overcome any challenges associated with such analysis a sheath gas adaptor was used, which prevents salt deposition forming on the inner walls of the center tube. A Teledyne CETAC ASX-5 Autosampler was used to transfer the sample to the introduction system of the ICP-OES. Sample preparation High matrix blank, calibration standards and stability solutions were prepared from single element solutions (0 mg L -1, SPEX CertiPrep Group, Metuchen, US), according to the concentrations in Table 1. The individual solutions were made with 18 MΩ ultra-pure water and trace metal grade nitric acid (67-69%, Fisher Chemical, Loughborough, UK) as well as common table salt, to a final concentration of 25% NaCl as well as 0.2% HNO 3. All solutions were spiked with 10 mg L -1 yttrium (0 mg L -1, SPEX CertiPrep). Table 1. Calibration standards and sample concentrations. Element and Blank 1 2 3 Stability solution Al 167.079 0 250 500 500 Ba 455.403 0 250 500 500 Co 228.616 0 250 500 500 Cr 205.5 0 250 500 500 Cu 324.4 0 250 500 500 Fe 259.940 0 250 500 500 Mg 279.553 0 250 500 500 Mn 257.610 0 250 500 500 Ni 221.647 0 250 500 500 Sr 216.596 0 250 500 500 Zn 202.548 0 250 500 500 Method development and analysis A LabBook was created using the Thermo Scientific Qtegra Intelligent Scientific Data Solution (ISDS) Software. For each element, s were selected using the intuitive selection tool of the Qtegra ISDS Software. The s used for analysis are shown in Table 1, these were selected as they were free from interferences and provided the sensitivity to quantify the elements of interest in the expected concentration range. Optionally, these steps can be simplified by using the Qtegra ISDS Software Element Finder plug-in. The plasma was ignited and the instrument allowed to warm up for a period of 30 minutes. Various instrument parameters were applied to reach optimal plasma conditions. The parameters used for the method can be found in Table 2. A torch alignment and a spectrometer optimization were performed directly before analysis and an AutoPeak was run within the LabBook prior to analysis. A detection limit study was carried out by analyzing the calibration blank three times with ten replicates and multiplying the standard deviation of this analysis by three. To ensure freedom from interferences, the subarray plots were examined and background correction points were set appropriately. Table 2. Instrument parameters. Parameter Pump Tubing ( Pump) Spray Chamber Nebulizer Center Tube Torch Pump Speed Flush Pump Speed Pump Stabilization Time Wash Time Setting Sample Tygon orange/white Drain Tygon white/white Baffled cyclonic Burgener Mira Mist 2.0 mm (ceramic) Ceramic D-Torch 50 rpm rpm 10 s 30 s Nebulizer Gas Flow 0.55 L min -1 Auxiliary Gas Flow 0.5 L min -1 Coolant Gas Flow 12 L min -1 Additional Gas Flow 0.1 L min -1 RF Power Radial Viewing Height Exposure Time 1400 W 10 mm UV 15 s, Vis 15 s

Results The linearity of the calibration curves is very good with correlation coefficients greater than 0.999 for each. Exemplary calibration curves for Ba 455.403 nm and Al 167.079 nm are shown in Figures 6 and 7. Recoveries of the spiked samples are within a range of 97-104% (Table 3). The 10 hour long-term stability data also show recoveries within the range of -% (Figures 4 and 5). The method detection limits (MDL) for most elements are in the single digit μg L -1 range or lower (Table 3). Table 3. Analytical, correlation coefficient R 2 and internal standard used for the analysis, as well as spike recoveries and method detection limit (MDL) for each element. Element and R 2 Internal standard Known spike concentration Measured spike concentration MDL Al 167.079 0.9997 Y 224.306 500 497.2 97.2 4.1 Ba 455.403 1.0000 Y 317.030 500 499.9 99.9 0.9 Co 228.616 0.9999 Y 224.306 500 500.6.6 10.6 Cr 205.5 0.9999 Y 224.307 500 500.5.5 4.5 Cu 324.4 0.9999 Y 324.228 500 501.7 101.7 13.0 Fe 238.204 0.99 Y 320.332 500 503.2 103.6 8.8 Mg 279.553 0.9999 Y 320.332 500 501.0 101.0 0.5 Mn 257.610 0.9999 Y 320.332 500 501.1 101.1 1.7 Ni 221.647 0.9999 Y 224.306 500 500.8.8 8.0 Sr 216.596 0.9999 Y 224.306 500 501.3 101.3 10.2 Zn 202.548 1.0000 Y 224.306 500 499.9 99.9 2.0 10 h stability in 25% NaCl λ >230nm 0 1 2 3 4 5 6 7 8 9 10 Fe 238.204 Mn 257.610 Mg 279.553 Cu 324.4 Ba 455.403 ±10% Figure 4. Results obtained for the 10 hour stability analysis (s > 230 nm). 10 h stability in 25% NaCl λ <230nm 0 1 2 3 4 5 6 7 8 9 10 Al 167.079 Zn 202.548 Cr 205.5 Sr 216.596 Ni 221.647 Co 228.616 ±10% Figure 5. Results obtained for the 10 hour stability analysis (s < 230 nm).

Figure 6. Calibration curve for Ba 455.403 nm. Figure 7. Calibration curve for Al 167.079 nm. Conclusion The Thermo Scientific icap 7400 ICP-OES Radial fitted with the additional gas accessory used in conjunction with the Ceramic D-Torch, baffled spray chamber, the Burgener Mira Mist Nebulizer and the sheath gas adaptor allows for ultimate high solids tolerance. Moreover, very good spike recoveries indicate that an internal standard is capable of correcting for physical interferences induced by this complex sample matrix. The sheath gas adaptor isolates the sample stream, which reduces sample deposition on the center tube and torch surfaces. It is easy to use and maintain with the icap 7400 and icap ICP-OES instruments, enabling improved long-term stability when high TDS samples like 25% NaCl are analyzed. This is demonstated in Figure 8, which shows the results of the measurement under the same conditions without sheath gas. In addition, the Ceramic D-Torch improves the robust instrument performance and the powerful software platform Qtegra ISDS Software simplifies method development and makes postprocessing of the sample data an easy operation. < 2 h stability in 25% NaCl without sheath gas 0:00 0:20 0:40 1:00 Al 167.079 Sr 216.596 Ni 221.647 Mg 279.553 Ba 455.403 ±10% Figure 8. Results obtained for less than 2 hour stability analysis without sheath gas. Find out more at thermofisher.com/icp-oes For Research Use Only. Not for use in diagnostic procedures. 2017 Thermo Fisher Scientific Inc. All rights reserved. Burgener Mira Mist is a trademark of John Burgener of Burgener Research Inc. Tygon is a trademark of Saint- Gobain Corporation. SPEX CertiPrep is a trademark of the SPEX CertiPrep Group LLC. CETAC is a trademark of Teledyne CETAC Technologies INC. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manner that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. AN43444-EN 0417