Index terms Diagrid, Nonlinear Static Analysis, SAP 2000.

Similar documents
NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Performance Based Seismic Design of Reinforced Concrete Building

Pushover analysis of RC frame structure using ETABS 9.7.1

PERFORMANCE BASED SEISMIC EVALUATION OF MULTI-STOREYED REINFORCED CONCRETE BUILDINGS USING PUSHOVER ANALYSIS

OPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS (PUSH OVER ANALYSIS)

DIAGRID STRUCTURAL SYSTEM: STRATEGIES TO REDUCE LATERAL FORCES ON HIGH-RISE BUILDINGS

Application of Pushover Analysis for Evaluating Seismic Performance of RC Building

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

DYNAMIC ANALYSIS OF STEEL TUBE STRUCTURE WITH BRACING SYSTEMS

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Seismic Assessment of an RC Building Using Pushover Analysis

Seismic performance assessment of reinforced concrete buildings using pushover analysis

NONLINEAR STATIC ANALYSIS OF R.C.C. FRAMES (Software Implementation ETABS 9.7)

Nonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale

3.5 Tier 1 Analysis Overview Seismic Shear Forces

ctbuh.org/papers CTBUH Recommendations for the Seismic Design of High-Rise Buildings

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Assessment of P-Delta Effect on High Rise Buildings

Seismic Base Isolation of RC Frame Structures With and Without Infill

NONLINEAR PERFORMANCE OF A TEN-STORY REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME (SMRF)

Seismic Performance Evaluation of Torsionally Asymmetric Buildings

PUSHOVER ANALYSIS FOR THE RC STRUCTURES WITH DIFFERENT ECCENTRICITY

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Council on Tall Buildings. and Urban Habitat

Available at ISSN

Design check of BRBF system according to Eurocode 8 Use of pushover analysis

Concept of Earthquake Resistant Design

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

4.2 Tier 2 Analysis General Analysis Procedures for LSP & LDP

Seismic Analysis of Truss Bridges with Tall Piers

SEISMIC CAPACITY EVALUATION OF POST-TENSIONED CONCRETE SLAB-COLUMN FRAME BUILDINGS BY PUSHOVER ANALYSIS

Seismic Performance and Design of Linked Column Frame System (LCF)

STUDY ON STRUCTURAL BEHAVIOUR OF HEXAGRID STRUCTURAL SYSTEMS IN MULTI STOREY BUILDINGS

ON DRIFT LIMITS ASSOCIATED WITH DIFFERENT DAMAGE LEVELS. Ahmed GHOBARAH 1 ABSTRACT

Seismic Analysis and Design of Vertically Irregular RC Building Frames

CAPACITY BASED DESIGN OF COLD FORMED STORAGE RACK STRUCTURES UNDER SEISMIC LOAD FOR RIGID AND SEMI RIGID CONNECTIONS

Determine Seismic Coefficients of Structural Using Pushover Nonlinear Analysis

DESIGN OF HIGH-RISE CORE-WALL BUILDINGS: A CANADIAN PERSPECTIVE

Inelastic Versus Elastic Displacement-Based Intensity Measures for Seismic Analysis

Evaluation of Seismic Behavior for Low-Rise RC Moment Resisting Frame with Masonry Infill Walls

Study of P-Delta Effect on Tall Steel Structure

Seismic Evaluation of Steel Moment Resisting Frame Buildings with Different Hysteresis and Stiffness Models

Analytical Study on Seismic Performance of Hybrid (DUAL) Structural System Subjected To Earthquake

Descriptive Study of Pushover Analysis in RCC Structures of Rigid Joint

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

PERFORMANCE OF LATERAL SYSTEMS ON TALL BUILDINGS

Seismic Analysis of Steel Frames with Different Bracings using ETSBS Software.

EFFECT OF PLACEMENT AND OPENINGS IN SHEAR WALL ON THE DISPLACEMENT AT VARIOUS LEVELS IN A BUILDING SUBJECTED TO EARTHQUAKE LOADS

PERFORMANCE- BASED SEISMIC DESIGN OF A BUILDING

[Mohammed* et al., 5(8): August, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Lecture 5 Building Irregularities

EVALUATION OF MODAL PUSHOVER ANALYSIS USING VERTICALLY IRREGULAR FRAMES

HYBRID MOMENT RESISTING STEEL FRAMES

THE DEGREE OF ACCURACY OF MODAL PUSHOVER ANALYSIS ON DUAL SYSTEM STRUCTURE INCORPORATING SHEAR WALL INELASTICITY

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

Pushover Analysis of Steel Frame Structures with Different Types of Bracing System

Damage-control Seismic Design of Moment-resisting RC Frame Buildings

Evaluation of Earthquake Risk Buildings with Masonry Infill Panels

NON-LINEAR STRUCTURAL INTEGRITY ANALYSIS

Seismic Behavior of High Rise Building for Soft Soil in All Seismic Zones Shaik Fayaz 1 Mrs. B.Ajitha 2

Study of Inelastic Behavior of Eccentrically Braced Frames under Non Linear Range

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

PEER Tall Building Seismic Design Guidelines

Simi Aboobacker 1 and Nisha Varghese 2

SEISMIC ANALYSIS OF BRACED STEEL FRAMES

SEISMIC EVALUATION OF HIGH RISE STEEL STRUCTURES WITH AND WITHOUT BRACING

Earthquakes Analysis of High Rise Buildings with Shear Walls at the Center Core and Center of Each Side of the External Perimeter with Opening

Effect of Concentric Braces on the Behaviour of Steel Structure by Pushover Analysis

Title. Author(s)ARDESHIR DEYLAMI; MOSTAFA FEGHHI. Issue Date Doc URL. Type. Note. File Information IRREGULARITY IN HEIGHT

Nonlinear Static Pushover Analysis of a Shear Wall Building in Madinah

Seismic Safety Evaluation of Bridge Structures Based on Inelastic Spectrum Method

THE EXTENDED N2 METHOD IN SEISMIC DESIGN OF STEEL FRAMES CONSIDERING SEMI-RIGID JOINTS

Stability Analysis of Rigid Steel Frames With and Without Bracing Systems under the Effect of Seismic and Wind Loads

Comparative study of Performance of RCC Multi-Storey Building for Koyna and Bhuj Earthquakes

MULTI-LEVEL FORTIFICATION INTENSITIES SEISMIC PERFORMANCE ASSESSMENT FOR REINFORCED CONCRETE FRAME- SHEAR WALL STRUCTURE WITH VISCOUS DAMPERS

ECCENTRICALLY BRACED FRAME DESIGN FOR MODERATE SEISMIC REGIONS

[Jagadeesh B N* et al., 5(9): September, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

EVALUATION OF THE NEED FOR WEAK BEAM-STRONG COLUMN DESIGN IN DUAL FRAME-WALL STRUCTURES

Parametric Study of Dual Structural System using NLTH Analysis Ismaeel Mohammed 1 S. M. Hashmi 2

Performance Based Inelastic Seismic Analysis of Buildings

Bahram Marabi* & Abdul Kadir Marsono

Seismic Performance Evaluation of Eccentrically Braced Frame Using PBPD Method

P-DELTA EFFECTS ON TALL RC FRAME-WALL BUILDINGS

INTERACTION OF TORSION AND P-DELTA EFFECTS IN TALL BUILDINGS

PUSHOVER ANALYSIS OF BUILDING WITH INFILL WALL

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

Modelling of RC moment resisting frames with precast-prestressed flooring system

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online):

Application of Buckling Restrained Braces in a 50-Storey Building

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 11, 2016 ISSN (online):

COST C26. Urban Habitat Constructions under Catastrophic Events EARTHQUAKE RESISTANCE WG 2 Session, March 30th

Behaviour and design of innovative hybrid coupled shear walls for steel buildings in seismic areas

Design Provisions for Earthquake Resistance of Structures. The Standards Institution of Israel

Seismic design of braced frame gusset plate connections

A COMPARISON BETWEEN THE REQUIREMENTS OF PRESENT AND FORMER ROMANIAN SEISMIC DESIGN CODES, BASED ON THE REQUIRED STRUCTURAL OVERSTRENGTH

CHAPTER 8 THE DESIGN AND ANALYSIS OF MULTI-STORY BUILDINGS WITH LARGE MOMENT END-PLATE CONNECTIONS 8.1 INTRODUCTION

Transcription:

Pushover Analysis of Diagrid Structure Ravi K Revankar, R.G.Talasadar P.G student, Dept of Civil Engineering, BLDEA S V.P Dr P.G Halakatti College of Engineering & Technology Bijapur-586101 Associate Professor, Dept of Civil Engineering, BLDEA S V. P Dr P.G Halakatti college of Engineering & Technology, Bijapur-586101 Abstract Diagrid is a particular form of space truss. It consists of perimeter grid made up of a series of triangulated truss system. Diagrid is formed by intersecting the diagonal and horizontal components. The diagonal members in diagrid structural systems can carry gravity loads as well as lateral forces due to their triangulated configuration. Diagrid structures are more effective in minimizing shear deformation because they carry lateral shear by axial action of diagonal members. Diagrid structures generally do not need high shear rigidity cores because lateral shear can be carried by the diagonal members located on periphery. In this paper study of diagrid system which is modeled with 12 storey diagrid building is analyzed using SAP 2000 by considering Dead, Live and Seismic Loads (IS 1893-Part-1, 2002) and designed using IS-800. Afterwards the FEMA 356 hinges are assigned to the same building and conducted Nonlinear Static (Pushover) to find out the performance points that is Immediate Occupancy, Life Safety, and Collapse Prevention of diagrid elements. At the same time Base Shear and Displacements are studied and Spectral Displacement Demand & Spectral Displacement Capacity is compared to know the adequacy of design. And it is evident that the designed 12 storey diagrid building doesn t require redesign. Index terms Diagrid, Nonlinear Static Analysis, SAP 2000. I. INTRODUCTION The rapid growths of urban population and consequent pressure on limited space have considerably influenced the residential development of city. The high cost of land, the desire to avoid a continuous urban sprawl, and the need to preserve important agricultural production have all contributed to drive residential buildings upward. As the height of building increase, the lateral load resisting system becomes more important than the structural system that resists the gravitational loads. The lateral load resisting systems that are widely used are: rigid frame, shear wall, wall-frame, braced tube system, outrigger system and tubular system. Recently, the Diagrid Diagonal Grid structural system is widely used for tall steel buildings due to its structural efficiency and aesthetic potential provided by the unique geometric configuration of the system. Diagrid is a particular form of space truss. It consists of perimeter grid made up of a series of triangulated truss system. Diagrid is formed by intersecting the diagonal and horizontal components. 168 The diagonal members in Diagrid structural systems can carry gravity loads as well as lateral forces due to their triangulated configuration. Diagrid structures are more effective in minimizing shear deformation because they carry lateral shear by axial action of diagonal members. Compared with conventional framed tubular structures without diagonals, Diagrid structures are more effective in minimizing shear deformation because they carry shear by axial action of the diagonal members, while conventional framed tubular structures carry shear by the bending of the vertical columns (Moon, 2007). Diagrid structures generally do not need high shear rigidity cores because shear can be carried by the Diagrid located on the perimeter. In this study the seismic performance of Diagrid structural system was investigated using nonlinear static analysis. II. LOADS ON STRUCTURE A. Dead Load It is a gravity loading due to the structure simply calculated as the product of volume and material density of the structure. B. Imposed Load [5] The imposed loads to be assumed in the design of buildings shall be the greatest loads that probably will be produced by the intended use or occupancy, but shall not be less than the equivalent minimum loads specified in Table. In our analysis only Commercial building loads are considered. C. Seismic Load [6] If a structure is situated in an earthquake prone region, the earthquake or seismic forces are given due consideration in the analysis. An earthquake causes vertical and horizontal forces in the structure that will be proportional to the weight of the structure. IS: 1893 Part-1 is referred for the actual design loads. III. NONLINEAR STATIC (PUSHOVER) ANALYSIS The use of the nonlinear static analysis came in to practice in 1970 s but the potential of the pushover analysis has been recognized for last 10-15 years. This procedure is mainly used to estimate the strength and drift capacity of existing structure and the seismic demand for this structure subjected to selected earthquake. This procedure can be used for checking the adequacy of new structural design as well.

Pushover analysis is defined as an analysis wherein a mathematical model directly incorporating the nonlinear load-deformation characteristics of individual components and elements of the structure shall be subjected to monotonically increasing lateral loads representing inertia forces in an earthquake until a target displacement is exceeded. Target displacement is the maximum displacement (elastic plus inelastic) of the structure at top expected under selected earthquake ground motion. Pushover analysis assesses the structural performance by estimating the force and deformation capacity and seismic demand using a nonlinear static analysis algorithm. The seismic demand parameters are global displacements (at roof or any other reference point), storey drifts, storey forces, and component deformation and component forces. The analysis accounts for geometrical nonlinearity, material inelasticity and the redistribution of internal forces. Response characteristics that can be obtained from the pushover analysis are summarised as follows: a) Estimates force and displacement capacities of the structure. Sequence of the member yielding and the progress of the overall capacity curve. b) Estimates force (axial, shear and moment) demands on potentially brittle elements and deformation demands on ductile elements. c) Estimates global displacement demand, corresponding inter-storey drifts and damages on structural and nonstructural elements expected under the earthquake ground motion considered. d) Sequences of the failure of elements and the consequent effect on the overall structural stability. e) Identification of the critical regions, where the inelastic deformations are expected to be high and identification of strength irregularities (in plan or in elevation) of the building. IV. PUSHOVER ANALYSIS PROCEDURE Pushover analysis is a static nonlinear procedure in which the magnitude of the lateral load is increased monotonically maintaining a predefined distribution pattern along the height of the Structure. Structure is displaced till the control node reaches target displacement or structure collapses. The sequence of cracking, plastic hinging and failure of the structural components throughout the procedure is observed. The relation between base shear and control node displacement is plotted for all the pushover analysis. Generation of base shear control node displacement curve is single most important part of pushover analysis. This curve is conventionally called as pushover curve or capacity curve. The capacity curve is the basis of target displacement estimation. The seismic demands for the selected earthquake are calculated at the target displacement level. The seismic demand is then compared with the 169 corresponding structural capacity or predefined performance limit state to know what performance the structure will exhibit. V. NEED FOR NON-LINEAR STATIC (PUSHOVER) ANALYSIS Conventionally, seismic assessment and design has relied on linear or equivalent linear (with reduced stiffness) analysis of structural systems. In this approach, simple models are used for various elements of the structure, which are subjected to seismic forces evaluated from elastic or design spectra, and reduced by force reduction (or behavior) factors. This ensures displacements are amplified to account for the reduction of applied forces. The reduced force-amplified deformation linear elastic approach fails to fit within the principle of failure mode control, which is part of performance based assessment and design. This in turn has led to an increase in the use of inelastic analysis as a more realistic means of assessing deformational state in structures subjected to strong ground motions. The pushover analysis is a significant step forward by giving consideration to those inelastic response characteristics that will distinguish between good and bad performance in severe earthquakes. The non linear static pushover analysis is a partial and relatively simple immediate solution to the complex problem for predicting forces and deformation demands imposed on the structure and its elements due to ground motions. The pushover is part of an evaluation process and provides estimates of demands imposed on structures and elements. Hence, there is always a need of a method which is rational and accurate and at the same time able to identify seismic deficiencies correctly and that too in a correct order of vulnerability. Pushover analysis is able to satisfy these criteria satisfactorily and in a convenient way. VI. CAPACITY SPECTRUM METHOD (ATC 40) In this method the maximum inelastic deformation of a nonlinear SDOF system can be approximated from the maximum deformation of a linear elastic SDOF system with an equivalent period and damping. This procedure uses the estimates of ductility to calculate effective period and damping. This procedure uses the pushover curve in an acceleration-displacement response spectrum (ADRS) format. This can be obtained through simple conversion using the dynamic properties of the system. The pushover curve in an ADRS format is termed a capacity spectrum for the structure. The seismic ground motion is represented by a response spectrum in the same ADRS format and it is termed as demand spectrum (Fig. 1). The equivalent period (Teq) is computed from the initial period of vibration (Ti) of the nonlinear system and displacement ductility ratio (μ). Similarly, the equivalent damping ratio (βeq) is computed from initial damping ratio and the displacement ductility ratio (μ). ATC 40 provides the following equations to

calculate equivalent time period (Teq) and equivalent damping (βeq). Fig 1. Schematic representation of Capacity Spectrum Method (ATC 40) VII. PROBLEM DEFINITION This paper presents about details of the building (Table 1) used for analysis such as dimensions of building, type of analysis and material used. A 12 Storey Steel Diagrid Structure having height of 48 m and lateral dimensions of 27m X 27m. The loads and load combinations on the structure are studied and the same building is modeled in SAP 2000 and conducted Linear Analysis to get the maximum bending moments and the structure is designed as per IS 800. Afterwards the FEMA 356 Hinges are defined in the model and conducted Nonlinear Static (Pushover) Analysis using ATC-40 to calculate Base Shear vs. Displacements, Effective time, Spectral Displacement Capacity & Spectral Displacement Demand and to find out Performance points of Diagrid Structure. Fig 2. Plan of Diagrid Structure Sl. No 1 2 Dimensions of Building Height of Building Building Details Description 27m X 27m 48 m 3 No. of Stories 12 No s 4 Storey Height 4 m 5 Type of Diagrid Steel Structure Structure 6 Degree of Diagrid Element 53 8 7 Type of Analysis Nonlinear Analysis Table 1. Building Details Fig 3. Diagrid Structure Model in SAP 2000 170

A) Modeling of Flexural hinges In the implementation of pushover analysis, the model must account for the nonlinear behavior of the structural elements. In the present study the plastic hinge is assumed to be concentrated at a specific point in the frame member under consideration. In this study flexure (M3) hinges (FEMA 356 - Auto hinges) modeled at possible plastic regions under lateral load. Properties of flexure hinges must simulate the actual response of structural steel components subjected to lateral load. Fig 5. Idealized moment-rotation curve VIII. RESULTS The modeled building is analysed using Nonlinear Static (Pushover) analysis. This chapter presents Nonlinear Static (Pushover) analysis results and its discussions. Pushover analysis was performed first in a load control manner to apply all gravity loads on to the structure (gravity push). Then a lateral pushover analysis in transverse direction was performed in a displacement control manner starting at the end of gravity push. The results obtained from these analyses are checked by comparing spectral displacement demand and spectral displacement capacity from the pushover curve. Fig 4. Coordinate system used to define the flexural hinges Flexural hinges in this study are defined by momentrotation curves calculated based on the cross-section and member details at the possible hinge locations. For calculating hinge properties it is required to carry out moment curvature analysis of each element. Constitutive relations for structural steel, plastic hinge length in structural element are required for this purpose. B) Moment-rotation parameters Moment-rotation parameters are the actual input for modeling the hinge properties and this can be calculated from the moment-curvature relation. The moment-rotation curve can be idealized as shown in Fig. 5, and can be derived from the moment-curvature relation. The main points in the moment-rotation curve shown in the figure can be defined as follows: 1) The point A corresponds to the unloaded condition. 2) The point B corresponds to the nominal yield strength and yield rotation θ y 3) The point C corresponds to the ultimate strength and ultimate rotation θ u, following which failure takes place. 4) The point D corresponds to the residual strength, if any, in the member. It is usually limited to 20% of the yield strength, and ultimate rotation, θ u can be taken with that. 5) The point E defines the maximum deformation capacity and is taken as 15θ y or θ u, whichever is greater. A) Nonlinear static (pushover) analysis Nonlinear Static (Pushover) Analysis permits to identify critical members likely to reach limit states during the earthquake. Nonlinear Static Analysis is carried out after assigning flexural hinges (FEMA 356 Auto hinges) using ATC 40 Capacity Spectrum Method. As a result performance points & levels (IO, LS, and CP) are found in different pushover steps (Fig 6 to Fig 9) and Base shear vs. Displacement Graph (Table 2 & Graph 1) & Spectral Acceleration vs. Spectral Displacement Graph (Table 3 & Graph 2) is drawn and Spectral Displacement Demand & Spectral Displacement Capacity is calculated. Graph 1. Base Shear vs. Displacement 171

Table 2. Base Shear vs. Displacement Step Base Shear Displacement KN m 0 0 0.000039 1 136899.174 0.100039 2 222856.176 0.162827 3 284985.307 0.219658 4 263707.831 0.219668 5 268281.579 0.22565 6 245620.866 0.22566 7 246819.898 0.227053 8 227219.076 0.227063 9 237728.881 0.240471 10 225303.553 0.240481 11 219414.809 0.240491 12 224582.491 0.24803 13 198330.277 0.24804 14 209413.302 0.26341 15 203894.231 0.26342 16 219816.986 0.300175 17 196858.807 0.300185 18 202744.179 0.312539 19 189099.878 0.312549 20 196119.064 0.328297 21 174905.96 0.328307 22 181815.673 0.344237 23 112332.892 0.28418 4 0.33107 0.12874 0.16711 0.00709 5 0.33302 0.13027 0.17181 0.00714 6 0.34827 0.17648 0.17284 0.0067 7 0.34851 0.1757 0.17389 0.00673 8 0.36347 0.22164 0.17444 0.0064 9 0.36608 0.21231 0.18482 0.00667 10 0.38626 0.24949 0.19112 0.0067 11 0.39149 0.25895 0.19141 0.00672 12 0.39304 0.25412 0.19736 0.00686 13 0.41522 0.30097 0.20261 0.00713 14 0.41616 0.28299 0.20271 0.00729 15 0.42181 0.2911 0.23011 0.00786 16 0.43397 0.2778 0.23215 0.00863 17 0.45665 0.34035 0.23275 0.00931 18 0.45897 0.32496 0.24431 0.00944 19 0.47664 0.37142 0.25115 0.0105 Fig 6. Pushover Step 1 Graph 2. Pushover Demand Capacity Curve (ATC 40) Table 3. Pushover Demand Capacity Curve (ATC 40) Pushover Curve Demand Capacity - ATC40 - PUSH Step T eff B eff Sd Capacity (m) Sd Demand (m) 0 0.30081 0.05 0 0.00843 1 0.30081 0.05 0.07369 0.00843 2 0.30081 0.05 0.11995 0.00843 3 0.31086 0.0714 0.16259 0.00795 Fig 7. Pushover Step 2 172

Displacement Demand values according to Capacity Spectrum Method ATC 40 at effective time 0.301 secs. Table 4. Comparison between Capacity & Demand (ATC 40) Pushover Step Between 2 & 3 Effective Time, Teff (Sec) Spectral Displacement Capacity (m) Spectral Displacement Demand (m) 0.301 0.120778 0.008420 Fig 8. Pushover Step 3 Fig 9. Pushover Step 4 The effective time is 0.301; it is in between pushover step 2 and step 3. At effective time the Spectral Displacement Capacity (m) and Spectral Displacement Demand (m) is calculated by interpolating values in the Table 3. The Table 4 shows the Spectral Displacement Capacity and Spectral 173 Graph 3. Comparison between Sd Capacity & Sd Demand IX. CONCLUSION From non linear static analysis using FEMA 356 hinges we can identify the zones of, immediate occupancy, Life safety and Collapse prevention point are found out. From the Analysis, Spectral Displacement Capacity is more than the Spectral Displacement Demand, so the analysed Diagrid Building doesn t require redesign. ACKNOWLEDGMENT The authors thank the Principal and Management of BLDEA s V.P Dr.P.G.Halakatti College of Engineering & Technology, Bijapur for the continued support and cooperation in carrying out this research study. REFERENCES [1] Analysis and design of diagrid structural system for high rise steel buildings Authors: Khushbu Jania, Paresh V. Patel (3rd Nirma University International Conference on Engineering (NUiCONE-2012)). [2] Design and Construction of steel diagrid structures Author: K.Moon, School of architecture, Yale university, New haven, USA. [3] Strategies to reduce lateral forces on high-rise buildings that use diagrid structural system Authors: Binh K.Nguyen and Hasim Altan, School of Architecture The University of Sheffield, United Kingdom. [4] Diagrid structures: innovation and detailing T. M. Boake (School of Architecture, University of Waterloo, Canada).

[5] IS 875 (Part 2): 1987 - Code of practice for design loads (other than earthquake) for buildings and structures. [6] IS 1893 (Part 1): 2002 - Criteria for Earthquake resistant Design of structures. [7] IS 800 1984 - Code of practice for General construction in steel. AUTHOR BIOGRAPHY R.G.Talasadar is currently working as Associate Professor in Civil Engineering Department at BLDEA s V.P. Dr.P.G.Halakatti College of Engineering & Technology, Bijapur, and Karnataka, India. He is post graduate from BLDEA s V.P. Dr.P.G.Halakatti College of Engineering & Technology, Bijapur. Ravi K Revankar is pursuing his Masters degree in Structural Engineering in Civil Engineering Department at BLDEA s V.P. Dr.P.G.Halakatti College of Engineering Technology, Bijapur, and Karnataka, India. He is presently carrying out his dissertation work under the guidance of Prof. R.G.Talasadar. 174