Building Science Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, Straube buildingscience.com 1 of 24

Similar documents
When R-Value Doesn t Measure Up

This presentation. Basements: New & Retrofit. Basements Part of the Enclosure. Basements are Changing. Basement functions Basement Performance

This presentation. Functions of the building enclosure. University of Waterloo and Balanced Solutions. Straube Presentation Building Canada

Thermal Bridging in Residential Construction

Vapor Barriers and Air Barriers

Continuous Insulation Systems for Exterior Walls

Spray Polyurethane Foam: The Need for Vapor Retarders in Above-Grade Residential Walls

Insulating Exterior Assemblies : Batt, Blown / Spray, Board and Beyond

Insulation Technologies and Installation Specifications for Better Energy Performance of Commercial Buildings

Smart Vapor Retarders

Building America Special Research Project: High-R Walls Case Study Analysis

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

ENERGY PERFORMANCE R-VALUE: PART 2, EXAMPLES OF INTEGRATED METHODOLOGY FOR EVALUATION OF ENERGY EQUIVALENT R-VALUE FOR BUILDING ENCLOSURES;

Attic Insulation. Student Guide

The Role of Control Layers in Building Enclosure Design

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

2013 COMMERCIAL PRODUCTS

Insulating Basements: Part 1 Fundamentals

Integrated Solutions for Every Insulation Need. Complete Comfort

Learning Objectives. Introduction to Building Science. Copyright Materials. March 8, 2011

Foam Vs Fiber. Air Sealing Benefit of Foam in Single Family Residential New Construction. Gary Parsons Fellow, Dow Building Solutions R&D

Vapour Diffusion for Residential Construction. Canada and Northern USA VAPOUR DIFFUSION FOR RESIDENTIAL CONSTRUCTION CANADA AND NORTHERN USA

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Moisture Considerations for Insulated Building Assemblies

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

Improve Energy Efficiency and Air Sealing in Above-Grade Walls

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

2

Insulation Technologies and Installation Specifications for Better Energy Performance of Commercial Buildings

Background Basement Thermal Behavior

Residential Product Selector Guide

Open and Closed Cell Spray Foam Insulation

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

10 Steps to Save Energy in Your House

Advanced technologies for enhancing the building envelope. 3M Building and Construction Market

Insulation Terms, Definitions & Formula

Recommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation

Building Enclosure Details and Assemblies for Wood-Frame Buildings

2006 Building Science Press All rights of reproduction in any form reserved.

Throughout the balance of this paper the terms attic and roof will and can be used interchangeably.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

A. Source Limitations: Obtain each type of building insulation through one source.

Insight. New Light in Crawlspaces. By Joseph W. Lstiburek, Ph.D., P.Eng., Fellow ASHRAE

Vancouver Field Exposure Facility: Phase IV Construction and Instrumentation Report

The REMOTE Wall System

How to Meet Code and Manage Moisture in an Environment of Increasing Air Tightness Requirements. Ted Winslow

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

Air Infiltration & Insulation

Construction Report NYSERDA Residential Performance Challenge

ASTM Volume 04.06, November 2016 Thermal Insulation; Building and Environmental Acoustics

Technical Guide DELTA -VENT SA

Overview. Insulating Load-Bearing Masonry Buildings. Learning Objectives

Chapter Meeting: Joint Meeting with Boston CSI and ICRI at Granite Links Insulating Load-Bearing Masonry Building January 8, 2014

Hardin County Planning and Development Commission

How Does Insulation Work for You? 2. Insulating a New Home 10. Make Your Selection 14. Check the Label Before You Buy 14. Can You Do It Yourself?

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

2015 IECC Whole Building Air Leakage Compliance

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product

Net Zero Building Enclosure Retrofits for Houses: An Analysis of Retrofit Strategies

Flood and Hurricane Resistant Buildings by Joseph Lstiburek

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Sealing the Envelope with SPF Insulation

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

Inspection of New One- and Two- Family Dwellings

Background. BSC Website Builder Resources. Building America Innovations

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

Beginning of the Course

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

Exterior Perspective, East End

Parex Continuous Insulation (CI)

Graphite Polystyrene (GPS) Rigid Insulation. High Performance Thermal Innovation

The Role of Control Layers in Building Enclosure Design

Six Proven Ways to Build. Walls

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

Exterior Building Materials & Detailing

HPW Protocol Reference Manual

Inside Why Spray polyurethane Foam insulation? All About Spray polyurethane Foam Book 1

EcoTouch Insulation with PureFiber Technology

MOISTURE CONDITIONS IN WALLS AND CEILINGS OF A SIMULATED OLDER HOME DURING WINTER

Slab edge insulation is one of

GOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO

Carpenter Level 2 Rev. September 2017

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

building science.com Building Science Digest 106 Understanding Vapor Barriers (rev. April 2011) by Joseph Lstiburek Abstract:

Local Temperature Measurements on Full-Size Systems in the Laboratory: Insight into the Extent of Thermal Bridges in Building Envelope Components

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

Integrated Wall Retrofit Solutions for Existing Masonry Construction for Commercial Buildings

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Improve Energy Efficiency and Moisture Performance of Foundations

Crawl Spaces and Basements: Defining the Building Envelope

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Lock In Energy Savings For Life

Boulder City NV Prepared by (Print Name) Signature Date

Transcription:

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Straube buildingscience.com 1 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Straube buildingscience.com 2 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Straube buildingscience.com 3 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 R2 Insulation - History Density vs R-value It s the law 2008 Insulation and Thermal Bridges No. 13/65 R2 Insulation - History R6 R2 R6 R6 Insulation - History Straube buildingscience.com 4 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 R2 R6 R6 Insulation - History R2 R6 R6 Insulation - History R6 R6 R3 4 2008 www.buildingscience.com R2 R6 R6 R2 R6 R6 Insulation - History Insulation - History R6 R3 R4 R6 R3 R4 R1.5 R5 2008 www.buildingscience.com Insulation and Thermal Bridges No. 19/65 R5 2008 www.buildingscience.com Insulation and Thermal Bridges No. 20/65 Straube buildingscience.com 5 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 R2 R6 R6 Insulation - History Changing Needs Now and tomorrow R6 R3 R4 Better heat flow control required More environmental concerns re: energy R1.5 R2 More demanding comfort standards Building materials & finishes are less resistant to condensation (& mold) R5 2008 www.buildingscience.com Insulation and Thermal Bridges No. 21/65 2008 Insulation and Thermal Bridges No. 22/65 Materials Insulation Thermal conductivity (& resistance) varies with material type (conduction, radiation) density and pore structure moisture content temperature difference Combination of insulation of air + material Still air is about R6/inch (k=0.024 W/mK) Only gas fills (e.g. HCFC) can improve this A brief survey... 2008 Insulation and Thermal Bridges No. 23/65 2008 Insulation and Thermal Bridges No. 24/65 Straube buildingscience.com 6 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Fibers R SI per 25 mm 6 4 2 R-value per inch Mineral Fiber Insulation (vs organic fibers) glass fiber rock fiber slag fiber rockwool Glass vs rockwool melts at a much lower temperature has thinner fibers so can use lower density Lower density means more air permeance, less strength, and low volume (less cost and energy) shipping Insulation and Thermal Bridges No. 25/65 Insulation and Thermal Bridges No. 26/65 Blown/spray fibrous insulation Can use cellulose, glass, rockwool Net or adhesive holds sprayed fiber in cavity fills space and around obstructions avoids settling problems? May help control convection Are NOT vapour barriers Cellulose Wall Spray Insulation Density 2.5 to 4+ pcf (> 3pcf is recommended) R value 3.5 +/- depending on density Helps controls convection (higher density=better) Can fill irregular cavity spaces Settling a concern with low density (< 3pcf) Built in moisture concerns (MC? at close in) Provides moisture storage Controls mold with borate salts (avoid ammonia) Is not part of an air barrier system! Insulation and Thermal Bridges No. 27/65 Insulation and Thermal Bridges No. 28/65 Straube buildingscience.com 7 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Blown Cellulose Can act as thermal (fire) control layer over foam 2008 Insulation and Thermal Bridges No. 29/65 2008 Insulation and Thermal Bridges No. 30/65 Spray Foam Spray Foam Primarily polyurethane foam open cell (CO 2 blown) e.g., Icynene about R3.7/inch (R13/3.5, R20/5.5 ) moderate to high vapour permeance (>10 perms) Airtight <0.01 lps/m 2 @ 75 Pa closed cell (gas blown) R6+/inch 1-2 US perms (don t need vapour barrier) Airtight <0.01 lps/m 2 @ 75 Pa Depends on skin Open cell Most high vapor permeance controls convection / wind washing Closed cell air barrier and part vapor barrier excellent air seal in difficult areas! Beware: adhesion and movement/shrinkage cracks Both Expensive Neither solve air leakage outside of stud cavity Insulation and Thermal Bridges No. 31/65 Insulation and Thermal Bridges No. 32/65 Straube buildingscience.com 8 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Great for sealing/insulating difficult complex details Complete air-vapourwater barrier solution Requires transition membranes Insulation and Thermal Bridges No. 33/65 Insulation and Thermal Bridges No. 34/65 Residential Air Sealing, Attics, Basements Hybrid: Air, thermal R6+R30 4 (R25) or 6 (R38) HD spray foam R6+R16 2x6 wood frame 3.5 spray cellulose/fiberglass 2 HD spray foam Cold Climate Zone 2008 Insulation and Thermal Bridges No. 35/65 Insulation and Thermal Bridges No. 36/65 Straube buildingscience.com 9 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 R40+ roof, fire protection Cold Climate (Zone 5/6) Solution Foam-filled stud space Air Sealing Framed Walls with Foam: foam the details! Most air leakage at rim joist windows penetrations bath rooms Insulation and Thermal Bridges No. 37/65 Insulation and Thermal Bridges No. 38/65 Rigid Boards (sheathing) Expanded Polystyrene (EPS) R-value of 3.6 to 4.2 Extruded Polystyrene (XPS) higher R-value, usually 5/inch or higher usually more strength Polyisocyanurate (PIC) Highest temp resistance. Long term R6 all have fire issues Insulation and Thermal Bridges No. 39/65 Insulation and Thermal Bridges No. 40/65 Straube buildingscience.com 10 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Mineral Fiber Sheathing Semi-rigid MFI (mineral fiber insulation) Rockwool and Fiberglass Air permeable Vapor permeable Allows drainage (provides gap) R values of 4 to 4.4/inch 2008 Insulation and Thermal Bridges No. 41/65 Insulation and Thermal Bridges No. 42/65 2008 Insulation and Thermal Bridges No. 43/65 2009 Insulation and Thermal Bridges No. 44/65 Straube buildingscience.com 11 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Structural Insulated Panels Advantages Superior blanket of insulation (3.5 =R12, 5.5 =R20) if no voids then no convection or windwashing May seal OSB joints for excellent air barrier system Therefore, done right = excellent Small air leaks at joints in roofs can cause problems Don t get them too wet from rain Low perm layers means limited drying Insulation and Thermal Bridges No. 45/65 2008 Beware Joints No vapor barriers Insulation and Thermal Bridges No. 46/65 Insulated Concrete Forms Excellent enclosure system Concrete acts as air barrier No vapor barrier needed Expensive, but high performance (R20) Future products Vaccum panels: Depends on vacuum R20-30/inch VacuPor (Porextherm) Nanogel/aerogel R12-20/inch Aspen Aerogel Insulation and Thermal Bridges No. 47/65 Insulation and Thermal Bridges No. 48/65 Straube buildingscience.com 12 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Radiant barriers There MUST be an airspace for radiant products to work Often misunderstood Must have an air space!!! (below slabs?) Performance depends on temperature difference better at high temperatures, e.g., roof, South Can be useful (R5 or so) if low cost Most effective at high temperatures (radiation T 4 ) How reflective is the material over time? Are dust and corrosion avoided? Insulation and Thermal Bridges No. 49/65 2008 Insulation and Thermal Bridges No. 50/65 How much insulation? Regardless of type, use more Comfort & moisture True R5-10 is usually enough, but.. For energy / environment As much as practical Practical constraints likely the limit How much space available in studs? Exterior sheathing of 1.5 /4 Increased insulation should reduce HVAC capital as well as operating! 10 10 20 Insulation and Thermal Bridges No. 51/65 Insulation and Thermal Bridges No. 52/65 Straube buildingscience.com 13 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 But there are Complications Combined Air and Conduction Flow (70F indoors 0F outdoors) Add up the R-values of the layers to get the total R-value of the assembly BUT the actual thermal resistance of an assembly is affected by o Air Leakage o Thermal Bridges o Thermal Mass 2 lps/m 2 @ 75 Pa Insulation and Thermal Bridges No. 53/65 Insulation and Thermal Bridges No. 54/65 The Meaning of R-value 2 lps/m 2 @ 75 Pa 0.5 lps/m 2 @ 75 Pa Thermal Resistance R-value (material property, not system) Thermal Bridging Airtightness and Air Looping About 10-40 % of energy loss Mass smooths peaks and valleys takes advantage of heat within (sun, equipment) Buildability / Inspectability do you get what you spec/design? Insulation and Thermal Bridges No. 55/65 Insulation and Thermal Bridges No. 56/65 Straube buildingscience.com 14 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Internal Stack Effect & Insulation Gaps in batt insulation on both sides Wrinkles inevitable Hot side Hot air = light Batt Air gaps Internal Stack Effect Gaps in batt insulation on both sides closed circuit energy cost cold surfaces Cold air = heavy Cold or Hot Weather Hot air = light Result: Air Flow Cold Side Common problem Cold air = heavy Cool Side Hot Side Insulation and Thermal Bridges No. 57/65 Insulation and Thermal Bridges No. 58/65 Steel studs provide conduits Hard to fill steel studs Results in gaps in batt insulation on both sides Hot Hot air = light Batt Air gaps Cold air = heavy Cold 2008 Insulation and Thermal Bridges No. 59/65 2008 Insulation and Thermal Bridges No. 60/65 Straube buildingscience.com 15 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Attics Large temp differences in winter & summer (large temp diffs cause probs) One side open to air Cold Attic Air Hot air = light Thermal mass A heat capacitor, stores heat or cold Smooths variations Reduces peak loads (Title24) Can reduce energy if Daily temps vary above/below interior temp Energy flows can be stored, eg solar energy or office waste heat 90 F Cold air = heavy Batt Air gaps 2008 Inside Insulation and Thermal Bridges No. 61/65 2008 60 F Insulation and Thermal Bridges No. 62/65 It s More Than Insulation! Thermal bridges provide shortcut for heat through insulation Heat passes through the structural members Common offenders Floor and balcony slabs Shear walls Window frames Steel studs 2008 Insulation and Thermal Bridges No. 63/65 Insulation and Thermal Bridges No. 64/65 Straube buildingscience.com 16 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Find the thermal bridge Find the thermal bridge 2008 Insulation and Thermal Bridges No. 65/65 Insulation and Thermal Bridges No. 66/65 Thermal Bridging Steel is 400 times more conductive than wood Steel studs are about 40 times thinner R<0.3 Cold R=4+ 2008 It s More Than Insulation! Insulation and Thermal Bridges No. 67/65 Batt Hot 3.5 wall Insulation and Thermal Bridges No. 68/65 Straube buildingscience.com 17 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Wood vs Steel ASHRAE 90.1 Clear Wall best case 25 20 Steel Wood Studs Simple framing Wood Studs 15 ClearWall Nominal R-value 10 5 0 R-11 3.5in R-13 3.5in R-19 6in R-21 6in R-11 3.5in R-15 3.5in R-19 6in R-21 6in ClearWall 5.5 6.0 7.1 7.4 8.4 10.0 12.9 13.8 Nominal 11 13 19 21 11 15 19 21 Insulation and Thermal Bridges No. 69/65 Insulation and Thermal Bridges No. 70/65 ASHRAE 90.1 Clear Wall best case 25 Steel Studs Wood Studs R-value Comparison Rcc Ravg (steel framming ) Ravg 20 (wood framming ) 19.8 exterior sheathing stud depth interior sheathing 19.8 steel or wood stud wall stud spacing R-value 20 15 10 ClearWall Nominal 15 R-value (ft 2.o F. hr/btu) 10 5 6.6 55 % 12.1 10.8 89% 12.1 11.2 93% 7.9 65% 8.8 44 % 16.2 82 % 10.9 55 % 16.9 85 % 5 0 R-11 3.5in R-13 3.5in R-19 6in R-21 6in R-11 3.5in R-15 3.5in R-19 6in R-21 6in ClearWall 5.5 6.0 7.1 7.4 8.4 10.0 12.9 13.8 Nominal 11 13 19 21 11 15 19 21 0 2x4@16" 2x4@24" 2x6@16" 2x6@24" R11 Batt R19 Batt Wall Construction (Stud Size and Spacing ) From : Bombino and Burnett, Pennsylvania Housing Research Center Insulation and Thermal Bridges No. 71/65 Insulation and Thermal Bridges No. 72/65 Straube buildingscience.com 18 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Adding studspace insulation is not helpful! Impact of Insulating Sheathing insulating sheathing exterior sheathing stud depth steel stud wall R cc R avg (steel framming ) 16.2 30 R cc Ravg (steel framming ) 27.1 15 10 R-value (ft 2.o F. hr/btu) 5 12.1 6.6 55% Add R 2 Get R 0.6 14.0 7.2 51 % Add R 2 Get R 0.5 7.7 48% 25 20 R-value (ft 2.o F. hr/btu) 15 10 5 12.1 6.6 55% Buy R5 Get R6 14.6 9.9 68% Buy R10 Get R12.2 17.1 12.6 74% 19.6 15.3 78 % 22.1 17.8 81% 24.6 20.4 83% 22.9 85% interior sheathing stud spacing 0 2x4@16" R-11 batt 2x4@16" R-13 batt 2x4@16" R-15 batt Wall Construction (Stud Size and Spacing and Cavity Insulation R -value ) From : Bombino and Burnett, Pennsylvania Housing Research Center Insulation and Thermal Bridges No. 73/65 0 0.0 2.5 5.0 7.5 10.0 12.5 15.0 Exterior Insulating Sheathing R -value (ft 2.o F. hr/btu) From : Bombino and Burnett, Pennsylvania Housing Research Center Insulation and Thermal Bridges No. 74/65 Thermal Bridging: Common Problems Insulation and Thermal Bridges No. 75/65 Insulation and Thermal Bridges No. 76/65 Straube buildingscience.com 19 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 2008 Insulation and Thermal Bridges No. 77/65 2008 Insulation and Thermal Bridges No. 78/65 Cold surfaces where R<5 69 F High RH / Low R 50 F 32 F /15 F /75 F 2008 Insulation and Thermal Bridges No. 79/65 2008 Insulation and Thermal Bridges No. 80/65 Straube buildingscience.com 20 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Thermal Bridge Examples Balcony, etc Exposed slab edge, Solving Thermal Bridging Exterior insulation can solve most thermal bridges Inside works, but hard to cover structural penetrations Lower interior RH to stop condensation 2008 Insulation and Thermal Bridges No. 81/65 Insulation and Thermal Bridges No. 82/65 All on the exterior 2008 Insulation and Thermal Bridges No. 83/65 2008 Insulation and Thermal Bridges No. 84/65 Straube buildingscience.com 21 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Small metal clips dramatically reduce thermal bridging 2008 Insulation and Thermal Bridges No. 86/65 Balconies Insulation and Thermal Bridges No. 87/65 2008 Insulation and Thermal Bridges No. 88/65 Straube buildingscience.com 22 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Insulation and Thermal Bridges No. 89/65 2008 Insulation and Thermal Bridges No. 90/65 Precast balcony supported on knife edge supports to limit thermal losses 2008 Insulation and Thermal Bridges No. 91/65 2008 Insulation and Thermal Bridges No. 92/65 Straube buildingscience.com 23 of 24

Fundamentals Thermal Control: Insulation & Thermal Bridges May 29-30, 2013 Summary: Heat flow control A continuous layer of only R5-10 is key Exterior is easiest to get continuous Should provide much more for energy efficiency Heat flow control is not just about R-value! Control of airflow Thermal bridging must be managed Thermal mass can play a role Solar Gain can dominate Window area, shading, low SHGC windows Overhangs, light colors for walls and roofs Insulation and Thermal Bridges No. 93/65 Straube buildingscience.com 24 of 24