REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES

Similar documents
Installation instructions Thin, flexible multi-foil insulation

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls

PITCHED ROOF SOLUTIONS

AirSmart. The intelligent choice in airtight systems. Superior strength and quality. Energy saving and cost effective. Reduces condensation risk

URSA MINERAL WOOL URSA HOMETEC Cladding Roll

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited


MULTIFOIL INSULATION PRODUCT SHEET 1 THINSULEX SILVER

Multi-layer Insulation Blanket for use in Walls

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

URSA MINERAL WOOL URSA 10 & URSA 20 DIVERSO Loft Roll

URSA 20 Plus and URSA 20

Insulating breather membrane

Garage Conversion - Between and Under Joist Applications

MULTIFOIL INSULATION TLX GOLD INSULATING BREATHER MEMBRANE FOR PITCHED ROOFS

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

TYVEK CONSTRUCTION MEMBRANES DUPONT AIRGUARD REFLECTIVE

Brick Veneer Walls. Insulation

TYVEK CONSTRUCTION MEMBRANES TYVEK REFLEX INSULATING BREATHER MEMBRANE

TECHNICAL DOCUMENTATION

BDA Agrément BAW /01/C

August 2008: Issue 1. Non - Residential New Build Pitched Roofs - Ceiling Level

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internal Wall PRODUCTS: Vencel Resil Limited

CHAPTER 3: Modern Methods of Construction (MMC)

URSA MINERAL WOOL URSA Acoustic Roll

Double Brick Cavity Walls

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

PROVIDING PROTECTION IN CONSTRUCTION Volume 2: Walls and Floors

URSA MINERAL WOOL URSA Cavity Batts

June Residential New Build Render and cladding walls

GENERAL INSTALLATION GUIDELINES

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Product Information Sheet

Glidevale offers a complete range

VISQUEEN RADON MEMBRANE SYSTEM

Healthy Living Heat out, Healthy Living in. Summer Heat Protection. engineered by nature

Vario XtraSafe. Airtightness and moisture management system.

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Futureproof solutions. Your Guide to Building Energy Ratings (BER)

Engineered Timber Systems AN INTRODUCTION. Low Energy Low Carbon Buildings. CI/SfB (2-) Rj7 - Thirteenth Issue September 2017

Floors Walls Roofs. Jabroll. APPLICATION: Flat and Curved Roofs PRODUCTS: Vencel Resil Limited

Insulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings

June Non - Residential Refurbishment Internal lining walls

The extra strong, extra durable, sound resistant system that you can direct fix to

External Wall Insulation Systems GUARANTEED TO PERFORM!

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS. P E R F O R M A N C E Manufactured to BS EN ISO 9002: 1994 Certificate No.

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

Thermal Laminate Board.

HP Partial Fill. Robust, long-lasting protection

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung

Module Approved construction details

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

Construction details:

BRE Global Test Report

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

BALLYTHERM INSULATION BALLYTHERM BTR PITCHED ROOF INSULATION

LAPOLLA SPRAY APPLIED OPEN CELL INSULATION LAPOLLA ATOC

Warmer Roof. Transforming conservatory roofs. WarmerRoof

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

The Role of Control Layers in Building Enclosure Design

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

K5 External Wall Board

The Role of Control Layers in Building Enclosure Design

SMARTPLY PROPASSIV - AIRTIGHT OSB

Thermablok Aerogel Isolation Strips Thermablok Aerogel Isolation Strips

Agrément Certificate 07/4420 website: Product Sheet 2

Staggered stud acoustic partition system

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

Gas barrier and damp proofing accessories

PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs

Fire safety issues with balconies

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Airspace R-Values. Educational Overview. Revised 12/6/2016

XTRATHERM XTROLINER (XO) XTRATHERM XTROLINER RAINSCREEN BOARD (XO/RS)

AIRCOOL VENTILATORS FURTHER INFORMATION

LAPOLLA SPRAY APPLIED CLOSED CELL INSULATION LAPOLLA FL2000 (FOAM-LOK)

Gas Protection System Components

FENTRIM SEALING TAPES

Limiting thermal bridging and air leakage: Robust construction details for dwellings and similar buildings. robust details

HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD

CERTIFICATE OF APPROVAL No CF 563 SIDERISE INSULATION LIMITED

A. Source Limitations: Obtain each type of building insulation through one source.

ROOF RENOVATION OVERSHEETING SYSTEM

Your reference for Recticel PIR insulation.

BRE Global Assessment Report

Building Regulations Part L1A (2006)

KINGSPAN INSULATION KOOLTHERM K15 RAINSCREEN INSULATION BOARD

DEMILEC SPRAY APPLIED OPEN CELL INSULATION SEALECTION AGRIBALANCE INSULATION FOR EXTERNAL WALLS

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Transcription:

CI/SfB (47) Ln6 Uniclass Pr_25_57_10_68 January 2018 REFLECTIVE TECHNOLOGY CONSTRUCTION MEMBRANES................................

........................................................ REFLECTIVE TECHNOLOGY MEMBRANES......................................................................... As fabric energy efficiency is becoming increasingly legislated by Building Regulations and Standards, the benefits of lower energy consumption and therefore costs to the building occupier are easy to understand. However, the modern builder needs to find ways to construct the dwelling to meet these standards whilst ensuring that the property remains affordable to potential buyers. Building Regulations and Standards set upper limit U-values for construction elements, but in order to meet the more onerous fabric energy efficiency targets, a Notional Dwelling specification has been developed which is much more demanding - typical values can be seen below. Element Upper limit Notional Dwelling Improvement or system value specification value required Roof 0.20W/m 2 K 0.13W/m 2 K 35% Walls 0.30W/m 2 K 0.18W/m 2 K 40% Floors 0.25W/m 2 K 0.13W/m 2 K 48% Airtightness 10m 3 /hr/m 2 5m 3 /hr/m 2 50% Low emissivity technology The Protect range of Reflective Technology construction membranes utilises high purity aluminium foil to provide low emissivity, radiant barriers. When installed facing into an unventilated airspace (as defined in BS EN ISO 6946), they effectively block infra-red radiation and enhance the thermal performance of the airspace. This, in turn, improves the overall thermal resistance of the wall construction. This provides design flexibility and cost savings when achieving these more onerous U-value targets. Emissivity of Protect s reflective surfaces has been tested in accordance with BS EN 15976 and thermal resistance performance in a wall construction has been tested in accordance with BS EN ISO 8990. Applications In order to meet the onerous fabric energy efficiency targets, a timber frame wall needs to combine thermal efficiency with a flexible airtightness solution to ensure long-term compliance whilst minimising the energy costs to the eventual building occupier. In addition, the wall panel must also effectively minimise the risk of harmful condensation. Timber frame construction requires both a breathable membrane on the outer sheathing or cold side of the panel, which also provides temporary protection against the elements, and an air and vapour control layer (AVCL) on the internal or warm side of the panel. As improved airtightness has become more crucial to modern, energy efficient construction, it is now common practice to include a batten between the AVCL membrane and the internal lining board to create a circa 25mm deep void to route services without having to puncture the AVCL membrane, thus maintaining its integrity. Switching from traditional vapour control membranes to insulating AVCL membrane will provide both airtightness and vapour control. With the low emissivity foil faced surface facing into the service void airspace, the wall structure will benefit from additional thermal performance. Replacing a standard Protect TF200 breather membrane on the outer sheathing boards with insulating breather membrane will ensure that the wall structure will benefit from additional thermal performance when the low emissivity foil faced surface faces into the drainage cavity. Using Protect TF200 Thermo will provide protection to the panel during the construction process and will also allow the panel to dry out once the external cladding is completed.... 2

................................................................................................................................................................................................................................ The innovative insulating breather membrane can be installed either on the cold side of the panel, on the inside face of the sheathing board, or on the warm side of the panel behind the vapour control layer. In all instances, the insulation is held in position within the studs to facilitate the... U-value performance tables Table 1 Timber frame construction with Protect TF200 standard breather membrane 20mm airspace by a Protect Cavit-E Tray for mineral wool slab insulants (see table 3 image). Innovative, rigid EPS insulants such as Jablite JTWS-TF have integral ribs on both sides to maintain the 20mm airspaces, removing the need for the Cavit-E Trays (see table 4 image). The tables below show typical U-value results when combining the Protect range of Reflective Technology construction membranes with differing lambda insulants. Table 2 Timber frame construction with insulating breather membrane and insulating AVCL membrane (Showing mineral wool insulation) Air and vapour control layer - Timber frame (insulation between studs) 140.0 4.375 4.000 Protect TF200 Unventilated air cavity 50.0 0.180 0.180 Total 317.0 4.102 3.877 U-value W/m 2 K (rounded) 0.25 0.26 (Showing mineral wool insulation) Low emissivity service cavity 25.0 0.780 0.780 Timber frame (insulation between studs) 140.0 4.375 4.000 Unventilated air cavity 50.0 0.770 0.770 Total 342.0 5.590 5.329 U-value W/m 2 K (rounded) 0.19 0.20... 3

............. Table 3 Timber frame construction with, and a single layer of Protect TF InterFoil low emissivity membrane Table 4 Timber frame construction with, and two layers of low emissivity membrane (Showing mineral wool insulation and Cavit-E Tray) Low emissivity service cavity 25.0 0.780 0.780 Timber frame (insulation between studs) 120.0 3.750 3.429 Unventilated air cavity/cavity-e Tray 20.0 0.770 0.770 Unventilated air cavity 50.0 0.770 0.770 Total 342.0 5.689 5.468 U-value W/m 2 K (rounded) 0.18 0.19 (Showing Jablite JTWS-TF insulation with integral ribs) Low emissivity service cavity 25.0 0.780 0.780 Unventilated air cavity 20.0 0.770 0.770 Timber frame (insulation between studs) 100.0 3.125 2.857 Unventilated air cavity 20.0 0.770 0.770 Unventilated air cavity 50.0 0.770 0.770 Total 342.0 5.787 5.079 U-value W/m 2 K (rounded) 0.18 0.19... 4

............................................................................ THE REFLECTIVE TECHNOLOGY PRODUCT RANGE.............................................................................................. A high performance, highly reflective, low emissivity insulating breather membrane which combines high tear strength with weather resistance and vapour permeability. Available in the following roll sizes: 0.3m x 100m, 0.6m x 100m, 1.5m x 50m, 2.7m x 100m and 3.0m x 100m. An innovative, highly reflective, low emissivity insulating breather membrane which has been designed specifically for use within a timber frame wall panel on either or both sides of the insulation to enhance thermal performance. Available in the following roll sizes: 1.2m x 100m and 2.4m x 100m. A robust and highly reflective, low emissivity insulating air and vapour control layer which has been developed to enhance the thermal performance of walls, ceilings and floors. Available in the following roll sizes:1.35m x 50m, 1.5m x 50m (both sizes with and without integral lap and sealing tapes), 2.7m x 50m, 2.7m x 100m and 3.0m x 50m. Protect Cavit-E Tray A purpose designed, translucent insulation spacer / support tray to create a circa 20mm air cavity within the depth of the wall stud, used in conjunction with, and mineral wool slab insulants. Protect Cavit-E Clip Specifically designed for use with Protect VC Foil Ultra. The clips are fixed over studs or rafters holding the reflective membrane in place to create a 25mm airspace. Available in 2.2m lengths but can be cut on site into smaller lengths. Available in boxes of 50 to suit 600mm stud centres but can be cut on site to suit other sizes............................................................................................... 5

.................................................................................. PROTECT LAP AND SEAL TAPE RANGE..................................................................................................... The Protect Lap and Seal tape range has been developed to complement the Protect range of construction membranes to help reduce uncontrolled air leakage in all forms of building construction. Reveal Tape Single-sided high-tack, extremely durable woven reinforced reflective tape, ideal for dressing into awkward details without tearing. Performs the airtightness function between the internal AVCL and the external cladding or membrane in and around doors and window reveals. Available in the following roll sizes: 50mm x 50m, 75mm x 50m, 150mm x 20m, 200mm x 50m and 300mm x 50m. Reflective Reinforced Tape Designed for sealing overlaps of timber frame membranes, air barriers and vapour control layers and for sealing around service penetrations. Can be used for internal or external applications. Available in the following roll size: 50mm x 50m. RELATED PRODUCTS For airtightness applications, Protect offers BarriAir, a high performance and multi-purpose, coated non-woven membrane with integrated lap and sealing tapes which forms a highly effective air leakage barrier with vapour control qualities. The Protect FCM750 Floor Cassette Membrane is a high performance, airtight yet vapour permeable membrane which maintains the integrity of airtightness at intermediate floor junctions without the risk of interstitial condensation. Protect's Party Wall Air Barrier (PWAB) membrane in conjunction with Protect Tapes and full-fill insulation enables airtightness and the Notional Dwelling target value to be met in accordance with Building Regulations...................................................................................................... Stockist s stamp PROTECT MEMBRANES 2 Brooklands Road, Sale, Cheshire M33 3SS Tel: 0161 905 5700 Fax: 0161 905 2085 Email: info@protectmembranes.com Web: www.protectmembranes.com Protect Membranes maintains a policy of continuous development and reserves the right to amend product specifications without notice. A division of Building Product Design Ltd. Company Registration No: 3944123...... 910035 January 2018 4773 ISO 9001 OHSAS 18001