Secugrid & Combigrid Geogrids Installation Guide Installation Guidelines: Base Reinforcement Applications

Similar documents
BENTOMAT CL GEOSYNTHETIC CLAY LINER SPECIFICATION GUIDELINES

SECTION 20 INDEX PAVING FABRIC 1. SCOPE OF WORK MATERIAL REQUIREMENTS CONSTRUCTION AND INSTALLATION REQUIREMENTS...

Tensar TriAx Geogrids Design Site Assistance

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

TENSAR TRIAX (TX) Geogrid INSTALLATION GUIDE

CITY OF FARGO SPECIFICATIONS AGGREGATE BASES

StormTech Construction Guide

Bentofix INNOVATION & QUALITY QUALITY

INSTALLATION GUIDELINES FOR MIRAFI FG & FGC

Brock White Canada Attn: Mr Nigel J. Lilley Street Edmonton AB T5V 1L8 Canada

TION GUIDE LLA A T INS

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 863 REINFORCED SOIL SLOPES. October 19, 2012

R-TANK SPECIFICATIONS

The Bentonite Construction Waterproofing Manual

ITEM 6 CONCRETE CURBS, GUTTERS, AND SIDEWALKS

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

ICC-ES Evaluation Report Issued July 1, 2011 This report is subject to renewal in one year.

BASE CONSTRUCTION MATERIALS A Aggregate

2. Pavement Materials: Consist of flexible or rigid pavements, typically HMA or PCC, respectively, or a composite of the two.

Municipality of Waterville Public Sidewalk Repair Policy

Click on image to enlarge.

Installation Guidelines BENTOMAT CLAYMAX. Geosynthetic Clay Liners LINING TECHNOLOGIES

BENTOMAT ST GEOSYNTHETIC CLAY LINER GUIDE SPECIFICATION

ITEM 275 PORTLAND CEMENT TREATED MATERIALS (ROAD MIXED)

SECTION 3: SUB BASE AND BASE COURSES

SEGMENTAL BLOCK RETAINING WALLS. Comply with Division 1 - General Provisions and Covenants, as well as the following:

GEOWEB load support OVERVIEW

BIO-AQUIFER STORM SYSTEM

Low Maintenance Slabs Supports Are Needed for Long-Term Performance of Welded Wire Reinforcement In Slabs-On-Grade

INDEX FOR SPECIFICATIONS FOR REMOVING CULVERTS AND PLACING CULVERTS SCOPE... 1

Application Guidelines

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK

SECTION RIPRAP, BOULDERS, AND BEDDING

SECTION A1 EXCAVATION AND BACKFILL GENERAL

A. Texas Department of Transportation 2004 Standard Specifications for Construction and Maintenance of Highways, Streets and Bridges (TxDOT).

Section 508. CHIP SEALS Description. Prepare the surface and apply the specified single chip seal, double chip seal or shoulder chip seal.

SECTION 26 - COLD PLANE ASPHALT CONCRETE PAVEMENT TABLE OF CONTENTS

CONSTRUCTION STANDARDS SECTION CS 3 TRENCH FOUNDATION, BEDDING AND BACKFILL

SECTION BITUMINOUS CONCRETE PAVEMENT

SYNTHETIC GRASS INDOOR SURFACE SPECIFICATIONS: K9GRASS LITE

CETCO-VOLCLAY CG-50 SPECIFICATION GUIDELINES MIX IN PLACE

PART 1 GENERAL REQUIREMENTS

AGRU GEOCLAY TM GEOSYNTHETIC CLAY LINER INSTALLATION MANUAL

Construction Specification for Utility Adjustments

abstract The grains have to be kept in place. Shortcut just mechanical law. actio equal reactio (Third law of Sir Isaac Newton, 1697)

Section 25 Aggregate Subbase

ITEM 458 WATERPROOFING FOR STRUCTURES

AEC Premier Straw Double Net Quick Mow EROSION CONTROL BLANKET SPECIFICATION

Impact Protection Slabs and Sports Pavement Slabs

SECTION UNCLASSIFIED EXCAVATION AND GRADING

Prepaving Conferences

TotTurf EPDM Product Specification

SECTION 1 STALOK FIBER FOR TURF PARKING / EVENT STAGING AND FIRE LANES

VIRGINIA DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LATEX MODIFIED EMULSION TREATMENT (MICRO-SURFACING)

Redi Rock Specification and Installation Manual

SECTION 2200 PAVING CITY OF BLUE SPRINGS, MISSOURI CONSTRUCTION SPECIFICATIONS

Installation Guidelines PETROMAT PAVING FABRIC

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

CONSTRUCTION SPECIFICATION FOR SINGLE AND DOUBLE SURFACE TREATMENT

550 Surface Treatments

Section 409. Chip and Fog Seals

Recyclex TRM TURF REINFORCEMENT MAT SPECIFICATION

Cement Stabilized Soil (CSS) (Portland cement)

INSTALLATION GUIDELINES PETROMAT PAVING FABRIC

GEOSYNTHETIC-REINFORCED PAVEMENT SYSTEM : TESTING & DESIGN

SYNTHETIC GRASS INSTALLATION GUIDE SOFT AND HARD SURFACE

Special Provision No. 305S02 January 2016

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

Pavement Design. TTP Orientation Seminar 2011

A. Texas Department Transportation 2004 Standard Specifications for Construction of Highways, Streets and Bridges (TxDOT):

Curlex High Velocity EROSION CONTROL BLANKET SPECIFICATION

B. Subsurface data is available from the Owner. Contractor is urged to carefully analyze the site conditions.

SECTION REINFORCING STEEL

Design and Installation Guidelines for Retaining Walls. 1 P age. Geo Products, LLC 8615 Golden Spike Lane Houston, TX Phone:

CHAPTER 3 CONSTRUCTION AND TESTING OF SUBGRADE

BMP 6.4.4: Infiltration Trench

MIDLAND COUNTY ROAD COMMISSION

Curlex II EROSION CONTROL BLANKET SPECIFICATION

Stanford University Facilities Design Guidelines SECTION SEAL COATS. C. Section : Traffic Striping and Pavement Markings

Extraction and Sieve Analysis ( µm minus) Forming Marshall Specimens, Field Method

Best Practices for Building High-Performance Resource Roads. Road Drainage. Developed by: The Roads and Infrastructure Group

Asphalt Rubber Chip Sealing DRAFT MAINTENANCE SPECIFICATION. March 22, 2007

DIVISION 32 EXTERIOR IMPROVMENTS

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

SITE SERVICES GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013

ENGINEERED SOLUTIONS. Safety Instructions for Unloading and Handling Contech Corrugated Metal Pipe

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 5 REINFORCING STEEL. 5.1 General Certification Fabrication...

INTERLOCKING CONCRETE PAVERS SECTION 02780

Section 505. CHIP SEALS

507 SLURRY SEAL AND MICRO-SURFACING 1 of 8 CATEGORY 500 PAVING SECTION 507 SLURRY SEAL SECTION 507 SLURRY SEAL AND MICRO-SURFACING

BSS 50 Synthetic Track Surfacing System Specifications

Construction Procedures

SPECIFICATIONS FOR STREET CONSTRUCTION WITHIN THE TOWN OF PLAINVILLE

4-07 Asphalt Treated Permeable Base (ATPB)

RAUPEX SPEED SYSTEM Installation Guide

PRODUCT DATA SHEET SikaProof Bentonite

h Installation Manual

City of Brandon Division 2 Standard Construction Specifications Section January 2000 Page 1 of 10 SOIL CEMENT BASE COURSE PART 1 GENERAL

BSS 200 Synthetic Track Surfacing System System Specifications

Transcription:

Secugrid & Combigrid Geogrids Installation Guide Installation Guidelines: Base Reinforcement Applications NAUE GmbH & Co. KG 2005 by NAUE GmbH & Co. KG, Espelkamp-Fiestel, Germany. All rights reserved. The information contained herein is the best to our knowledge, true and accurate. There is no implied or expressed warranty. Secugrid is a registered trademark of NAUE GmbH & Co. KG; Germany Tel. 05743/41-0. Fax 05743/41-240. info@naue.com. www.naue.com. www.secugrid.com Page 1 from 5

TABLE OF CONTENTS 1. Scope 2. Applications 3. Receipt, storage and handling 4. Secugrid Installation 5. Fill placement and compaction control 1.) SCOPE This installation guide is valid for all Secugrid /Combigrid geogrids used in base reinforcement applications. It details the receipt, storage and handling, installation of geogrid and fill placement. 2.) APPLICATIONS This guide is appropriate for geogrid installation in base reinforcement applications, to include: - Unpaved roads and/or roads subsequently paved - Parking areas, unpaved and/or subsequently paved - Area stabilization for laydown yards, and multidirectional traffic areas - Reinforcement over subsidence prone areas - Similar applications 3.) RECEIPT, STORAGE AND HANDLING Geogrids received shall be verified as being the type, grade or designation required for the project, as defined by the project documents. Material shall be clearly marked, and in good condition before acceptance by the installation contractor. Tel. 05743/41-0. Fax 05743/41-240. info@naue.com. www.naue.com. www.secugrid.com Page 2 from 5

Geogrids are transported and stored in rolls, and may be stacked on top of each other, but no more than seven rolls in height. If stored on the ground, a tarpaulin shall be laid first to protect rolls from collecting dirt from site. A tarpaulin for protection from the elements must cover material stored onsite for a period exceeding two months. Geogrids may be installed either manually or by use of mechanized equipment. Edges of the geogrid rolls can be sharp, so gloves may be used during hand carrying and placement to prevent injury. Mechanized equipment may be used providing the said installation equipment does not damage the geogrid during this process. 4.) SECUGRID INSTALLATION Ground surface shall be prepared prior to placement, providing a level and uniform ground surface, with appropriate clearing and grubbing performed to accomplish this. Additional preparation, as outlined in the project documents may be required. Geogrid shall be placed in the location and orientation specified in the project plans and specifications. Geogrid shall be laid flat and smooth directly on the prepared subgrade. All wrinkles and folds shall be removed. When required, geogrid may be pretensioned to eliminate slack. Geogrid shall be overlapped a minimum of 300 mm in both adjacent and longitudinal directions, or joined as specified in the project plans. Soft subgrade installations may require a greater overlap, or joining of adjacent rolls using cable ties or other suitable device to maintain the geogrid location and orientation during fill placement. Consult project plans and specifications for more instructions in this regard. Tel. 05743/41-0. Fax 05743/41-240. info@naue.com. www.naue.com. www.secugrid.com Page 3 from 5

Cutting of Secugrid (for example with an electric powered rotating disc) Repair of damage areas 5.) FILL PLACEMENT AND COMPACTION CONTROL Prior to fill placement the geogrid shall be inspected by the certified inspector, to make sure it is placed in the proper location, and has not been damaged during this installation. Damaged geogrid, as determined by the engineer shall be repaired immediately, either by replacement or by patching to suitably cover the damaged area. Consult engineer for additional requirements. Tel. 05743/41-0. Fax 05743/41-240. info@naue.com. www.naue.com. www.secugrid.com Page 4 from 5

Typically construction vehicles are not allowed to traffic directly on the geogrid. The subbase or base course shall be placed so a minimum of 200 mm is in place before trafficking may occur. On firm subgrades rubber tired vehicles may be allowed to traverse directly on the geogrid, providing no turning or sudden stops are allowed, and slow speeds are maintained. Contractor shall obtain permission from the responsible engineer before this may occur. Any ruts occurring during fill placement shall be immediately filled in. Typically granular fill is used for base reinforcement applications. In all cases fill used shall be as required in the specifications, and shall be placed and compacted accordingly. If guidance is not provided, compaction shall be carried out according to the minimum standards set forth by appropriate local guidelines. Tel. 05743/41-0. Fax 05743/41-240. info@naue.com. www.naue.com. www.secugrid.com Page 5 from 5