Tension and compression testing of fibre reinforced polymer (FRP) bars

Similar documents
Slenderness ratio effect on the behavior of steel and carbon-frp reinforced concrete-filled FRP tubes

CONFINEMENT EFFECT OF FRP AND TRANSVERSE STEEL ON RETROFITTING SQUARE CONCRETE COLUMNS

1. INTRODUCTION. (a) Sand/ Fabric-coated (b) Sand-coated deformed. (c) Helical wrapped/ribbed Fig.1 FRP anchors with different outer surfaces

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete

Behaviour of FRP wrapped circular concrete columns under eccentric loading

1. INTRODUCTION. Fig.1 Dimension of test specimen

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

EXPOSURE TEST AND LONG-TERM CHARACTERISTICS FOR CFRP STRUCTURAL MEMBERS

Modelling shearing characteristics of reinforced concrete

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

GFRP HOLLOW-CORE REBARS FOR CONCRETE BEAMS

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

Behaviour of FRP wrapped circular reinforced concrete columns

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

Experimental study on FRP tube reinforced concrete columns under different loading conditions

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Behaviour of perforated GFRP tubes under axial compression

Moment curvature analysis of concrete flexural members confined with CFRP grids

GFRP-STEEL HYBRID REINFORCED CONCRETE BRIDGE DECK SLABS IN QUEBEC, CANADA

CHAPTER III METHODS AND MATERIALS

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

ANCHORING METHOD FOR PRESTRESSING OF FRP REINFORCEMENT

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

An Experimental Investigation on Mechanical Behavior of Macro Synthetic Fiber Reinforced Concrete

GROUND ANCHOR TENDONS IN CARBON FIBRE-REINFORCED POLYMERS

Tests on FRP-Concrete Bond Behaviour in the presence of Steel

Jagannathan Saravanan et al IJCSET January 2012 Vol 2, Issue 1,

Study of the bond behavior of carbon fibre reinforced polymer bars

Behavior of Concrete-Filled FRP Tubes Under Bending, Axial Loads, and Combined Loading. Amir Fam, Bart Flisak and Sami Rizkalla

GLASS FIBER-REINFORCED PLASTIC POLES FOR TRANSMISSION AND DISTRIBUTION LINES: AN EXPERIMENTAL INVESTIGATION

with Fillers Department of Civil Engineering, National Taipei University of Technology, Taiwan, R.O.C

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

INNOVATIVE HYBRID WEARING SURFACES FOR FRP BRIDGE DECKS

EXPERIMENTAL STUDY ON RC COLUMNS RETROFITTED BY FRP AND SUBJECTED TO SEISMIC LOADING

PHYSICAL, MECHANICAL, AND DURABILITY CHARACTERIZATION OF CARBON FRP CABLE

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

ScienceDirect. The examination of the Glass Fiber Reinforced Polymer composite rods in terms of the application for concrete reinforcement

Sustainable Shear Behaviour of 2-Span Continuous Reinforced Concrete T-Beams with CFRP Strips

A Study on Hybrid FRP Wrapped Axially Loaded RC Capsule Column

Beam Pull Out Tests of NSM FRP and Steel Bars in Concrete

(FRP) ( CFRP

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

USE OF CFRP ANCHORS TO STRENGTHEN LAP SPLICES OF RECTANGULAR RC COLUMNS

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

Effects Of Slenderness Ratio In RC Slender Column Using GFRP And CFRP Confinement

Bond-Slip Response of FRP Reinforcing Bars in Fiber Reinforced Concrete under Direct Pullout

Seismic Performance of GFRP-RC Exterior Beam-Column Joints with Lateral Beams

Analysis of concrete columns Reinforced by Fiber Reinforced Polymers Bars Mohamed Husain, Hilal Hassan, Eman Salama

ABSTRACT. KEY WORDS: Tubular piles; composite behavior; offshore structures; push-out strength; bond strength; slip.

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

In-plane testing of precast concrete wall panels with grouted sleeve

BRAIDED REINFORCED FRP RODS

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

RETROFITTING OF COLUMNS WITH RC JACKETTING AN EXPERIMENTAL BEHAVIOR

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

THE DESIGN OF EXTERNALLY BONDED REINFORCEMENT (EBR) FOR REINFORCED CONCRETE STRUCTURES BY MEANS OF FIBRE REINFORCED POLYMERS (FRP)

ZANCO Journal of Pure and Applied Sciences

Rectangular Filament-Wound GFRP Tubes Filled with Concrete under Flexural. and Axial Loading: Experimental Investigation ABSTRACT

Bond Characteristics of GFRP Sheet on Strengthened Concrete Beams due to Flexural Loading

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

INVESTIGATION OF INTERFACIAL BOND STRENGTH IN CFRP ROD REINFORCED CONCRETE. Abstract

EXTERNAL CONFINEMENT OF PLAIN AND REINFORCED CONCRETE COLUMNS USING PVC PIPES

Comparative Study of GFRP Rebar and Steel Rebar used in Concrete Sections

The Mechanical Properties of High Strength Concrete for Box Girder Bridge Deck in Malaysia

GFRP retrofitted RC frames with columns subjected to high axial stresses

THE EFFECT OF FATIGUE LOADING ON BOND STRENGTH OF CFRP BONDED STEEL PLATE JOINTS

ALKALI AGGREGATE REACTIVE MORTAR CYLINDERS PARTLY RESTRAINED BY EXTERNAL CFRP FABRIC EXPANSION AND CONFINEMENT

Application of Tensioned CFRP Strip Method to an Existing Bridge

Cyclic In-Plane Shear of Concrete Masonry Walls Strengthened by FRP Laminates

PRELIMINARY EXPERIMENTAL STUDY ON PRESTRESSED GROUTED SLEEVE CONNECTION OF FRP TUBULAR MEMBERS UNDER COMPRESSION

Experimental Investigation on Cold-Formed Steel Foamed Concrete Composite Wall under Compression

NEW HYBRID GLULAM BEAM REINFORCED WITH CFRP AND ULTRA-HIGH-PERFORMANCE CONCRETE

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

Experimental Behavior of Concrete Cylinders Confined with CFRP Composites

DELAYING REINFORCED CONCRETE BEAM CRACKS USING CFRP (NUMERICAL MODELING)

Strengthening Concrete Sections by FRP Materials

Flexural Performance of Reinforced Concrete Beams with a Layer of Expansive Strain-hardening Cement -based Composite(SHCC)

STRENGTHENING STEEL-CONCRETE COMPOSITE BRIDGES WITH HIGH MODULUS CARBON FIBER REINFORCED POLYMER (CFRP) LAMINATES

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

ANCHOR BOLTS IN CLAY MASONRY WALLS

INNOVATIVE SEISMIC RETROFITTING OF OLD-TYPE RC COLUMNS THROUGH JACKETING: TEXTILE-REINFORCED MORTARS (TRM) VERSUS FIBER-REINFORCED POLYMERS (FRP)

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

Site Director: Dr. Sami Rizkalla Associate Director: Dr. Rudi Seracino Date: February 1 st, 2011

Performance Evaluation Of Bamboo Twig As A Potential Reinforcement In Concrete Considering Tensile Property

FE Review Mechanics of Materials

Strengthening of infilled RC frames by CFRP

Dynamic Compressive Behavior of FRP-Confined Concrete Under Impact and a New Design-Oriented Strength Model

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

ULTIMATE LOAD-CARRYING CAPACITY OF SELF-ANCHORED CONCRETE SUSPENSION BRIDGE

Department of Civil Engineering, Monash University, Melbourne, Australia 2

Stress Analysis of Underground GRP Pipe Subjected to Internal and External Loading Conditions

Transcription:

University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2015 Tension and compression testing of fibre reinforced polymer (FRP) bars Qasim S. Khan University of Wollongong, qsk991@uowmail.edu.au M Neaz Sheikh University of Wollongong, msheikh@uow.edu.au Muhammad N. S Hadi University of Wollongong, mhadi@uow.edu.au Publication Details Khan, Q. S., Sheikh, M. Neaz. & Hadi, M. N. S. (2015). Tension and compression testing of fibre reinforced polymer (FRP) bars. In Z. Wu, G. Wu & X. Wang (Eds.), Joint Conference of the 12th International Symposium on Fiber Reinforced Polymers for Reinforced Concrete Structures (FRPRCS-12) & the 5th Asia-Pacific Conference on Fiber Reinforced Polymers in Structures (APFIS-2015) (pp. 1-6). Research Online is the open access institutional repository for the University of Wollongong. For further information contact the UOW Library: research-pubs@uow.edu.au

Tension and compression testing of fibre reinforced polymer (FRP) bars Abstract Corrosion of reinforcement in steel Reinforced Concrete (RC) columns significantly decreases both the strength and ductility of RC columns. Fibre Reinforced Polymer (FRP) bars have emerged as an attractive alternative to the traditional steel bars because of higher ultimate tensile strength to weight ratio and higher corrosion resistance of the FRP bars. However, Standard test methods for different types of FRP bars both in tension and compression have not been fully developed. This study presents the results of tension and compression tests of circular pultruded Glass FRP (GFRP) bars and Carbon FRP (CFRP) bars of 15 mm and 15.9 mm diameter, respectively. The tensile and the compressive properties of these bars were determined according to ASTM D7205/M7205-06 (tension test) and ASTM D695-10 (compression test) with some modifications. For tensile properties, three 1555 mm long GFRP bars and three 1555 mm long CFRP bars were tested in tension. For compressive properties, five 80 mm long GFRP and five 60 mm long CFRP bars were tested in compression. In tension, the tested FRP bars failed due to rupture of fibres whereas in compression the tested FRP bars failed due to separation of longitudinal fibres. The experimental results showed that the ultimate strength and modulus of elasticity of FRP bars in tension are 1.67 and 1.59 times greater than in compression respectively. Disciplines Engineering Science and Technology Studies Publication Details Khan, Q. S., Sheikh, M. Neaz. & Hadi, M. N. S. (2015). Tension and compression testing of fibre reinforced polymer (FRP) bars. In Z. Wu, G. Wu & X. Wang (Eds.), Joint Conference of the 12th International Symposium on Fiber Reinforced Polymers for Reinforced Concrete Structures (FRPRCS-12) & the 5th Asia- Pacific Conference on Fiber Reinforced Polymers in Structures (APFIS-2015) (pp. 1-6). This conference paper is available at Research Online: http://ro.uow.edu.au/eispapers/5008

The 12th International Symposium on Fiber Reinforced Polymers for Reinforced Concrete Structures (FRPRCS-12) & The 5th Asia-Pacific Conference on Fiber Reinforced Polymers in Structures (APFIS-2015) Joint Conference, 14-16 December 2015, Nanjing, China TENSION AND COMPRESSION TESTING OF FIBRE REINFORCED POLYMER (FRP) BARS Qasim S. Khan 1, M. Neaz Sheikh 2, Muhammad N.S. Hadi 3 1 Ph.D. Candidate, School of Civil, Mining and Environmental Engineering, University of Wollongong, Australia Email: qsk991@uowmail.edu.au 2 Senior Lecturer, School of Civil, Mining and Environmental Engineering, University of Wollongong, Australia Email: msheikh@uow.edu.au 3 Associate Professor, School of Civil, Mining and Environmental Engineering, University of Wollongong, Australia Email: mhadi@uow.edu.au Keywords: GFRP bars, CFRP bars, Tension test, Compression test ABSTRACT Corrosion of reinforcement in steel Reinforced Concrete (RC) columns significantly decreases both the strength and ductility of RC columns. Fibre Reinforced Polymer (FRP) bars have emerged as an attractive alternative to the traditional steel bars because of higher ultimate tensile strength to weight ratio and higher corrosion resistance of the FRP bars. However, Standard test methods for different types of FRP bars both in tension and compression have not been fully developed. This study presents the results of tension and compression tests of circular pultruded Glass FRP (GFRP) bars and Carbon FRP (CFRP) bars of 15 mm and 15.9 mm diameter, respectively. The tensile and the compressive properties of these bars were determined according to ASTM D7205/M7205-06 (tension test) and ASTM D695-10 (compression test) with some modifications. For tensile properties, three 1555 mm long GFRP bars and three 1555 mm long CFRP bars were tested in tension. For compressive properties, five 80 mm long GFRP and five 60 mm long CFRP bars were tested in compression. In tension, the tested FRP bars failed due to rupture of fibres whereas in compression the tested FRP bars failed due to separation of longitudinal fibres. The experimental results showed that the ultimate strength and modulus of elasticity of FRP bars in tension are 1.67 and 1.59 times greater than in compression respectively. 1 INTRODUCTION Fibre Reinforced Polymer (FRP) bars have emerged as an attractive alternative of steel bars due to higher ultimate tensile strength to weight ratio, resistance to corrosion and chemical attack, electromagnetic neutrality, and long term strength and durability of FRP bars in harsh and corrosive environments [1, 2]. The widespread use of FRP bars in Reinforced Concrete (RC) members has yet been limited due to anisotropic and non-homogeneous material behaviour of FRP. Standard methods to test different types and diameters of FRP bars in tension and compression have not been fully developed. ASTM D7205M/7205-06 [3] only covers tensile testing of 6.4 to 32 mm diameter Glass FRP (GFRP) bars and 9.5 mm diameter Carbon FRP (CFRP) bars. A standard test method of compression testing of FRP bars has not yet been introduced [4]. The tensile testing of FRP bars is complicated due to significantly smaller shear strength of FRP bars than their tensile strength. Benmokrane et al. [2] successfully tested 7.5, 8.0 and 10.0 mm diameter AFRP bars and 7.9 and 8.0 mm diameter CFRP bars, whereas Kocaoz [5] tested 12.5 mm diameter GFRP bars in tension using

Qasim S. Khan, M. Neaz Sheikh, M. N. S. Hadi expansive cement grouted steel tube anchors. Carvelli et al. [6] introduced a test arrangement consisted of conical resin heads which fits into the conical hole in the anchor for tensile testing of large diameter GFRP bars. Castro [7] reviewed different anchors used for tensile testing of FRP bars and recommended a testing arrangement consisting of FRP bar embedded in steel tubes filled with high strength gypsum cement mortar. Fujisaki and Kobayashi [8] tested FRP bars embedded in concrete prisms at both ends with 5 mm clear length in compression and reported compressive strength of Aramid FRP (AFRP), CFRP and GFRP bars as 10%, 30-50% and 30-40% of tensile strength. Deitz et al. [9] tested 15 mm diameter GFRP bars of varying clear length to diameter ratios with both ends embedded in 50 mm diameter and 135 mm length threaded steel rods by modifying ASTM D695-10 [10] test method for compression testing of rigid plastics. The study recommended clear length to diameter ratios smaller than 7.3, 14 and 25.3 for crushing, combined crushing and buckling, and buckling failures, respectively. In this experimental study, CFRP and GFRP bars are tested in tension and compression by modifying the ASTM D7205M/7205-06 [3] and ASTM D695-10 [10], respectively. The loadextension and stress-strain of tested FRP bars in tension and compression have been reported. 2 EXPERIMENTAL PLAN This experimental study reports the tensile testing of three GFRP and three CFRP bars (ASTM D7205M/7205-06 [3]) and compression testing of five CFRP and five GFRP bars (ASTM D695-10 [10]) conducted at High Bay Laboratories, School of Civil, Mining and Environmental Engineering, University of Wollongong, Australia. Tested bars have 100% of the fibres oriented along the longitudinal direction (Pultruded bars). GFRP bars were sand coated whereas CFRP bars were smooth without any coating. Table 1 provides details of diameter and length of GFRP and CFRP bars. Internal and external diameter and length of steel tube anchors used in tensile testing are also reported. Table 2 provides details of diameter and length of GFRP and CFRP bars used in compression testing. Type of FRP Reinforcement Number of Specimens tested Table 1 Details of Tension test specimens Diameter of FRP bar, D [mm] Length of FRP bar, L [mm] Outer Diameter of anchor, D [mm] Inner Diameter of anchor, D [mm] Length of anchor, L [mm] GFRP 3 15.9 1555 45 30 460.0 CFRP 3 15.0 1555 45 30 477.5 Table 2 Details of Compression test specimens Type of FRP Reinforcement Number of Specimens tested Diameter of FRP bar, D (mm) Length of FRP bar, L (mm) GFRP 5 15.9 80 CFRP 5 15.0 60 Tested bars were designated according to the type of FRP bars and type of test arrangement and FRP bar number tested in one particular series. This study investigates material properties of two types of FRP bars i.e., GFRP bars (GB) and CFRP bars (CB), under two types of testing arrangements i.e., Tension test (T) and Compression test (C). A number is included to indicate the bar tested in the sequence. For example, CB-T-1 refers to CFRP bar tested in tension and is the first bar. 3 TEST METHODOLOGY The tension testing of FRP bars was conducted in 500 kn Instron Universal Testing Machine (UTM) while compression testing of FRP bars was conducted in 100 kn Instron UTM (Figure 1). The tension test arrangement consisted of FRP bar embedded in steel tube anchors at the ends. This is

The 12th International Symposium on Fiber Reinforced Polymers for Reinforced Concrete Structures (FRPRCS-12) & The 5th Asia-Pacific Conference on Fiber Reinforced Polymers in Structures (APFIS-2015) Joint Conference, 14-16 December 2015, Nanjing, China because the shear strength of FRP bars is significantly smaller than steel bars and without steel tube anchors FRP bars would fail prematurely at the point of contact with steel grips in the loading heads. The dimensions of steel tube anchors reported here were selected after numerous trials as ASTM D7205M/7205-06 [3] only states the minimum thickness, length and outside and inside diameters of steel tube anchors. Moreover, ASTM D7205M/7205-06 [3] does not cover the tensile testing of 15 mm diameter CFRP bar. To the knowledge of the Authors there is no available study in which 15 mm diameter CFRP bar has been tested in tension. Tested CFRP bars were coated with two layers of coarse sand to increase the friction between bars and steel tube anchors whereas tested GFRP bars were obtained in sand coated condition from the manufacturer. The steel tube anchors of 7.5 mm thickness were filled with expansive cement grout on alternate days as cement grout requires minimum of 16 hours to develop expansive stresses (30 MPa) before grouted steel tube anchor ends could be turned upside down. According to the specifications provided by the manufacturer, expansive cement grout would generate the maximum expansive pressure after 72 hours of casting. FRP bars were tested in tension after 72 hours of casting under the displacement controlled load rate of 1.0 to 1.3 mm per minute to produce rupture of the fibres within the free length (gauge length) of the tested bars (Figure 1 (a)). (a) Tension testing (b) Compression testing Figure 1 Testing arrangement for CFRP and GFRP bars (a) Tension testing (b) Compression testing To test FRP bars in compression, ASTM D695-10 [10] compression test method for rigid plastics was simplified by replacing the hardened blocks with flat and paralleled high strength steel plates. Moreover, as standard allows for any suitable testing machine which is capable of applying load at a constant controlled load rate hence 100 kn Instron UTM was used for compression testing of FRP bars (Figure 1 (b)). The testing arrangement for compression test consisted of two flat steel plates fixed to the loading heads of the 100 kn Instron UTM. In the laboratory, CFRP and GFRP specimens were cut to the required lengths of 60 mm and 80 mm, respectively. Each compression test specimen with flat parallel ends was placed vertically between the loading heads of the UTM and tested under displacement controlled load at a rate of 1.0 to 1.3 mm per minute until failure. 4 TEST RESULTS AND DISCUSSIONS This section reports the observed failure, peak load-extension and peak stress-strain of tested FRP bars under tension and compression (Table 3). In tension test, particularly in case of GFRP bars,

Qasim S. Khan, M. Neaz Sheikh, M. N. S. Hadi progressive slippage was observed. It is noted that ASTM D7205M/7205-06 [3] allows a progressive slippage as long as the failure is within the gauge length. It is also noted that the slippage in the case of CFRP bars was smaller compared to the slippage observed in GFRP bars. Table 3 Experimental results of Tension testing of FRP bars Specimen ID Peak Tensile Ultimate Tensile Ultimate Tensile Modulus of Load [kn] Extension [mm] Strength [MPa] Elasticity [GPa] GB-T-1 258.0 28.3 1307.5 55.6 GB-T-2 278.9 39.4 1409.5 54.8 GB-T-3 290.2 28.0 1467.8 57.5 CB-T-1 199.2 11.7 1127.6 86.9 CB-T-2 211.1 13.1 1195.1 86.7 CB-T-3 202.8 12.0 1148.0 94.6 The observed tensile failure in tested GFRP and CFRP bars was due to tensile rupture of fibres with in the gauge length of bars as shown in Figure 2. This shows that the selected dimensions of steel tube anchors were sufficient to hold FRP bars and prevented uncontrolled slippage. (a) GFRP bar (b) CFRP bar Figure 2 Observed tensile failure modes in tested FRP bars The observed tensile stress-strain behaviour of tested FRP bars is presented in Figure 3. The peak tensile stress-strain of GFRP bars was larger than that of CFRP bars. Furthermore, the tensile strength of GFRP bars was about 1.25 times of that of CFRP bars. Modulus of elasticity (E) of FRP bars was determined as a gradient of tensile stress-strain curve up to 0.3% tensile strain (ASTM D7205M/7205-06 [3]). Hence the effect of slippage can be ignored in calculating the E of tested FRP bars. (a) GFRP Bars Figure 3 Tensile stress-strain in tested FRP bars (b) CFRP bars

The 12th International Symposium on Fiber Reinforced Polymers for Reinforced Concrete Structures (FRPRCS-12) & The 5th Asia-Pacific Conference on Fiber Reinforced Polymers in Structures (APFIS-2015) Joint Conference, 14-16 December 2015, Nanjing, China The E of CFRP bars was 1.6 times of GFRP bars. Although, ASTM D7205M/7205-06 [3] standard allows progressive slippage of bar during the test, due to slippage the ultimate tensile strains obtained from UTM may not be the true ultimate tensile strain of the tested bars. It is recommended to calculate ultimate tensile strain as a ratio of ultimate tensile strength to modulus of elasticity of FRP bar. The observed peak compressive load-deformation and compressive stress-strain of tested FRP bars is given in Table 4. Specimen ID Table 4 Experimental results of Compression testing of FRP bars Peak Compressive Load [kn] Peak Compressive Deformation [mm] Ultimate Compressive Strength [MPa] Ultimate Compressive Strain [%] Modulus of Elasticity [GPa] GB-C-1 183.2 2.1 995.5 2.9 40.0 GB-C-2 147.1 1.9 743.4 2.6 41.5 GB-C-3 155.1 1.8 783.9 2.6 42.0 GB-C-4 159.0 1.9 803.6 2.8 43.3 GB-C-5 178.7 1.9 903.2 2.9 43.3 CB-C-1 100.8 0.9 570.6 1.6 49.7 CB-C-2 109.1 0.8 617.6 1.6 50.0 CB-C-3 103.5 0.9 586.2 1.6 46.4 CB-C-4 105.7 0.8 598.5 2.0 50.0 CB-C-5 107.6 0.9 609.3 1.5 49.2 The observed failure modes in the tested GFRP and CFRP bars in compression are shown in Figure 4. It is noted that both types of FRP bars tested in compression failed due to separation of fibres which may be due to failure of the resin rather than buckling of fibres. (a) GFRP bars Figure 4 Observed failure modes in tested FRP bars (b) CFRP bars The observed compressive stress-strain behaviour of both GFRP and CFRP bars was similar. The observed ultimate compressive stress-strains were higher for GFRP bars than for CFRP bars. (a) GFRP Bars Figure 5 Compressive stress-strain of tested FRP bars (b) CFRP Bars

Qasim S. Khan, M. Neaz Sheikh, M. N. S. Hadi The variations in compressive stress-strain within the tested GFRP and CFRP bars series were small. The compressive strength values obtained for GFRP bars were 1.4 times higher than CFRP bars, and ultimate compressive strains corresponding to ultimate compressive strength were 1.65 times higher in GFRP bars than in CFRP bars. The ultimate compressive strains of tested FRP bars obtained from tests were reported as recorded in compression test as there is no slippage and values are reliable. The E of CFRP bars was 1.17 times greater than GFRP bars. The E of GFRP bars (42.0 GPa) obtained in this study is almost identical to the value (42 GPa) reported by Deitz et al. [9] 5 CONCLUSIONS This experimental study reports the load-extension and stress-strain behaviours of the tested CFRP and GFRP bars under tension and compression. The main conclusions of this experimental study are as follows; The modified test methods adopted in this study for tension and compression tests of 15.9 mm and 15 mm diameters GFRP and CFRP bars, respectively were successful and could be adopted for testing of other types and diameter of FRP bars. GFRP bars attained higher load-extension and stress-strain in both tension and compression than CFRP bars for the same nominal diameter. The ultimate tensile strengths of GFRP and CFRP bars were 65% and 94% higher than their ultimate compressive strengths, respectively. The tensile modulus of elasticity of GFRP and CFRP bars were 33% and 89% higher than their compressive modulus of elasticity, respectively. REFERENCES [1] Q.S. Khan, J.S. Strong, M.N. Sheikh and M.N.S. Hadi, Flexural Testing of Concrete Filled Fibre Reinforced Polymer Tubes (CFFT) with and without internal Fibre Reinforced Polymer (FRP) Reinforcement, in 27th Biennial National Conference of the Concrete Institute of Australia in conjunction with the 69th RILEM Week Conference. 2015: Melbourne, Australia. [2] B. Benmokrane, B. Zhang, and A. Chennouf, Tensile properties and pull out behaviour of AFRP and CFRP rods for grouted anchor applications. Construction and Building Materials, 2000. 14: p. 157-170. [3] ASTM:D695, Standard Test Method for Compressive Properties of Rigid Plastics, in D695-10. 2010, ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959 United States. [4] M. Afifi, H. Mohamed, and B. Benmokrane, Axial Capacity of Circular Concrete Columns Reinforced with GFRP Bars and Spirals. Journal of Composites for Construction, 2014. 0(0): p. 04013017. [5] S. Kocaoz, V.A. Samaranayake, and A. Nanni, Tensile characterization of glass FRP bars. Composites Part B: Engineering, 2005. 36(2): p. 127-134. [6] V. Carvelli, G. Fava, and M. Pisani, Anchor System for Tension Testing of Large Diameter GFRP Bars. Journal of Composites for Construction, 2009. 13(5): p. 344-349. [7] P. Castro and N. Carino, Tensile and Nondestructive Testing of FRP Bars. Journal of Composites for Construction, 1998. 2(1): p. 17-27. [8] K. Kobayashi and T. Fujisaki, Compressive behaviour of FRP reinforcement in nonprestressed concrete members, in Non metallic (FRP) reinforcement for concrete structures, Proceedings of the second international RILEM Symposium (FRPRCS-2), L.Taerwe, Editor. 1995, E & FN SPON, 2-6 Boundary Row, London SE18HN: Ghent. [9] D. Deitz, I. Harik, and H. Gesund, Physical Properties of Glass Fiber Reinforced Polymer Rebars in Compression. Journal of Composites for Construction, 2003. 7(4): p. 363-366. [10] ASTM:D7205/D7205M, Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix Composite Bars, in D7205/D7205M-08. 2008, ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959: United States.