Ruby Installation Manual

Similar documents
Ser vo Drive Commissioning Instruction

BMC-7 CONTROLLER MANUAL

PDM16 & PDM32 User Manual

RT8725. Single-Phase BLDC Fan Driver IC. Features. General Description. Applications

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

MEGATORQUE MOTOR SYSTEM User s Manual

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

Sensor unit MC2 for toxic gases and oxygen with analog output

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

MD Power Supply -48Vdc +Bias Tee

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Owner's manual SAX-1200D SAZ-1500D SAZ-2500D SAZ-3500D

Mechatronics Courses by School Period

Wash Down Duty Non-Contact Sensor

RT mA, Ultra-Low Noise, Ultra-Fast CMOS LDO Regulator. Features. General Description. Applications. Ordering Information RT9193-

Food & Beverage Portfolio

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Single Pulse Resistance Welder Instruction Pamphlet CD125SP High Accuracy CD Welder

Model 5511 & 6611 Scale Controller User s Manual Version 2.66 January Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS

Mar11 Rev B

The I-7531 CAN Repeater

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF

Technological Training Programs

Supplemental Instruction Manual

Datenblatt Touch Controller 4/5 Draht Resistiv TC-R4/5-232+USB

SINAMICS S120 Firmware Version V4.8

Features. Low Flow Dual Duct VAV/CV with QVM. Application Data Sheet

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Model: LI55 DataView Level Controller Instruction Manual

Taking the LED Pick and Place Challenge

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

7700 TEST KIT OPERATIONS MANUAL

2.8 ( Access Level 3-4)

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

Three-tank System Exercise

Theft Resistant Shopping Cart Project Proposal

electroplating DC power supply type SIFCO PROCESS POWER PACK 1028

SELECTION GUIDE Appearance Sensing distance Operation Mode Connector Shape example (M8) Outer diameter (Ferrous material only) Wiring Output Output no

Technical System Catalogue Modular PDU (PSM)

Table of Contents. Installation 2-10 Leveler legs... 2 Controller... 4 Dip-switch Configurations. 5 Wire Harness Installation.. 7

July P Wide Format Stacker User Guide

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

Standard of Practice - Campus Electrical Distribution System

SOLAR WATER PUMP KIT MODEL: SIS-10HP

Bonded Neo Magnetization Guide

SIWAREX FTC-B Weighing Module for Belt Scales Set-up of SIWAREX FTC with SIWATOOL FTC_B

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

ALLIED ELECTRONICS, INC STATION SITE CONTROLLER (SSC) Installation and Start Up Guide. ARCO / ANDI to Wayne PIB

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

Scanning Devices Label Counting Table Operations Manual

Digital Self Contained Weighing Module

15 Pin DSUB - MALE 15 Pin DSUB - FEMALE 9 Pin DSUB - MALE 9 Pin DSUB - FEMALE

Oxygen Sensor QGO20...

2000 User/ Installer Guide

Melt tension measurement (Haul-Off)

PD662 Loop-Powered Meter Instruction Manual

product specifications e

Equipment Requirements SBC Local Exchange Carriers May 2001 NETWORK EQUIPMENT POWER, GROUNDING, ENVIRONMENTAL, AND PHYSICAL DESIGN REQUIREMENTS

DIGITAL NITROUS PROCESSOR Installation and Instruction Manual

RapID Raw Materials Verification System

Y-HEAT THERMAL MANAGEMENT SYSTEM FOR OVEN, FURNACE, VACUUM FURNACE, AND CRYOGENIC CHAMBER SYSTEMS. Product Overview and Specifications

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

ARC STUD WELDING SYSTEMS

PERFORMANCE OF VAISALA OZONE INTERFACE BOARD OIF411

MERIGAUGE MODEL 3900 OPERATING INSTRUCTIONS

LD2985. Very low drop and low noise voltage regulator with inhibit function. Features. Description

Pallet Safe: Installation Supplement Rev

ELVORON LU/LA ELEVATOR

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Electrical Networks Principles and Performance

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

Customer Interface Publication: KCOM (Hull) CIP003

Quick Guide. CSN950 MultiHead Dimensioner _v2d_MAN_QG_CSN950MH_EN

TF20 Tray Feeder. Instruction Manual. for JEDEC and IEC Standard Trays

MPK 411 CONTROL SYSTEM

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

kva single and parallel UPS Systems User s and Installation Manual

Data Bus Connector and Terminator Requirements Document DB-1001-A. Revision C

ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)

ACT. Summary. 1 Introduction. 2 Synoptic. 3 Technical characteristics. 4 Part-numbering system. 5 Arrangements. 6 Receptacles. 7 Plug / Panel seal

DVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons

WP200e Wallbox to CD Changer Adapter

Welding Force Calibration Transmitter

alpha single screw extruders

SM-220-MP SHOCK TEST MACHINE. Halfsine. Sawtooth. Squarewave

FAST SPOTTER WT-FS-5.0

IPC-SMEMA Mechanical Equipment Interface Standard IPC-SMEMA Supersedes SMEMA 1.2 ASSOCIATION CONNECTING ELECTRONICS INDUSTRIES

Design Qualification Test Report SMS/TMS SMS L-D/TMS L-D

Multi-Purpose Mechanized Welding Carriage

DESIGN VERIFICATION TEST REPORT ERCDA SS-TD-TU. Mated with ERF L-DV-L

nicrom e l e c t r o n i c

Powerware 9120 UPS. Date: Issued By: Product Affected May 27, 2003 Gary Bankay PowerFlex 7000 MV Drive

Model PM-616 Two-Color Pyrometer Operator s Manual Revision 1.2

Transcription:

Ruby Installation Manual Version 02 www.servodynamics.com

Introduction Table of Contents: 1 2 2.1 2.2 2.3 INTRODUCTION ------------------------------------------------------------------------------------- 5 TECHNICAL DATA AND SPECS ----------------------------------------------------------------6 Ruby Model Numbering -------------------------------------------------------------------------------------------------- 6 Ruby Technical Data ------------------------------------------------------------------------------------------------------- 6 Ruby Mechanical Specifications ----------------------------------------------------------------------------------------- 7 3 3.1 3.2 MECHANICAL INSTALLATION ----------------------------------------------------------------- 8 Ruby 2 and 4 Amp ---------------------------------------------------------------------------------------------------- 8 Ruby 8 and 12 Amp -------------------------------------------------------------------------------------------------- 9 4 4.1 ELECTRICAL INSTALLATION ----------------------------------------------------------------- 10 Components of a Servo System ---------------------------------------------------------------------------------------- 10 4.2 Electrical Supply Connection ------------------------------------------------------------------------------------------ 11 4.2.1 Bus Supply P1 (fusing provided by the user) ----------------------------------------------------------------- 11 4.2.1.1 Three Phase --------------------------------------------------------------------------------------------------- 11 4.2.1.2 Single Phase -------------------------------------------------------------------------------------------------- 12 4.2.2 24V Auxiliary Supply P4 (supplied by User) ----------------------------------------------------------------- 12 4.2.3 Regen Circuit P2 -------------------------------------------------------------------------------------------------- 13 4.2.3.1 Functional Description -------------------------------------------------------------------------------------- 13 4.2.3.1.1 Regen in individual drives ------------------------------------------------------------------------------ 13 4.2.3.1.2 Multiple drives coupled through DC bus link -------------------------------------------------------- 13 4.2.3.2 Connection Diagram ---------------------------------------------------------------------------------------- 14 4.2.4 Servomotor Connection P3 -------------------------------------------------------------------------------------- 15 4.2.4.1 P3 Connection for Brushless Servomotors without Brake ------------------------------------------- 15 4.2.4.2 P3 Connection for Brush Servomotors without Brake ----------------------------------------------- 16 4.2.4.3 P3 Connection for Brushless Servomotors with Brake ----------------------------------------------- 17 4.2.4.4 P3 Connection for Brush Servomotors with Brake --------------------------------------------------- 18 4.2.5 Encoder Feedback from Servomotor S4 ----------------------------------------------------------------------- 19 4.2.6 I/O Connection S1 ------------------------------------------------------------------------------------------------ 21 4.2.6.1 Analog Command Signal ----------------------------------------------------------------------------------- 22 4.2.6.2 Programmable Analog Outputs ---------------------------------------------------------------------------- 23 4.2.6.3 Digital Inputs ------------------------------------------------------------------------------------------------- 23 4.2.6.4 Enable --------------------------------------------------------------------------------------------------------- 23 4.2.6.5 Travel Limit Inputs ------------------------------------------------------------------------------------------ 23 4.2.6.6 Digital Outputs ----------------------------------------------------------------------------------------------- 24 4.2.6.7 Digital Output 1 Fault ------------------------------------------------------------------------------------- 24 4.2.6.8 Digital Output 2 Ready ----------------------------------------------------------------------------------- 24 4.2.6.9 VDC Output -------------------------------------------------------------------------------------------------- 24 4.2.6.10 Grounding ---------------------------------------------------------------------------------------------------- 24 4.2.6.10.1 Digital Ground ------------------------------------------------------------------------------------------- 24 4.2.6.10.2 Analog Ground ------------------------------------------------------------------------------------------ 24 4.2.7 Special Function I/O Connection S3 --------------------------------------------------------------------------- 25 8/27/2008 2

Introduction 4.2.7.1 Position Mode ------------------------------------------------------------------------------------------------ 26 4.2.7.2 Master/Slave -------------------------------------------------------------------------------------------------- 26 4.2.7.3 2 nd Encoder Input -------------------------------------------------------------------------------------------- 26 4.2.8 S2 USB Interface to PC ------------------------------------------------------------------------------------------ 27 4.2.9 Drive Status LED --------------------------------------------------------------------------------------------------- 27 8/27/2008 3

Introduction Table of Figures: Figure 1 Ruby 2 and 4 Amp Mechanical Dimensions 8 Figure 2 - Ruby 8 and 12 Amp Mechanical Dimension 9 Figure 3 - Drive Components 10 Figure 4 - Three Phase Input Connection 11 Figure 5 - P1 12 Figure 6 P4 12 Figure 7 P2 Connector 14 Figure 8 Brushless Motor Power 15 Figure 9 - P3 Connection to the Brushless Motor without Brake 15 Figure 10 Brush Motor Power 16 Figure 11 - P3 Connection to the Brush Motor without Brake 16 Figure 12 P3 Connection to the Brushless Motor with Brake 17 Figure 13 P3 Connection to the Brush Motor with Brake 18 Figure 14 S4 -Encoder I/O Connector 19 Figure 15 S1-Control I/O pins 21 Figure 16 Analog Command Signals 22 Figure 17 - Digital Input Stage 23 Figure 18 - Digital Outputs 24 Figure 19 - S3 Connection 25 Figure 20 - USB Connector 27 Table of Tables: Table 1 24VDC pin description 12 Table 2 Auxiliary input current 12 Table 3 P2 Connection 14 Table 4 Brushless Motor power connector pinout 15 Table 5 Brush Motor power connector pinout 16 Table 6 Brushless Motor power/brake connector pinout 17 Table 7 Brush Motor power/brake connector pinout 18 Table 8 Encoder I/O connector pinout 19 Table 9 Pinout of Control I/O Connector S1 21 Table 10 Torque Direction 22 Table 11 - S3 Connection Pinout 25 Table 12 - USB Pin Description 27 8/27/2008 4

Introduction 1 Introduction This servo drive is designed to meet the simplest and most critical applications. The performance is delivered through a digital signal processor (DSP) and external high resolution A/D s and D/A s. The construction is designed to maintain the lowest level of radiation emission and electrical noise. This servo drive can run brushless servomotors, brush servomotors and voice coil motors. The packaging is a compact bookshelf mounting design with maximum current output capabilities. The design is CE, RoHS and UL 508C compliant. This design optimizes the packaging keeping it as small as possible but delivering maximum power. The servo drive operates in torque, velocity or position mode. The position mode has added features such as, electronic gearing and 2 nd encoder feedback. The commutation is field-oriented sinusoidal delivering the highest performance of motion control. Feedback devices can be incremental encoder, resolver or sin/cos encoder. The drive outputs a TTL differential signal that can be programmed to different frequencies not to exceed 4 times the resolution of the primary feedback device. The servo drive has a failsafe brake output with programmable on/off response times. An internal regeneration circuit handles most situations, however when necessary an external regen component can be added and multiple servo drives can be connected together to share regeneration. The servo drive requires a 24 VDC or VAC input for supplying the logic power. This is mandatory for isolating the drive output power from the drive logic power for controlled shut downs. The servo drive inputs consist of enable, command signal, travel limits (positive and negative) and TTL inputs (pulse/direction, electronic gearing). The servo drive has 2 programmable 16 bit analog outputs. These are typically used for monitoring velocity or torque output, but can also be used for control feedback. There are 2 digital outputs, one for drive ready and one for fault condition. The fault condition can trip a hard relay which can be powered by the servo drive. An LED is visible from the front of the servo drive for preliminary fault analysis. For complete analysis the servo drive must be connected to a PC. The servo drives is fully protected against irregular operating conditions and miss wiring. Commissioning software assists the user in installation and tuning the servo drive. A PC is connected to the servo drive through a USB connection. The commissioning software must be installed on the PC. Simple instructions guide the user through setup and tuning. An oscilloscope in the commissioning software is provided for the advanced user. 8/27/2008 5

Technical Data and Specs 2 Technical Data and Specs 2.1 Ruby Model Numbering 2.2 Ruby Technical Data Motor Operating Modes Series 200 300 Model 202 204 208 212 302 304 308 312 Brush, Brushless and Linear Current, Velocity, Position, Gearing, Dual Loop Supply Voltage (VAC) 80-130 (1 ) 190-260 (1,3 ) Continuous Output Current (Amp) Peak Output Current (Amp), Max 3 Sec 2 4 8 12 2 4 8 12 6 12 24 36 6 12 24 36 DC Bus Voltage (VDC) 112-182 266-364 Current Loop Bandwidth (Hz) 3300 Velocity Loop Bandwidth (Hz) Digital In, Digital Out, Analog In, Analog Out Communications 350 4, 3, 2, 2 USB 2.0 Mini-B-Receptacle, Current Rating 1 A, Voltage Rating 5 VAC, Transmission speeds up to 480 Mbps 8/27/2008 6

Technical Data and Specs 2.3 Ruby Mechanical Specifications Series 200 300 Model 202 204 208 212 302 304 308 312 Width mm(in) Height mm(in) Depth mm(in) Weigh kg(lb) 65 (2.56) 86 (3.4) 65 (2.56) 86 (3.4) 187 (7.35) 113 (4.45) 1.02 (2.25) 1.40 (3.10) 8/27/2008 7

Mechanical Installation 3 Mechanical Installation The important elements to mechanical installation are providing adequate cooling, a non-corrosive environment, and grounding. Four mounting slots are provided as shown below. 3.1 Ruby 2 and 4 Amp Units in Inch (mm) Figure 1 Ruby 2 and 4 Amp Mechanical Dimensions 8/27/2008 8

Mechanical Installation 3.2 Ruby 8 and 12 Amp Units in Inch (mm) Figure 2 - Ruby 8 and 12 Amp Mechanical Dimension 8/27/2008 9

4 Electrical Installation 4.1 Components of a Servo System The servo drive and servomotor should have comparable current and voltage ratings to protect the servomotor. Fusing is the responsibility of the user. The power and control cables must be routed separately to protect against electrical noise as required by EMC regulations. Shields on all cables must be grounded on one end consistent from the controller to the servomotor and regen resisters if added. Cabling is the responsibility of the user. The conductor cross-sections must meet EN 60204. It is recommended to use 22 awg, twisted pairs, and shielded cabling for the feedback from the servomotor to the servo drive. Figure 3 - Drive Components Note: S1, S2, S3 and S4 mating connectors are supplied by the customer. 8/27/2008 10

4.2 Electrical Supply Connection 4.2.1 Bus Supply P1 (fusing provided by the user) AC Voltage Supply 4.2.1.1 Three Phase Input voltage range: 190-260V @ 50/60 Hz All ground leads must lead to a central ground point. Failure to do so may result in ground loops. Figure 4 - Three Phase Input Connection The protective earth (PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth. It also ensures that in the case of an insulation fault, a high fault current flows, which will trigger an overcurrent protection device (fuse) that disconnects the power supply. Failure to connect the PE could result in electrical shock. The PE wire needs to be thick enough to handle the current in case of an insulation fault. It is a good practice to connect the shield on just one side. Connecting on both ends could cause a potential difference that may result in current flow in the shield. 8/27/2008 11

4.2.1.2 Single Phase Input Voltage range: 80V-130V @ 50/60Hz. L1 phase must be connected through an external fuse. Figure 5 - P1 4.2.2 24V Auxiliary Supply P4 (supplied by User) 24 VDC or 24VAC input if not powering servomotor brake Figure 6 P4 Pin Description 1 24VDC or 24VAC Note 2 GND Table 1 24VDC pin description Input Voltage (VDC) Input Current (ma) 12 400 24 200 30 160 Table 2 Auxiliary input current Note: 24VAC may be used only when the brake is not present. 8/27/2008 12

4.2.3 Regen Circuit P2 4.2.3.1 Functional Description 4.2.3.1.1 Regen in individual drives In some applications where the servomotor decelerates with a lot of inertia, or is running at high speed and commanded to stop, the system kinetic energy that is being regenerated is greater than the losses in the system. This means that electrical energy is pumped back into the main bus capacitors and may cause them to charge up to a voltage level beyond the capability of the drive and the capacitors. The drive is protected against this over-voltage condition. The drive has a shunt regulator connected to the DC bus capacitor. The shunt regulator turns on at Shunt Regulator Trip and shunts excessive voltage through a voltage-dropping resistor mounted on the heat sink. An external braking resistor may be used for applications in which the servo motor has to be braked frequently and the internal braking resistor cannot dissipate the excess braking energy. 4.2.3.1.2 Multiple drives coupled through DC bus link In multiple drive applications, the drives are set up to allow their DC link to be tied to the DC links of other drives so that the regenerative power from one motor can be used as the motor power for another. 8/27/2008 13

4.2.3.2 Connection Diagram Figure 7 P2 Connector Pin Name External Regen Resistor *Internal Regen Resistor 1 RE X Ohm resistor to RB Not Connected 2 RI Not Connected Connected to RB 3 RB X Ohm resistor to RE Connected to RI 4 DC- Not Connected Not Connected Illustration R Table 3 P2 Connection Jumper *Internal Regen Resistor is 30 W at 25 ohms. 8/27/2008 14

4.2.4 Servomotor Connection P3 4.2.4.1 P3 Connection for Brushless Servomotors without Brake Figure 8 Brushless Motor Power Pin Name Description 6 BR- Not Connected 5 BR+ Not Connected 4 PE Protective Earth 3 W Motor Phase W 2 V Motor Phase V 1 U Motor Phase U Table 4 Brushless Motor power connector pinout Figure 9 - P3 Connection to the Brushless Motor without Brake The protective earth (PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth. It also ensures that in the case of an insulation fault, a high fault current flows, which will trigger an overcurrent protection device (fuse) that disconnects the power supply. Failure to connect the PE could result in electrical shock. It is required to connect the shield on one side, and leave it opens on the other side. Connecting on both ends could cause a potential difference that may result in current flow in the shield. 8/27/2008 15

4.2.4.2 P3 Connection for Brush Servomotors without Brake Figure 10 Brush Motor Power Pin Name Description 6 BR- Not Connected 5 BR+ Not Connected 4 PE Protective Earth 3 NC Not Connected 2 - Motor - 1 + Motor + Table 5 Brush Motor power connector pinout Figure 11 - P3 Connection to the Brush Motor without Brake The protective earth (PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth. It also ensures that in the case of an insulation fault, a high fault current flows, which will trigger an overcurrent protection device (fuse) that disconnects the power supply. Failure to connect the PE could result in electrical shock. It is required to connect the shield on one side, and leave it opens on the other side. Connecting on both ends could cause a potential difference that may result in current flow in the shield. 8/27/2008 16

4.2.4.3 P3 Connection for Brushless Servomotors with Brake Ruby is compatible only with 24V brakes. The Engage and the Disengage time may be set in the commissioning software (Motor properties page). Figure 12 P3 Connection to the Brushless Motor with Brake Pin Name Description 6 BR- Brake - 5 BR+ Brake + 4 PE Protective Earth 3 W Motor Phase W 2 V Motor Phase V 1 U Motor Phase U Table 6 Brushless Motor power/brake connector pinout The protective earth (PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth. It also ensures that in the case of an insulation fault, a high fault current flows, which will trigger an over current protection device (fuse) that disconnects the power supply. It is required to connect the shield on one side, and leave it opens on the other side. Connecting on both ends could cause a potential difference that may result in current flow in the shield. 8/27/2008 17

4.2.4.4 P3 Connection for Brush Servomotors with Brake Ruby is compatible only with 24V brakes. The Engage and the Disengage time may be set in the commissioning software (Motor properties page). Figure 13 P3 Connection to the Brush Motor with Brake Pin Name Description 6 BR- Brake - 5 BR+ Brake + 4 PE Protective Earth 3 NC Not Connected 2 - Motor - 1 + Motor + Table 7 Brush Motor power/brake connector pinout The protective earth (PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth. It also ensures that in the case of an insulation fault, a high fault current flows, which will trigger an over current protection device (fuse) that disconnects the power supply. It is required to connect the shield on one side, and leave it opens on the other side. Connecting on both ends could cause a potential difference that may result in current flow in the shield. 8/27/2008 18

4.2.5 Encoder Feedback from Servomotor S4 Figure 14 S4 -Encoder I/O Connector Pin Name Description 1 +5V +5V DC Encoder power 2 D_GND Digital Ground 3 A+ Encoder Input A+ 4 A- Encoder Input A- 5 B+ Encoder Input B+ 6 B- Encoder Input B- 7 I+ Encoder Input I+ 8 I- Encoder Input I- 9 HA+ Hall sensor Input A+ 10 HA- Hall sensor Input A- 11 HB+ Hall sensor Input B+ 12 HB- Hall sensor Input B- 13 HC+ Hall sensor Input C+ 14 HC- Hall sensor Input C- 15 TACH Tachometer feedback (with ref to A_GND) 16 A_GND Analog Ground 17 THERM1 Thermistor Input (PTC/NTC/Switch) 18 THERM2 Thermistor Input (PTC/NTC/Switch) 19 ENC_FBK Encoder feedback. See Note 20 +5VDC +5V DC 21 +5VDC +5V DC 22 D_GND Digital Ground 23 D_GND Digital Ground 24 D_GND Digital Ground 25 D_GND Digital Ground 26 D_GND Digital Ground Table 8 Encoder I/O connector pinout Note: Pin 19 must be jumped to digital ground if the encoder is not installed or the ENC_FBK signal is not used to identify an encoder feedback. 8/27/2008 19

The encoder inputs A and B provide incremental motor position information, and the input is a reference position marker to zero the position. Channels A and B are 90 degrees apart and Channel I is typically a small width pulse that marks the position of the shaft as zero when asserted. The Hall signals are differential inputs, used for speed and coarse position feedback. There are 3 hall inputs - one signal for each motor phase. All signals need to be connected in reference to the Digital ground. The Ruby accepts 5V differential TTL encoder signals. Single-ended or open-collector type hall signals may be used by connecting the positive hall signals to the respective positive hall inputs, and pulling up the negative hall signals to 5V through 475 Ohms resistor. Frequency limit for encoder channels A & B is 15MHz. Note: The mating connector to S4 is DB 26 pins shell size 2 male connector and is provided by the customer. 8/27/2008 20

4.2.6 I/O Connection S1 Figure 15 S1-Control I/O pins Pin Name Description 1 REF+ + Command Input (ref. to A_Gnd) 2 REF- - Command Input (ref. to A_Gnd) 3 A_GND Analog Ground (for single-ended command input) 4 AO_1 Programmable analog output 1 ( ref to A_Gnd) 5 AO_2 Programmable analog output 2 (ref to A_Gnd) 6 A_GND Analog Ground 7 ENABLE Enable the amplifier (refer to I_Gnd) 8 Limit+ Limit Switch Positive (ref to I_Gnd) 9 Limit- Limit Switch Negative (ref to I_Gnd) 10 DO1/Fault Digital output 1 Amplifier Fault (ref to I_Gnd) 11 DO2/Ready Digital output 2 Ready (ref to I_Gnd) 12 I_GND Isolated Ground 13 I_GND Isolated Ground 14 I_GND Isolated Ground 15 24V 24V DC switch power (ref to I_Gnd) Table 9 Pinout of Control I/O Connector S1 Note: The command voltage input range is +/-10V. Note: The mating connector to S1 is DB 15 pins shell size 2 male connector and is provided by the customer. 8/27/2008 21

4.2.6.1 Analog Command Signal The Ruby accepts single or differential command input. Figures below illustrate the input stage. Figure 16 Analog Command Signals The recommended full-scale differential command input range is ± 10V. The offset voltage is the input value at which the output is zero. The deadband is the voltage range for which there is no output response. For example, if the deadband voltage is 100mV, then the drive treats any input up to 100mV as zero, and hence only outputs for input greater than 100mV. Deadband is useful in cases where the rotation due to noise needs to be minimized/eliminated. The offset and the deadband for the input voltage may be set in the commissioning software Analog I/O page. Using Autobalancing (in the Analog I/O page) in the commissioning software sets the offset automatically. The direction of the torque depends on the Velocity/Current command direction in the commissioning software as listed below. Vel/Dir Command Direction 0 1 Command Input Polarity Direction Positive Clockwise Negative Counter Clockwise Positive Counter Clockwise Negative Clockwise Table 10 Torque Direction 8/27/2008 22

4.2.6.2 Programmable Analog Outputs Ruby has two programmable analog outputs, which can be selected in the commissioning software. The outputs may be chosen to represent the following motor data: Motor Current Command Current Current Error (Motor current command current) Velocity Feedback Command Velocity Velocity Error (Velocity feedback command velocity) 4.2.6.3 Digital Inputs Illustrates the digital input stage. All the digital inputs are optically isolated. Figure 17 - Digital Input Stage Open Collector, 80 ma max 4.2.6.4 Enable The function of this signal is to enable/disable the drive. The enable signal has to be wired through an external switch. The enable input accepts voltage in the range of 4.5-24VDC. The enable input signal may be configured as active high or active low in the commissioning software. 4.2.6.5 Travel Limit Inputs The function of the Limit switches (LS+ and LS-) is to provide an inhibit signal. When either of the inputs is asserted, the motor faults out. When the motor is reenabled, it starts moving in the opposite direction (relative to the direction in which it was moving prior to the fault). These signals maybe configured as active high or active low in the commissioning software. 8/27/2008 23

4.2.6.6 Digital Outputs Ruby has two digital outputs Fault and Ready. Both outputs are open collector type and are fully isolated from rest of the circuits. This picture shows the output stage of the digital outputs. Digital output max voltage -- 30V Figure 18 - Digital Outputs 4.2.6.7 Digital Output 1 Fault This output is asserted when there is fault in the system. This may be configured as active high or active low in the commissioning software. 4.2.6.8 Digital Output 2 Ready This output is asserted when the system is enabled/ready. This maybe configured as active high or active low in the commissioning software. 4.2.6.9 VDC Output The 24 VDC output may be used to power the digital signals. 4.2.6.10 Grounding 4.2.6.10.1 Digital Ground Isolated Ground is used as reference ground for digital I/O. 4.2.6.10.2 Analog Ground Used as reference ground for analog I/O. 8/27/2008 24

4.2.7 Special Function I/O Connection S3 Figure 19 - S3 Connection Pin Name Function 1 +5V +5 VDC 2 D_GND Digital Ground 3 OUTA+ Encoder output A+ 4 OUTA- Encoder output A- 5 OUTB+ Encoder output B+ 6 OUTB- Encoder output B- 7 OUTC+ Encoder output C+ 8 OUTC- Encoder output C- 9 PULSE+ Pulse input + 10 PULSE- Pulse input - 11 DIR+ Direction + 12 DIR- Direction - 13 +5V +5V DC 14 D_GND Digital Ground 15 D_GND Digital Ground Table 11 - S3 Connection Pinout Note: The mating connector to S3 is DB 15 pins shell size 1 female connector and is provided by the customer. 8/27/2008 25

4.2.7.1 Position Mode The pulse input determines the distance moved and the pulse frequency determines the velocity. The direction of torque is determined by the Direction input. These inputs are optically isolated from rest of the circuit. Differential signals are recommended for these inputs since they result in better resolution. Pulse and direction input voltage range 5V Dif. Pulse frequency range - Scaling Direction - + CW and CCW 4.2.7.2 Master/Slave Ruby supports drive slaving from an external pulse input. Desired ratio is selected during commissioning. Connect the Encoder outputs A & B of the master drive to the pulse and direction input of the slave drive. This enables the slave drive to follow the master drive. 4.2.7.3 2 nd Encoder Input In cases where the drive is in position mode and the application requires high position resolution with minimum backlash, a second encoder can be installed on the load side. The encoder is fed into the Ruby for closing the position loop reducing backlash in the system. The pulse and direction inputs may optionally be used as the second encoder input. 8/27/2008 26

4.2.8 S2 USB Interface to PC The USB connector enables the user to connect the drive to the PC. The windows based program ServoVista is used to configure and tune the drive. Figure 20 - USB Connector Pin Description 1 VBUS 2 D- 3 D+ 4 Not Connected 5 GND Table 12 - USB Pin Description 4.2.9 Drive Status LED The LED in Ruby indicates the status of the drive. Here are the lists of the LED status with its respective description. LED Status Solid Orange Solid Green Solid Red Description Drive is powered on, and disabled Drive is enabled Drive is under fault 8/27/2008 27