Experts in Femtosecond Laser Technology. DermaInspect. Non-invasive multiphoton tomography of human skin

Similar documents
In vivo Drug Screening in Human Skin Using Femtosecond Laser Multiphoton Tomography

Simultaneous multi-color, multiphoton fluorophore excitation using dual-color fiber lasers

Review Article Multiphoton Laser Microscopy and Fluorescence Lifetime Imaging for the Evaluation of the Skin

High-throughput three-dimensional (3D) lithographic microfabrication in biomedical applications

CHEMOMETRICAL ANALYSIS OF ENDOMETRIAL TISSUE FLUORESCENCE SPECTRA

Picosecond Transient Absorption Spectroscopy System. picotas

Confocal Microscopy of Electronic Devices. James Saczuk. Consumer Optical Electronics EE594 02/22/2000

Melanin Fluorescence Spectra by Step-wise Three Photon Excitation

Microendoscopes for imaging of the pancreas

Rice/TCU REU on Computational Neuroscience. Fundamentals of Molecular Imaging

TWO-PHOTON EXCITED FLUORESCENCE OF THE LENS FOR THE DIAGNOSIS OF PRESBYOPIA

Performance of the Micro Photon Devices PDM 50CT SPAD detector with PicoQuant TCSPC systems

SUPPLEMENTARY FIGURES

Confocal Microscopy Analyzes Cells

Monitoring and Optimizing the Lipopolysaccharides-plasmid DNA interaction by FLIM-FRET

DeltaPro. DeltaFlex FORENSICS PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Supplementary Information and Figures

Optical Observation - Hyperspectral Characterization of Nano-scale Materials In-situ

Towards Probing Skin Cancer using Endogenous Melanin Fluorescence

Spectral Separation of Multifluorescence Labels with the LSM 510 META

Fs- Using Ultrafast Lasers to Add New Functionality to Glass

CENTER FOR BRAIN EXPERIMENT

Two-photon 3-D mapping of ex vivo human skin endogenous fluorescence species based on fluorescence emission spectra

3D Laser Lithography in Biotechnology and Medical Technology

Confocal Microscopes. Evolution of Imaging

A simple introduction to multiphoton microscopy

Bioinstrumentation Light Sources Lasers or LEDs?

ABSTRACT 1. INTRODUCTION

ACTIVE DYNAMIC THERMOGRAPHY IN MAMMOGRAPHY

3 Pulsed laser ablation and etching of fused silica

Ultrasound and Photoacoustics

Compact multi-functional skin spectrometry set-up

Multiphoton Redox Ratio Imaging for Metabolic Monitoring In Vivo

Thermo Scientific GENESYS 10S Bio spectrophotometer

Supporting Information to Carbon Nanodots Towards a Comprehensive Understanding of their Photoluminescence

Toward High-speed Transcranial Photoacoustic Imaging using Compact Near-infrared Pulsed LED Illumination System

The Raman effect, discovered in 1928 by C.V. Raman in his

Flow Cytometry - The Essentials

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice.

Rapid Microtooling with laser based methods

Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

Diffraction Contrast Tomography. Unlocking Crystallographic Information from Laboratory X-ray Microscopy. Technical Note

MEDICAL PHYSICS (MED PHYS)

SI8000 Live Cell Imaging System

Applicability of Hyperspectral Fluorescence Imaging to Mineral Sorting

High Power Operation of Cryogenic Yb:YAG. K. F. Wall, B. Pati, and P. F. Moulton Photonics West 2007 San Jose, CA January 23, 2007

FOBA Y-Series. High potential fiber marking lasers: More clarity, less complexity. Your product benefits

Resolution of Microscopes Visible light is nm Dry lens(0.5na), green(530nm light)=0.65µm=650nm for oil lens (1.4NA) UV light (300nm) = 0.13µm f

Next Level of Super Resolution Fluorescence Microscopy

Zeaxanthin-dependent non-photochemical quenching does not occur in Photosystem I in the higher plant Arabidopsis thaliana

Welcome! openmicberkeley.wordpress.com. Open Berkeley

Lasers service a diverse range of biomedical

Confocal bioluminescence imaging for living tissues with a caged. substrate of luciferin

Characterization of NADH lifetime at different cell densities in a culture

>10 11 ohm-cm. ε T 11/ε0=6.7, ε T 33/ε0=8.1; Tan δ<0.001

Multiphoton lithography based 3D micro/nano printing Dr Qin Hu

Light dosimetry for Low-Level Laser therapy: Accounting for differences in tissue and depth

LUPAS Luminescent Polymers for in vivo Imaging of Amyloid Signatures

An automated image processing routine for segmentation of cell cytoplasms in high-resolution autofluorescence images

Lab-on-a Chip Systems. with Optical Detection of Toxicological Effects. in Medicine

Lighting research Toulouse team (France) Ludovic VANQUIN Ikbal MARGHAD Lydie AREXIS BOISSON

Multiexcitation Fluorescence and Reflectance Spectroscopy as a Real Time Guide to Biopsy in Vivo

Molecular Imaging: Definition, Overview and Goals

Multimodal microscopy with sub-30 fs Yb fiber laser oscillator

AURORA AIRY BEAM LIGHT SHEET IMAGING SYSTEM THE CUSTOM DEVELOPMENT PROGRAMME

Delivering top performance. Outstanding value. Diagnostic scalability. ACUSON X150 Ultrasound System.

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

Fpollutant-free zero air for analytical

Corning Microplates for Microscopy and High Content Imaging. Improve results with microplates for high resolution cell imaging

Multiphoton Microscopy: Seeing deeper and clearer

Exam MOL3007 Functional Genomics

Editor s Introduction: Optical Methods for Biomedical Diagnosis

Image Capture, Processing and Analysis of Solar Cells for Engineering Education

NovoCyte Flow Cytometer

Fluorescent Sensor Detects Microbes in Real Time

Advantages of Photodiode Array

Chemiluminescence Detection. Using UVP s ChemiDoc-It System

ProFoss for in-line process analysis of dairy powder

Mid-IR Laser oscillation via energy transfer in the Co:Fe:ZnS/Se codoped

CBI Toolbox Tour 2015

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Ultrashort Pulsed Laser Light A Cool Tool for Ultraprecise Cutting of Tissue and Cells

Challenges to measuring intracellular Ca 2+ Calmodulin: nature s Ca 2+ sensor

Optimization of Biophotonics and Optomechanics for Frequency Domain Tissue Fluorescence Measurements. by Luwei Zou

Modification of Glass by FS Laser for Optical/Memory Applications

Agricultural production environmental stress herbicides

Innovations To Meet Your Needs

The analysis of fluorescence microscopy images for FRET detection

Thermo Scientific ArrayScan XTI High Content Analysis Reader. revolutionizing cell biology with the power of high content

Laser Produced Plasma for Production EUV Lithography

Going deeper than microscopy: the optical imaging frontier in biology

SIL-based confocal fluorescence microscope for investigating individual nanostructures

DEPArray Technology. Sorting and Recovery of Rare Cells

Double-pulse fluorescence lifetime measurements

Radiography Curriculum Analysis

XDS TM Multipurpose NIR-analyser for Laboratories

Transcription:

Experts in Femtosecond Laser Technology DermaInspect Non-invasive multiphoton tomography of human skin In vivo optical biopsies with subcellular spatial resolution based on near infrared femtosecond laser technology for: Diagnostics of dermatological disorders Melanoma detection Tissue engineering Cosmetic research In situ drug monitoring Intratissue imaging of pharmaceutical components DermaInspect

DermaInspect A -marked system for in vivo multiphoton tomography of skin with submicron spatial resolution Product description DermaInspect is a novel imaging device which provides non-invasive in vivo optical biopsies of skin with ultrahigh subcellular resolution. The 1M class system uses a femtosecond laser beam for multiphoton excitation of biomolecules like NAD(P)H, flavins, porphyrins, elastin, and melanin. The extracellular matrix element collagen is imaged by its second harmonic generation (SHG). Autofluorescence and SHG signals are recorded by fast PMT detectors. The system consists of a compact, turn-key tunable femtosecond near infrared (NIR) laser, a beam scanning module with galvoscanners and piezo driven optics, a PMT detector module as well as a control unit including JenLab Image software for 3D, 4D and 5D image processing. In vivo adaptor

FLIM Technology In addition to 3D fluorescence imaging by optical sectioning and monitoring of the fluorescence intensity, DermaInspect system can be upgraded with a FLIM module of an external manufacturer for fluorescence lifetime imaging. DermaInspect combined with the time correlated single photon counting (TCSPC) module can perform fluorescence lifetime imaging (FLIM) at different tissue depths with a temporal resolution of 250 ps. The fluorescence lifetime τ adds a 4 th dimension to the high resolution images and provides information on the type of the fluorescent biomolecule as well as molecular interactions within the microenvironment. For example, typical fluorescence lifetimes of free NADH, NADH-protein complexes and porphyrin monomers are 200 ps, 2 ns, and 10 ns, respectively. Spectral Imaging The multiphoton tomograph DermaInspect can be further upgraded to a 5D system in order to obtain information on the emission spectrum (spectral imaging with submicron spatial resolution). Fluorescence intensity image, false-color coded FLIM image, fluorescence lifetime histogram and fluorescence decay kinetics at a particular position

References Applications The major aim for the development of the Derma- Inspect was skin cancer diagnosis. Using innovative non-invasive multiphoton technology the physician obtains detailed information on the living intratissue cells and the tissue architecture within their natural environment. Dermatological disorders and melanoma can now be detected with submicron spatial resolution. Having a short acquisition time of seconds, DermaInspect revolutionizes conventional invasive and highly time consuming diagnostic procedures. The system is used in tissue engineering for the detection of cells and extracellular matrix components, in the research of wound healing and skin aging, in monitoring of therapeutical effects as well as in cosmetic and pharmaceutical research. FLIM and spectral imaging provide further contrast mechanisms for in situ drug monitoring. Researchers using this combination will have an exclusive fourdimensional view on biological processes within living tissue. DermaInspect is routinely used in various research institutes and hospitals in Europe, Asia and Australia. K. König, I. Riemann: High-resolution multiphoton tomography of human skin with sub cellular spatial resolution and picosecond time resolution. Journal of Biomedical Optics 8, 432-439 (2003) K. König, A. Ehlers, F. Stracke, I. Riemann: In vivo Drug Screening in Human Skin Using Femtosecond Laser Multiphoton Tomography. Skin Pharmacology and Physiology 19, 78-88 (2006) K. König, I. Riemann, A. Ehlers, R. Bückle, E. Dimitrow, M. Kaatz, J. Fluhr, P. Elsner: In vivo multiphoton tomography of skin cancer. Proc. of SPIE Vol. 6089, pp 118-124 (2006) M.J. Koehler, K. König, P. Elsner, R. Bückle, M. Kaatz: In vivo assessment of human skin aging by multiphoton laser scanning thomography. Optics Letters 31, 2879-2881 (2006) z y x 3D reconstruction of elastin and collagen structures in tissue

Single fluorescent intratissue mitochondria can be imaged within the epidermis Multiphoton tomography provides a detailed look into the skin z: tissue depth in μm

Technical data compact turn-key tunable Ti:sapphire femtosecond laser laser pulse width: < 100 fs repetition frequency: 80 / 90 MHz mean laser output: 0... 1.5 W (typical) wavelength range: 720... 920 nm (typical) full-frame scanning, region-of-interest (ROI) scanning, line scanning, single-point illumination (spot scan) typical scan range: 350 350 μm (horizontal) 200 μm (vertical) spatial resolution: < 1 μm (horizontal) < 2 μm (vertical) focusing optics: magnification 40 numerical aperture (NA) 1.3 video adapter for visualization with CCD-camera control and image processing software (JenLab scan, JenLab Image) operating temperature: 15... 35 C (59... 95 F) relative humidity: 5... 65 % power requirements: 230 VAC (50 Hz) or 115 VAC (60 Hz) certified class 1M medical product System dimensions (typical) workstation: 1200 780 1100 mm 3 180 kg scan module: 615 255 210 mm 3 16 kg control unit: 450 460 190 mm 3 12 kg Ti:sapph laser: 600 370 180 mm 3 42 kg (laser head) 41 kg (power supply) chiller: 270 200 380 mm 20 kg The complete system needs a minimum space of 8 m 2. Air-conditioning is recommended. System operation requires reduction of ambient light. Notes: These specifications are subject to change without notice. DermaInspect is not intended as a primary diagnostic means. Experts in Femtosecond Laser Technology JenLab GmbH Schillerstrasse 1 D-07745 Jena Germany Tel.: +49 (0) 3641 470 501 Fax: +49 (0) 3641 470 543 e-mail: info@jenlab.de URL: www.jenlab.de