OREGON ROOF CONSULTING - ROOF INSPECTION FORM

Similar documents
ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

ALLMET CONTINENTAL INSTALLATION GUIDE

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

1 Exam Prep Roofing Practice Exam 12

Weatherproofing & Sealing Systems

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

TECHNICAL INFORMATION

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

METAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

the HOME REFERENCE BOOK the encyclopedia of homes

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

TEXAS DEPARTMENT OF HOUSING AND COMMUNITY AFFAIRS OFFICE OF COLONIA INITIATIVES TEXAS BOOTSTRAP LOAN PROGRAM. Form 15 Work Write-Up

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

11 FLAT ROOF CONSTRUCTION

Roofing Policy for Commercial Buildings

Sonoma County Reroofing Guidelines. Revised July 2008

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ROOFING APPLICATION STANDARD (RAS) No. 120 MORTAR AND ADHESIVE SET TILE APPLICATION

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

Lithia Dodge East 5500 L St. Omaha, NE

1 Exam Prep. Roofing Practice Exam 9

Water Intrusion Into Buildings Forensic Investigations

FIRESTONE ULTRAPLY TPO SA APPLICATION GUIDE

HIDDEN HOLES IN WOOD FRAMED BALCONY WATERPROOFING

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

GenFlex EZ TPO Peel & Stick SA (HW) APPLICATION GUIDE

Tile Roofing Inspection

INSTALLATION INSTRUCTIONS KÖSTER TPO

1.1 SECTION INCLUDES Verify Scope, including identification of plies and type of coating.

Radon Vent Pipe System. Labeling Performance Indicators

ROOF SUBSTRATE PREP MANUAL

1 Firestone EPDM Roofing Systems

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION

Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

Fast Track Re-Roof Permit Checklist

Exterior Stucco and Siding Installation

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

MAKE ROOFS LAST LONGER

The HardieZone System: HZ5 Care and Maintenance Guide

My Home Was Built In What Can I Expect To See On My Report?

Building Envelope Systems Exam Learning Objectives

Scope. Definitions. For definitions of terms used in this application standard, refer to ASTM 1079 and the Florida Building Code, Building.

Precision 20/20 Full Reserve Study for. Sevanna Park Condominium Association Ithaca, New York March 27, 2013

Margaret Batts Tobin Laboratory

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Roofing Underlayment Systems

Custom 24 x 26 Garage Plan Roy Hartmann Plan #g218 By SDS-CAD Specialized Design Systems CLIENT

Product Technical Bulletin APS-5T

Recommended installation procedures for Harvest and Beaumont Shake Note: Harvest Shake is 7 5/8 exposure and Beaumont Shake is 9 exposure

APPLICATION SAFETY TOOLS REQUIRED

UFGS (June 2005) UNIFIED FACILITIES GUIDE SPECIFICATIONS

DURO-SHIELD ROOF COATING CARE GUIDE TABLE OF CONTENTS

GAF Scheduled Maintenance Checklist

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER:

DUKE UNIVERSITY CONSTRUCTION STANDARDS

RoofKit Roofing Membrane Products:

ROOF REPORT 3130 TCHULAHOMA

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

ISO Types 1-6: Construction Code Descriptions

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Chapter 2 Understanding The Problem

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

Grace Ice & Water Shield

Western States 7/8 Corrugated

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

SAM HOUSTON STATE UNIVERSITY DIVISION 07 THERMAL & MOISTURE PROTECTION SECTION ROOFING SYSTEMS DESIGN AND CONSTRUCTION STANDARDS February 2016

Rubber Roofing Pocket Application Guide

FLUID APPLIED WATERPROOFING

HOME DEVELOPMENT GUIDE

DuPont RainVent Batten Installation Guidelines

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

Industry Standard Terms & Definitions Of The Steel Deck Institute

SECTION ALPHAGUARD RESTORATION 20 YEAR WARRANTY SYSTEM. f. Conditions and Division 01 Specification Sections, apply to this Section.

ITEM 458 WATERPROOFING FOR STRUCTURES

GRP Flat Roofing Edge Trims

4 EXTREME FOUNDATION PANELS

Agenda. Safety Decking Basics Decking Issues Felt Kick Out Flashing Fascia

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

Building Enclosure Detailing for Balconies

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Product Technical Bulletin SPM-4H-250

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

Structural Inspection

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

LP SmartSide Perfection Shingle

SECTION CO-POLYMER ELASTOMERIC COOL-ROOF COATING

ARCHITECTURAL SPECIFICATIONS LOOSE LAID & BALLAST SYSTEM

SECTION COMPOSITE ROOF TILE SYSTEMS

SUBFLOOR AND INSTALLATION PREPARATION INSTRUCTIONS

Roof Replacement Specifications Section METHOD SPECIFICATONS, ROOF REPLACEMENT AT THE LOG COLLEGE MIDDLE SCHOOL. CENTENNIAL SCHOOL DISTRICT:

SPECIFICATION SUBMITTAL

Jackson Plant: 308 Alabama Blvd. Jackson, GA (800) /Fax: (800)

TPO and PVC Roof Flashings and Accessories

Carpenter Level 2 Rev. September 2017

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

Transcription:

Oregon CCB: 199121 PO Box 220190, Milwaukie, OR 97222 Washington License: OREGORC871MR OREGON ROOF CONSULTING - ROOF INSPECTION FORM General Roof Conditions: NA = Not Applicable Debris on Roof Physical Damage Structural Deformation Drainage Gutters and Downspouts Overall Access Sloped Roof: Roof Material / # of layers Condition of Surface Deformed Edges Shingles Buckled; Curled; Missing Granule Loss Page 1 Roof Inspection Form Rev: 7/22/2013

Signs of Previous Repairs Ventilation Flashing Chimneys Skylights Solar Panels Fasteners Soffit / Fascia Fall Arrest Anchors TV or Radio Antenna Final Exterior Wall Surfaces: Deformed Finish Surface deterioration Staining Damaged / Missing Siding Final Page 2 Roof Inspection Form Rev: 7/22/2013

Flat / Membrane Roof: Condition of Coating Granular Loss Punctures Cracks / Alligatoring Blisters / Fishmouths Ponding Protrusions Drains / Scuppers Final Interior Ceiling Conditions: Cracks Water Staining Water Leaks Seasonal Change Page 3 Roof Inspection Form Rev: 7/22/2013

Signs of Previous Ceiling Repairs Final Interior Wall Surfaces: Cracks Water Staining Water Leaks Deformed Finish Seasonal Change Window Leaks Door / Window Alignment Signs of Previous Repairs Final OCCUPANT / OWNER RESPONSIBILITIES Immediately note any signs of damage, staining, leaking, degradation, structural anomalies, or envelope movement, especially after extreme weather conditions. Page 4 Roof Inspection Form Rev: 7/22/2013

GLOSSARY OF ROOFING TERMS USED IN THIS CHECKLIST 1. Alligatoring: Shrinkage cracking on flat roof resembling alligator hide. 2. Asphalt: A highly viscous hydrocarbon produced from the residuum left after the distillation of petroleum; used as a waterproofing agent of a built up roof. Also the primary component of most composition shingles. 3. Ballast: An anchoring material (such as rock, gravel, pavers) used to resist wind uplift forces of roof membrane. 4. Bitumen: A generic term for asphalt or coal tar pitch roofing. 5. Bird Block: The vents between rafters at overhangs. 6. Blister: A spongy raised portion of roofing membrane as a result of pressure of entrapped air or water vapor. 7. Built-up Roofing (BUR): A continuous, semi-flexible roof covering consisting of laminations or plies of saturated or coated felts alternated with layers of bitumen. 8. Cant Strip: A continuous strip of triangular cross section, fitted into the angle formed by the structural deck and a wall or other vertical surface, and used as a gradual transition for base flashing and horizontal roof membrane. 9. CDX: 8'X4' plywood sheets typically 4-ply, sometimes 5-ply. 10. Coil Nails: Cartridges for air or electrical powered nail guns. 11. Counter Flashing: Metal pieces between bricks that come down and overlap roof deck flashing that are sandwiched within the roofing. 12. Cowboy: Marginally skilled poorly trained roofer. 13. Crack: A break in a roofing membrane as a result of flexing, often occuring at a ridge or a seam. 14. Cupping: Curling / raising of composition shingles. 15. Curb: A wood frame around a skylight opening that the skylight unit is fitted upon. Metal flashing is then wrapped around the curb or 'frame'. 16. Dead Valley: A flat section on a pitched roof where multiple sections meet. These are infrequent but when encountered require special attention. These should be covered with sheet metal and not membrane. 17. Drip Edge: Bottom edge of roof leading into gutter. 18. Eaves: The protective overhang at the lower edge of a sloped roof. 19. Expansion Joints: A deliberate separation of two roof areas to allow expansion and contraction movements of the parts. 20. Fascia: The finish member covering the edges or eaves of a flat or sloping roof or roof overhang. 21. Fishmouths: An opening of the lapped edge of applied felt in built up roofing due to adhesion failure. Page 5 Roof Inspection Form Rev: 7/22/2013

22. Flashing: Connecting devices that seal membrane joints, drains, gravel stops and other places where membrane is interrupted. Base flashing forms the upturned edges of the watertight membrane. Cap or counter-flashing shields the exposed edges and joints of the base flashing. Perimeter and valley metal components of a sloped roof also are called flashing as are individual pieces that are placed at a sidewall, skylight, or chimney. Pipe jacks are also called pipe flashings. 23. Gravel Stop: Flanged device, normally metallic, designed to prevent loose aggregate from washing off the roof. It also provides a finished edge detail for built-up roof assembly. 24. High Risk Roof: A roof that is high, steep, or has difficult access. 25. Hip: Point / apex where two sections / faces meet. 26. No-Caulk Flange: Cheap neoprene/rubber pipe jacks that don't last. 27. OSB (Oriented Strand Board): Inferior plywood substitute. 28. Overlay: Installing roofing over existing roof. BAD idea. 29. Parapet: The part of the wall entirely above the roof. 30. Ponding: The collection of water at in shallow points on the roof. 31. Power Mast: Post that penetrates roof holding electricity wires. 32. PVC: A generic term for single-ply plastic sheet membrane (poly vinyl chloride), seams are fused by solvent or hot air welding techniques. 33. Rake Edge: The side edges of a right angle roof. Also called 'Gables.' 34. Ridge: Top of roof or 'peak.' Term also describes hips. 35. Slope: The ratio between the rise and the horizontal span. 36. Soffit: The finish on the underside of a roof overhang. 37. Starter Course: Strip of material used prior to the installation of the first course of exposed roofing material. 38. Step Flashing: Pieces of metal used at sidewalls and sides of chimneys or skylights. Usually bent at a 90 degree angle. 39. Torchdown: Method of applying flat roof membranes using a propane torch. 40. Valley: Joint or 'trough' where two roof sections meet. Page 6 Roof Inspection Form Rev: 7/22/2013